scholarly journals Effect of Load Pattern on Cold formed Steel Wall Plate System

Author(s):  
ADELINE NG ◽  
HII WEI ◽  
Mei Chee
2016 ◽  
Vol 858 ◽  
pp. 38-43
Author(s):  
Ng Ling Ying Adeline ◽  
Wei Hui Hii

The paper presents experimental investigations on cold-formed steel (CFS) wall plate system. The behavior and the modes of failure of the system under uplift were studied. The parameters tested were the presence of gaps and the thickness of connecting plates. Results showed that samples with and without gaps at the supports experienced the same failure mode. Failure began with the yielding of connecting plates followed by the buckling of C-channel. Similar ultimate capacity was also obtained for samples with and without gaps. When connecting plates of different thicknesses were used to connect the wall-plate, different modes of failure were observed. Instead of yielding in the connecting plates, screw pull-out was observed in the connection before the C-channel buckled. Besides, it was observed that the ultimate capacity of the system was reduced when thicker connecting plates were used. It is not conservative to estimate the capacity of screwed connection according to the design standard and it is proposed that the capacity of the wall plate system is taken as the yield capacity of the connecting plates of the same material properties.


Alloy Digest ◽  
2017 ◽  
Vol 66 (7) ◽  

Abstract Strenx Section 900 is a cold-formed steel section made of hot-rolled, high-strength steel with a minimum yield strength of 900 MPa (131 ksi). Its high strength combined with naturally stiff form enables construction of stronger and lighter structures. The common shape is a U-bend channel. This datasheet provides information on composition, physical properties, tensile properties, and bend strength as well as fracture toughness. It also includes information on forming, machining, and joining. Filing Code: SA-792. Producer or source: SSAB Swedish Steel Inc..


Author(s):  
Benbouza Naima ◽  
Benfarhi Louiza ◽  
Azoui Boubekeur

Background: The improvement of the voltage in power lines and the respect of the low voltage distribution transformer substations constraints (Transformer utilization rate and Voltage drop) are possible by several means: reinforcement of conductor sections, installation of new MV / LV substations (Medium Voltage (MV), Low Voltage (LV)), etc. Methods: Connection of mini-photovoltaic systems (PV) to the network, or to consumers in underserved areas, is a well-adopted solution to solve the problem of voltage drop and lighten the substation transformer, and at the same time provide clean electrical energy. PV systems can therefore contribute to this solution since they produce energy at the deficit site. Results: This paper presents the improvement of transformer substation constraints, supplying an end of low voltage electrical line, by inserting photovoltaic systems at underserved subscribers. Conclusion: This study is applied to a typical load pattern, specified to the consumers region.


Polymers ◽  
2021 ◽  
Vol 13 (6) ◽  
pp. 889
Author(s):  
Yuhei Matsuda ◽  
Masaaki Karino ◽  
Tatsuo Okui ◽  
Takahiro Kanno

Two second-generation PLLA/PGA bioresorbable osteosynthetic plate systems for oral and maxillofacial surgery are available in Japan. The two systems have different PLLA-PGA component ratios (RapidSorb®, 85:15; Lactosorb®, 82:18) and plate and screw shapes. We conducted a retrospective study to compare our clinical evaluation and examine the incidence of postoperative complications between the two plate systems. A retrospective survey was conducted in 148 patients (midfacial fracture/trauma (68.2%) and dentofacial deformity patients (31.8%); males (54.7%); median age, 37.5 years) treated using maxillofacial osteosynthetic plate systems. The complications included plate exposure (7.4%), infection, (2.7%), and plate breakage (0.7%). Multivariate logistic regression analysis showed a significant correlation between sex (female), plate system (Lactosorb®), number of plates, and pyriform aperture and periorbital sites of plate placement (p < 0.05). Additionally, the propensity score-adjusted model showed a significant correlation between Lactosorb® and postoperative complications (odds ratio 1.007 (95% confidence interval, 1.001–1.055), p < 0.01). However, the two plate systems showed a low incidence rate of complications, and the plate integration and survivability were similar using 2.0-mm or 1.5-mm resorbable plate regardless of the plate system. Our findings suggest that female sex and a greater number of plates are risk factors for postoperative complications, whereas pyriform aperture and periorbital plate placements reduce the risk.


Author(s):  
Baoliang Chen ◽  
Peng Liu ◽  
Feiyun Xiao ◽  
Zhengshi Liu ◽  
Yong Wang

Quantitative assessment is crucial for the evaluation of human postural balance. The force plate system is the key quantitative balance assessment method. The purpose of this study is to review the important concepts in balance assessment and analyze the experimental conditions, parameter variables, and application scope based on force plate technology. As there is a wide range of balance assessment tests and a variety of commercial force plate systems to choose from, there is room for further improvement of the test details and evaluation variables of the balance assessment. The recommendations presented in this article are the foundation and key part of the postural balance assessment; these recommendations focus on the type of force plate, the subject’s foot posture, and the choice of assessment variables, which further enriches the content of posturography. In order to promote a more reasonable balance assessment method based on force plates, further methodological research and a stronger consensus are still needed.


Sign in / Sign up

Export Citation Format

Share Document