scholarly journals Translation, Reliability Assessment, and Validation of the Persian Version of MedRisk Instrument for Measuring Patient Satisfaction With Physical Therapy Care (20-Item MRPS)

Author(s):  
Mahboobeh Abdolalizadeh ◽  
Maryam Ghodrati ◽  
Ahmad Saeedi ◽  
Hossein Kamyab ◽  
Ali Rezaie Rayeni Nejad

Introduction: This study aimed to evaluate the reliability and validity of the Persian version of the 20-item version of the MedRisk. Materials and Methods: In our study, we used a cross-sectional and prospective validation study design. This research was a test development study involving 297 outpatients with musculoskeletal disorders from the physiotherapy centers in Kerman City, Iran, in 2017. All patients completed the MedRisk instrument for measuring patient satisfaction with physical therapy care. Participants also answered a demographic questionnaire, visual analog score, and global rating of change. Internal consistency and reproducibility were investigated, too. To determine test-retest reliability, 40 randomly selected patients completed the MedRisk instrument again 5-7 days after their treatment. Factor analysis, divergent validity, convergent validity, and the floor and ceiling effects were tested, too. The Ethics Committee of the University of Social Welfare and Rehabilitation Sciences, Tehran, Iran, reviewed and approved this research project. The SPSS software-24 was used for statistical analysis. Results: Dimension of MedRisk demonstrated a high internal consistency (the Cronbach alpha=0.82). Reproducibility was also satisfactory (intraclass correlation coefficient=0.76). The standard error of measurement, minimal detectable changes, and coefficients of variation indices were respectively 0.63, 1.76, and 0.13 for the total score. In factor analysis, the 4-factor solution has emerged. The external validity testing revealed that the MedRisk instrument score correlated negatively with the visual analog scale (r=-0.18, P=0.002) and global rating of change (r=-0.19, P=0.001). Eighteen individual items of MedRisk were positively correlated with global satisfaction. The results showed that items 5 and 7 had a floor effect, and all other items except items 4, 5, and 7 had a ceiling effect. Conclusion: The Persian version of the MedRisk instrument is a valid and reliable instrument for measuring patient satisfaction with physical therapy and can be used in a clinical setting.

2021 ◽  
Vol 12 ◽  
Author(s):  
Ali Ebrahimi ◽  
Mojtaba Elhami Athar ◽  
Mitra Hakim Shooshtari ◽  
Hossain Karsazi ◽  
Eric A Storch

The current study was a cross-sectional research and aimed to investigate the factor structure, internal consistency, and validities of the Persian version of the Teasing Questionnaire-Revised (TQ-R). Forward and backward translations of the TQ-R were performed; face and content validities were determined based on comments by a sample of psychology students and specialists. Using the cluster sampling method, 290 participants were recruited, and 201 valid data (Mage = 23.53, SD = 3.53, 64.2% men) were analyzed. The factor structure was assessed by confirmatory and exploratory factor analysis (EFA). The result of the confirmatory factor analysis(es) did not confirm the proposed three, four, and five-factor models. EFA revealed four factors with 23 items, explaining 52.03% of the total variance. The internal consistency of the Persian version of Teasing Questionnaire 23 was in the excellent range (α = 0.92), and its expected associations with external correlates (e.g., depression and anxiety) supported the measure’s convergent validity. The findings indicated that the Persian version of the TQ-R has sound psychometric properties and can be used as a valid and reliable tool in research and clinical outcomes.


2021 ◽  
Vol In Press (In Press) ◽  
Author(s):  
Mahnaz Estaki ◽  
Ameneh Dehghan ◽  
Ebrahim Mahmoudi ◽  
Navid Mirzakhany

Background: Sensory integration is a necessary skill for acquiring reading skills because it strongly depends on the rapid and strong relation between written and verbal symbols. There is no standardized test for Iranian children with dyslexia to investigate their sensory processing problems. Therefore, understanding the validity and reliability of the child sensory profile 2 (CSP2) would be essential for a detailed assessment of sensory impairments in dyslexic children. Objectives: The current research aimed to establish the internal consistency, factor analysis, and convergent validity of the Persian version of CSP2 in children with dyslexia. Methods: The sample of this study included 200 dyslexic children aged 6 to 12 years who were referred to learning disabilities centers in Qom from September 2019 to February 2020 by using the multistage sampling method. To collect data, the CSP2 questionnaire and the dyslexia test (NEMA) were used. The factor structure was assessed by confirmatory factor analysis. The internal consistency of the CSP2 was examined by using Cronbach’s alpha. Convergent validity was assessed by examining the relationship between CSP2 and NEMA. Results: Internal consistency was obtained as 0.89, 0.92, 0.77, and 0.94 for the four subscales of sensory processing, namely registration, seeking, sensitivity, and avoiding, respectively. The result of confirmatory factor analysis gained support for Dunn's four-factor model. Total scores of NEMA were correlated with the scores of CSP2 subscales (seeking, avoiding, sensitivity, and registration). Conclusions: The Persian version of the Child Sensory Profile 2 is a valid (via confirmatory factor analysis and convergent validity) and reliable (via internal consistency) tool for assessing sensory processing in children with dyslexia.


