scholarly journals Effect of saliva contamination and re-etching time on the shear bond strength of a pit and fissure sealant

2004 ◽  
Vol 12 (3) ◽  
pp. 200-204 ◽  
Author(s):  
Gisele Maria Correr ◽  
Angela S. Caldo-Teixeira ◽  
Roberta Caroline Bruschi Alonso ◽  
Regina Maria Puppin-Rontani ◽  
Mário Alexandre Coelho Sinhoreti ◽  
...  

The aim of this study was to evaluate the effect of saliva contamination (SCT) and re-etching time (RET) on the shear bond strength (SBS) of the Fluroshield sealant. Forty-five extracted third molars were sectioned and flattened until reach an enamel surface area. Then, all samples were etched for 30 sec with 35% phosphoric acid and then they were distributed into 9 groups (n=10) according to SCT and RET (seconds), respectively: G1- control (no SCT and no RET); G2- 30s and 0s; G3- 60s and 0s; G4-30s and 2s; G5- 30s and 5s; G6- 30s and 15s; G7-60s and 2s; G8- 60s and 5s; G9- 60s and 15s. The sealant was applied according to the manufacturer's instructions. The samples were stored in distilled water at 37ºC for 72h and subjected to the SBS test. The results indicated that there was no statistically significant difference between the groups (p>0.05). However, it could be noticed that: 1- the longer the SCT, the lower the SBS values; 2 - the longer the RET, the higher the SBS values. It could be concluded that there was a tendency to the shortest SCT (30s) associated to the longest RET (5 and 15s) to reach similar SBS values for the control group.

2013 ◽  
Vol 1 (2) ◽  
pp. 175
Author(s):  
Bernardo Urbanetto Peres ◽  
Felipe Weidenbach Degrazzia ◽  
Renésio Armindo Ghers ◽  
Fabíola Rossato Arrais ◽  
Vilmar Antonio Ferrazzo

PURPOSE: To evaluate the shear bond strength (SBS) of metallic brackets bonded with Transbond Plus Self-Etching Primer (TPSEP) and Transbond Plus Color Change (TPCC) under contamination with a mixture of saliva and blood. MATERIALS AND METHODS: 42 human premolars were randomly divided into 2 groups (n=21). Group 1 (G1) were bonded under no contamination, and Group 2 (G2) was contaminated with saliva/blood before bonding. Both groups were bonded according to the manufacturer’s instructions and were cleaned with pumice before bonding. The shear bond strength (SBS) tests were performed after 24 hours in distilled water at 37°C and after thermocycling. RESULTS: Both groups showed a homogeneous distribution in the Levene’s test (p>0.05). The main shear bond strength value of G1 was 8.89 MPa with a standard deviation of 2.27; the value for G2 was 6.00 MPa with a standard deviation of 2.62 MPa. There was a significant difference between G1 and G2 (t-student test p<0.05). IRA scores indicated that the main value was IRA 0, and no significant difference (α=0.05) was found between the groups. CONCLUSION: Contamination of blood mixed with saliva significantly decreases the shear bond strength, but even so, the performance is clinically acceptable.


2014 ◽  
Vol 15 (6) ◽  
pp. 688-692 ◽  
Author(s):  
Sukumaran Anil ◽  
Farouk Ahmed Hussein ◽  
Mohammed Ibrahim Hashem ◽  
Elna P Chalisserry

