scholarly journals Distribution System Restoration Based On Optimized Heuristic Search Method

Author(s):  
Akba Zoheer Mohammed

Service recovery is still among the most essential approaches to enhance the durability of their contemporary distribution system. Following the error location is identified and isolated; a correct SR program ought to be ascertained to resupply out-of-service places. 2 heuristic approaches are suggested to locate an efficient and speedy solution in contemporary power supply systems. For resolving the support recovery issue in distribution systems, change selection indices sectionalizes switch stated by an analytic plan in addition to a practicable optimized heuristic graph-based process are given. The formulation of the issue includes four different functions like optimizing the complete load restored and cutting back the amount of changing operations. Maximizing the best priority restored loading, also decreasing load decreasing. A nice evaluation of change indices is used for many player tie sticks from the apparatus to think about the ideal solution and minimize the complete quantity of shifting operations. A brand new graph-based program may be used for hunting the best sectionalizes change and diminishing the voltage fall. The precision as well as the validity of this process are analyzed in two regular electrical supply procedures. The outcomes of these suggested methods are utilized for IEEE regular bus test instance.

2020 ◽  
Vol 10 (22) ◽  
pp. 8219
Author(s):  
Andrea Menapace ◽  
Ariele Zanfei ◽  
Manuel Felicetti ◽  
Diego Avesani ◽  
Maurizio Righetti ◽  
...  

Developing data-driven models for bursts detection is currently a demanding challenge for efficient and sustainable management of water supply systems. The main limit in the progress of these models lies in the large amount of accurate data required. The aim is to present a methodology for the generation of reliable data, which are fundamental to train anomaly detection models and set alarms. Thus, the results of the proposed methodology is to provide suitable water consumption data. The presented procedure consists of stochastic modelling of water request and hydraulic pipes bursts simulation to yield suitable synthetic time series of flow rates, for instance, inlet flows of district metered areas and small water supply systems. The water request is obtained through the superimposition of different components, such as the daily, the weekly, and the yearly trends jointly with a random normal distributed component based on the consumption mean and variance, and the number of users aggregation. The resulting request is implemented into the hydraulic model of the distribution system, also embedding background leaks and bursts using a pressure-driven approach with both concentrated and distributed demand schemes. This work seeks to close the gap in the field of synthetic generation of drinking water consumption data, by establishing a proper dedicated methodology that aims to support future water smart grids.


Author(s):  
Isaac G. Musaazi ◽  
Jotham I. Sempewo ◽  
Mohammed Babu ◽  
Nicholas Kiggundu

Abstract Fluctuations in the network pressure of water supply systems affect hydraulic performance and water meter accuracy. The development of metering error curves requires steady-state conditions which are extremely rare in water distribution systems characterized by intermittent supply. Simple deterministic models are suggested and developed from monthly data collected over a 4-year period (2010–2014) for three most dominant meter models (Models 1–3) in the Kampala Water Distribution System (KWDS), Uganda. This study combines pressure and billing information at the same time to understand metering accuracy. Results showed that metering accuracy increased by 4.2, 8.4 and 2.9% when pressure was increased from 10 to 50 m for Models 1–3, respectively. Age did not influence the impact of pressure on meter accuracy. The most sensitive parameter in the model was the meter age. Metering accuracy was relatively constant after a period of 5 years. The least sensitive parameter was the working pressure which caused a slight change to the annual billed volume. The ability of the model to accurately predict the meter registration degenerated with an increasing annual billed volume. Model 2 meters were the best performing and probably the most suitable meters in the KWDS.


2019 ◽  
Vol 91 ◽  
pp. 07016
Author(s):  
Elena Solovyeva

This article analyzes the causes of accidents on overhead gas pipelines. Special attention is paid to the operating conditions of gas distribution and gas consumption systems. The main measures aimed at reducing the environmental danger of gas supply systems operation have been identified. The main methods of increasing the reliability of gas distribution systems in the design of gas networks are considered. The complex index of reliability of gas distribution systems is used, which allows choosing the optimal version of the gas supply system.


