scholarly journals Shear bond strength of acetone-based one-bottle adhesive systems

2006 ◽  
Vol 17 (1) ◽  
pp. 39-43 ◽  
Author(s):  
Guilherme Carpena Lopes ◽  
Paula C. Cardoso ◽  
Luiz Clovis Cardoso Vieira ◽  
Luiz N. Baratieri ◽  
Karina Rampinelli ◽  
...  

The aim of this study was to assess the shear bond strength of four acetone-based one-bottle adhesive systems to enamel and dentin, and compare to that of an ethanol-based system used as control. Fifty human molars were bisected mesiodistally and the buccal and lingual surfaces were embedded in acrylic resin using PVC cylinders. The buccal surfaces were ground to obtain flat dentin surfaces, while the lingual surfaces were ground to obtain flat enamel surfaces. All specimens were polished up to 600-grit sandpapers and randomly assigned to 5 groups (n=20; 10 dentin specimens and 10 enamel specimens), according to the adhesive system used: One-Step (Bisco); Gluma One Bond (Heraeus Kulzer); Solobond M (Voco); TenureQuik w/F (Den-Mat) and OptiBond Solo Plus (Kerr) (control). Each adhesive system was applied according to the manufacturers' instructions. The respective proprietary hybrid composite was applied in a gelatin capsule (d=4.3mm) and light-cured for 40 s. The specimens were tested in shear strength with an Instron machine at a crosshead speed of 5 mm/min. Bond strengths means were analyzed statistically by one-way ANOVA and Duncan's post-hoc (p£0.05). Shear bond strength means (MPa) (±SD) to enamel and dentin were: Enamel: One-Step=11.3(±4.9); Gluma One Bond=16.3(±10.1); Solobond M=18.9(±4.5); TenureQuik w/F=18.7(±4.5) and OptiBond Solo Plus=16.4(±3.9); Dentin: One-Step=6.4(±2.8); Gluma One Bond=3.0(±3.4); Solobond M=10.6(±4.9); TenureQuik w/F=7.8(±3.9) and OptiBond Solo Plus=15.1(±8.9). In enamel, the adhesive systems had statistically similar bond strengths to each other (p>0.05). However, the ethanol-based system (OptiBond Solo Plus) showed significantly higher bond strength to dentin than the acetone-based systems (p£0.0001). In conclusion, the solvent type (acetone or ethanol) had no influence on enamel bond strength, but had great influence on dentin bonding, which should be taken into account when choosing the adhesive system.

2009 ◽  
Vol 79 (3) ◽  
pp. 564-570 ◽  
Author(s):  
Toshiya Endo ◽  
Rieko Ozoe ◽  
Koichi Shinkai ◽  
Makiko Aoyagi ◽  
Hiroomi Kurokawa ◽  
...  

Abstract Objective: To ascertain the effects of repeated bonding on the shear bond strength of orthodontic brackets bonded with a fluoride-releasing and -recharging adhesive system with a self-etching primer in comparison with two other types of adhesive system. Materials and Methods: A total of 48 premolars were collected and divided equally into three groups of 16. Each group was assigned one of three adhesive systems: Transbond XT, Transbond Plus, or a fluoride-releasing and -recharging adhesive system, Beauty Ortho Bond. Shear bond strength was measured 24 hours after bracket bonding, with the bonding/debonding procedures repeated twice after the first debonding. A universal testing machine was used to determine shear bond strengths, and bracket/adhesive failure modes were evaluated with the adhesive remnant index after each debonding. Results: At every debonding sequence, all of these three adhesive systems had a shear bond strength of 6 MPa, which is a minimum requirement for clinical use. Transbond XT and Transbond Plus had significantly higher mean shear bond strengths than did Beauty Ortho Bond at each debonding. No significant differences in mean bond strength were observed between the three debondings in each adhesive system. Bond failure at the enamel/adhesive interface occurred more frequently in Beauty Ortho Bond than in Transbond XT or Transbond Plus. Conclusions: The fluoride-releasing and -recharging adhesive system with the self-etching primer (Beauty Ortho Bond) had clinically sufficient shear bond strength in repeated bracket bonding; this finding can help orthodontists to decrease the risk of damage to enamel at debonding.


