Prevalence and classification of asymmetric forms of sensorineural hearing loss in older age group

2021 ◽  
Vol 20 (5) ◽  
pp. 8-12
Author(s):  
T. Yu. Vladimirova ◽  
◽  
A. B. Martynova ◽  

The significance of asymmetric sensorineural hearing loss (ASNHL) is due to a special approach to diagnosis, followed by the process of hearing aids and auditory rehabilitation. Currently, there is no standard audiometric criterion for determining the forms of asymmetry, which significantly affects the assessment of the prevalence of ASNHL. The study aimed to assess the prevalence and classification of ASNHL forms in the older age group using two methods of calculation: 1) the difference in the average hearing threshold at speech frequencies (in the range of 0,5–4 kHz) ≥15 dB was detected in 14,14% of cases; 2) the different degree of hearing loss, according to the International classification, in the right and left ear was 35,98%. In most cases, asymmetry was manifested by bilateral sensorineural hearing loss of varying severity, prevailing in the group of long-livers – 82,6%. Given the potentially high prevalence of asymmetry depending on the audiological criterion, the results of the work are a reason for further research in the development of a unified method for verifying a clinically significant form of ASNHL.

Author(s):  
Masoud Motasaddi Zarandy ◽  
Hakima Abdullah ◽  
Mina Motasaddi Zarandy ◽  
Mohammadreza Firouzifar ◽  
Farzad Moubedshahi

Background: Osteopetrosis (OP) is a rare disease of the skeletal system that can be associated with complications such as bone fracture, nerve dysfunction and deafness due to increased bone density and reduced bone quality. In this regard and due to the challenge that it can cause for cochlear implantation (CI), in this study we aimed to report CI conducted on two patients with OP in Iran. The Case: Patients were two women diagnosed with OP and bilateral sensorineural hearing loss (SNHL) who underwent CI in the right ear. Preoperative PTA showed a hearing threshold decrease of more than 100 dB in both patients. A standard cochleostomy was performed in one patient and endoscopic surgery in the other patient through the external ear canal. One month after surgery, the hearing threshold improved b y 60−90 dB in both patients. No facial nerve palsy or implant extrusion/migration was observed after surgery. Conclusion: Although technically challenging, CI seems to be a safe and effective method to improve the SNHL in patients with OP. The path for electrode insertion should be tailored to meet the conditions and anatomy of patients. Keywords: Cochlear implantation; osteopetrosis; sensorineural hearing loss


2021 ◽  
Vol 37 (1) ◽  
Author(s):  
Diala Hussein ◽  
Büşra Altın ◽  
Münir Demir Bajin

Abstract Background H syndrome is an autosomal recessive disorder caused by mutations in SLC29A3. Hyperpigmentation, hypertrichosis, hyperglycemia, and hearing loss are some characteristics of this disorder, and it has a prevalence of < 1/1000. The aim of this report is to spread awareness among otologists, audiologists, and pediatricians about this syndrome and its audiological features. Case presentation An 8-year-old male with a diagnosed H syndrome registered to our clinic with a complaint of hearing loss. The patient was diagnosed with hearing loss in a different clinic using only the air-conducted click auditory brainstem response test which showed wave V at 60 dB nHL for the right ear and at 80 dB nHL for the left ear. The initially performed pure tone audiometry (PTA) test in our clinic revealed a bilateral asymmetric hearing loss with a moderate sensorineural hearing loss in the right ear and a profound mixed hearing loss in the left ear. The performed air conducted click auditory brainstem response (ABR) result showed wave V at 55 dB nHL for the right ear and at 70 dB nHL for the left ear. Then, the repeated PTA test revealed a mild-severe sensorineural sloping hearing loss in the right ear and a severe sensorineural hearing loss in the left ear. Conclusion Although hearing thresholds in H syndrome could be within normal limits in some patients, sensorineural hearing loss is an important characteristic feature for this syndrome. Sensorineural hearing loss could be progressive or of sudden onset and ranges from mild to profound. Thus, it must be taken into consideration to apply the audiological follow-up regularly and paying attention to the patient’s complaints; also, a regular follow-up for language development of children with H syndrome and for the hearing aids is advised.


1979 ◽  
Vol 88 (1) ◽  
pp. 86-91 ◽  
Author(s):  
H. Patricia Heffernan ◽  
Marsha R. Simons

Two cases are presented exhibiting temporary increases in sensorineural hearing loss following hearing aid use. Data suggesting this correlation are shown. There were no contributing middle ear problems during the period surveyed. The most significant changes in hearing thresholds were at frequencies 1000 and 2000 Hz. The use of different hearing aids, with decreased maximum power outputs, was not found to have similar effects on hearing threshold levels. A scheduling regime is recommended for introducing any new hearing aid to a child.


