Histologic Evaluation of a Provisional Implant Retrieved From Man 7 Months After Placement in a Sinus Augmented With Calcium Sulphate: A Case Report

2007 ◽  
Vol 33 (2) ◽  
pp. 89-95 ◽  
Author(s):  
Giovanna Iezzi ◽  
Elisabetta Fiera ◽  
Antonio Scarano ◽  
Gabriele Pecora ◽  
Adriano Piattelli

Abstract Little is known about the in vivo healing processes at the interface of implants placed in different grafting materials. For optimal sinus augmentation, a bone graft substitute that can regenerate high-quality bone and enable the osseointegration of load-bearing titanium implants is needed in clinical practice. Calcium sulphate (CaS) is one of the oldest biomaterials used in medicine, but few studies have addressed its use as a sinus augmentation material in conjunction with simultaneous implant placement. The aim of the present study was to histologically evaluate an immediately loaded provisional implant retrieved 7 months after simultaneous placement in a human sinus grafted with CaS. During retrieval bone detached partially from one of the implants which precluded its use for histologic analysis. The second implant was completely surrounded by native and newly formed bone, and it underwent histologic evaluation. Lamellar bone, with small osteocyte lacunae, was present and in contact with the implant surface. No gaps, epithelial cells, or connective tissues were present at the bone–implant interface. No residual CaS was present. Bone–implant contact percentage was 55% ± 8%. Of this percentage, 40% was represented by native bone and 15% by newly formed bone. CaS showed complete resorption and new bone formation in the maxillary sinus; this bone was found to be in close contact with the implant surface after immediate loading.

2008 ◽  
Vol 21 (03) ◽  
pp. 202-210 ◽  
Author(s):  
J. Langhoff ◽  
J. Mayer ◽  
L. Faber ◽  
S. Kaestner ◽  
G. Guibert ◽  
...  

Summary Objectives: Titanium implants have a tendency for high bone-implant bonding, and, in comparison to stainless steel implants are more difficult to remove. The current study was carried out to evaluate, i) the release strength of three selected anodized titanium surfaces with increased nanohardness and low roughness, and ii) bone-implant bonding in vivo. These modified surfaces were intended to give improved anchorage while facilitating easier removal of temporary implants. Material and methods: The new surfaces were referenced to a stainless steel implant and a standard titanium implant surface (TiMAX™). In a sheep limb model, healing period was 3 months. Bone-implant bonding was evaluated either biomechanically or histologically. Results: The new surface anodized screws demonstrated similar or slightly higher bone-implantcontact (BIC) and torque release forces than the titanium reference. The BIC of the stainless steel implants was significant lower than two of the anodized surfaces (p=0.04), but differences between stainless steel and all titanium implants in torque release forces were not significant (p=0.06). Conclusion: The new anodized titanium surfaces showed good bone-implant bonding despite a smooth surface and increased nanohardness. However, they failed to facilitate implant removal at 3 months.


2021 ◽  
Vol 11 (12) ◽  
pp. 5324
Author(s):  
Maria Menini ◽  
Francesca Delucchi ◽  
Domenico Baldi ◽  
Francesco Pera ◽  
Francesco Bagnasco ◽  
...  

(1) Background: Intrinsic characteristics of the implant surface and the possible presence of endotoxins may affect the bone–implant interface and cause an inflammatory response. This study aims to evaluate the possible inflammatory response induced in vitro in macrophages in contact with five different commercially available dental implants. (2) Methods: one zirconia implant NobelPearl® (Nobel Biocare) and four titanium implants, Syra® (Sweden & Martina), Prama® (Sweden & Martina), 3iT3® (Biomet 3i) and Shard® (Mech & Human), were evaluated. After 4 h of contact of murine macrophage cells J774a.1 with the implants, the total RNA was extracted, transcribed to cDNA and the gene expression of the macrophages was evaluated by quantitative PCR (qPCR) in relation to the following genes: GAPDH, YWHAZ, IL1β, IL6, TNFα, NOS2, MMP-9, MMP-8 and TIMP3. The results were statistically analyzed and compared with negative controls. (3) Results: No implant triggered a significant inflammatory response in macrophages, although 3iT3 exhibited a slight pro-inflammatory effect compared to other samples. (4) Conclusions: All the samples showed optimal outcomes without any inflammatory stimulus on the examined macrophagic cells.


