scholarly journals Low-Cost Brain-Computer Interface Using the Emotiv Epoc Headset Based on Rotating Vanes

2020 ◽  
Vol 37 (5) ◽  
pp. 831-837
Author(s):  
Mesut Melek ◽  
Negin Manshouri ◽  
Temel Kayikcioglu

Detailed In the brain-computer interface system (BCI), electroencephalography (EEG) signals are converted into digital signals and analyzed, allowing direct communication between humans and the electronic devices around them. The convenience of the user and the speed of communication with the surrounding devices are the most important challenges of BCI systems. The Emotiv Epoc headset minimizes the discomfort of the user thanks to its wet electrodes and easy handling. In the continuation of our previous works, in this paper, we developed our BCI system based on the gaze at the rotating vanes using the inexpensive Emotiv Epoc headset. In addition to user comfort, our design has an acceptable mean accuracy rate (ACC) and mean information transfer rate (ITR) compared to similar systems.

2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Shih Chung Chen ◽  
Aaron Raymond See ◽  
Yeou Jiunn Chen ◽  
Chia Hong Yeng ◽  
Chih Kuo Liang

People suffering from paralysis caused by serious neural disorder or spinal cord injury also need to be given a means of recreation other than general living aids. Although there have been a proliferation of brain computer interface (BCI) applications, developments for recreational activities are scarcely seen. The objective of this study is to develop a BCI-based remote control integrated with commercial devices such as the remote controlled Air Swimmer. The brain is visually stimulated using boxes flickering at preprogrammed frequencies to activate a brain response. After acquiring and processing these brain signals, the frequency of the resulting peak, which corresponds to the user’s selection, is determined by a decision model. Consequently, a command signal is sent from the computer to the wireless remote controller via a data acquisition (DAQ) module. A command selection training (CST) and simulated path test (SPT) were conducted by 12 subjects using the BCI control system and the experimental results showed a recognition accuracy rate of 89.51% and 92.31% for the CST and SPT, respectively. The fastest information transfer rate demonstrated a response of 105 bits/min and 41.79 bits/min for the CST and SPT, respectively. The BCI system was proven to be able to provide a fast and accurate response for a remote controller application.


2021 ◽  
Vol 2078 (1) ◽  
pp. 012044
Author(s):  
Lingzhi Chen ◽  
Wei Deng ◽  
Chunjin Ji

Abstract Pattern Recognition is the most important part of the brain computer interface (BCI) system. More and more profound learning methods were applied in BCI to increase the overall quality of pattern recognition accuracy, especially in the BCI based on Electroencephalogram (EEG) signal. Convolutional Neural Networks (CNN) holds great promises, which has been extensively employed for feature classification in BCI. This paper will review the application of the CNN method in BCI based on various EEG signals.


2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Setare Amiri ◽  
Reza Fazel-Rezai ◽  
Vahid Asadpour

Increasing number of research activities and different types of studies in brain-computer interface (BCI) systems show potential in this young research area. Research teams have studied features of different data acquisition techniques, brain activity patterns, feature extraction techniques, methods of classifications, and many other aspects of a BCI system. However, conventional BCIs have not become totally applicable, due to the lack of high accuracy, reliability, low information transfer rate, and user acceptability. A new approach to create a more reliable BCI that takes advantage of each system is to combine two or more BCI systems with different brain activity patterns or different input signal sources. This type of BCI, called hybrid BCI, may reduce disadvantages of each conventional BCI system. In addition, hybrid BCIs may create more applications and possibly increase the accuracy and the information transfer rate. However, the type of BCIs and their combinations should be considered carefully. In this paper, after introducing several types of BCIs and their combinations, we review and discuss hybrid BCIs, different possibilities to combine them, and their advantages and disadvantages.


A Brain-Computer Interface (BCI)is labeledas Mind-Machine Interface (MMI) or a Brain-Machine Interface (BMI). It affords a non-muscular channel of messagein between the computer and a human brain. Using the enhancements in interface equipment to electronics,and the necessity to helpindividuals suffering from disabilities, a new area in this study has begun by acceptingtasks of brain. The Electro-Encephalogram (EEG) is an electrical activity created by brain structures and verified from the scalp using electrodes. The EEG signal is used in actualspell to accomplishperipheral devices using a broad BCI system. The post-processed output signals are converted to suitable instructions to regulate output devices. The main seek is to aidparalyzed and physically immobilizedpersons to govern the home appliances making use of Electro-Encephalogram (EEG) signals, such that they grow to beautonomous. According to the brain responsiveness the devices can be designated then usingrelays, the switching of the home-basedmachinescan be completedconsequently.


Author(s):  
Selma Büyükgöze

Brain Computer Interface consists of hardware and software that convert brain signals into action. It changes the nerves, muscles, and movements they produce with electro-physiological signs. The BCI cannot read the brain and decipher the thought in general. The BCI can only identify and classify specific patterns of activity in ongoing brain signals associated with specific tasks or events. EEG is the most commonly used non-invasive BCI method as it can be obtained easily compared to other methods. In this study; It will be given how EEG signals are obtained from the scalp, with which waves these frequencies are named and in which brain states these waves occur. 10-20 electrode placement plan for EEG to be placed on the scalp will be shown.


2018 ◽  
Vol 28 (10) ◽  
pp. 1850034 ◽  
Author(s):  
Wei Li ◽  
Mengfan Li ◽  
Huihui Zhou ◽  
Genshe Chen ◽  
Jing Jin ◽  
...  