2015 ◽  
Vol 26 (01) ◽  
pp. 068-079 ◽  
Author(s):  
Jürgen Kiessling ◽  
Melanie Leifholz ◽  
Steffen Unkel ◽  
Jörn Pons-Kühnemann ◽  
Charlotte Thunberg Jespersen ◽  
...  

Background: In-situ audiometry is a hearing aid feature that enables the measurement of hearing threshold levels through the hearing instrument using the built-in sound generator and the hearing aid receiver. This feature can be used in hearing aid fittings instead of conventional pure-tone audiometry (PTA), particularly in places where no standard audiometric equipment is available. Differences between conventional and in-situ thresholds are described and discussed for some particular hearing aids. No previous investigation has measured and compared these differences for a number of current hearing aid models by various manufacturers across a wide range of hearing losses. Purpose: The purpose of this study was to perform a model-based comparison of conventionally and in-situ measured hearing thresholds. Data were collected for a range of hearing aid devices to study and generalize the effects that may occur under clinical conditions. Research Design: Research design was an experimental and regression study. Study Sample: A total of 30 adults with sensorineural hearing loss served as test persons. They were assigned to three subgroups of 10 subjects with mild (M), moderate to severe (MS), and severe (S) sensorineural hearing loss. Intervention: All 30 test persons underwent both conventional PTA and in-situ audiometry with four hearing aid models by various manufacturers. Data Collection and Analysis: The differences between conventionally and in-situ measured hearing threshold levels were calculated and evaluated by an exploratory data analysis followed by a sophisticated statistical modeling process. Results: At 500 and 1500 Hz, almost all threshold differences (conventional PTA minus in-situ data) were negative, i.e., in the low to mid frequencies, hearing loss was overestimated by most devices relative to PTA. At 4000 Hz, the majority of differences (7 of 12) were positive, i.e., in the frequency range above 1500 Hz, hearing loss was frequently underestimated. As hearing loss increased (M→MS→S), the effect of the underestimation decreased. At 500 and 1500 Hz, Resound devices showed the smallest threshold deviations, followed by Phonak, Starkey, and Oticon instruments. At 4000 Hz, this observed pattern partly disappeared and Starkey and Oticon devices showed a reversed effect with increasing hearing loss (M→MS→S). Because of high standard errors for the estimates, only a few explicit rankings of the devices could be established based on significant threshold differences (5% level). Conclusions: Differences between conventional PTA and in-situ threshold levels may be attributed to (1) frequency, (2) device/hearing loss, and (3) calibration/manufacturer effects. Frequency effects primarily resulting in an overestimation of hearing loss by in-situ audiometry in the low and mid frequencies are mainly due to sound drain-off through vents and leaks. Device/hearing loss effects may be due to leakage as well as boundary effects because in-situ audiometry is confined to a limited measurement range. Finally, different calibration approaches may result in different offset levels between PTA and in-situ audiometry calibration. In some cases, the observed threshold differences of up to 10–15 dB may translate to varied hearing aid fittings for the same user depending on how hearing threshold levels were measured.


2020 ◽  
Vol 19 (5) ◽  
pp. 36-43
Author(s):  
T. Yu. Vladimirova ◽  
◽  
A. B. Martynova ◽  

A study was conducted of 300 patients with chronic sensorineural hearing loss (SNHL) in four age groups, allocated according to the age classification of the World Health Organization (WHO). For patients of the older age group, a high comorbidity index is noted, while among concomitant diseases, chronic non-infectious diseases that are likely to affect hearing (arterial hypertension, cardiovascular disease (CVDs), diabetes mellitus) are more often observed with age. A direct correlation was found between diseases that probably affect the auditory function and quality of life (QoL) of patients. It was noted that the proportion of people with moderate and severe hearing impairment increases with age, while the total QoL indicator correlated with age (inverse correlation in the elderly, direct correlation in senile people and long-livers) and the degree of SNHL (inverse correlation). Self-assessment of QOL level by the physical component in patients of the older age group corresponded to the pre-critical level.


