SlamTracker Accuracy under Static and Controlled Movement Conditions

2016 ◽  
Vol 25 (5-6) ◽  
pp. 374-383 ◽  
Author(s):  
Cain C. T. Clark ◽  
Claire M. Barnes ◽  
Mark Holton ◽  
Huw D. Summers ◽  
Gareth Stratton

Abstract Accelerometry is the de facto standard in objective physical activity monitoring. However traditional accelerometer units undergo proprietary pre-processing, resulting in the ‘black-box’ phenomenon, where researchers are unaware of the processes and filters used on their data. Raw accelerometers where all frequencies related to human movement are included in the signal, would facilitate novel analyses, such as frequency domain analysis and pattern recognition. The aim of this study was to quantify the mean, standard deviation and variance of the SlamTracker raw accelerometer at a range of speeds. Four tri-axial accelerometers underwent a one minute static condition test nine movement condition tests. Accelerometers were assessed for mean, standard deviation, sample variance and coefficient of variation throughout in all axes for all experimental conditions. The sample variance was <0.001g across all speeds and axes during the movement condition tests. In conclusion, the SlamTracker is shown to be an accurate and reliable device for measuring the raw accelerations of movement.

Sensors ◽  
2019 ◽  
Vol 19 (23) ◽  
pp. 5109
Author(s):  
Emanuele Rizzuto ◽  
Barbara Peruzzi ◽  
Mariagrazia Giudice ◽  
Enrica Urciuoli ◽  
Erika Pittella ◽  
...  

In this paper, the characterization of the main techniques and transducers employed to measure local and global strains induced by uniaxial loading of murine tibiae is presented. Micro strain gauges and digital image correlation (DIC) were tested to measure local strains, while a moving coil motor-based length transducer was employed to measure relative global shortening. Local strain is the crucial parameter to be measured when dealing with bone cell mechanotransduction, so we characterized these techniques in the experimental conditions known to activate cell mechanosensing in vivo. The experimental tests were performed using tibia samples excised from twenty-two C57BL/6 mice. To evaluate measurement repeatability we computed the standard deviation of ten repetitive compressions to the mean value. This value was lower than 3% for micro strain gauges, and in the range of 7%–10% for DIC and the length transducer. The coefficient of variation, i.e., the standard deviation to the mean value, was about 35% for strain gauges and the length transducer, and about 40% for DIC. These results provided a comprehensive characterization of three methodologies for local and global bone strain measurement, suggesting a possible field of application on the basis of their advantages and limitations.


2016 ◽  
Vol 38 (3) ◽  
Author(s):  
Mohammad Fraiwan Al-Saleh ◽  
Adil Eltayeb Yousif

Unlike the mean, the standard deviation ¾ is a vague concept. In this paper, several properties of ¾ are highlighted. These properties include the minimum and the maximum of ¾, its relationship to the mean absolute deviation and the range of the data, its role in Chebyshev’s inequality and the coefficient of variation. The hidden information in the formula itself is extracted. The confusion about the denominator of the sample variance being n ¡ 1 is also addressed. Some properties of the sample mean and varianceof normal data are carefully explained. Pointing out these and other properties in classrooms may have significant effects on the understanding and the retention of the concept.


1980 ◽  
Vol 23 (3) ◽  
pp. 630-645 ◽  
Author(s):  
Gerald Zimmermann ◽  
J.A. Scott Kelso ◽  
Larry Lander

High speed cinefluorography was used to track articulatory movements preceding and following full-mouth tooth extraction and alveoloplasty in two subjects. Films also were made of a control subject on two separate days. The purpose of the study was to determine the effects of dramatically altering the structural dimensions of the oral cavity on the kinematic parameters of speech. The results showed that the experimental subjects performed differently pre and postoperatively though the changes were in different directions for the two subjects. Differences in both means and variabilities of kinematic parameters were larger between days for the experimental (operated) subjects than for the control subject. The results for the Control subject also showed significant differences in the mean values of kinematic variables between days though these day-to-day differences could not account for the effects found pre- and postoperatively. The results of the kinematic analysis, particularly the finding that transition time was most stable over the experimental conditions for the operated subjects, are used to speculate about the coordination of normal speech.