2021 ◽  
Vol 15 (6) ◽  
pp. 2048-2053
Author(s):  
Mahya Torkaman ◽  
Marzieh Momennasab ◽  
Shahrzad Yektatalab ◽  
Mahin Eslamishahrbabaki

Background: Assessment of the patient safety competency is necessary for the growth of nursing and safe care profession as well as evaluation of the nurses' educational needs. To this end, valid and reliable tools are required. Aim:The present study was conducted to determine psychometric properties of the Persian version of the patient safety competency self-evaluation (PSCSE) tool in Iranian psychiatric wards. Methods: All nurses (n = 209) working in two psychiatric hospitals of Kerman, Iran were included in the present cross-sectional study using census method. Followed by administering the Persian version of PSCSE to the participants, its internal consistency and reliability were assessed by test-retest method with an interval of 14 days. Other psychometric properties such as content, construct, and convergent validity of the tool were also examined. Results:The content validity index was 0.65 and the content validity ratio was 0.89. Item 14 was removed from the skill domain because it was not related to the psychiatric ward. According to the results of factor analysis, 40 items and three domains of knowledge (6 items), attitude (14 items), and skills (20 items) were confirmed with acceptable values. In terms of its convergent validity, PSCSE had a moderate correlation (r = 0.57) with the Assessment of the Safe Nursing Care (ASNC) scale. The correlation coefficient for test-retest was ICC = 0.92 for the whole instrument and 0.89, 0.89, and 0.92 for the domains of knowledge, attitude, and skill, respectively. The internal consistency coefficient (Cronbach's alpha) of the whole tool was 0.95 and 0.95, 0.79, and 0. 95 for the domains of knowledge, attitude, and skill, respectievly. Conclusion: Persian version of the nurses' competency tool in ensuring patient safety in psychiatric wards has acceptable psychometric characteristics. Keywords: Validity, Reliability, Confirmatory factor analysis, Patient safety competency, psychiatric nurse


BMJ Open ◽  
2018 ◽  
Vol 8 (8) ◽  
pp. e021900 ◽  
Author(s):  
Chatree Chai-Adisaksopha ◽  
Mark W Skinner ◽  
Randall Curtis ◽  
Neil Frick ◽  
Michael B Nichol ◽  
...  

ObjectiveTo assess the psychometric properties of the Patient Reported Outcomes, Burdens and Experiences (PROBE) questionnaire.MethodsThis study was a cross-sectional, multinational study. Participants were enrolled if they were more than 10 years old and people with haemophilia A or B or people without a bleeding disorder. Participants were invited through non-governmental patient organisations in 21 countries between 01/27/2016 and 02/23/2017. The following psychometric properties: missing data, floor and ceiling effects, exploratory factor analysis and internal consistency reliability were examined. A PROBE Score was derived and assessed for its convergent and known groups validity.ResultsThe study analysed the data on 916 participants with median age of 37.0 (IQR 27.0 to 48.0) years, 74.8% male. In the domain assessing patient-reported outcomes (PROs), more than 15% of participants presented a ceiling effect for all items but two, and a floor effect for one item. Factor analysis identified three factors explaining the majority of the variance. Cronbach’s alpha coefficient indicated good internal consistency reliability (0.84). PROBE items showed moderate to strong correlations with corresponding EuroQol five dimension 5-level instrument (EQ-5D-5L) domains. The PROBE Score has a strong correlation (r=0.67) with EQ-5D-5L utility index score. The PROBE Score has a known groups validity among various groups.ConclusionsThe results of this study suggest that PROBE is a valid questionnaire for evaluating PROs in people with haemophilia as well as control population. The known-group property of PROBE will allow its use in future clinical trials, longitudinal studies, health technology assessment studies, routine clinical care or registries. Additional studies are needed to test responsiveness and sensitivity to change.Trial registration numberNCT02439710; Results.


Author(s):  
Hayam Mohammed Elgohari ◽  
Medhat Mohamed Bassiony ◽  
Mohammad Gamal Sehlo ◽  
Usama Mahmoud Youssef ◽  
Heba Mohamed Ali ◽  
...  