Author(s):  
Gunjan Varshney ◽  
Durg S. Chauhan ◽  
Madhukar P. Dave ◽  
Nitin

Background: In modern electrical power distribution systems, Power Quality has become an important concern due to the escalating use of automatic, microprocessor and microcontroller based end user applications. Methods: In this paper, power quality improvement has done using Photovoltaic based Distribution Static Compensator (PV-DSTATCOM). Complete simulation modelling and control of Photovoltaic based Distribution Static Compensator have been provided in the presented paper. In this configuration, DSTATCOM is fed by solar photovoltaic array and PV module is also helpful to maintain the DC link voltage. The switching of PV-STATCOM is controlled by Unit template based control theory. Results: The performance of PV-DSTATCOM has been evaluated for Unity Power Factor (UPF) and AC Voltage Control (ACVC) modes. Here, for studying the power quality issues three-phase distribution system is considered and results have been verified through simulation based on MATLAB software. Conclusion: Different power quality issues and their improvement are studied and presented here for harmonic reduction, DC voltage regulation and power factor correction.


Mathematics ◽  
2018 ◽  
Vol 6 (9) ◽  
pp. 158
Author(s):  
Farzaneh Pourahmadi ◽  
Payman Dehghanian

Allocation of the power losses to distributed generators and consumers has been a challenging concern for decades in restructured power systems. This paper proposes a promising approach for loss allocation in power distribution systems based on a cooperative concept of game-theory, named Shapley Value allocation. The proposed solution is a generic approach, applicable to both radial and meshed distribution systems as well as those with high penetration of renewables and DG units. With several different methods for distribution system loss allocation, the suggested method has been shown to be a straight-forward and efficient criterion for performance comparisons. The suggested loss allocation approach is numerically investigated, the results of which are presented for two distribution systems and its performance is compared with those obtained by other methodologies.


2010 ◽  
Vol 13 (3) ◽  
pp. 419-428 ◽  
Author(s):  
Qiang Xu ◽  
Qiuwen Chen ◽  
Weifeng Li

The water loss from a water distribution system is a serious problem for many cities, which incurs enormous economic and social loss. However, the economic and human resource costs to exactly locate the leakage are extraordinarily high. Thus, reliable and robust pipe failure models are demanded to assess a pipe's propensity to fail. Beijing City was selected as the case study area and the pipe failure data for 19 years (1987–2005) were analyzed. Three different kinds of methods were applied to build pipe failure models. First, a statistical model was built, which discovered that the ages of leakage pipes followed the Weibull distribution. Then, two other models were developed using genetic programming (GP) with different data pre-processing strategies. The three models were compared thereafter and the best model was applied to assess the criticality of all the pipe segments of the entire water supply network in Beijing City based on GIS data.


Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1615
Author(s):  
Mehdi Firouzi ◽  
Saleh Mobayen ◽  
Hossein Shahbabaei Kartijkolaie ◽  
Mojtaba Nasiri ◽  
Chih-Chiang Chen

In this paper, an incorporated bridge-type superconducting fault current limiter (BSFCL) and Dynamic Voltage Restorer (DVR) is presented to improve the voltage quality and limiting fault current problems in distribution systems. In order to achieve these capabilities, the BSFCL and DVR are integrated through a common DC link as a BSFCL-DVR system. The FCL and DVR ports of the BSFCL-DVR system are located in the beginning and end of the sensitive loads’ feeder integrated to the point of common coupling (PCC) in the distribution system. At first, the principle operation of the BSFCL-DVR is discussed. Then, a control system for the BSFCL-DVR system is designed to enhance the voltage quality and limit the fault current. Eventually, the efficiency of the BSFCL-DVR system is verified through the PSCAD/EMTDC simulation.


2021 ◽  
Vol 13 (6) ◽  
pp. 3199
Author(s):  
Laith Shalalfeh ◽  
Ashraf AlShalalfeh ◽  
Khaled Alkaradsheh ◽  
Mahmoud Alhamarneh ◽  
Ahmad Bashaireh

An increasing number of electric vehicles (EVs) are replacing gasoline vehicles in the automobile market due to the economic and environmental benefits. The high penetration of EVs is one of the main challenges in the future smart grid. As a result of EV charging, an excessive overloading is expected in different elements of the power system, especially at the distribution level. In this paper, we evaluate the impact of EVs on the distribution system under three loading conditions (light, intermediate, and full). For each case, we estimate the maximum number of EVs that can be charged simultaneously before reaching different system limitations, including the undervoltage, overcurrent, and transformer capacity limit. Finally, we use the 19-node distribution system to study these limitations under different loading conditions. The 19-node system is one of the typical distribution systems in Jordan. Our work estimates the upper limit of the possible EV penetration before reaching the system stability margins.