Decoupled Control Strategy of Grid Interactive Inverter System with Optimal LCL Filter Design

2013 ◽  
Vol 14 (5) ◽  
pp. 477-486 ◽  
Author(s):  
B. Chitti Babu ◽  
Anup Anurag ◽  
Tontepu Sowmya ◽  
Debati Marandi ◽  
Satarupa Bal

Abstract This article presents a control strategy for a three-phase grid interactive voltage source inverter that links a renewable energy source to the utility grid through a LCL-type filter. An optimized LCL-type filter has been designed and modeled so as to reduce the current harmonics in the grid, considering the conduction and switching losses at constant modulation index (Ma). The control strategy adopted here decouples the active and reactive power loops, thus achieving desirable performance with independent control of active and reactive power injected into the grid. The startup transients can also be controlled by the implementation of this proposed control strategy: in addition to this, optimal LCL filter with lesser conduction and switching copper losses as well as core losses. A trade-off has been made between the total losses in the LCL filter and the Total Harmonic Distortion (THD%) of the grid current, and the filter inductor has been designed accordingly. In order to study the dynamic performance of the system and to confirm the analytical results, the models are simulated in the MATLAB/Simulink environment, and the results are analyzed.

2014 ◽  
Vol 960-961 ◽  
pp. 1356-1360 ◽  
Author(s):  
Yu Zhou ◽  
Zhi Yong Dai ◽  
Qiang Gang Wang ◽  
Ling Ye ◽  
Nian Cheng Zhou

This paper studies the instantaneous output power characteristics of photovoltaic inverters and its flexible power control strategy under unbalanced grid faults. Then the optimal parameters model of the power control is established with minimum integrated fluctuation amplitude of the active and reactive power as a goal when the constraint of the output current harmonic distortion of photovoltaic inverters is taken into account. Finally, the optimal power control of photovoltaic inverters based on dead-beat current tracking is realized and the feasibility of the proposed control strategy is verified with the power system transient software PSCAD/EMTDC.


Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 3140 ◽  
Author(s):  
Weiming Liu ◽  
Tingting Zheng ◽  
Ziwen Liu ◽  
Zhihua Fan ◽  
Yilong Kang ◽  
...  

This paper presents a power compensation strategy to suppress the double frequency power ripples of Voltage source converter high-voltage direct current (VSC-HVDC) systems under unbalanced grid voltage conditions. The mathematical control equations of the double frequency ripple power of VSC under unbalanced operating conditions are firstly derived and established, where the dynamic behaviors of the double frequency ripples in active and reactive power are regarded as being driven by current-relevant components and voltage-relevant components, respectively. Based on the equations, a power compensation control strategy of VSC-HVDC is proposed via the passivity-based control with disturbance observer to suppress both the current-relevant and voltage-relevant components in the power ripples. With this control strategy, the double frequency ripples in active and reactive power are suppressed simultaneously and system performance is significantly enhanced with the implementation of the disturbance observer in the passivity-based control. Theoretical stability analysis and simulation cases show the effectiveness and superiority of the proposed strategy.


Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 831 ◽  
Author(s):  
Janeth Alcalá ◽  
Víctor Cárdenas ◽  
Alejandro Aganza ◽  
Jorge Gudiño-Lau ◽  
Saida Charre

Nowadays, the use of power converters to control active and reactive power in AC–AC grid-connected systems has increased. With respect to indirect AC–AC converters, the tendency is to enable the back-to-back (BTB) voltage source converter (VSC) as an active power filter (APF) to compensate current harmonics. Most of the reported works use the BTB-VSC as an auxiliary topology that, combined with other topologies, is capable of active power regulation, reactive power compensation and current harmonic filtering. With the analysis presented in this work, the framework of the dynamics associated with the control loops is established and it is demonstrated that BTB-VSC can perform the three tasks for which, in the reviewed literature, at least two different topologies are reported. The proposed analysis works to support the performance criteria of the BTB-VSC when it executes the three control actions simultaneously and the total current harmonic distortion is reduced from 27.21% to 6.16% with the selected control strategy.


