scholarly journals Improved Ozonation Efficiency for Polymerization Mother Liquid from Polyvinyl Chloride Production Using Tandem Reactors

Molecules ◽  
2019 ◽  
Vol 24 (24) ◽  
pp. 4436 ◽  
Author(s):  
Zhiyong Yang ◽  
Penglei Wang ◽  
Yagang Zhang ◽  
Xingjie Zan ◽  
Wenjuan Zhu ◽  
...  

Polymerization mother liquid (PML) is one of the main sources of wastewater in the chlor-alkali industry. The effective degradation of the PML produced in PVC polymerization using three or five ozone reactors in tandem was designed with a focus on improving the ozonation efficiency. The ozonation efficiency of the tandem reactors for the degradation of PML, along with the effect of ozone concentration, the number of reactors utilized in series, and the reaction time on the chemical oxygen demand (COD) removal were investigated in detail. The results showed that the COD removal increased as the ozone concentration was increased from 10.6 to 60 mg·L−1, achieving 66.4% COD removal at ozone concentration of 80.6 mg·L−1. However, when the ozone concentration was increased from 60 mg·L−1 to 80 mg·L−1, the COD removal only increased very little. The COD decreased with increasing ozone concentration. During the initial degradation period, the degradation rate was the highest at both low and high ozone concentrations. The degradation rate decreased with reaction time. The rate at a low ozone concentration decreased more significantly than at high ozone concentration. Although high ozone concentration is desirable for COD removal and degradation rate, the utilization efficiency of ozone decreased with increasing ozone concentration. The ozone utilization efficiency of the five-reactor device was three times higher than that of three tandem reactors, demonstrating that ozonation utilization efficiency can be improved by increasing the number of tandem reactors. Ozonation in tandem reactors is a promising approach for PML treatment.

Water ◽  
2020 ◽  
Vol 12 (9) ◽  
pp. 2532
Author(s):  
Can He ◽  
Jianbing Wang ◽  
Heng Xu ◽  
Xiangyu Ji ◽  
Weiyi Wang ◽  
...  

In this work, the treatment of bio-treated coking wastewater (BCW) by catalytic ozonation was conducted in semi-batch and continuous flow reactors. The kinetics of chemical oxygen demand (COD) removal were analyzed using BCWs from five coking plants. An integral reactor with catalytic ozonation stacked by ozone absorption (IR) was developed, and its efficiency was studied. The catalyst of MnxCe1-xO2/γ-Al2O3 was efficient in the catalytic ozonation process for the treatment of various BCWs. The chemical oxygen demand (COD) removal efficiencies after 120 min reaction were 64–74%. The overall apparent reaction rate constants were 0.0101–0.0117 min−1, which has no obvious relationship with the initial COD of BCW and pre-treatment biological process. The IR demonstrated the highest efficiency due to the enhancement of mass transfer and the utilization efficiency of ozone. Bypass internal circulation can further improve the reactor efficiency. The optimal results were obtained with the ozone absorption section accounting for 19% of the valid water depth in the reactor and 250% of circulation flow ratio. The long-term and full-scale application of the novel reactor in a continuous mode indicated stable removal of COD and polycyclic aromatic hydrocarbons (PAHs). The results showed that the system of IR is a promising reactor type for tertiary treatment of coking wastewater by catalytic ozonation.


2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Ali Jalilzadeh ◽  
Ramin Nabizadeh ◽  
Alireza Mesdaghinia ◽  
Aliakbar Azimi ◽  
Simin Nasseri ◽  
...  

A systematic model for chemical oxygen demand (COD) removal using the ANAMMOX (Anaerobic AMMonium OXidation) process was provided based on an experimental design. At first, the experimental data was collected from a combined biological aerobic/anaerobic reactor. For modelling and optimization of COD removal, the main parameters were considered, such as COD loading, ammonium, pH, and temperature. From the models, the optimum conditions were determined as COD 97.5 mg/L, ammonium concentration equal to 28.75 mg-N/L, pH 7.72, and temperature 31.3°C. Finally, the analysis of the optimum conditions, performed by the response surface method, predicted COD removal efficiency of 81.07% at the optimum condition.


Author(s):  
Vijay A. Juwar ◽  
Ajit P. Rathod

Abstract The present study deals with the treatment of complex waste (WW) treated for removal of chemical oxygen demand (COD) of the food industry by a sono-Fenton process using a batch reactor. The response surface methodology (RSM) was employed to investigate the five independent variables, such as reaction time, the molar ratio of H2O2/Fe2+, volume ratio of H2O2/WW, pH of waste, and ultrasonic density on COD removal. The experimental data was optimized. The optimization yields the conditions: Reaction time of 24 min, HP:Fe molar ratio of 2.8, HP:WW volume ratio of 1.9 ml/L, pH of 3.6 and an ultrasonic density of 1.8 W/L. The predicted value of COD was 91% and the experimental result was 90%. The composite desirability value (D) of the predicted percent of COD removal at the optimized level of variables was close to one (D = 0.991).