ABSTRACT Objective The purpose of the current in-vivo study was to assess the effect of using 0.12% chlorhexidine (CHX) mouth rinse, before bonding, on shear bond strength of polycarbonate brackets bonded with composite adhesive. Subjects and methods Eighteen orthodontic patients with a mean age 21.41 ± 1.2 years, who were scheduled to have 2 or more first premolars extracted, were included in this study. Patients were referred for an oral prophylaxis program which included, in part, the use of a mouth rinse. Patients were divided into 2 groups, a test group of 9 patients who used 0.12% CHX gluconate mouth rinse twice daily and a control group of 9 patients who used a mouth rinse without CHX, but with same color. After 1 week, polycarbonate brackets were bonded to first premolars with Transbond XT composite adhesive. Premolars were extracted after 28 days and tested for shear bond strength on a universal testing machine. Student's t-test was used to compare shear bond strengths of both groups. Results No statistically significant difference was found in bond strengths’ values between both groups. The test group (with CHX) has mean shear bond strength of 14.21 ± 2.42 MPa whereas the control group (without CHX) revealed a mean strength of 14.52 ± 2.31 MPa. Conclusion The use of 0.12% CHX mouth rinse, for one week before bonding, did not affect the shear bond strength of polycarbonate brackets bonded with Transbond composite. Furthermore, these brackets showed clinically acceptable bond strength. How to cite this article Hussein FA, Hashem MI, Chalisserry EP, Anil S. The Impact of Chlorhexidine Mouth Rinse on the Bond Strength of Polycarbonate Orthodontic Brackets. J Contemp Dent Pract 2014;15(6):688-692.


2016 ◽  
Vol 10 (01) ◽  
pp. 109-115 ◽  
Author(s):  
Mahendran Kavitha ◽  
Sharmila Selvaraj ◽  
Ambica Khetarpal ◽  
Aruna Raj ◽  
Shakunthala Pasupathy ◽  
...  

ABSTRACT Objective: The aim of this study was to investigate the neutralizer effect of antioxidant agents on the bond strength of bleached enamel. Materials and Methods: Sixty enamel slabs were prepared from 60 freshly extracted maxillary central incisors and were divided into six groups. The negative control group received no bleaching treatment and the other groups were bleached with 35% carbamide peroxide (Opalescence Quick; Ultradent, South Jordan, USA). In Group II, composite was built immediately after bleaching and cured without any antioxidants. In Group III, bleached specimens received composite build ups delayed by 1 week. In Groups IV, V, and VI bleached specimens received applications of superoxide dismutase (SOD), sodium ascorbate (SA), and tocopherol solutions, respectively, for 10 min. Following composite bonding, the micro shear bond strength (μSBS) was measured at a speed of 1 mm/min in universal testing machine. Statistical Analysis Used: The μSBS values of all the groups were analyzed using the analysis of variance followed by Tukey honestly significant difference post-hoc test. Results: Bonding of composites to unbleached group (Group I) exhibited the highest mean SBS values and among the antioxidant-treated groups, the highest SBS values were seen with SOD (Group IV) treated samples (23.0040 ± 4.30565 MPa). Conclusions: Application of SA, alpha-tocopherol, and SOD can effectively reverse the bond strength with bleached enamel. SOD gave a comparatively more promising reversal of bond strength than SA and alpha-tocopherol, and deserves further studies.


2015 ◽  
Vol 21 (6) ◽  
pp. 1523-1529 ◽  
Author(s):  
Patricia Makishi ◽  
Rafael R. Pacheco ◽  
Alireza Sadr ◽  
Yasushi Shimada ◽  
Yasunori Sumi ◽  
...  

AbstractShear bond strength (SBS) and the interfacial adaptation (IA) of self-adhesive resin (SAR) composites to dentin were evaluated. Two SARs [Vertise Flow (VTF) and Fusio Liquid Dentin (FLD)] were evaluated and compared with a conventional restorative system [adhesive: OptiBond FL and composite: Herculite Précis (OBF/HP)]. Human third molars were used for SBS testing and IA imaging (n=7) using optical coherence tomography (OCT). Flattened dentin disks were prepared and the composites were applied into molds (2.4 mm diameter) that were positioned on dentin. Samples were subjected to SBS testing and OCT analysis, which considered an increase in signal intensity at the bonded interface as evidence of internal gaps. SBS data were analyzed by one-way analysis of variance and Tukey’s test and IA data (% distribution of high brightness values) by Kruskal–Wallis and Dunn’s test (p≤0.05). No statistically significant difference in SBS was observed between VTF (13.9±3.6 MPa) and FLD (11.3±3.2 MPa), whereas OBF/HP showed higher average strength (27.3±6.1 MPa). However, there was a statistically significant difference in IA when VTF (33.3%) was compared with FLD (1.2%) and OBF/HP (1.5%). The conventional restorative system exhibited superior SBS performance compared with SARs. However, the IA of FLD to dentin had values that were not significantly different from OBF/HP.