Materials ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2159
Author(s):  
Giovanna Iezzi ◽  
Antonio Scarano ◽  
Luca Valbonetti ◽  
Serena Mazzoni ◽  
Michele Furlani ◽  
...  

Maxillary sinus augmentation is often necessary prior to implantology procedure, in particular in cases of atrophic posterior maxilla. In this context, bone substitute biomaterials made of biphasic calcium phosphates, produced by three-dimensional additive manufacturing were shown to be highly biocompatible with an efficient osteoconductivity, especially when combined with cell-based tissue engineering. Thus, in the present research, osteoinduction and osteoconduction properties of biphasic calcium-phosphate constructs made by direct rapid prototyping and engineered with ovine-derived amniotic epithelial cells or amniotic fluid cells were evaluated. More in details, this preclinical study was performed using adult sheep targeted to receive scaffold alone (CTR), oAFSMC, or oAEC engineered constructs. The grafted sinuses were explanted at 90 days and a cross-linked experimental approach based on Synchrotron Radiation microCT and histology analysis was performed on the complete set of samples. The study, performed taking into account the distance from native surrounding bone, demonstrated that no significant differences occurred in bone regeneration between oAEC-, oAFMSC-cultured, and Ctr samples and that there was a predominant action of the osteoconduction versus the stem cells osteo-induction. Indeed, it was proven that the newly formed bone amount and distribution decreased from the side of contact scaffold/native bone toward the bulk of the scaffold itself, with almost constant values of morphometric descriptors in volumes more than 1 mm from the border.


2020 ◽  
Vol 61 (6) ◽  
pp. 177-187
Author(s):  
Till Kämmerer ◽  
Tony Lesmeister ◽  
Victor Palarie ◽  
Eik Schiegnitz ◽  
Andrea Schröter ◽  
...  

Introduction: We aimed to compare implant osseointegration with calcium phosphate (CaP) surfaces and rough subtractive-treated sandblasted/acid etched surfaces (SA) in an in vivo minipig mandible model. Materials and Methods: A total of 36 cylindrical press-fit implants with two different surfaces (CaP, n = 18; SA, n = 18) were inserted bilaterally into the mandible of 9 adult female minipigs. After 2, 4, and 8 weeks, we analyzed the cortical bone-to-implant contact (cBIC; %) and area coverage of bone-to-implant contact within representative bone chambers (aBIC; %). Results: After 2 weeks, CaP implants showed no significant increase in cBIC and aBIC compared to SA (cBIC: mean 38 ± 5 vs. 16 ± 11%; aBIC: mean 21 ± 1 vs. 6 ± 9%). Two CaP implants failed to achieve osseointegration. After 4 weeks, no statistical difference between CaP and SA was seen for cBIC (mean 54 ± 15 vs. 43 ± 16%) and aBIC (mean 43 ± 28 vs. 32 ± 6). However, we excluded two implants in each group due to failure of osseointegration. After 8 weeks, we observed no significant intergroup differences (cBIC: 18 ± 9 vs. 18 ± 20%; aBIC: 13 ± 8 vs. 16 ± 9%). Again, three CaP implants and two SA implants had to be excluded due to failure of osseointegration. Conclusion: Due to multiple implant losses, we cannot recommend the oral mandibular minipig in vivo model for future endosseous implant research. Considering the higher rate of osseointegration failure, CaP coatings may provide an alternative to common subtractive implant surface modifications in the early phase post-insertion.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Karin Breding ◽  
Ryo Jimbo ◽  
Mariko Hayashi ◽  
Ying Xue ◽  
Kamal Mustafa ◽  
...  