Author(s):  
Mr. L NarayanaGadupudi Et.al

 Internal Liability of power system transmission lines influenced by the turbulences owing to catastrophic disasters. In order to achieve Constant Voltage Stability at both ends of the transmission lines, Static Synchronous Compensator (STATCOM) is imperative.  Voltage source Converter mechanisms augment with switching frequency control methodologies are widely adopted to regulate the reactive power. By deliberating IEEE Standards, the minimization of Total Harmonic Distortion (THD) is conceivable with STATCOM. This paper depicts the advancement of VSC based STATCOM approaches and the methodologies to minimize the switching losses. Economical management of High-Power ratings systems is also discussed in this paper


2011 ◽  
Vol 464 ◽  
pp. 61-64
Author(s):  
Guo Jun Tan ◽  
Zhang Fei Zhao ◽  
Zong Bin Ye ◽  
Yi Liu

In this paper, a constant switching frequency direct power control strategy based on the virtual line-flux-linkage oriented system for three-level PWM rectifier using space vector modulation (VF-DPC-SVM) is proposed, which is on the basis of the mathematic model of the PWM rectifier, the instantaneous reactive power and the vector control theory. Compared with the traditional control strategy, the proposed VF-DPC-SVM method guarantees a fixed switching frequency and realizes a better dynamic performance. The simulations and experiments indicate that the system has a better dynamic performance with lower harmonic current by use of the control strategy and can achieve the decoupling control of the active and reactive power.


Electronics ◽  
2021 ◽  
Vol 10 (9) ◽  
pp. 1061
Author(s):  
Iván Andrade ◽  
Rubén Pena ◽  
Ramón Blasco-Gimenez ◽  
Javier Riedemann ◽  
Werner Jara ◽  
...  

The development of distributed generation, mainly based on renewable energies, requires the design of control strategies to allow the regulation of electrical variables, such as power, voltage (V), and frequency (f), and the coordination of multiple generation units in microgrids or islanded systems. This paper presents a strategy to control the active and reactive power flow in the Point of Common Connection (PCC) of a renewable generation system operating in islanded mode. Voltage Source Converters (VSCs) are connected between individual generation units and the PCC to control the voltage and frequency. The voltage and frequency reference values are obtained from the P–V and Q–f droop characteristics curves, where P and Q are the active and reactive power supplied to the load, respectively. Proportional–Integral (PI) controllers process the voltage and frequency errors and set the reference currents (in the dq frame) to be imposed by each VSC. Simulation results considering high-power solar and wind generation systems are presented to validate the proposed control strategy.


2021 ◽  
pp. 1-14
Author(s):  
Mohd. Anas Anees ◽  
Mohammad ◽  
Kaif Ahmed Lodi ◽  
Mahetab Alam ◽  
Ripon K. Chakrabortty ◽  
...  

This paper proposes a model predictive control strategy for 15 level Packed-U-Cell inverter that satisfies multiple-objectives of low current total harmonic distortion (THD), capacitor voltage balances, supply of desired active and reactive power, as well as lower switching and lower voltage stresses on the switching devices. The proposed device performs well under dynamic conditions and can successfully track the current command during step changes in the power demand. A detailed modeling is presented and discussed. MATLAB/Simulink is used for obtaining the simulation results, and the results are validated in the real time by using a hardware-in-the-loop (HIL) Typhoon 402 real-time emulator.


2012 ◽  
Vol 63 (6) ◽  
pp. 392-396 ◽  
Author(s):  
Azeddine Draou

This paper presents the dynamic performance analysis of an Advanced Static Var Compensator (ASVC) using three-level neutral point-clamped voltage source inverter. The paper presents the principles of operating and the method of reference currents generation. The dynamic behaviour of the system is further analysed using Matlab/Simulink with SimPower Systems toolbox through a set of simulation tests. The results obtained have been applied to an active power filter which might lead to the design of a robust controller for current harmonics and reactive power applications


Author(s):  
Akram Qashou ◽  
Sufian Yousef ◽  
Abdallah A. Smadi ◽  
Amani A. AlOmari

AbstractThe purpose of this paper is to describe the design of a Hybrid Series Active Power Filter (HSeAPF) system to improve the quality of power on three-phase power distribution grids. The system controls are comprise of Pulse Width Modulation (PWM) based on the Synchronous Reference Frame (SRF) theory, and supported by Phase Locked Loop (PLL) for generating the switching pulses to control a Voltage Source Converter (VSC). The DC link voltage is controlled by Non-Linear Sliding Mode Control (SMC) for faster response and to ensure that it is maintained at a constant value. When this voltage is compared with Proportional Integral (PI), then the improvements made can be shown. The function of HSeAPF control is to eliminate voltage fluctuations, voltage swell/sag, and prevent voltage/current harmonics are produced by both non-linear loads and small inverters connected to the distribution network. A digital Phase Locked Loop that generates frequencies and an oscillating phase-locked output signal controls the voltage. The results from the simulation indicate that the HSeAPF can effectively suppress the dynamic and harmonic reactive power compensation system. Also, the distribution network has a low Total Harmonic Distortion (< 5%), demonstrating that the designed system is efficient, which is an essential requirement when it comes to the IEEE-519 and IEC 61,000–3-6 standards.