2015 ◽  
Vol 16 (10) ◽  
pp. 794-799 ◽  
Author(s):  
Maryam Doozandeh ◽  
Milad Mirmohammadi

ABSTRACT Aim This study evaluated the simultaneous effect of extended etching time and casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) containing paste application on shear bond strength (SBS) of etch-and-rinse adhesive to cariesaffected- dentin (CAD). Materials and methods Fifty human third molars were used; 10 normal in group 1 and 40 caries-affected teeth in groups 2 to 5. In the CAD groups, teeth were randomly assigned into four groups (n = 10). In groups 2 and 4, phosphoric acid etching for 15 and 45 seconds was used and in groups 3 and 5, after 15 or 45 seconds etching respectively, CPP-ACP containing paste (MI paste) was applied for 3 minutes. After rinsing, single bond adhesive system and Z250 composite were used for resin composite build-up in all groups. After storage, SBS test was measured at cross head speed of 0.5 mm/min. Data were analyzed using one/two-way ANOVA and Tukey HSD test (α = 0.05). Results Normal dentin groups showed the highest SBS among different groups. There was a statistically significant difference between different etching times in CAD groups (p < 0.05), but there were no significant differences between SBS of SB adhesive to CAD with or without CPP-ACP pretreated in both etching times. Most of the failure modes were adhesive except in groups 1 and 5 which cohesive failure in composite was also observed. Conclusion The results of our study indicated that extended etching time up to 45 seconds could enhance the SBS of CAD and approach nearly to SBS of normal dentin. Moreover, MI paste pretreatment had not significant effect on SBS of etchand- rinse adhesive in CAD. Clinical significance Simultaneous application of extended etching time and CPP-ACP containing paste may be a suggested method in increasing the SBS of adhesive to CAD. How to cite this article Doozandeh M, Firouzmandi M, Mirmohammadi M. The Simultaneous Effect of Extended Etching Time and Casein Phosphopeptide-Amorphous Calcium Phosphate containing Paste Application on Shear Bond Strength of Etch-and-rinse Adhesive to Caries-affected Dentin. J Contemp Dent Pract 2015;16(10):794-799.


2007 ◽  
Vol 361-363 ◽  
pp. 869-872
Author(s):  
J.R. Kim ◽  
M.R. Jung ◽  
Sang Jin Park ◽  
K.K. Choi

The purpose of this study was to evaluate the effect of different etching times on microtensile bond strength(μTBS) to dentin both initial and after thermocycling with 3 different types of total-etching adhesives. Fifty four teeth were divided into 18 groups according to 3 etching times(5, 15, 25sec), 3 types of adhesives(Scotchbond Multipurpose(SM), Single Bond(SB), One-Step(OS)), and thermocycling(0, 2,000cycles). Following the bonding procedure, the specimens were bonded using Z250 composite. Half of them were not thermocycled (control group) and the others were subjected to 2,000 thermocycle (experimental group) and processed for microtensile bond strength testing. The microtensile bond strength(MPa) by different etching time(5, 15, 25s) was 37.7±9.1, 34.3±10.9 and 30.5±7.5 using Scotchbond Multipurpose(SM), 34.6±10.1, 33.8±7.6, 35.3±9.9 using single bond(SB) and 34.3±7.6, 31.3±8.5, 35.8±11.0 using one step(OS). After 2000 thermocycling the specimens, the microtensile bond strength(MPa) was decreased for all dentin bonding systems tested. But when specimens were bonded with OS, there is no significant difference between microtensile bond strength of the groups with the different etching times(5, 15, 25s) (28.2±7.8a , 29.1±8.6a and 28.2±9.4a). And the microtensile bond strength of the groups using SM, SB was decreased significantly when the etchant was applied for 25 sec(p<0.05). After all, the adhesive durability for dentin could be affected by type of solvents in adhesive and etching time. Especially, extended etching time may deteriorate dentin bond strength when ethanol-based adhesive was used