Increasing command generation rate of an event-related potential-based brain-robot system is challenging, because of limited information transfer rate of a brain-computer interface system. To improve the rate, we propose a dual stimuli approach that is flashing a robot image and is scanning another robot image simultaneously. Two kinds of event-related potentials, N200 and P300 potentials, evoked in this dual stimuli condition are decoded by a convolutional neural network. Compared with the traditional approaches, this proposed approach significantly improves the online information transfer rate from 23.0 or 17.8 to 39.1 bits/min at an accuracy of 91.7%. These results suggest that combining multiple types of stimuli to evoke distinguishable ERPs might be a promising direction to improve the command generation rate in the brain-computer interface.


Complexity ◽  
2020 ◽  
Vol 2020 ◽  
pp. 1-11
Author(s):  
Dalin Yang ◽  
Trung-Hau Nguyen ◽  
Wan-Young Chung

Brain-computer interface (BCI) technology represents a fast-growing field of research and applications for disabled and healthy people, which is a direct communication pathway to translate the neural information into an active command. Owing to the complicated headset structure, low accuracies, extended training periods, and nonstationary noises, BCI still has many challenges that should be dealt with for further facilitation of BCI technology use in daily life. In this study, a simplified synchronized hybrid BCI system is proposed for multiple command control by the electroencephalograph (EEG) signals in the motor cortex. This system can detect the single motor imagery (MI) task, single steady-state visually evoked potential (SSVEP) task, and hybrid MI + SSVEP tasks simultaneously (total ten mental tasks) via 2 EEG channels with high accuracy. The fast independent component analysis algorithm is employed to hybrid signals for obtaining clear EEG signals resulting from denoising. Feature extraction is performed by the wavelet transform, which is extracted by the features in the frequency and time domains. Furthermore, a four-layer convolutional neural network (CNN) is used as a classifier to distinguish different mental tasks. Finally, the hybrid MI + SSVEP system with a simple structure achieves a high accuracy of 95.56%. Additionally, the single MI-based and the SSVEP-based BCI system obtain the classification accuracy of 90.16% and 93.21%, respectively. Experimental results indicate that the synchronized hybrid BCI system could achieve multiple command control with a simple structure. In comparison with the single MI-based and the SSVEP-based BCI system, the hybrid MI + SSVEP BCI system shows a stable performance and higher efficiency. The proposed investigation provides a new method for the multiple command control by a hybrid BCI system. Also, the proposed BCI system offers the possibility of friendly utilization for disabled people because of its reliability, ease of use, and simplified headset structure.


Micromachines ◽  
2019 ◽  
Vol 10 (10) ◽  
pp. 681
Author(s):  
Bor-Shyh Lin ◽  
Bor-Shing Lin ◽  
Tzu-Hsiang Yen ◽  
Chien-Chin Hsu ◽  
Yao-Chin Wang

Brain–computer interface (BCI) is a system that allows people to communicate directly with external machines via recognizing brain activities without manual operation. However, for most current BCI systems, conventional electroencephalography (EEG) machines and computers are usually required to acquire EEG signal and translate them into control commands, respectively. The sizes of the above machines are usually large, and this increases the limitation for daily applications. Moreover, conventional EEG electrodes also require conductive gels to improve the EEG signal quality. This causes discomfort and inconvenience of use, while the conductive gels may also encounter the problem of drying out during prolonged measurements. In order to improve the above issues, a wearable headset with steady-state visually evoked potential (SSVEP)-based BCI is proposed in this study. Active dry electrodes were designed and implemented to acquire a good EEG signal quality without conductive gels from the hairy site. The SSVEP BCI algorithm was also implemented into the designed field-programmable gate array (FPGA)-based BCI module to translate SSVEP signals into control commands in real time. Moreover, a commercial tablet was used as the visual stimulus device to provide graphic control icons. The whole system was designed as a wearable device to improve convenience of use in daily life, and it could acquire and translate EEG signal directly in the front-end headset. Finally, the performance of the proposed system was validated, and the results showed that it had excellent performance (information transfer rate = 36.08 bits/min).


Author(s):  
Chang S. Nam ◽  
Matthew Moore ◽  
Inchul Choi ◽  
Yueqing Li

Despite the increase in research interest in the brain–computer interface (BCI), there remains a general lack of understanding of, and even inattention to, human factors/ergonomics (HF/E) issues in BCI research and development. The goal of this article is to raise awareness of the importance of HF/E involvement in the emerging field of BCI technology by providing HF/E researchers with a brief guide on how to design and implement a cost-effective, steady-state visually evoked potential (SSVEP)–based BCI system. We also discuss how SSVEP BCI systems can be improved to accommodate users with special needs.


2015 ◽  
Vol 12 (1) ◽  
pp. 49-62 ◽  
Author(s):  
Darius Birvinskas ◽  
Vacius Jusas ◽  
Ignas Martisius ◽  
Robertas Damasevicius

Electroencephalography (EEG) is widely used in clinical diagnosis, monitoring and Brain - Computer Interface systems. Usually EEG signals are recorded with several electrodes and transmitted through a communication channel for further processing. In order to decrease communication bandwidth and transmission time in portable or low cost devices, data compression is required. In this paper we consider the use of fast Discrete Cosine Transform (DCT) algorithms for lossy EEG data compression. Using this approach, the signal is partitioned into a set of 8 samples and each set is DCT-transformed. The least-significant transform coefficients are removed before transmission and are filled with zeros before an inverse transform. We conclude that this method can be used in real-time embedded systems, where low computational complexity and high speed is required.