1969 ◽  
Vol 14 (9) ◽  
pp. 470-471
Author(s):  
M. DAVID MERRILL
Keyword(s):  

1972 ◽  
Vol 28 (03) ◽  
pp. 447-456 ◽  
Author(s):  
E. A Murphy ◽  
M. E Francis ◽  
J. F Mustard

SummaryThe characteristics of experimental error in measurement of platelet radioactivity have been explored by blind replicate determinations on specimens taken on several days on each of three Walker hounds.Analysis suggests that it is not unreasonable to suppose that error for each sample is normally distributed ; and while there is evidence that the variance is heterogeneous, no systematic relationship has been discovered between the mean and the standard deviation of the determinations on individual samples. Thus, since it would be impracticable for investigators to do replicate determinations as a routine, no improvement over simple unweighted least squares estimation on untransformed data suggests itself.


2020 ◽  
Vol 1 (2) ◽  
pp. 56-66
Author(s):  
Irma Linda

Background: Early marriages are at high risk of marital failure, poor family quality, young pregnancies at risk of maternal death, and the risk of being mentally ill to foster marriage and be responsible parents. Objective: To determine the effect of reproductive health education on peer groups (peers) on the knowledge and perceptions of adolescents about marriage age maturity. Method: This research uses the Quasi experimental method with One group pre and post test design, conducted from May to September 2018. The statistical analysis used in this study is a paired T test with a confidence level of 95% (α = 0, 05). Results: There is an average difference in the mean value of adolescent knowledge between the first and second measurements is 0.50 with a standard deviation of 1.922. The mean difference in mean scores of adolescent perceptions between the first and second measurements was 4.42 with a standard deviation of 9.611. Conclusion: There is a significant difference between adolescent knowledge on the pretest and posttest measurements with a value of P = 0.002, and there is a significant difference between adolescent perceptions on the pretest and posttest measurements with a value of p = 0.001. Increasing the number of facilities and facilities related to reproductive health education by peer groups (peers) in adolescents is carried out on an ongoing basis at school, in collaboration with local health workers as prevention of risky pregnancy.


1982 ◽  
Vol 47 (7) ◽  
pp. 1973-1978 ◽  
Author(s):  
Jiří Karhan ◽  
Zbyněk Ksandr ◽  
Jiřina Vlková ◽  
Věra Špatná

The determination of alcohols by 19F NMR spectroscopy making use of their reaction with hexafluoroacetone giving rise to hemiacetals was studied on butanols. The calibration curve method and the internal standard method were used and the results were mutually compared. The effects of some experimental conditions, viz. the sample preparation procedure, concentration, spectrometer setting, and electronic integration, were investigated; the conditions, particularly the concentrations, proved to have a statistically significant effect on the results of determination. For the internal standard method, the standard deviation was 0.061 in the concentration region 0.032-0.74 mol l-1. The method was applied to a determination of alcohols in the distillation residue from an oxo synthesis.


1988 ◽  
Vol 60 (1) ◽  
pp. 1-29 ◽  
Author(s):  
E. D. Young ◽  
J. M. Robert ◽  
W. P. Shofner

