scholarly journals Color and Chemical Oxygen Demand (COD) Removal by Bacteria Consortium Using Factorial Design

2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Ali Jalilzadeh ◽  
Ramin Nabizadeh ◽  
Alireza Mesdaghinia ◽  
Aliakbar Azimi ◽  
Simin Nasseri ◽  
...  

A systematic model for chemical oxygen demand (COD) removal using the ANAMMOX (Anaerobic AMMonium OXidation) process was provided based on an experimental design. At first, the experimental data was collected from a combined biological aerobic/anaerobic reactor. For modelling and optimization of COD removal, the main parameters were considered, such as COD loading, ammonium, pH, and temperature. From the models, the optimum conditions were determined as COD 97.5 mg/L, ammonium concentration equal to 28.75 mg-N/L, pH 7.72, and temperature 31.3°C. Finally, the analysis of the optimum conditions, performed by the response surface method, predicted COD removal efficiency of 81.07% at the optimum condition.


Processes ◽  
2019 ◽  
Vol 7 (7) ◽  
pp. 418 ◽  
Author(s):  
Pedro Cisterna-Osorio ◽  
Verónica Lazcano-Castro ◽  
Gisela Silva-Vasquez ◽  
Mauricio Llanos-Baeza ◽  
Ignacio Fuentes-Ortega

The objective of this work is to evaluate the impact of innovative modifications made to conventional effluent capture and discharge devices used in subsurface flow wetlands (SSFW). The main modifications that have been developed extend the influence of the capture and discharge device in such a way that the SSFW width and height are fully covered. This improved innovative device was applied and evaluated in two subsurface flow wetlands, one on a pilot scale and one on a real scale. To evaluate the impact of the innovative device with respect to the conventional one in the operational functioning of subsurface flow wetlands, the elimination of chemical oxygen demand (COD) was measured and compared. The results show that for the innovative device, the COD removal was 10% higher than for the conventional device, confirming the validity and effectiveness of the modifications implemented in the effluent capture and discharge devices used in SSFW.


Water ◽  
2020 ◽  
Vol 12 (9) ◽  
pp. 2532
Author(s):  
Can He ◽  
Jianbing Wang ◽  
Heng Xu ◽  
Xiangyu Ji ◽  
Weiyi Wang ◽  
...  

In this work, the treatment of bio-treated coking wastewater (BCW) by catalytic ozonation was conducted in semi-batch and continuous flow reactors. The kinetics of chemical oxygen demand (COD) removal were analyzed using BCWs from five coking plants. An integral reactor with catalytic ozonation stacked by ozone absorption (IR) was developed, and its efficiency was studied. The catalyst of MnxCe1-xO2/γ-Al2O3 was efficient in the catalytic ozonation process for the treatment of various BCWs. The chemical oxygen demand (COD) removal efficiencies after 120 min reaction were 64–74%. The overall apparent reaction rate constants were 0.0101–0.0117 min−1, which has no obvious relationship with the initial COD of BCW and pre-treatment biological process. The IR demonstrated the highest efficiency due to the enhancement of mass transfer and the utilization efficiency of ozone. Bypass internal circulation can further improve the reactor efficiency. The optimal results were obtained with the ozone absorption section accounting for 19% of the valid water depth in the reactor and 250% of circulation flow ratio. The long-term and full-scale application of the novel reactor in a continuous mode indicated stable removal of COD and polycyclic aromatic hydrocarbons (PAHs). The results showed that the system of IR is a promising reactor type for tertiary treatment of coking wastewater by catalytic ozonation.


2010 ◽  
Vol 62 (11) ◽  
pp. 2669-2677 ◽  
Author(s):  
Lizhang Wang ◽  
Yuemin Zhao

Experiments were performed to reduce chemical oxygen demand (COD) from 4,4′-diaminostilbene-2,2′-disulfonic (DSD) acid manufacturing wastewater using electrochemical oxidation coupled with adsorption by granular activated carbon. The COD removal is affected by the residence time and applied voltage. When the residence time is increased, lower value of COD effluent could be obtained, however, the average current efficiency (ACE) decreased rapidly, and so does the applied voltage. In addition, aeration could effectively enhance COD removal efficiency and protect anodes from corrosion. Furthermore, the acidic condition is beneficial to the rapid decrease of COD and the values of pH effluent are independent of the initial solution pH. The optimization conditions obtained from these experiments are applied voltage of 4.8 V, residence time of 180 min and air–liquid ratio of 4.2 with the COD effluent of about 690 mg L−1. In these cases, the ACE and energy consumption are 388% and 4.144 kW h kg−1 COD, respectively. These perfect results from the experiments illustrate that the combined process is a considerable alternative for the treatment of industrial wastewater containing high concentration of organic pollutants and salinity.