2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
Vajihesadat Mortazavi ◽  
Mohammadhosein Fathi ◽  
Ebrahim Ataei ◽  
Niloufar Khodaeian ◽  
Navid Askari

In this laboratory study shear bond strengths of three filled and one unfilled adhesive systems to enamel and dentine were compared. Forty-eight extracted intact noncarious human mandibular molars were randomly assigned to two groups of 24 one for bonding to enamel and the other for bonding to dentine. Buccal and lingual surfaces of each tooth were randomly assigned for application of each one of filled (Prime & Bond NT (PBNT), Optibond Solo Plus (OBSP), and Clearfil SE Bond (CSEB)) and unfilled (Single Bond (SB)) adhesive systems (n=12). A universal resin composite was placed into the translucent plastic cylinders (3 mm in diameter and 2 mm in length) and seated against the enamel and dentine surfaces and polymerized for 40 seconds. Shear bond strength was determined using a universal testing machine, and the results were statistically analyzed using two-way ANOVA, one-way ANOVA,t-test, and Tukey HSD post hoc test with a 5% level of significance.There were no statistically significant differences in bond strength between the adhesive systems in enamel, but CSEB and SB exhibited significantly higher and lower bond strength to dentine, respectively, than the other tested adhesive systems while there were no statistically significant differences between PBNT and OBSP.


Polymers ◽  
2021 ◽  
Vol 13 (6) ◽  
pp. 910
Author(s):  
Syed Rashid Habib ◽  
Salwa Bajunaid ◽  
Abdulrahman Almansour ◽  
Abdulkarim AbuHaimed ◽  
Muqrin Nasser Almuqrin ◽  
...  

The aim of the present study was to investigate the shear bond strength of five different repair methods and adhesive systems for zirconia (Zr) cores layered with feldspathic porcelain. Seventy-five Zr specimens (10 × 10 × 4 mm3) were prepared, sintered, layered with 2 × 10 × 10 mm3 of feldspathic porcelain, and fired. The ceramic was fractured, and the load recorded using a shear-bond test. Specimens were thermocycled and randomly divided into 5 groups (n = 15/group) based on the repair methods. Composite repair blocks with similar dimensions to the layered ceramic (2 × 10 × 10 mm3) were built according to each repair method. Shear bond strength testing of the specimens with composite built up was carried out using a universal testing machine (Instron®5960, Massachusetts, USA). The shear bond strengths of the adhesive interface between repaired composite and the Zr were recorded for all the test groups. The fractured specimens’ surfaces were examined under a scanning electron microscope (Jeol, Musashino, Akishima, Tokyo, Japan) for evaluation of the type of failure and surface characteristics. Shear bond strength of the veneered ceramic bonded to the Zr for all the test groups was non-significant (ANOVA, p = 0.062). Shear bond strength after the repair revealed significant differences (ANOVA, p = 0.002). Group-C (13.79 ± 1.32) and Group-D (9.77 ± 4.77) showed the highest and lowest shear bond strength values, respectively. Paired Sample T-tests showed significantly lower values (p = 0.000) for the repaired (composite) Zr compared to the layered (ceramic) Zr. Multiple comparisons revealed differences (significant) between the shear bond strength of Group-D with Groups A (p = 0.010) and C (p = 0.003, Post Hoc Tukey test). The repair methods tested showed variations in their respective shear bond strengths. Complete ceramic/zirconia repair systems showed better bonding between the repaired composite and Zr core. The mean shear bond strength for the repaired fractured layered Zr showed acceptable outcomes in terms of clinical perspective, but was, however, unpredictable.


2015 ◽  
Vol 5 (3) ◽  
pp. 153-157
Author(s):  
Manoj Hans ◽  
Abhinav Sharma ◽  
Shashit Shetty

ABSTRACT Background The purpose of this study was to evaluate the shear bond strength (SBS) of two different adhesives to normal and deproteinized dentin at an interval of 24 hours and 6 months. Materials and Methods Sixty human molars were sectioned and embedded in acrylic resin. Enamel was worn out and dentin was exposed over which acid etching was performed and the specimens were divided into 12 groups (n = 10) depending on the adhesive system used, the dentin treatment performed and the length of evaluation. A resin composite was inserted over the prepared area followed by assessment for shear bond strength evaluation. Results The application of Sodium hypochlorite (NaOCl) significantly increased the SBS values of prime and bond NT but for adper single bond it was decreased. The means values of SBS standard deviation (SD) in MPa for adhesive systems with 5% NaOCI for 60 seconds, 120 seconds and without NaOCl treatment were: prime and bond NT = 12.48 (1.25), 13.01 (1.00) and 17.74 (4.26) and for adper single bond = 10.92 (1.65), 10.96 (2.45) and 7.57 (1.45). Shear bond strength after storage time of 6 months was decreased significantly. Conclusion According to the statistical analysis, the results only partly supported the hypotheses and greatly depend on the composition of adhesive system. How to cite this article Sharma A, Shetty S, Hans M. Shear Bond Strength Evaluation of Two Adhesive Systems Applied to Etched and Deproteinized Dentin: A Longitudinal Study. J Contemp Dent 2015;5(3):153-157.