Osseointegration is dependent on implant surface characteristics, including surface chemistry and topography. The presence of nanosized calcium phosphates on the implant surface is interesting to investigate since they affect both the nanotopography and surface chemistry, forming a bone mineral resembling surface. In this work, the osseointegration of titanium implants with and without the presence of hydroxyapatite (HA) nanocrystals has been evaluatedin vivo. The integration was examined using removal torque measurements and real-time polymerase chain reaction (RT-PCR) analysis. The study was performed using two healing time points, 3 and 12 weeks. The results showed that the torque needed to remove the implants was insignificant between the non- and HA-coated implants, both at weeks 3 and 12. The RT-PCR, however, showed significant differences for osteoblast, osteoclast, and proinflammation markers when HA nanocrystals were present.


2008 ◽  
Vol 396-398 ◽  
pp. 179-182 ◽  
Author(s):  
Ana Cristina P. Machado ◽  
Marize Varella de Oliveira ◽  
Robson Pacheco Pereira ◽  
Yasmin R. Carvalho ◽  
Carlos Alberto Alves Cairo

The osseointegration of porous titanium implants was evaluated in the present work. Implants were fabricated from ASTM grade 2 titanium by a powder metallurgy method. Part of these implants were submitted to chemical and thermal treatment in order to deposit a biomimetic coating, aiming to evaluate its influence on the osseointegration of the implants. The implants were characterized by Scanning Electron Microscopy (SEM), Electron Dispersive X-Ray Spectroscopy (EDS) and Raman Spectroscopy. Three coated and three control (uncoated) implants were surgically inserted into thirty albino rabbits’ left and right tibiae, respectively. Tibiae samples were submitted to histological and histomorphometric analyses, utilizing SEM, optical microscopy and mechanical tests. EDS results indicated calcium (Ca) and phosphorous (P) at the surface and Raman spectra exhibited an intense peak, characteristic of hydroxyapatite (HA). Bone neoformation was detected at the bone-implant interface and inside the pores, including the central ones. The mean bone neoformation percentage in the coated implants was statistically higher at 15 days, compared to 30 and 45 days. The mechanical tests showed that coated implants presented higher resistance to displacement, especially after 30 and 45 days.


2008 ◽  
Vol 396-398 ◽  
pp. 385-388
Author(s):  
Paulo Guilherme Coelho ◽  
Marcelo Suzuki

The objective of this series of experiments was to evaluate the effect of bioceramic coatings/ incorporations on implant surfaces as a function of implant and surgical drilling design. Methods: A series of four in vivo studies were conducted utilizing the dog proximal tibia model. The models provided implants that remained from 2 to 5 weeks implantation time. The different studies comprised the placement of implants with intimate contact with bone following placement and implant designs that resulted in healing chambers. The various implant types presented surfaces with and without Ca- and P-based bioceramic incorporations. Biomechanical and histomorphometric measurements along with qualitative bone-implant interface morphology evaluation were performed. For all studies, one-way ANOVA at 95% level of significance was employed along with Tukey's post-hoc multiple comparisons. Results: Close contact between cortical and trabecular bone and all the different implant surfaces irrespective of implant fit (with and without healing chambers) showed that all surfaces were biocompatible and osteoconductive. In general, appositional bone healing was observed at all implant regions that were in intimate contact with bone immediately after placement, and an intramembranous-like healing occurred throughout the whole volume of the healing chambers. Irrespective of implant + surgical drilling design, the presence of Ca and P resulted in a bone morphology that showed primary osteonic structures at earlier times than uncoated surfaces. Conclusion: Irrespective of implant design and surgical drilling combination, the presence of Ca and P on the implant surface positively modulated early healing around endosseous implants.


Author(s):  
B. Musante ◽  
F. Romano ◽  
D. Baldi ◽  
P. Pera ◽  
F. Grillo ◽  
...  

