scholarly journals Evaluation of a new nomogram for Ferrara ring segment implantation in keratoconus

2021 ◽  
Vol 14 (9) ◽  
pp. 1371-1383
Author(s):  
Joaquín Fernández ◽  
◽  
Antonio Pérez-Rueda ◽  
Sidi Mohamed Hamida Abdelkader ◽  
María José Roig-Revert ◽  
...  

AIM: To evaluate the short-term clinical outcomes of Ferrara rings in keratoconus using an optimized nomogram developed after several years of research and retrospective analysis of clinical data. METHODS: This prospective longitudinal non-comparative clinical trial evaluated 88 eyes of 88 patients (age 18-62y) with keratoconus diagnosis from two Spanish centers. Ferrara ring segment (AJL Ophthalmic) implantation was performed in all cases, using the mechanical procedure in 25 eyes (28.4%) and a femtosecond laser-assisted procedure in 63 eyes (71.6%). The ring segments implanted in each case were selected using a new optimized nomogram that considered variables such as anterior corneal asphericity and astigmatism or the discrepancy among astigmatism and coma orientations. Visual, refractive, corneal topographic, aberrometric, and pachymetric changes after surgery were evaluated during a 3-month follow-up. RESULTS: The implants induced a significant refractive change as well as an improvement in uncorrected (UDVA) and corrected distance visual acuity (CDVA; P<0.001). Postoperative CDVA of 0.10 logMAR or better was achieved in 28.4% and 46.5% of eyes, respectively. Two eyes (2.3%) lost two or more lines of CDVA whereas a total of 53.5% of eyes gained lines of CDVA. A significant central anterior and posterior corneal flattening was induced (P≤0.003), with a significant reduction of anterior (P<0.001) and posterior corneal astigmatisms (P=0.048), and a change in anterior asphericity (P<0.001). Total primary coma (6 mm pupil) change was also statistically significant (preoperative 3.66±3.04 µm vs postoperative 2.33±2.26 µm, P<0.001). No significant differences were found in the effect of ring segments between cases implanted using the mechanical and femtosecond techniques (P≥0.101). CONCLUSION: The implantation of Ferrara rings based on the nomogram evaluated is safe and effective for promoting a visual rehabilitation in keratoconus, with a relevant control of primary coma aberration.

2018 ◽  
Vol 30 (1) ◽  
pp. 139-146 ◽  
Author(s):  
Guilherme Andrade do Nascimento Rocha ◽  
Paulo Ferrara de Almeida Cunha ◽  
Leonardo Torquetti Costa ◽  
Luciene Barbosa de Sousa

Importance: This study shows that a newer long-arc length intrastromal corneal ring segment is efficient and safe for keratoconus treatment. Background: To evaluate visual, tomographic results and complications of a 320-degree intrastromal corneal ring segment implantation with the femtosecond laser for keratoconus treatment. Design: A prospective, nonrandomized, and interventional study. Participants: A total of 34 eyes of 31 patients diagnosed with keratoconus were enrolled. Methods: Patients were divided into two groups based on the strategy used for 320-degree intrastromal corneal ring segment thickness selection. In one group, this selection was based on spherical equivalent (SE group) and in the other on the mean asphericity (Q group). The uncorrected and corrected distance visual acuities, spherical equivalent, K1, K2, Km, Kmax, and mean asphericity ( Q) on corneal tomography were evaluated preoperatively and at 3 and 6 months postoperatively. For astigmatism improvement, we analyzed the corneal tomographic vectorial astigmatism change preoperatively and at 6 months postoperatively. The mean follow-up period was 6.63 ± 0.96 months. Results: The mean uncorrected distance visual acuity and corrected distance visual acuity improved with a significant spherical equivalent improvement ( p < 0.05), with no differences between the 320-degree intrastromal corneal ring segment groups. All corneal tomographic parameters improved significantly ( p < 0.05) between the preoperative and postoperative intervals, with a significant better performance when we used spherical equivalent for the 320-degree intrastromal corneal ring segment thickness selection. Finally, the mean vectorial corneal tomographic astigmatism significantly improved after 6 months, again with no differences between groups. Conclusion: This study suggests that implanting a 320-degree intrastromal corneal ring segment is a safe and effective procedure for treating patients with keratoconus. It also suggests that for thickness selection spherical equivalent is the better strategy.