Processes ◽  
2019 ◽  
Vol 7 (7) ◽  
pp. 418 ◽  
Author(s):  
Pedro Cisterna-Osorio ◽  
Verónica Lazcano-Castro ◽  
Gisela Silva-Vasquez ◽  
Mauricio Llanos-Baeza ◽  
Ignacio Fuentes-Ortega

The objective of this work is to evaluate the impact of innovative modifications made to conventional effluent capture and discharge devices used in subsurface flow wetlands (SSFW). The main modifications that have been developed extend the influence of the capture and discharge device in such a way that the SSFW width and height are fully covered. This improved innovative device was applied and evaluated in two subsurface flow wetlands, one on a pilot scale and one on a real scale. To evaluate the impact of the innovative device with respect to the conventional one in the operational functioning of subsurface flow wetlands, the elimination of chemical oxygen demand (COD) was measured and compared. The results show that for the innovative device, the COD removal was 10% higher than for the conventional device, confirming the validity and effectiveness of the modifications implemented in the effluent capture and discharge devices used in SSFW.


2011 ◽  
Vol 347-353 ◽  
pp. 1949-1952 ◽  
Author(s):  
Liang Li ◽  
Bing Zhe Xu ◽  
Chang Yu Lin ◽  
Xiao Min Hu

Zidovudine wastewater is difficult to biodegradation due to high COD and toxicity. The synergetic treatment of Zidovudine wastewater by Ultrasonic and iron-carbon micro-electrolysis technology was studied. The influence of initial pH, reaction time, mass ratio of iron and carbon and mass ratio of iron and water on degradation rate of COD was researched. The result showed that the COD removal rate was only about 54.3% and the degradation speed is very slow when iron-carbon micro-electrolysis treated Zidovudine wastewater separately. However, when ultrasonic synergy micro-electrolysis to treat Zidovudine wastewater, the COD removal rate could was up to 85% and the reaction time was also decreased. Moreover, the BOD5 / COD rose from 0.15 to 0.35, which meant the wastewater became easily biodegradable.


2008 ◽  
Vol 2008 ◽  
pp. 1-9 ◽  
Author(s):  
Hinda Lachheb ◽  
Ammar Houas ◽  
Jean-Marie Herrmann

Phenol (PH) and three polynitrophenols (4-nitrophenol (PNP), 2,4-dinitrophenol (DNP), 2,4,6-trinitrophenol (TNP)) were photocatalytically degraded by using titania under either artificial or solar light. These four reactions were chosen as test reactions to compare the efficiencies of two suspended commercial titania photocatalysts (Degussa P-25 and Millennium PC-500). It appears that P-25 has a higher initial efficiency in all nitrophenol disappearance reactions. However, for the overall degradation rate, measured by the chemical oxygen demand (COD) disappearance, the performance of PC-500 was similar to that of P25. This was attributed to a favorable textural effect since PC-500 has a much higher surface area which facilitates the readsorption of intermediates. PC-500 was subsequently supported on a special photoinert paper provided by Ahlstrom Company (38-Pont Evèque, France). The influence of the silica binder used for sticking titania particles on the paper fibers was put in evidence as an inhibitor of the coulombic adsorption of anionic species, especially 2,4,6-trinitrophenol, because of the low pzc of silica. Once validated, this supported photocatalyst was introduced in an autonomous solar pilot photoreactor identical to the several prototypes built in the European AQUACAT program. It was demonstrated that the purification of water could be efficiently obtained in a larger scale without any final tedious filtration.


2010 ◽  
Vol 62 (11) ◽  
pp. 2669-2677 ◽  
Author(s):  
Lizhang Wang ◽  
Yuemin Zhao

Experiments were performed to reduce chemical oxygen demand (COD) from 4,4′-diaminostilbene-2,2′-disulfonic (DSD) acid manufacturing wastewater using electrochemical oxidation coupled with adsorption by granular activated carbon. The COD removal is affected by the residence time and applied voltage. When the residence time is increased, lower value of COD effluent could be obtained, however, the average current efficiency (ACE) decreased rapidly, and so does the applied voltage. In addition, aeration could effectively enhance COD removal efficiency and protect anodes from corrosion. Furthermore, the acidic condition is beneficial to the rapid decrease of COD and the values of pH effluent are independent of the initial solution pH. The optimization conditions obtained from these experiments are applied voltage of 4.8 V, residence time of 180 min and air–liquid ratio of 4.2 with the COD effluent of about 690 mg L−1. In these cases, the ACE and energy consumption are 388% and 4.144 kW h kg−1 COD, respectively. These perfect results from the experiments illustrate that the combined process is a considerable alternative for the treatment of industrial wastewater containing high concentration of organic pollutants and salinity.


2011 ◽  
Vol 356-360 ◽  
pp. 1909-1913 ◽  
Author(s):  
Hong Ai Zheng ◽  
Jian She Liu ◽  
Li Li Pan

Owing to toxicity of pharmacy wastewater to microbe, commonly used biodegradation is often limited in application; accordingly exploiting new ways of the wastewater treatment with high efficiency is a hot topic. As a new efficient advanced oxidation, pulsed corona discharge combining with ozone is attracting more and more attention. In this study, a special reactor was designed, in addition, the removal of TOC(Total Organic Carbon) and COD (Chemical Oxygen Demand)of simulant pharmacy wastewater containing hydroquinone (500mg/L) by pulsed corona discharge combining with ozone were investigated . It was showed that the TOC and COD removal (53.8% and 72.3%) by the combined technology was much higher than by using the two techniques in series when all the samples were treated 40mins.The two methods in combination have a synergistic effect. TOC and COD removal could be improved obviously when NaCl feed concentration increased from 0 to1000 mg/L, yet further increase in NaCl feed led to a markedly decrease removal efficiency of TOC and COD.


Sign in / Sign up

Export Citation Format

Share Document