Microstructure and Composition of Surface Layers Formed by Ion Implantation of Nitrogen in High-Purity Aluminum

1988 ◽  
Vol 100 ◽  
Author(s):  
Robert C. Mccune ◽  
W. T. Donlon ◽  
H. K. Plummer ◽  
L. Toth ◽  
F. W. Kunz

ABSTRACTSurface layers with overall thickness <∼300 nm were produced by ion implantation of N+ or N2+ at energies of 50 or 100 keV in 99.99% pure aluminum. These surfaces were characterized by scanning and transmission electron microscopy, Auger electron spectroscopy, Rutherford backscattering, nuclear reaction analysis and particle-induced X-ray analysis. At doses above 2×1017 N2/cm2 , blistering of the surfaces was observed along with a reduction in the extent of the coulometric dose retained by the material. Oxygen is believed to be introduced into the near-surface region by a process of reaction and ion-beam mixing, as well as possible CO contamination of the beam. A phase, isostructural with AlN, forms semi-coherently with parent aluminum grains, however, some fraction of the metallic aluminum phase remains in the reaction layer, even at overall nitrogen contents which exceed the stoichiometry of AlN.

1994 ◽  
Vol 339 ◽  
Author(s):  
V. Heera ◽  
R. Kögler ◽  
W. Skorupa ◽  
J. Stoemenos

ABSTRACTThe evolution of the damage in the near surface region of single crystalline 6H-SiC generated by 200 keV Ge+ ion implantation at room temperature (RT) was investigated by Rutherford backscattering spectroscopy/chanelling (RBS/C). The threshold dose for amorphization was found to be about 3 · 1014 cm-2, Amorphous surface layers produced with Ge+ ion doses above the threshold were partly annealed by 300 keV Si+ ion beam induced epitaxial crystallization (IBIEC) at a relatively low temperature of 480°C For comparison, temperatures of at least 1450°C are necessary to recrystallize amorphous SiC layers without assisting ion irradiation. The structure and quality of both the amorphous and recrystallized layers were characterized by cross-section transmission electron microscopy (XTEM). Density changes of SiC due to amorphization were measured by step height measurements.


MRS Bulletin ◽  
1987 ◽  
Vol 12 (2) ◽  
pp. 18-21
Author(s):  
C.W. White

Ion beams are used extensively in materials research for processing and synthesis as well as for characterization. In the last few years, enormous advances have been made regarding the use of ion beams for processing or synthesis, and this issue of the MRS BULLETIN will review some of those advances. (The use of ion beams for materials characterization will be the subject of a future issue of the BULLETIN.) The areas covered in this issue are ion implantation, ion beam mixing, ion-assisted deposition, and direct ion beam deposition. For each area, recognized experts in the field prepared overview articles that should be very interesting to those who are not active in the field, and that should be useful to other experts in the field.The first large-scale use of ion beams for materials modification took place in the semiconductor industry more than 20 years ago when ion implantation began to be used to dope the near-surface region of silicon with Group III or Group V dopants. The use of ion implantation in the semiconductor industry has undergone explosive growth, and today almost all electronic devices are fabricated utilizing at lest one ion implantation step.In addition to the semiconductor area, research is being carried out using ion implantation in a multitude of other areas which include ceramics, metals and alloys, insulators, etc. The article on “Ion Implantation” by S.T. Picraux and P.S. Peercy provides an excellent overview of current research activities involving ion implantation of a wide spectrum of materials.


2015 ◽  
Vol 239 ◽  
pp. 149-160
Author(s):  
A.M. Abdul-Kader ◽  
Andrzej Turos

Ion beam bombardment has shown great potential for improving the surface properties of polymers. In this paper, the ion beam-polymer interaction mechanisms are briefly discussed. The main objective of this research was to study the effects of H-ion beam on physico-chemical properties of Ultra-high-molecular-weight polyethylene (UHMWPE) as it is frequently used in biomedical applications. UHMWPE was bombarded with 65 keV H-ions to fluences ranging from 1x1014–2x1016 ions/cm2. Changes of surface layer composition produced by ion bombardment of UHMWPE samples were studied. The hydrogen release and oxygen uptake induced by ion beam bombardment were determined by Nuclear reaction analysis (NRA) using the 1H(15N, αγ)12C and Rutherford backscattering spectrometry (RBS), respectively. Tribological and hardness properties at the polymer near surface region were studied by means of friction coefficient and micro-hardness testers, respectively. Wettability of the bombarded surfaces was determined by measuring the contact angle for distilled water. The obtained results showed that the ion bombardment induced hydrogen release increases with the increasing ion fluence. An important effect observed, was the rapid oxidation of samples, which occurs after exposure of bombarded samples to air. These effects resulted in important modifications of the surface properties of bombarded material such as change of friction coefficient, hardness and improved wettability.


MRS Bulletin ◽  
1987 ◽  
Vol 12 (2) ◽  
pp. 31-39 ◽  
Author(s):  
D.A. Lilienfeld ◽  
L.S. Hung ◽  
J.W. Mayer

In the last quarter of a century, modification of the near-surface region of materials has become of major technological importance. The principal surface modification technique utilized in integrated circuit technology is ion implantation, a technique which has more recently been applied in the metal-processing industry as well. The very high doses required for applications such as increasing the hardness of steel or forming buried oxide layers in silicon have pushed ion implantation to its limits. Ion beam mixing, the intermixing of surface layers by the penetration of energetic ions through them, was developed to overcome these limits. Additionally, ion beam mixing has been able to produce new phases, amorphous and crystalline, which have technologically and scientifically interesting properties.Ion beam mixing was studied extensively in silicide forming systems, due partly to applications to electrical contacts for silicon devices. In intermetallic alloy systems, research has concentrated on determining the interplay between the formation of amorphous and crystalline structures and that between equilibrium and metastable phases. Although over 50 alloy systems have been studied, this article will concentrate on the Al-based alloys. These alloys, particularly the near-noble-metal alloys, demonstrate nearly all the features associated with ion-induced phase formation. Further, Al-rich refractory metal alloys form quasicrystalline icosahe-dral alloys. Ion-beam mixing results parallel those of splat-quenching, the technique first used to produce the fivefold symmetric structure.