Abstract Background Stigma has been noticed towards patients with COVID-19 in several regions of the world. This social discrimination has contributed to delay in diagnosis and treatment. Also, it may increase the suffering of the patients leading to poor outcome of the illness. Stigma can be assessed with the use of a valid and reliable instrument developed and adapted to our culture. Our objective was to analyze the psychometric properties of COVID-19 Infection Stigma Scale (CISS) for measuring the social stigma among patients with COVID-19 in Egypt. A cross-sectional study that included 182 COVID-19 patients was carried out. The reliability, the convergent validity, and the external and internal consistency of the scale were measured. Factor analysis was used to exclude the weak items. Results The mean of the COVID-19 Infection Stigma Scale scores was 34.97±10.35 which was higher than 50% of the score. Absence of the floor and ceiling effects was observed. Cronbach’s alpha coefficient for scale reliability ranged from 0.75 to 0.94 with 0.82 for the total score. The convergent validity coefficients ranged from 0.36 to 0.63. Test-retest validity Pearson’s correlation coefficients ranged from 0.72 to 0.92 with 0.89 for the total score. The split half correlation coefficient was 0.86, and the reliability coefficient was 0.92. Both were acceptable correlation coefficients for internal consistency of the scale. Factor analysis showed two factors had latent root greater than 1. The rotated component matrix of the 2 factors revealed that all questions had r value more than 0.30, which means that no need to exclude any of them. Conclusion The results showed that the COVID-19 Infection Stigma Scale is a valid and reliable instrument for the Egyptian people.


Author(s):  
Negar Nikbakht ◽  
◽  
Mehdi Rezaee ◽  
Seyed Mehdi Tabatabaee ◽  
Gholam-Ali Shahidi ◽  
...  

Introduction: There is a need to have appropriate information about the ability of Parkinson's disease (PD) patients to perform cognitive instrumental activities of daily living (IADL). The purpose of the present study was to assess the psychometric properties of the Persian version of the Penn Parkinson's Daily Activities Questionnaire-15 (PDAQ-15). Methods: A total of 165 knowledgeable informants of PD patients completed the PDAQ-15. The Clinical Dementia Rating Scale, Hoehn and Yahr staging, Hospital Anxiety and Depression Scale (HADS) and Lawton IADL scale were included in the study. Internal consistency and test-retest reliability were evaluated by Cronbach's alpha coefficient and intraclass correlation coefficient (ICC), respectively. To examine the dimensionality of the questionnaire, exploratory factor analysis was used. The construct validity was assessed using Spearman rank correlation test. To assess the discriminative validity, PDAQ-15 scores were compared across cognitive stages. Results: The PDAQ-15 showed strong internal consistency (Cronbach's α = 0.99) and test-retest reliability (ICC= 0.99). Only one dimension identified for the PDAQ-15 in the factor analysis. There was strong correlation between PDAQ-15 with depression domain of HADS scale and Lawton IADL scale. (rs = |0.71–0.95|). The correlation of PDAQ-15 with anxiety domain of HADS scale was moderate (rs = 0.66). Discriminative validity analysis showed that the PDAQ-15 has significant power to discriminate between PD patients across cognitive stages. Conclusion: These results suggest that the PDAQ-15 is a valid and reliable PD-specific instrument that can be useful in clinical and research settings.


2021 ◽  
Vol 9 ◽  
Author(s):  
Hamid Sharif Nia ◽  
Pardis Rahmatpour ◽  
Erika Sivarajan Froelicher ◽  
Saeed Pahlevan Sharif ◽  
Omolhoda Kaveh ◽  
...  

Background: Several studies indicate a high prevalence of depression around the world during the period of the COVID-19 pandemic. Using a valid instrument to capture the depression of an individual in this situation is both important and timely. The present study aims to evaluate the psychometric properties of the Persian version of the Center for Epidemiological Studies Depression Scale (CES-D) among the public during the COVID-19 pandemic in Iran.Method: This is a cross-sectional study that was conducted in the Iranian population (n = 600) from April to July 2020. A two-part online form was used: sociodemographic characteristics and depression items (CES-D). The construct validity and internal consistency reliability of the scale were evaluated.Result: The results of the exploratory factor analysis illustrated two factors with 43.35% of the total variance of the depression were explained. Confirmatory factor analysis indicated that this model fits well. Internal consistency reliability was evaluated, and it was acceptable.Conclusion: The findings demonstrated that, in the Iranian sample, this depression scale yielded two factors (somatic and positive affects) solutions with suitable psychometric properties.


2019 ◽  
Author(s):  
Daniel Rodríguez-Almagro ◽  
Alexander Achalandabaso ◽  
Alma Rus ◽  
Esteban Obrero-Gaitán ◽  
Noelia Zagalaz-Anula ◽  
...  

