CAPROSYN*, Another Major Advance in Synthetic Monofilament Absorbable Suture

Author(s):  
Angela Pineros-Fernandez ◽  
David B. Drake ◽  
Pamela A. Rodeheaver ◽  
Deborah L. Moody ◽  
Richard Edlich ◽  
...  
Author(s):  
Wataru KAMIIKE ◽  
Kazuhiro IWASE ◽  
Jun Higaki ◽  
Shoki MIKATA ◽  
Yasushi TANAKA ◽  
...  

1994 ◽  
Vol 144 ◽  
pp. 1-9
Author(s):  
A. H. Gabriel

The development of the physics of the solar atmosphere during the last 50 years has been greatly influenced by the increasing capability of observations made from space. Access to images and spectra of the hotter plasma in the UV, XUV and X-ray regions provided a major advance over the few coronal forbidden lines seen in the visible and enabled the cooler chromospheric and photospheric plasma to be seen in its proper perspective, as part of a total system. In this way space observations have stimulated new and important advances, not only in space but also in ground-based observations and theoretical modelling, so that today we find a well-balanced harmony between the three techniques.


VASA ◽  
2015 ◽  
Vol 44 (6) ◽  
pp. 451-457 ◽  
Author(s):  
Vincenzo Gasbarro ◽  
Luca Traina ◽  
Francesco Mascoli ◽  
Vincenzo Coscia ◽  
Gianluca Buffone ◽  
...  

Abstract. Background: Absorbable sutures are not generally accepted by most vascular surgeons for the fear of breakage of the suture line and the risk of aneurysmal formation, except in cases of paediatric surgery or in case of infections. Aim of this study is to provide evidence of safety and efficacy of the use of absorbable suture materials in carotid surgery. Patients and methods: In an 11 year period, 1126 patients (659 male [58.5 %], 467 female [41.5 %], median age 72) underwent carotid endarterectomy for carotid stenosis by either conventional with primary closure (cCEA) or eversion (eCEA) techniques. Patients were randomised into two groups according to the type of suture material used. In Group A, absorbable suture material (polyglycolic acid) was used and in Group B non-absorbable suture material (polypropylene) was used. Primary end-point was to compare severe restenosis and aneurysmal formation rates between the two groups of patients. For statistical analysis only cases with a minimum period of follow-up of 12 months were considered. Results: A total of 868 surgical procedures were considered for data analysis. Median follow-up was 6 years (range 1-10 years). The rate of postoperative complications was better for group A for both cCEA and eCEA procedures: 3.5 % and 2.0 % for group A, respectively, and 11.8 % and 12.9 % for group B, respectively. Conclusions: In carotid surgery, the use of absorbable suture material seems to be safe and effective and with a general lower complications rate compared to the use of non-absorbable materials.


Author(s):  
Stephen Yablo

Aboutness has been studied from any number of angles. Brentano made it the defining feature of the mental. Phenomenologists try to pin down the aboutness features of particular mental states. Materialists sometimes claim to have grounded aboutness in natural regularities. Attempts have even been made, in library science and information theory, to operationalize the notion. However, it has played no real role in philosophical semantics, which is surprising. This is the first book to examine through a philosophical lens the role of subject matter in meaning. A long-standing tradition sees meaning as truth conditions, to be specified by listing the scenarios in which a sentence is true. Nothing is said about the principle of selection—about what in a scenario gets it onto the list. Subject matter is the missing link here. A sentence is true because of how matters stand where its subject matter is concerned. This book maintains that this is not just a feature of subject matter, but its essence. One indicates what a sentence is about by mapping out logical space according to its changing ways of being true or false. The notion of content that results—directed content—is brought to bear on a range of philosophical topics, including ontology, verisimilitude, knowledge, loose talk, assertive content, and philosophical methodology. The book represents a major advance in semantics and the philosophy of language.


Author(s):  
Dale Chimenti ◽  
Stanislav Rokhlin ◽  
Peter Nagy

Physical Ultrasonics of Composites is a rigorous introduction to the characterization of composite materials by means of ultrasonic waves. Composites are treated here not simply as uniform media, but as inhomogeneous layered anisotropic media with internal structure characteristic of composite laminates. The objective here is to concentrate on exposing the singular behavior of ultrasonic waves as they interact with layered, anisotropic materials, materials which incorporate those structural elements typical of composite laminates. This book provides a synergistic description of both modeling and experimental methods in addressing wave propagation phenomena and composite property measurements. After a brief review of basic composite mechanics, a thorough treatment of ultrasonics in anisotropic media is presented, along with composite characterization methods. The interaction of ultrasonic waves at interfaces of anisotropic materials is discussed, as are guided waves in composite plates and rods. Waves in layered media are developed from the standpoint of the "Stiffness Matrix", a major advance over the conventional, potentially unstable Transfer Matrix approach. Laminated plates are treated both with the stiffness matrix and using Floquet analysis. The important influence on the received electronic signals in ultrasonic materials characterization from transducer geometry and placement are carefully exposed in a dedicated chapter. Ultrasonic wave interactions are especially susceptible to such influences because ultrasonic transducers are seldom more than a dozen or so wavelengths in diameter. The book ends with a chapter devoted to the emerging field of air-coupled ultrasonics. This new technology has come of age with the development of purpose-built transducers and electronics and is finding ever wider applications, particularly in the characterization of composite laminates.


Author(s):  
Keisuke Oyama ◽  
Shin Nakahira ◽  
Sakae Maeda ◽  
Akihiro Kitagawa ◽  
Yuki Ushimaru ◽  
...  