Author(s):  
John D. Rubio

The degradation of steam generator tubing at nuclear power plants has become an important problem for the electric utilities generating nuclear power. The material used for the tubing, Inconel 600, has been found to be succeptible to intergranular attack (IGA). IGA is the selective dissolution of material along its grain boundaries. The author believes that the sensitivity of Inconel 600 to IGA can be minimized by homogenizing the near-surface region using ion implantation. The collisions between the implanted ions and the atoms in the grain boundary region would displace the atoms and thus effectively smear the grain boundary.To determine the validity of this hypothesis, an Inconel 600 sample was implanted with 100kV N2+ ions to a dose of 1x1016 ions/cm2 and electrolytically etched in a 5% Nital solution at 5V for 20 seconds. The etched sample was then examined using a JEOL JSM25S scanning electron microscope.


1984 ◽  
Vol 33 ◽  
Author(s):  
D. J. Sharp ◽  
J. K. G. Panitz ◽  
C. H. Seager

ABSTRACTA combination of chemical etching and sheet resistivity measurements showed that intense (1.4 mA/cm2 ) low energy (1400 eV) ion beam hydrogenation of polycrystalline silicon having a columnar structure can produce electrical defect passivation to depths in the order of 100 μm. Transmission electron micrographs disclose surface and near-surface features resulting from the ion beam bombardment which suggest that one of the hydrogen transport mechanisms may be defect induced.


2007 ◽  
Vol 15 (2) ◽  
pp. 26-31 ◽  
Author(s):  
Ben Lich

DualBeam instruments that combine the imaging capability of scanning electron microscopy (SEM) with the cutting and deposition capability of a focused ion beam (FIB) provide biologists with a powerful tool for investigating three-dimensional structure with nanoscale (1 nm-100 nm) resolution. Ever since Van Leeuwenhoek used the first microscope to describe bacteria more than 300 years ago, microscopy has played a central role in scientists' efforts to understand biological systems. Light microscopy is generally limited to a useful resolution of about a micrometer. More recently the use of confocal and electron microscopy has enabled investigations at higher resolution. Used with fluorescent markers, confocal microscopy can detect and localize molecular scale features, but its imaging resolution is still limited. SEM is capable of nanometer resolution, but is limited to the near surface region of the sample.


2007 ◽  
Vol 7 (12) ◽  
pp. 4378-4390 ◽  
Author(s):  
Anuradha Somayaji ◽  
Ramoun Mourhatch ◽  
Pranesh B. Aswath

Tribofilms with thickness ranging from 100–200 nm were developed in-situ during wear tests using a zinc dialkyl dithiophosphates (ZDDP) and fluorinated ZDDP (F-ZDDP). The influence of the antioxidant alkylated diphenyl amine on the formation and properties of these tribofilm is examined. Results indicate that the thickness of the tribofilms formed when F-ZDDP is used is always thicker than the tribofilm formed with ZDDP. In addition, in the presence of antioxidants the tribofilm thickness is increased. The hardness of these tribofilms in the absence of the antioxidants is significantly higher at the near surface region (0–30 nm) when compared to the films formed in the presence of antioxidant. Nanoscratch tests conducted to examine the abrasion resistance of the tribofilms also indicate that the tribofilms formed by F-ZDDP are more resistant to scratch compared to films formed by ZDDP. In the presence of antioxidant, tribofilms formed by F-ZDDP are significantly thicker while both films behave in a similar fashion in nanoscratch tests. Transmission electron microscopy of the wear debris formed during the tests were examined and results indicate the nucleation and growth of nanoparticles of Fe3O4 with an approximate size of 5–10 nm embedded within an otherwise amorphous tribofilm.


2021 ◽  
Vol 47 (2) ◽  
pp. 189-192
Author(s):  
A. V. Voitsekhovskii ◽  
S. N. Nesmelov ◽  
S. M. Dzyadukh ◽  
V. S. Varavin ◽  
S. A. Dvoretskii ◽  
...  

Metals ◽  
2019 ◽  
Vol 9 (2) ◽  
pp. 208 ◽  
Author(s):  
Xinchun Chen ◽  
Xuan Yin ◽  
Jie Jin

To satisfy the harsh service demand of stainless steel and aviation bearing steel, the anticorrosion and wettability behaviors of 9Cr18 stainless steel and M50 bearing steel tailored by ion beam surface modification technology were experimentally investigated. By controlling the ion implantation (F+, N+, N+ + Ti+) or deposition processes, different surface-modified layers and ceramic layers or composite layers with both effects (ion implantation and deposition processes) were obtained on metal surfaces. The wettability was characterized by a contact angle instrument, and the thermodynamics stabilization of ion implantation-treated metals in corrosive solution was evaluated through an electrochemical technique. X-ray photoelectron spectroscopy (XPS) was employed for detecting the chemical bonding states of the implanted elements. The results indicated that ion implantation or deposition-induced surface-modified layers or coating layers could increase water contact angles, namely improving hydrophobicity as well as thermodynamic stabilization in corrosive medium. Meanwhile, wettability with lubricant oil was almost not changed. The implanted elements could induce the formation of new phases in the near-surface region of metals, and the wettability behaviors were closely related to the as-formed ceramic components and amorphous sublayer.


Sign in / Sign up

Export Citation Format

Share Document