2014 ◽  
Vol 1025-1026 ◽  
pp. 385-390
Author(s):  
Niwat Anuwongnukroh ◽  
Surachai Dechkunakorn ◽  
Jirawat Arunakol ◽  
Wassana Wichai

One of the problems that often occurred during orthodontic treatment is bracket failure. This is usually the result either of the patient’s accidentally, applying inappropriate forces to the bracket or of a poor bonding technique. Thus, a significant number of teeth have to be rebonded in an orthodontic practice. Objective: The aim of this study was to evaluate the in vitro initial repeated shear bond strength of the three adhesive systems at two and five minutes after placement of a bracket. Materials and Methods: The three bonding agent adhesives are System1+, Rely-a-bond, Unite. Two hundred and forty human premolar teeth were divided into two groups, a control and an experimental group. Each group was further divided into three subgroups for bonding brackets with the three different adhesives. Only the teeth in the experimental group were sequentially bonded and debonded two times with the same adhesive. The teeth in control and experimental groups were tested for shear bond strength (at two and five minutes after the bracket was bonded) with an Instron testing machine. Results: The studies were found that : (1) there were differences between the shear bond strength of each adhesive in the control and experimental group. Unite had the highest shear bond strength followed by Rely-a-bond and System1+ at two minutes and five minutes, (2) the experiment group ( rebonded brackets) had higher shear bond strength than control group and Unite had in significant difference (p<0.05) of initial repeated bond strength with System1+ and Rely-a-bond at two minutes and five minutes and (3) there were mostly significant difference (p<0.05) between repeated shear bond strength at two minutes and repeated shear bond strength at five minutes. Conclusion: There were significant difference of the initial repeated shear bond strength of each adhesive. The orthodontists should be aware of applying force for tooth movement into the repeated bonding brackets.


2012 ◽  
Vol 512-515 ◽  
pp. 1765-1769 ◽  
Author(s):  
Chen Hu ◽  
Long Quan Shao ◽  
Yuan Fu Yi ◽  
Qi Liu ◽  
Bin Deng ◽  
...  

Despite the expanded application for zirconia in restoration dentistry, there is less clear recommendation in the literature regarding the relation between zirconia surface roughness and its shear bond strength to resin cements. The aim of this study was to assess the effect of surface roughness of Cercon zirconia on its shear bond strength to resin cements. 66 Zirconia rectangular specimens (10 mm×10 mm×3 mm) were prepared from Cercon zirconia blocks, finished using a diamond rotary cutting instrument, sintered, and then assigned into 6 groups. The specimens in the first group without polishing were used as control. Other groups were polished against 120#, 240#, 360#, 500# and 600# sand paper after sintered, respectively. Ceramic surface were analyzed by scanning electron microscopy (SEM) and Surface profilometer. 10 samples of each group were bonded with Variolink N resin cements respectively and submitted to shear bond strength test. Shear bond strength was measured and statistically analyzed. The results showed that the population means of 6 groups of samples were not equal. There was no significant difference between control group and 600# sand paper treated group, 500#, 360# and 240# sand paper treated groups (P>0.05), but a significant difference among the other groups (P<0.05). Findings of this study revealed that the shear bond strength might be raised by increasing the surface roughness of Cercon zirconia. Therefore, the surface roughness of Cercon zirconia has an effect on the shear bond strength, but is not the determining factor in clinical use.


Sign in / Sign up

Export Citation Format

Share Document