2012 ◽  
Vol 3 (2) ◽  
pp. 150-155
Author(s):  
Eduardo Galera da Silva ◽  
Maria Filomena Rocha Lima Huhtala ◽  
Ana Paula Martins Gomes ◽  
Clovis Pagani ◽  
Carlos Rocha Gomes Torres ◽  
...  

ABSTRACT Aim This in vitro study evaluated the shear bond strength of a chemical resin cement to five adhesive systems in bovine dentin. Materials and methods One hundred and three bovine teeth were divided into five experimental groups (n = 19) and two control groups (n = 4). A flat dentin surface was exposed on each tooth after wet grinding the buccal enamel, in order to apply the adhesive systems (Adper Single Bond, Adper Scotchbond Multi-Purpose, Multi Bond Uno plus Duo, One Step, Prompt L-Pop) to 95 teeth, according to manufacture's instructions. Four teeth were etched with phosphoric acid (negative control) and four teeth were no etched with phosphoric acid (positive control). Light-cured composite blocks were sandblasted before the cementation with C&B Cement (Bisco) over the treated dentin. The specimens were stored in distilled water at 37°C and submitted to the shear bond strength test after 7 days. Results ANOVA and Tukey tests (p = 0.05) demonstrated that Adper Single Bond (7.47 ± 4.37), Adper Scotchbond Multi-Purpose (6.68 ± 5.11) and One Step (7.30 ± 4.29) presented the highest bond strength values. Prompt L-Pop (0.05 ± 0.17) and Multi Bond Uno plus Duo (0.72 ± 1.41) presented the lowest significant bond strength values. Conclusion The shear bond strength of composite resin cylinders cemented with chemically activated resin cement depends on the adhesive system used. Clinical significance Fourth and fifth generation light polymerized bonding systems are indicated when self-polymerizing cements are used. How to cite this article Kubo CH, Caneppele TMF, da Silva EG, Huhtala MFRL, Torres CRG, Pagani C, Gomes APM. Shear Bond Strength of a Chemical Resin Cement to Five Adhesive Systems in Bovine Dentin. World J Dent 2012;3(2):150-155.


2011 ◽  
Vol 36 (5) ◽  
pp. 492-501 ◽  
Author(s):  
B Stawarczyk ◽  
R Hartmann ◽  
L Hartmann ◽  
M Roos ◽  
M Özcan ◽  
...  

SUMMARY This study tested the impact of Gluma Desensitizer on the shear bond strength (SBS) of two conventional (RelyX ARC, Panavia 21) and two self-adhesive (RelyX Unicem, G-Cem) resin luting cements after water storage and thermocycling. Human third molars (N=880) were embedded in acrylic resin. The buccal dentin was exposed. Teeth were randomly divided into four main groups, and the following cements were adhered: 1) RelyX ARC, 2) Panavia 21, 3) RelyX Unicem, and 4) G-Cem. In half of the teeth in each group, dentin was treated with Gluma Desensitizer. In the conventional cement groups, the corresponding etchant and adhesive systems were applied. SBS of the cements was tested after 1 hour (initial); at 1, 4, 9, 16, and 25 days of water storage; and at 1, 4, 9, 16, and 25 days of thermocycling. SBS data were analyzed by one-way analysis of variance (ANOVA); this was followed by the post hoc Scheffé test and a t-test. Overall, the highest mean SBS (MPa) was obtained by RelyX ARC (ranging from 14.6 ± 3.9 to 17.6 ± 5.2) and the lowest by Panavia 21 in combination with Gluma Desensitizer (ranging from 0.0 to 2.9 ± 1.0). All tested groups with and without desensitizer showed no significant decrease after aging conditions compared with baseline values (p>0.05). Only the Panavia 21/Gluma Desensitizer combination showed a significant decrease after 4 days of thermocyling compared with initial values and 1 day thermocycling. Self-adhesive cements with Gluma Desensitizer showed increased SBS after aging conditions (ranging from 7.4 ± 1.4 to 15.2 ± 3) compared with groups without desensitizer (ranging from 2.6 ± 1.2 to 8.8 ± 2.9). No cohesive failures in dentin were observed in any of the test groups. Although self-adhesive cements with and without desensitizer presented mainly adhesive failures after water storage (95.8%) and thermocyling (100%), conventional cement (RelyX ARC) showed mainly mixed failures (90.8% and 89.2%, after water storage and thermocyling, respectively). Application of the Gluma Desensitizer to dentin before cementation had a positive effect on the SBS of self-adhesive cements.