2018 ◽  
Vol 30 (1) ◽  
pp. 125-131
Author(s):  
Cristina Peris-Martínez ◽  
Inmaculada Bueno-Gimeno ◽  
Izaskun Alvarez-Arana ◽  
David P Piñero ◽  
Andrés Gené-Sampedro

Purpose: To evaluate the visual, refractive, topographic, pachymetric, and biomechanical outcomes after intracorneal ring segment implantation in corneas with post-LASIK ectasia. Methods: Retrospective longitudinal study enrolling 26 eyes of 22 patients with post-LASIK ectasia and undergoing intracorneal ring segment implantation (KeraRing®, Mediphacos) using a 60-kHz femtosecond laser (IntraLase®, IntraLase Corp.) for corneal tunnelization. Visual, refractive, anterior, and posterior corneal topographic (Pentacam HR, Oculus), pachymetric, and corneal biomechanical changes (Ocular response Analyzer, Reichert) were evaluated during a 12-month follow-up. Vector analysis of astigmatic changes was performed. Results: A statistically significant reduction of sphere (p = 0.043) was observed at 1 month after surgery, with a significant improvement of uncorrected distance visual acuity associated (p = 0.019). Likewise, a significant reduction of anterior corneal power measurements (p ⩽ 0.014) and steepest posterior keratometric reading (p = 0.006) were observed at 1 month postoperatively, with no significant changes afterwards (p ⩾ 0.133). No significant changes were observed in manifest cylinder (p ⩾ 0.175), corrected distance visual acuity (p ⩾ 0.174), flattest posterior keratometric measurement (p ⩾ 0.282), volumetric measurements (p ⩾ 0.051), and corneal biomechanical parameters (p ⩾ 0.068). Vector analysis revealed an initial trend to overcorrection of astigmatism, with a trend to undercorrection at the end of follow-up and a significant variability in the outcome achieved in each patient. Conclusion: The implantation of KeraRing segments in post-LASIK corneal ectasia generates a significant modification of spherical refraction and a visual improvement due to a central corneal flattening generated. More refined nomograms of implantation in these cases should be developed to achieve a more predictable correction of astigmatism.


2021 ◽  
Vol 10 (14) ◽  
pp. 3196
Author(s):  
Alba Hernández-Píriz ◽  
Yale Tung-Chen ◽  
David Jiménez-Virumbrales ◽  
Ibone Ayala-Larrañaga ◽  
Raquel Barba-Martín ◽  
...  

There is growing evidence regarding the imaging findings of coronavirus disease 2019 (COVID-19) in lung ultrasounds, however, their role in predicting the prognosis has yet to be explored. Our objective was to assess the usefulness of lung ultrasound in the short-term follow-up (1 and 3 months) of patients with SARS-CoV-2 pneumonia, and to describe the progression of the most relevant lung ultrasound findings. We conducted a prospective, longitudinal and observational study performed in patients with confirmed COVID-19 who underwent a lung ultrasound examination during hospitalization and repeated it 1 and 3 months after hospital discharge. A total of 96 patients were enrolled. In the initial ultrasound, bilateral involvement was present in 100% of the patients with mild, moderate or severe ARDS. The most affected lung area was the posteroinferior (93.8%) followed by the lateral (88.7%). Subpleural consolidations were present in 68% of the patients and consolidations larger than 1 cm in 24%. One month after the initial study, only 20.8% had complete resolution on lung ultrasound. This percentage rose to 68.7% at 3 months. Residual lesions were observed in a significant percentage of patients who recovered from moderate or severe ARDS (32.4% and 61.5%, respectively). In conclusion, lung injury associated with COVID-19 might take time to resolve. The findings in this report support the use of lung ultrasound in the short-term follow-up of patients recovered from COVID-19, as a radiation-sparing, easy to use, novel care path worth exploring.


Vision ◽  
2020 ◽  
Vol 5 (1) ◽  
pp. 1
Author(s):  
Pablo Larco ◽  
Pablo Larco ◽  
Daniel Torres ◽  
David P. Piñero

The short-term safety and efficacy of intracorneal ring segment (ICRS) implantation in keratoconus eyes of children are investigated in this study. A retrospective interventional case series study including a total of 33 keratoconus eyes (age 8 to 17 years) that had undergone ICRS (Keraring segments, Mediphacos) implantation was conducted. Information about visual, refractive, pachymetric, corneal topographic and aberrometric, and corneal endothelial changes during a 3-month follow-up were extracted and analysed. A significant improvement was observed in logMAR corrected distance visual acuity (p = 0.005), combined with a statistically significant reduction in keratometric readings (p < 0.001). A reduction in the magnitude of corneal astigmatism of ≥1 D was observed in 52.8% of eyes. No significant changes were observed in corneal endothelial density (p = 0.317). Significant changes were found in the anterior vertical coma component (p = 0.002) as well as in the spherical aberration of the posterior corneal surface (p = 0.004). Only two relevant complications were described: one corneal microperforation with penetration of the ring segment into the anterior chamber (1 eye, 2.8%), and a case of ring extrusion (1 eye, 2.8%). ICRS implantation in children keratoconus eyes allows a reduction of corneal astigmatism, irregularity, and aberrations, leading to a significant visual improvement.


