scholarly journals TIME HISTORY ANALYSIS OF BUILDING STRUCTURES WITH WATER TANK AS PASSIVE TUNED MASS DAMPER

Author(s):  
J. Sandhya Rani .
2021 ◽  
pp. 107754632110004
Author(s):  
Sanjukta Chakraborty ◽  
Aparna (Dey) Ghosh ◽  
Samit Ray-Chaudhuri

This article presents the design of a tuned mass damper with a conical spring to enable tuning to the natural frequency of the system at multiple values, as may be convenient in case of a system with fluctuations in the mass. The principle and design procedure of the conical spring in the context of a varying mass system are presented. A passive feedback control mechanism based on a simple pulley-mass system is devised to cater to the multi-tuning requirements. A design example of an elevated water tank with fluctuating water content, subjected to ground excitation, is considered to numerically illustrate the efficiency of such a tuned mass damper associated with the conical spring. The conical spring is designed based on the tuning requirements at different mass conditions of the elevated water tank by satisfying the allowable load bearing capacity of the spring. Comparisons are made with the conventional passive tuned mass damper with a linear spring tuned to the full tank condition. Results from time history analysis reveal that the conical spring-tuned mass damper can be successfully designed to remain tuned and thereby achieve significant response reductions under stiffening conditions of the primary structure, whereas the linear spring-tuned mass damper suffers performance degradation because of detuning, whenever there is any fluctuation in the system mass.


2018 ◽  
Vol 2018 ◽  
pp. 1-19 ◽  
Author(s):  
Xiaohan Wu ◽  
Jun Wang ◽  
Jiangyong Zhou

A high four-tower structure is interconnected with a long sky corridor bridge on the top floor. To reduce the earthquake responses and member forces of the towers and sky corridor bridge, a passive control strategy with a friction pendulum tuned mass damper (FPTMD) was adopted. The sky corridor bridge was as the mass of FPTMD. The connection between the towers and the sky corridor bridge was designed as flexible links, where friction pendulum bearings (FPBs) and viscous dampers were installed. Elastoplastic time-history analysis was conducted by using Perform-3D model to look into its seismic behavior under intensive seismic excitation. The optimal design of the FPTMD with varying friction coefficients and radius of friction pendulum bearing (FPB) under seismic excitations was carried out, and the seismic behavior of the structure was also investigated at the same time.Results show that, for this four-tower connected structure, the friction pendulum tuned mass damper (FPTMD) has very well effect on seismic reduction. The structure can meet the seismic resistance design requirements.


2019 ◽  
Vol 8 (3) ◽  
pp. 2263-2269

Latest trend in the development high rise structure demanding taller and lighter structures, which are progressively adaptable with very low damping ratio. As the structures developing vertically, they are ending up all the more affecting by powerful excitation forces, for example, wind and seismic forces. For the more safety of structure and inhabitant's solace, the vibrations of the tall structures become a major issue for both structural designers. So as to control the vibration, various methodologies are proposed out of the few systems accessible for vibration control. Out of numerous methods, TMD has been observed to be increasingly powerful in controlling the dynamic forces caused due to seismic and wind excitations. In this paper, the adequacy of TMD in controlling the dynamic reaction of structures and the impact of different ground movement parameters on the seismic viability of TMD is researched. Essentially, a TMD is a vibratory subsystem appended to a bigger scale host structure so as to lessen the dynamic reactions. The frequency of damper will tuned to essential structure's frequency, so when frequency is high, the damper will results to resonate out of phase along with structural movement. The objective of this work is to study the impact of TMD on the dynamic forces brought about by seismic tremor and wind excitations in standard just as unpredictable in tall RC building structures. For that three 22 story RC building structures are considered with a similar arrangement out of which one ordinary regular structure and the other two are irregular RC structures are demonstrated in Etabs. In irregular RC structures, Stiffness irregularity and torsional irregularity are considered. For assessing seismic and wind reactions of structures, time history analysis, and static analysis used, with and without the tuned mass damper in ETABS. The outcomes acquired from the investigation of three 22 story RC structures with and without tuned mass damper are compared


2017 ◽  
Vol 2017 ◽  
pp. 1-14 ◽  
Author(s):  
Haoxiang He ◽  
Wentao Wang ◽  
Honggang Xu

Due to the eccentric characteristics and the torsional excitation of multidimensional earthquakes, the dynamic response of asymmetry structure involves the translation-torsion coupling vibration and it is adverse to structural performance. Although the traditional tuned mass damper (TMD) is effective for decreasing the translational vibration when the structure is subjected to earthquake, its translation-torsion coupled damping capacity is still deficient. In order to simultaneously control the translational responses and the torsional angle of asymmetry structures, a new type of tuned mass damper with tuned mass blocks, orthogonal poles, and torsional pendulums (TMDPP) is proposed. The translation-torsion coupled vibration is tuned by the movement of the mass blocks and the torsional pendulums. According to the composition and the motion mechanism of the TMDPP, the dynamic equation for the total system considering eccentric torsion effect is established. The damping capacity of the TMDPP is verified by the time history analysis of an eccentric structure, and multidimensional earthquake excitations are considered. The damping effect of the traditional TMD and the TMDPP is compared, and the results show that the performance of TMDPP is superior to the traditional TMD. Moreover, the occasional amplitude amplification in TMD control does not appear in the TMDPP control. The main design parameters which affect the damping performance of TMDPP are analyzed.


2012 ◽  
Vol 446-449 ◽  
pp. 3066-3071 ◽  
Author(s):  
Bin Zhao ◽  
Hui Gao

According to the shake table test results of a high-rising building with large local space, the dynamic characteristics of such structure are complex and the torsional mode becomes the first mode, while the torsional responses under earthquake excitation, especially of the floor just above the large local space, are very remarkable. Special measures are required for such structural system for maintaining its seismic safety. In this research, the bidirectional Tuned Mass Damper (TMD) is employed for reducing the torsional vibration of the high-rising building with large local space. The optimization of the TMD parameters, such as natural frequency, damping ratios and mass ratio, is performed. The time history analysis results indicate that the proposed bidirectional TMD is very effective in torsional vibration control.


Sign in / Sign up

Export Citation Format

Share Document