2007 ◽  
Vol 31 (1) ◽  
pp. 35-40 ◽  
Author(s):  
Carla Miranda ◽  
Luiz Henrique Maykot Prates ◽  
Ricardo de Souza Vieira ◽  
Maria Cristina Marino Calvo

The aims of this study were to evaluate the shear bond strength (SBS) of four adhesive systems applied to primary dentin and enamel and verify, after SBS testing, the failure mode of the adhesive interface. Sixty extracted sound primary molars were selected and crowns were sectioned in a mesial-distal direction. Specimens were randomly assigned into two groups (adhesion to enamel and adhesion to dentin) and then subdivided into four subgroups according to the adhesive system (n=15): Scotchbond Multi-Purpose (SMP) – Single Bond (SB) – Clearfil SE Bond (and Adper Prompt LPop (APL) – SBS tests were performed and the obtained values were statistically analyzed using ANOVA and Tukey tests (p<0.05). The failure mode analysis was performed with a Scanning Electron Microscope (XL-30, Philips). SBS mean values on enamel were [MPa (SD)]: SMP – 27.89 (7.49); SB – 23.92 (8.8); CSB – 24.36 (6.69); APL – 25.96 (4.08); and on dentin: SMP – 17.29 (4.25); SB – 18.2 (8.74); CSB – 16.13 (7.14); APL – 6.04 (3.35). The predominant failure mode was cohesive (primarily of the bonding agent). On enamel SBS was statistically similar for all four adhesives. On dentin SBS of APL was lower than the other tested adhesives.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Mariana Almeida Mello Proença ◽  
Karime Tavares Lima da Silva ◽  
Alisson Costa e Silva ◽  
Edilausson Moreno Carvalho ◽  
José Bauer ◽  
...  

Objectives. The aim of this study was to evaluate the shear bond strength of metal brackets bonded with different universal adhesive systems containing 10-MDP and Transbond Plus Self Etching Primer after 20,000 thermal cycles. Materials and Methods. A total of 130 sound bovine teeth were used, which are divided into 5 groups (n = 26) according to the adhesive system used: All-Bond Universal (Bisco), Ambar Universal (FGM), Clearfil Universal Bond (Kuraray), Single Bond Universal (3M/ESPE), and Transbond Plus SEP (3M/ESPE) as control. The adhesives were applied for 20 seconds and bonded with a resin Transbond XT (3M/ESPE). After this, the teeth were submitted to 20,000 cycles at 5°C and 55°C. Afterwards, the shear bond strength test was performed in a universal test machine (Instron 3342). The adhesive remnant index (ARI) was evaluated under a stereomicroscope at 10x magnification and scanning electronic microscopy (SEM, Hitachi 3030). The shear bond strength data were submitted to One-Way ANOVA (α = 0.05) and the ARI to the Kruskal–Wallis test (α = 0.05). Results. Statistical analysis showed that the universal adhesive systems presented mean shear bond strength values similar to Transbond Plus SEP (p<0.05). The universal adhesive presented similar ARI values among them but differed from those of Transbond Plus SEP (p<0.001). Transbond Plus SEP presented a high ARI value when compared with the universal adhesive systems and high demineralization of enamel. Conclusions. The results show that universal adhesive systems may be used for bonding metal brackets if the orthodontist wants to maintain dental enamel health.


10.2341/05-20 ◽  
2006 ◽  
Vol 31 (2) ◽  
pp. 240-247 ◽  
Author(s):  
F. H. O. Mitsui ◽  
A. R. Peris ◽  
A. N. Cavalcanti ◽  
G. M. Marchi ◽  
L. A. F. Pimenta

Clinical Relevance Bond strength is affected by the combination of thermal and mechanical load cycling. However, results vary greatly with the number of mechanical cycles and adhesive system type (total or self-etching).


10.2341/08-58 ◽  
2009 ◽  
Vol 34 (2) ◽  
pp. 181-191 ◽  
Author(s):  
A. Reis ◽  
S. K. Moura ◽  
A. Pellizzaro ◽  
K. Dal-Bianco ◽  
A. M. Andrade ◽  
...  

Clinical Relevance The improvement of resin-enamel bond strengths after using Si-C paper and diamond burs for enamel preparation is material dependent. No degradation of enamel bond strength could be observed for any one-step self-etch adhesive system after 12 months of water storage.


Sign in / Sign up

Export Citation Format

Share Document