2021 ◽  
pp. 112067212110006
Author(s):  
Bernardo Kaplan Moscovici ◽  
Pablo Felipe Rodrigues ◽  
Renan Albert Mendonça Rodrigues ◽  
Livia Cristina Rios ◽  
Rosangela Simoncelli ◽  
...  

Objective: To investigate the role of ICRS in halting keratoconus progression in a large sample of patients. Methods: A retrospective, non-comparative, interventional study based on the review of medical records of patients diagnosed with keratoconus who underwent Ferrara corneal ring segment implantation. A retrospective chart analysis study of 123 operated eyes with follow-up ranging from 3 to 16 years (mean 5.3 ± 3.6 years) was performed. This study was carried out at Ocular Surgery Unit, São Paulo, Brazil. All topographic data were obtained from Pentacam (Oculus, Arlington, USA). The same surgeon performed all surgeries, and the Ferrara ICRS nomogram was used for ICRS selection in all cases. Results: Corrected distance visual acuity, keratometry, and topographic astigmatism improved in most cases, with statistical significance. In 42 eyes (53.8%), there was an increase in K1 or K2, and in 36 (46.2%), there was a reduction or maintenance in K1. Considering a difference higher than 1 D, between 3-month post-surgery and final visit (group 3), 32 eyes (41%) showed an increase, and 46 eyes (59%) ended equal or below this value. Conclusion: The implantation of ICRS showed improvement in visual and keratometric indexes. The majority of patients did not increase more than one diopter in keratometric values after ICRS implantation. ICRS may be effective for slowing disease progression, especially in older patients.


Author(s):  
Andreas Prangl-Grötzl ◽  
Armin Ettl ◽  
Robert Hörantner ◽  
Albert Daxer

ABSTRACT Purpose The article aims to study the individual long-term stability of visual acuity after MyoRing treatment of keratoconus. Materials and methods This is a retrospective study of the individual visual acuity development for 5 years after MyoRing implantation for keratoconus. Results In no single case did uncorrected and corrected distance visual acuity lose one line or more during the first 5 years after MyoRing treatment for keratoconus. Moreover, visual acuity was even further ameliorated in most of the cases until the last follow-up period of 5 years after surgery. Conclusion The results indicate that MyoRing placement inside the cornea can achieve both visual rehabilitation and stop of progression of the disease. How to cite this article Prangl-Grötzl A, Ettl A, Hörantner R, Daxer A. Individual Long-term Visual Stability after MyoRing Treatment of Keratoconus. Int J Kerat Ect Cor Dis 2016;5(2):53-56.


2019 ◽  
Vol 28 (3) ◽  
pp. 1039-1052
Author(s):  
Reva M. Zimmerman ◽  
JoAnn P. Silkes ◽  
Diane L. Kendall ◽  
Irene Minkina

Purpose A significant relationship between verbal short-term memory (STM) and language performance in people with aphasia has been found across studies. However, very few studies have examined the predictive value of verbal STM in treatment outcomes. This study aims to determine if verbal STM can be used as a predictor of treatment success. Method Retrospective data from 25 people with aphasia in a larger randomized controlled trial of phonomotor treatment were analyzed. Digit and word spans from immediately pretreatment were run in multiple linear regression models to determine whether they predict magnitude of change from pre- to posttreatment and follow-up naming accuracy. Pretreatment, immediately posttreatment, and 3 months posttreatment digit and word span scores were compared to determine if they changed following a novel treatment approach. Results Verbal STM, as measured by digit and word spans, did not predict magnitude of change in naming accuracy from pre- to posttreatment nor from pretreatment to 3 months posttreatment. Furthermore, digit and word spans did not change from pre- to posttreatment or from pretreatment to 3 months posttreatment in the overall analysis. A post hoc analysis revealed that only the less impaired group showed significant changes in word span scores from pretreatment to 3 months posttreatment. Discussion The results suggest that digit and word spans do not predict treatment gains. In a less severe subsample of participants, digit and word span scores can change following phonomotor treatment; however, the overall results suggest that span scores may not change significantly. The implications of these findings are discussed within the broader purview of theoretical and empirical associations between aphasic language and verbal STM processing.