Abstract Background. The Migraine Disability Assessment (MIDAS) questionnaire is widely used for determining headache-related disability. However, to the best of our knowledge, there is no validated Spanish version of the questionnaire. It is composed of seven items; the first five items constitute the main scale, while the sixth and seventh items refer respectively to the frequency and intensity of headache. The present study is aimed at analyzing the clinimetric properties of the Spanish version of the MIDAS questionnaire in a population of university students.Methods. We performed a cross-sectional study of validation of measuring instruments. One hundred fifty-three subjects participated in the study. We analyzed construct validity by factor analysis, test-retest reliability by the Intraclass Correlation Coeficient (ICC), internal consistency, and concurrent validity with respect to the 12-Item Short Form Health Survey (SF-12).Results. Factor analysis showed a two factors structure composed. The questionnaire presented good reliability for the MIDAS-main scale score ([ICC = 0.81; 95% CI: 0.63 – 0.90]), excellent reliability for headache frequency (ICC = 0.90; 95%; CI: [0.79 – 0.95]), and moderate reliability for headache intensity (ICC = 0.63; 95% CI: [0.34 – 0.80]). The analysis also showed good internal consistency results (α Cronbach = 0.797) and a moderate correlation between MIDAS-main scale and physical summary component of SF-12 (Rho = -0.326; p < 0.001).Conclusions. The Spanish version of the MIDAS questionnaire is a valid and reliable tool to measure headache-related disability in university subjects. The two additional items provide information that could help clinicians in making decisions.


2020 ◽  
Author(s):  
Karolina Vlckova ◽  
Eva Hoschlova ◽  
Eva Chroustova ◽  
Martin Loucka

Abstract Background Outcome measurement is an essential part of the evaluation of palliative care and the measurements need to be reliable, valid and adapted to the culture in which they are used. The Integrated Palliative Outcome Scale (IPOS) is a widely used tool for assessing outcomes in palliative care. The aim of this study was to provide Czech version of IPOS and asses its psychometric properties.Methods Patients receiving palliative care in hospice or hospitals completed IPOS and part of the sample also completed Edmonton Symptom Assessment System (ESAS) and Palliative Performance Scale (PPS). The reliability of Czech IPOS was tested with Cronbach alpha (internal consistency) and Intraclass correlation coefficient and Weighted Kappa (test-retest reliability). Construct validity was assessed with factor analysis (Exploratory Factor Analysis) and convergent validity was tested with correlation analysis (Spearman correlation).Results Sample consisted of 140 patients (mean age 72; 90 women; 81% oncologic disease). IPOS internal consistency was 0.789; ICC= 0.88. To study convergent validity, we assessed the correlations of IPOS with ESAS (R= 0.4) and PPS (R= -0.2), however, these results have to be considered preliminary due to the small sample size. Exploratory factor analysis revealed a 2-factor solution on our data. The first factor covers emotional and information needs and the second factor covers physical symptoms.Conclusion Czech IPOS has very good reliability regarding both internal consistency and test-retest reliability. Together with an item analysis results, we can conclude that the Czech adaptation of the tool was successful. The convergent validity needs to be assessed on the larger sample and the proposed 2-factor internal structure of the questionnaire has to be confirmed by using CFA.


2021 ◽  
Vol 0 ◽  
pp. 1-8
Author(s):  
Maria Nikoloudi ◽  
Eleni Tsilika ◽  
Efi Parpa ◽  
Sotiria Kostopoulou ◽  
Anastasios Tentolouris ◽  
...  

Objectives: This study aims to develop the Greek version of the Herth Hope Index (HHI) and assess its psychometric properties to a palliative care patient sample, using a cross-sectional design. Materials and Methods: The HHI was translated into Greek (HHI-Gr) using the ‘forward-backward’ procedure. It was administered to 130 eligible cancer patients, while for the stability of patients’ responses, 40 of these patients completed the HHI-Gr 3 days later. Along with the HHI-Gr, patients also completed the Hospital Anxiety and Depression Scale (HADS) and the Beck Hopelessness Scale (BHS). The HHI-Gr internal consistency reliability (Cronbach’s a), stability (intraclass correlation coefficient [ICC]), factor structure (factor analysis) and convergent validity (correlation with the HADS and the BHS questionnaires) were examined using the Eastern Cooperative Oncology Group (ECOG) performance status. Results: The HHI-Gr yielded a one-factor model and a Cronbach alpha (0.860) with excellent internal consistency reliability and stability ICC (>0.90). Satisfactory convergent validity was supported by the correlation analysis between the HHI-Gr and BHS (r = 0.718, P < 0.001). Overall test-retest reliability was satisfactory with a range between 0.77 and 0.96 (P < 0.001). Conclusion: These results demonstrate that the HHI-Gr is an instrument with satisfactory psychometric properties and is a valid research tool for the measurement of the levels of hope among Greek oncology patients.


Sign in / Sign up

Export Citation Format

Share Document