scholarly journals Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)

2014 ◽  
Vol 86 (3) ◽  
pp. 425-467 ◽  
Author(s):  
Willi A. Brand ◽  
Tyler B. Coplen ◽  
Jochen Vogl ◽  
Martin Rosner ◽  
Thomas Prohaska

AbstractSince the early 1950s, the number of international measurement standards for anchoring stable isotope delta scales has mushroomed from 3 to more than 30, expanding to more than 25 chemical elements. With the development of new instrumentation, along with new and improved measurement procedures for studying naturally occurring isotopic abundance variations in natural and technical samples, the number of internationally distributed, secondary isotopic reference materials with a specified delta value has blossomed in the last six decades to more than 150 materials. More than half of these isotopic reference materials were produced for isotope-delta measurements of seven elements: H, Li, B, C, N, O, and S. The number of isotopic reference materials for other, heavier elements has grown considerably over the last decade. Nevertheless, even primary international measurement standards for isotope-delta measurements are still needed for some elements, including Mg, Fe, Te, Sb, Mo, and Ge. It is recommended that authors publish the delta values of internationally distributed, secondary isotopic reference materials that were used for anchoring their measurement results to the respective primary stable isotope scale.

2020 ◽  
Vol 35 (10) ◽  
pp. 2213-2223
Author(s):  
Hugues Beunon ◽  
Stepan M. Chernonozhkin ◽  
Nadine Mattielli ◽  
Steven Goderis ◽  
Luc-Serge Doucet ◽  
...  

Simple chromatographic isolation of nickel in just two steps prior to Ni stable isotope ratio analysis by MC-ICP-MS.


2020 ◽  
pp. 66-72
Author(s):  
Irina A. Piterskikh ◽  
Svetlana V. Vikhrova ◽  
Nina G. Kovaleva ◽  
Tatyana O. Barynskaya

Certified reference materials (CRM) composed of propyl (11383-2019) and isopropyl (11384-2019) alcohols solutions were created for validation of measurement procedures and control of measurement errors of measurement results of mass concentrations of toxic substances (alcohol) in biological objects (urine, blood) and water. Two ways of establishing the value of the certified characteristic – mass consentration of propanol-1 or propanol-2 have been studied. The results obtained by the preparation procedure and comparison with the standard are the same within the margin of error.


2020 ◽  
pp. 64-70
Author(s):  
Mariya Y. Medvedevskikh ◽  
Anna S. Sergeeva

The article raises the problem of ensuring metrological traceability of the measurement results of indicators of quality and nutritional value for food products and food raw materials: water (moisture), nitrogen (protein, crude protein), fat, ash and carbohydrates. The problem under consideration can be solved by applying reference materials of food composition, traceable to state primary measurement standards GET 173-2017 and GET 176-2019 and primary reference measurement procedures (PRMP), for attestation of measurement procedures and accuracy checking of measurement results. The article discusses the results of the PRMP development of mass fraction of fat, ash and carbohydrates in food products and food raw materials, as well as mass fraction of crude fat (oil content) in oil crops seeds and products based on them. The paper also presents metrological characteristics of reference materials of composition of dry dairy products, grain-milk dry porridges for nutrition of babies, grain dry porridges for nutrition of babies, egg powder, freeze-dried meat products, animal feed. The results of the work allow for building a chain of metrological traceability from GET 173-2017, GET 176-2019 and PRMP to routine measurement procedures, thereby ensuring the uniformity of measurements of nutritional value of food products.


2020 ◽  
pp. 3-14
Author(s):  
O. M. Samoylenko ◽  
O. V. Adamenko ◽  
B. P. Kukareka

Reference method for simultaneous calibration of the three and more measurement standards for vertical angle measurement is developed. This method can to use for obtaining the systematic biases of the vertical angles measurements for each of the measuring standards relative of the horizontal plain was averaged from measurement results in time their calibration or comparison. For realization of the reference method was developed the autocollimationel electronic measurement standard for the automatization measurement of the vertical angles SeaLineZero_Standard™ (SLZ_S™). Summary standard deviation (k=1) of the vertical angle measurement relative the horizontal plane, from the results of their calibration by reference method, is not more 0,07ʺ…0,15ʺ. This result was obtained without the use the systematic biases, for each measurement standards, as measurements corrections (with opposite sign). The measuring standards, that were developed and researched, are necessary for obtaining the systematic biases of the vertical angle measurement for total stations and theodolites, that have the normed standard error 0,5ʺ and 1ʺ, when these instruments are calibrating.


2019 ◽  
Vol 276 ◽  
pp. 782-789 ◽  
Author(s):  
Luana Bontempo ◽  
Mauro Paolini ◽  
Pietro Franceschi ◽  
Luca Ziller ◽  
Diego L. García-González ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document