VASA ◽  
2019 ◽  
Vol 48 (4) ◽  
pp. 321-329
Author(s):  
Mariya Kronlage ◽  
Erwin Blessing ◽  
Oliver J. Müller ◽  
Britta Heilmeier ◽  
Hugo A. Katus ◽  
...  

Summary. Background: To assess the impact of short- vs. long-term anticoagulation in addition to standard dual antiplatelet therapy (DAPT) upon endovascular treatment of (sub)acute thrombembolic occlusions of the lower extremity. Patient and methods: Retrospective analysis was conducted on 202 patients with a thrombembolic occlusion of lower extremities, followed by crirical limb ischemia that received endovascular treatment including thrombolysis, mechanical thrombectomy, or a combination of both between 2006 and 2015 at a single center. Following antithrombotic regimes were compared: 1) dual antiplatelet therapy, DAPT for 4 weeks (aspirin 100 mg/d and clopidogrel 75 mg/d) upon intervention, followed by a lifelong single antiplatelet therapy; 2) DAPT plus short term anticoagulation for 4 weeks, followed by a lifelong single antiplatelet therapy; 3) DAPT plus long term anticoagulation for > 4 weeks, followed by a lifelong anticoagulation. Results: Endovascular treatment was associated with high immediate revascularization (> 98 %), as well as overall and amputation-free survival rates (> 85 %), independent from the chosen anticoagulation regime in a two-year follow up, p > 0.05. Anticoagulation in addition to standard antiplatelet therapy had no significant effect on patency or freedom from target lesion revascularization (TLR) 24 months upon index procedure for both thrombotic and embolic occlusions. Severe bleeding complications occurred more often in the long-term anticoagulation group (9.3 % vs. 5.6 % (short-term group) and 6.5 % (DAPT group), p > 0.05). Conclusions: Our observational study demonstrates that the choice of an antithrombotic regime had no impact on the long-term follow-up after endovascular treatment of acute thrombembolic limb ischemia whereas prolonged anticoagulation was associated with a nominal increase in severe bleeding complications.


VASA ◽  
2012 ◽  
Vol 41 (2) ◽  
pp. 120-124 ◽  
Author(s):  
Asciutto ◽  
Lindblad

Background: The aim of this study is to report the short-term results of catheter-directed foam sclerotherapy (CDFS) in the treatment of axial saphenous vein incompetence. Patients and methods: Data of all patients undergoing CDFS for symptomatic primary incompetence of the great or small saphenous vein were prospectively collected. Treatment results in terms of occlusion rate and patients’ grade of satisfaction were analysed. All successfully treated patients underwent clinical and duplex follow-up examinations one year postoperatively. Results: Between September 2006 and September 2010, 357 limbs (337 patients) were treated with CDFS at our institution. Based on the CEAP classification, 64 were allocated to clinical class C3 , 128 to class C4, 102 to class C5 and 63 to class C6. Of the 188 patients who completed the one year follow up examination, 67 % had a complete and 14 % a near complete obliteration of the treated vessel. An ulcer-healing rate of 54 % was detected. 92 % of the patients were satisfied with the results of treatment. We registered six cases of thrombophlebitis and two cases of venous thromboembolism, all requiring treatment. Conclusions: The short-term results of CDFS in patients with axial vein incompetence are acceptable in terms of occlusion and complications rates.


Crisis ◽  
2003 ◽  
Vol 24 (2) ◽  
pp. 73-78 ◽  
Author(s):  
Yves Sarfati ◽  
Blandine Bouchaud ◽  
Marie-Christine Hardy-Baylé

Summary: The cathartic effect of suicide is traditionally defined as the existence of a rapid, significant, and spontaneous decrease in the depressive symptoms of suicide attempters after the act. This study was designed to investigate short-term variations, following a suicide attempt by self-poisoning, of a number of other variables identified as suicidal risk factors: hopelessness, impulsivity, personality traits, and quality of life. Patients hospitalized less than 24 hours after a deliberate (moderate) overdose were presented with the Montgomery-Asberg Depression and Impulsivity Rating Scales, Hopelessness scale, MMPI and World Health Organization's Quality of Life questionnaire (abbreviated versions). They were also asked to complete the same scales and questionnaires 8 days after discharge. The study involved 39 patients, the average interval between initial and follow-up assessment being 13.5 days. All the scores improved significantly, with the exception of quality of life and three out of the eight personality traits. This finding emphasizes the fact that improvement is not limited to depressive symptoms and enables us to identify the relative importance of each studied variable as a risk factor for attempted suicide. The limitations of the study are discussed as well as in particular the nongeneralizability of the sample and setting.