1. The responses of neurons in the ventral cochlear nucleus (VCN) of decerebrate cats are described with regard to their regularity of discharge and latency. Regularity is measured by estimating the mean and standard deviation of interspike intervals as a function of time during responses to short tone bursts (25 ms). This method extends the usual interspike-interval analysis based on interval histograms by allowing the study of temporal changes in regularity during transient responses. The coefficient of variation (CV), equal to the ratio of standard deviation to mean interspike interval, is used as a measure of irregularity. Latency is measured as the mean and standard deviation of the latency of the first spike in response to short tone bursts, with 1.6-ms rise times. 2. The regularity and latency properties of the usual PST histogram response types are shown. Five major PST response type classes are used: chopper, primary-like, onset, onset-C, and unusual. The presence of a prepotential in a unit's action potentials is also noted; a prepotential implies that the unit is recorded from a bushy cell. 3. Units with chopper PST histograms give the most regular discharge. Three varieties of choppers are found. Chop-S units (regular choppers) have CVs less than 0.35 that are approximately constant during the response; chop-S units show no adaptation of instantaneous rate, as measured by the inverse of the mean interspike interval. Chop-T units have CVs greater than 0.35, show an increase in irregularity during the response and show substantial rate adaptation. Chop-U units have CVs greater than 0.35, show a decrease in irregularity during the response, and show a variety of rate adaptation behaviors, including negative adaptation (an increase in rate during a short-tone response). Irregular choppers (chop-T and chop-U units) rarely have CVs greater than 0.5. Choppers have the longest latencies of VCN units; all three groups have mean latencies at least 1 ms longer than the shortest auditory nerve (AN) fiber mean latencies. 4. Chopper units are recorded from stellate cells in VCN (35, 42). Our results for chopper units suggest a model for stellate cells in which a regularly firing action potential generator is driven by the summation of the AN inputs to the cell, where the summation is low-pass filtered by the membrane capacitance of the cell.(ABSTRACT TRUNCATED AT 400 WORDS)


Cancers ◽  
2021 ◽  
Vol 13 (10) ◽  
pp. 2421
Author(s):  
Roberta Fusco ◽  
Vincenza Granata ◽  
Mauro Mattace Raso ◽  
Paolo Vallone ◽  
Alessandro Pasquale De Rosa ◽  
...  

Purpose. To combine blood oxygenation level dependent magnetic resonance imaging (BOLD-MRI), dynamic contrast enhanced MRI (DCE-MRI), and diffusion weighted MRI (DW-MRI) in differentiation of benign and malignant breast lesions. Methods. Thirty-seven breast lesions (11 benign and 21 malignant lesions) pathologically proven were included in this retrospective preliminary study. Pharmaco-kinetic parameters including Ktrans, kep, ve, and vp were extracted by DCE-MRI; BOLD parameters were estimated by basal signal S0 and the relaxation rate R2*; and diffusion and perfusion parameters were derived by DW-MRI (pseudo-diffusion coefficient (Dp), perfusion fraction (fp), and tissue diffusivity (Dt)). The correlation coefficient, Wilcoxon-Mann-Whitney U-test, and receiver operating characteristic (ROC) analysis were calculated and area under the ROC curve (AUC) was obtained. Moreover, pattern recognition approaches (linear discrimination analysis and decision tree) with balancing technique and leave one out cross validation approach were considered. Results. R2* and D had a significant negative correlation (−0.57). The mean value, standard deviation, Skewness and Kurtosis values of R2* did not show a statistical significance between benign and malignant lesions (p > 0.05) confirmed by the ‘poor’ diagnostic value of ROC analysis. For DW-MRI derived parameters, the univariate analysis, standard deviation of D, Skewness and Kurtosis values of D* had a significant result to discriminate benign and malignant lesions and the best result at the univariate analysis in the discrimination of benign and malignant lesions was obtained by the Skewness of D* with an AUC of 82.9% (p-value = 0.02). Significant results for the mean value of Ktrans, mean value, standard deviation value and Skewness of kep, mean value, Skewness and Kurtosis of ve were obtained and the best AUC among DCE-MRI extracted parameters was reached by the mean value of kep and was equal to 80.0%. The best diagnostic performance in the discrimination of benign and malignant lesions was obtained at the multivariate analysis considering the DCE-MRI parameters alone with an AUC = 0.91 when the balancing technique was considered. Conclusions. Our results suggest that the combined use of DCE-MRI, DW-MRI and/or BOLD-MRI does not provide a dramatic improvement compared to the use of DCE-MRI features alone, in the classification of breast lesions. However, an interesting result was the negative correlation between R2* and D.


Sign in / Sign up

Export Citation Format

Share Document