The aim of this study is to investigate the in vivo efficacy of Puros® cancellous particulate allograft bone in the regeneration of post-extractive sites. Twelve molar or premolar sites were selected. Seven days after minimally invasive tooth extraction, Puros® cancellous particulate allografts were inserted into the elected sites. TC Cone-Beam investigation and at 4 months from surgery; bone height and width were evaluated. Five months after surgery, biopsy samples of the regenerated sites were taken and histologically analyzed to qualitatively evaluate bone regeneration. TC analysis showed, a mean bone gain of 4.1 mm in height and 2.02 mm in width. The histological analysis of the samples showed intense bone metabolic activity with active osteoblasts on the implant surface, at the level of the native bone-graft interface and in the grafted area. The radiographic and histological analyses demonstrate an optimal bonen regeneration, both in terms of quality and quantity using Puros®.


2009 ◽  
Vol 7 (42) ◽  
pp. 81-90 ◽  
Author(s):  
Young-Taeg Sul ◽  
Carina Johansson ◽  
Tomas Albrektsson

Quantifying the in vivo interfacial biochemical bond strength of bone implants is a biological challenge. We have developed a new and novel in vivo method to identify an interfacial biochemical bond in bone implants and to measure its bonding strength. This method, named biochemical bond measurement (BBM), involves a combination of the implant devices to measure true interfacial bond strength and surface property controls, and thus enables the contributions of mechanical interlocking and biochemical bonding to be distinguished from the measured strength values. We applied the BBM method to a rabbit model, and observed great differences in bone integration between the oxygen (control group) and magnesium (test group) plasma immersion ion-implanted titanium implants (0.046 versus 0.086 MPa, n =10, p =0.005). The biochemical bond in the test implants resulted in superior interfacial behaviour of the implants to bone: (i) close contact to approximately 2 μm thin amorphous interfacial tissue, (ii) pronounced mineralization of the interfacial tissue, (iii) rapid bone healing in contact, and (iv) strong integration to bone. The BBM method can be applied to in vivo experimental models not only to validate the presence of a biochemical bond at the bone–implant interface but also to measure the relative quantity of biochemical bond strength. The present study may provide new avenues for better understanding the role of a biochemical bond involved in the integration of bone implants.


2012 ◽  
Vol 529-530 ◽  
pp. 475-479 ◽  
Author(s):  
Ruggero Bosco ◽  
Michele Iafisco ◽  
Jeroen van den Beucken ◽  
Sander C.G. Leeuwenburgh ◽  
John A. Jansen

The possibility to develop a bone implant with bioactive aspects and in situ drug-delivery properties, in order to provide local treatment in vivo, is a big challenge. Where conventional surface modifications for bone implants focused on the deposition of ceramic (mostly calcium phosphate, CaP) coatings, current surface engineering approaches attempt to incorporate active features to render bone implant surfaces capable to direct biological performance. Biomimetic apatite nanocrystals (nAp) represent, among the CaPs, an elective material for bone applications and their surface functionalization with drugs allows them to act as a drug-delivery vehicle. Since load-bearing bone implants are increasingly used in patients with compromised health conditions, surface engineering is important to warrant the performance of these implants under such conditions. In view of this, bisphosphonates (BPs) represent a treatment modality for a variety of disorders of bone metabolism associated to bone loss, including Paget's bone disease, osteoporosis, fibrous dysplasia and bone metastases. In this work, we have synthesized and characterized bioinspired nAp and evaluated their functionalization with alendronate. In vitro tests will be used to evaluate the efficacy of the functionalized compound to impede the formation of osteoclasts and to show that alendronate-functionalized nAp can significantly reduce osteoclasteogenesis. Finally, alendronate-functionalized nAp (FnAp) has been deposited on titanium implants via the electrospray deposition technique in order to develop inorganic-organic coatings for bone implants with improved functionality.


Sign in / Sign up

Export Citation Format

Share Document