Molecules ◽  
2019 ◽  
Vol 24 (24) ◽  
pp. 4436 ◽  
Author(s):  
Zhiyong Yang ◽  
Penglei Wang ◽  
Yagang Zhang ◽  
Xingjie Zan ◽  
Wenjuan Zhu ◽  
...  

Polymerization mother liquid (PML) is one of the main sources of wastewater in the chlor-alkali industry. The effective degradation of the PML produced in PVC polymerization using three or five ozone reactors in tandem was designed with a focus on improving the ozonation efficiency. The ozonation efficiency of the tandem reactors for the degradation of PML, along with the effect of ozone concentration, the number of reactors utilized in series, and the reaction time on the chemical oxygen demand (COD) removal were investigated in detail. The results showed that the COD removal increased as the ozone concentration was increased from 10.6 to 60 mg·L−1, achieving 66.4% COD removal at ozone concentration of 80.6 mg·L−1. However, when the ozone concentration was increased from 60 mg·L−1 to 80 mg·L−1, the COD removal only increased very little. The COD decreased with increasing ozone concentration. During the initial degradation period, the degradation rate was the highest at both low and high ozone concentrations. The degradation rate decreased with reaction time. The rate at a low ozone concentration decreased more significantly than at high ozone concentration. Although high ozone concentration is desirable for COD removal and degradation rate, the utilization efficiency of ozone decreased with increasing ozone concentration. The ozone utilization efficiency of the five-reactor device was three times higher than that of three tandem reactors, demonstrating that ozonation utilization efficiency can be improved by increasing the number of tandem reactors. Ozonation in tandem reactors is a promising approach for PML treatment.


Author(s):  
Pedro Cisterna-Osorio ◽  
Gisela Silva-Vasquez ◽  
Mauricio Llanos-Baeza ◽  
Veronica Lazcano-Castro ◽  
Felipe Fuentes-Ortega

The objective of this work is to evaluate the impact of the innovative modifications made to the conventional effluent capture and discharge devices used in subsurface flow wetlands (SSFW). The main modifications developed consist on extending the influence of the capture and discharge device in such a way that the SSFW width and height are fully covered. This improved innovative device was applied and evaluated in two subsurface flow wetlands, one on a pilot scale and one on a real scale. To evaluate the impact of the innovative device with respect to conventional one in the operational functioning of subsurface flow wetlands, the elimination of chemical oxygen demand was measured and compared. The results show that for the innovative device, the COD removal was 10% higher than for the conventional device, confirming the validity and effectiveness of the modifications implemented in the effluent capture and discharge devices used in SSFW.


2021 ◽  
Vol 2 (1) ◽  
pp. 8-17
Author(s):  
Sukanya Pujari ◽  
Manoj Wagh ◽  
Shila Dare

In waste treatment and water management issues, electrocoagulation (EC) is the most cost-effective and environmentally friendly option. In the study, EC treatment of distillery spent wash was carried out using new electrodes packed with aluminium foil scraps. These metal scraps were packed in a mesh to function as anode and cathode electrodes. Electrochemical treatment was carried out for 150 minutes, and samples were analysed regularly to determine the colour and chemical oxygen demand (COD). The impact of operating parameters such as pH, applied current, electrolysis time, agitation speed, and electrode distance on colour and COD removal was investigated. The EC processes were carried out in monopolar parallel (MP-P) and monopolar series (MP-S). The MP-S connection measured the potential difference between the amplified pair of electrodes, whereas the output signals in the MP-P connection were formed by several input electrodes, resulting in a high removal rate. The results indicated that the MP-P relationships enhance the COD removal rate by 4.16 to 8.06 %. An optimum chemical oxygen demand degradation is 77.29 % at pH 3, and decolourisation is 76.55 % at pH 8.3. TDS is reduced to a maximum of 58.32 %, while sulfate and chloride are reduced to 64.72 and 20.44 %, respectively.


Author(s):  
Pedro Cisterna-Osorio ◽  
Gisela Silva-Vasquez ◽  
Mauricio Llanos-Baeza ◽  
Veronica Lazcano-Castro ◽  
Ignacio Fuentes-Ortega

The objective of this work is to evaluate the impact of the innovative modifications made to the conventional effluent capture and discharge devices used in subsurface flow wetlands (SSFW). The main modifications developed consist on extending the influence of the capture and discharge device in such a way that the SSFW width and height are fully covered. This improved innovative device was applied and evaluated in two subsurface flow wetlands, one on a pilot scale and one on a real scale. To evaluate the impact of the innovative device with respect to conventional one in the operational functioning of subsurface flow wetlands, the elimination of chemical oxygen demand was measured and compared. The results show that for the innovative device, the COD removal was 10% higher than for the conventional device, confirming the validity and effectiveness of the modifications implemented in the effluent capture and discharge devices used in SSFW.


Sign in / Sign up

Export Citation Format

Share Document