AbstractDiaphragmatic resection may be required beneath the diaphragm in some patients with liver tumors. Laparoscopic diaphragmatic resection is technically difficult to secure in the surgical field and in suturing. We report a case of successful laparoscopic hepatectomy with diaphragmatic resection. A 48-year-old man who underwent laparoscopic partial hepatectomy for liver metastasis of rectal cancer 20 months ago underwent surgery because of a new hepatic lesion that invaded the diaphragm. The patient was placed in the left hemilateral decubitus position. The liver and diaphragm attachment areas were encircled using hanging tape. Liver resection preceded diaphragmatic resection with the hanging tape in place. Two snake retractors were used to secure the surgical field for the inflow of CO2 into the pleural space after diaphragmatic resection. The defective part of the diaphragm was repaired using continuous or interrupted sutures. Both ends of the suture were tied with an absorbable suture clip without ligation. In laparoscopic liver resection with diaphragmatic resection, the range of diaphragmatic resection can be minimized by performing liver resection using the hanging method before diaphragmatic resection. The surgical field can be secured using snake retractors. Suturing with an absorbable suture clip is conveniently feasible.


2021 ◽  
Vol 10 (11) ◽  
pp. 2461
Author(s):  
José María Mora-Gutiérrez ◽  
María A. Fernández-Seara ◽  
Rebeca Echeverria-Chasco ◽  
Nuria Garcia-Fernandez

Renal magnetic resonance imaging (MRI) techniques are currently in vogue, as they provide in vivo information on renal volume, function, metabolism, perfusion, oxygenation, and microstructural alterations, without the need for exogenous contrast media. New imaging biomarkers can be identified using these tools, which represent a major advance in the understanding and study of the different pathologies affecting the kidney. Diabetic kidney disease (DKD) is one of the most important diseases worldwide due to its high prevalence and impact on public health. However, its multifactorial etiology poses a challenge for both basic and clinical research. Therefore, the use of novel renal MRI techniques is an attractive step forward in the comprehension of DKD, both in its pathogenesis and in its detection and surveillance in the clinical practice. This review article outlines the most promising MRI techniques in the study of DKD, with the purpose of stimulating their clinical translation as possible tools for the diagnosis, follow-up, and monitoring of the clinical impacts of new DKD treatments.


Author(s):  
Niamh Carey ◽  
Conor Hickey ◽  
Laura Mc Cullagh ◽  
Michael Barry

IntroductionIn 2018, the National Centre for Pharmacoeconomics (NCPE) was commissioned to conduct a health technology assessment (HTA) of one of the first commercially available chimeric antigen receptor (CAR) T-cell therapies, tisagenlecleucel. CAR T-cells are a major advance in personalized cancer treatment, demonstrating promising outcomes in relapsed/refractory pediatric acute lymphoblastic leukemia (pALL). However, the results are based on short-term follow up, limiting their value in predicting long-term survival and leading to uncertainty about the most appropriate survival modeling method to employ. This study aimed to address these limitations by means of expert elicitation.MethodsAn expert elicitation method, the histogram technique, was employed. A predefined discrete numerical scale was presented in Microsoft Excel® and the expert was asked to place twenty crosses on a frequency chart. These crosses represented the expert's beliefs about the distribution of particular quantities. Each cross represented five percent of the probabilistic distribution. Individual distributions were then aggregated across experts using linear pooling.ResultsA total of seventeen experts were invited to take part; eight agreed to participate and five completed the exercise. Three experts did not consider tisagenlecleucel to be a “curative” therapy because patients had a higher risk of death, compared with the age- and sex-matched general population. The aggregated distributions indicated the five-year overall survival rate to be thirty-three percent (95% CI 8.65–56.88) in patients who do not receive a subsequent stem cell transplant and twenty percent (95% CI 2.38 -52.04) in those who do.ConclusionsThe results of this study will be used to calibrate CD19 CAR T-cell therapy survival estimates presented in HTA submissions to the NCPE to ensure more robust assessments. They will also be used to inform the construction of a de novo cost-utility model for examining the cost effectiveness of CD19 CAR T-cell therapies for relapsed/refractory pALL in the Irish healthcare setting.


2019 ◽  
Vol 5 (1) ◽  
Author(s):  
Hikaru Watanabe ◽  
Kohei Abe ◽  
Naoki Kanauchi

Abstract Background It is uncommon for a bronchial stump-related complication to develop during the remote postoperative period in a case of obstructive pneumonia owing to migration of the suture material. Here, we describe a case of bronchial obstructive pneumonia that developed owing to migration of the suture material in the airway 8 years after pulmonary resection. Case presentation A 34-year-old woman underwent left lower lobectomy for a pulmonary carcinoid tumor (pT1bN0M0-stage IA) in 2010. She experienced obstructive pneumonia, and chest computed tomography revealed a mass protruding from the bronchial stump to the bronchial lumen in 2018. After treatment for pneumonia, flexible bronchoscopy showed the presence of a fibrous suture material (Teflon pledget) completely obstructing the left second carina. A week later, the Teflon pledget obstructing the bronchial lumen was removed using a flexible bronchoscope with the patient under general anesthesia. The procedure was completed without removing the small amount of granulation tissue because the bronchial lumen opened after removing the Teflon pledget. She has remained asymptomatic for 1 year after removal. Conclusions In this case, the complication of obstructive pneumonia developed owing to migration of the non-absorbable suture materials used to suture the bronchial stump. Bronchoscopic management of this rare complication comprised endobronchial removal with the patient under general anesthesia. Given our experience with this case, we believe that such conservative management should allow for excellent results in most instances and avoid the need for reoperation.


Sign in / Sign up

Export Citation Format

Share Document