scholarly journals Experimental Investigation of the Effect of Using Porous Internal Sub-cooler on the Performance of Refrigeration System: R422A Case Study

2019 ◽  
Vol 37 (4) ◽  
pp. 1127-1132
Author(s):  
Mohammad Tarawneh
2011 ◽  
Vol 18 (3) ◽  
pp. 397-406 ◽  
Author(s):  
Michele Conti ◽  
Denis Van Loo ◽  
Ferdinando Auricchio ◽  
Matthieu De Beule ◽  
Gianluca De Santis ◽  
...  

2010 ◽  
Vol 16 (4) ◽  
pp. 112-121 ◽  
Author(s):  
Brennen W. Mills ◽  
Owen B. J. Carter ◽  
Robert J. Donovan

The objective of this case study was to experimentally manipulate the impact on arousal and recall of two characteristics frequently occurring in gruesome depictions of body parts in smoking cessation advertisements: the presence or absence of an external physical insult to the body part depicted; whether or not the image contains a clear figure/ground demarcation. Three hundred participants (46% male, 54% female; mean age 27.3 years, SD = 11.4) participated in a two-stage online study wherein they viewed and responded to a series of gruesome 4-s video images. Seventy-two video clips were created to provide a sample of images across the two conditions: physical insult versus no insult and clear figure/ground demarcation versus merged or no clear figure/ground demarcation. In stage one, participants viewed a randomly ordered series of 36 video clips and rated how “confronting” they considered each to be. Seven days later (stage two), to test recall of each video image, participants viewed all 72 clips and were asked to identify those they had seen previously. Images containing a physical insult were consistently rated more confronting and were remembered more accurately than images with no physical insult. Images with a clear figure/ground demarcation were rated as no more confronting but were consistently recalled with greater accuracy than those with unclear figure/ground demarcation. Makers of gruesome health warning television advertisements should incorporate some form of physical insult and use a clear figure/ground demarcation to maximize image recall and subsequent potential advertising effectiveness.


Energies ◽  
2019 ◽  
Vol 12 (6) ◽  
pp. 1079 ◽  
Author(s):  
Martin Belusko ◽  
Raymond Liddle ◽  
Alemu Alemu ◽  
Edward Halawa ◽  
Frank Bruno

Dew point cooling (DPC) is a novel indirect evaporative cooling concept capable of delivering air temperatures approaching the dew point. Coupling this technology with CO2 refrigeration is well suited to minimising transcritical operation when the coefficient of performance (COP) is dramatically reduced in hot climates. A substantial experimental program was conducted to characterise this combination by testing a 20 kW CO2 refrigeration system subject to ambient temperatures above 40 °C. It was demonstrated that DPC operation not only avoided transcritical operation during such weather conditions, but also increased the COP by up to 140% compared to the conventional system. The combination of these technologies was successfully mathematically modelled, from which the optimum condenser inlet air temperature was identified for each condenser temperature. Using this optimum condition, it was possible to maximise the COP for a range of conditions applicable to the psychometric chart. An annual case study for Adelaide, Australia was conducted which demonstrated that optimally coupling DPC with CO2 refrigeration can reduce the annual energy consumption and peak demand by 16% and 47%, respectively, compared to a conventional CO2 booster system. Furthermore, the number of hours of transcritical operation was reduced from 3278 to 27.


2010 ◽  
Vol 274 (3-4) ◽  
pp. 177-186 ◽  
Author(s):  
Andrea Orlando ◽  
Aida Maria Conte ◽  
Daniele Borrini ◽  
Cristina Perinelli ◽  
Giovanni Gianelli ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document