2008 ◽  
Vol 139 (2_suppl) ◽  
pp. P57-P57
Author(s):  
Drew M Horlbeck ◽  
Herman A Jenkins ◽  
Ben J Balough ◽  
Michael E Hoffer

Objective The efficacy of the Otologics Fully Implantable Hearing Device (MET) was assessed in adult patients with bilateral moderate to severe sensorineural hearing loss. Methods Surgical insertion of this totally implanted system was identical to the Phase I study. A repeated-measures within-subjects design assessed aided sound field thresholds and speech performances with the subject's own, appropriately fit, walk-in hearing aid(s) and the Otologics Fully Implantable Hearing Device. Results Six- and 12-month Phase II data will be presented. Ten patients were implanted and activated as part Phase II clinical trial. Three patients were lost to long term follow-up due to two coil failures and one ossicular abnormality preventing proper device placement. No significant differences between preoperative (AC = 59 dB, BC = 55 dB) and postoperative (AC = 61 dB, BC = 54 dB) unaided pure tone averages were noted (p < 0.05). Pure tone average implant aided thresholds (41 dB) were equivalent to that of walk-in-aided (37 dB) condition with no significant difference (p < 0.05) between patients’ walk-in-aided individual frequency thresholds and implant-aided thresholds. Word recognition scores and hearing in noise scores were similar between the walk-in-aided and for the implant-aided condition. Patient benefit scales will be presented at all end points. Conclusions Results of the Otologics MET Fully Implantable Hearing Device Phase II trial provide evidence that this fully implantable device is a viable alternative to currently available hearing aids in patients with sensorineural hearing loss.


2018 ◽  
Vol 23 (5) ◽  
pp. 277-284 ◽  
Author(s):  
Chia-Huei Chu ◽  
Shiau-Ru Chiou ◽  
Mao-Che Wang ◽  
An-Suey Shiao ◽  
Tzong-Yang Tu ◽  
...  

Objective: The purpose of this retrospective study was to investigate the difference in treatment outcomes for patients with idiopathic sudden sensorineural hearing loss (SSNHL) undergoing concurrent or sequential intravenous (IV) and intratympanic (IT) steroid therapies. Methods: Patients with idiopathic SSNHL admitted to Taipei Veterans Hospital from August 2011 to August 2012 were enrolled. Patients were treated with both IV dexamethasone 5 mg b.i.d. for 5 days, then tapered over 6 days, and IT injections of dexamethasone 5 mg daily. The administration of IV and IT steroids was given either concurrently or sequentially (IV steroid was administered from days 1–5 followed by IT steroid treatment starting on day 4 or day 5). The hearing outcomes of the concurrent and sequential groups were analyzed. Results: Overall, after ≥2 months following treatment, across frequencies ranging from 250 to 8,000 Hz and pure-tone average (PTA) assessments, hearing improvements were similar between treatment groups, except at the frequencies of 4,000 and 8,000 Hz where the concurrent treatment group had greater hearing gain than the sequential group (4,000 Hz: 30.68 ± 28.96 vs. 14.52 ± 24.06 dB, respectively, p = 0.042; 8,000 Hz: 22.62 ± 23.59 vs. 7.67 ± 21 dB, p = 0.030). Across frequencies and PTA assessments, a similar percentage of patients had ≥20-dB gains in hearing compared with patients treated sequentially, except at 8,000 Hz where a greater percentage of patients in the concurrent group (57.1%) than the sequential group (23.3%) (p = 0.014) had ≥20-dB hearing gains. Conclusion: The findings suggest that both concurrent and sequential treatment improve hearing in patients with idiopathic SSNHL, and that concurrent treatment may show greater benefit than sequential therapy, particularly at high frequencies.


2008 ◽  
Vol 136 (5-6) ◽  
pp. 221-225
Author(s):  
Slobodan Spremo ◽  
Zdenko Stupar

INTRODUCTION Cochlear damage secondary to exposure to acoustic trauma is the consequence of the acoustic energy effects on the hearing cells in Korti's organ. OBJECTIVE The objective was to assess the correlation between the degree of sensorineural hearing loss and the type of audiogram registered in acoustic trauma exposed patients. METHOD We analyzed 262 audiograms of patients exposed to acoustic trauma in correlation to 146 audiograms of patients with cochlear damage and hearing loss not related to acoustic trauma. "A" group consisted of acoustic trauma cases, while "B" group incorporated cases with hearing loss secondary to cochlear ischaemia or degeneration. All audiograms were subdivided with regard to the mean hearing loss into three groups: mild (21-40 dB HL), moderate (41-60 dB HL) and severe (over 60 dB HL) hearing loss. Based on audiogram configuration five types of audiogram were defined: type 1 flat; type 2 hearing threshold slope at 2 kHz, type 3 hearing threshold slope at 4 kHz; type 4 hearing threshold notch at 2 kHz; type 5 notch at 4 kHz. RESULTS Mild hearing loss was recorded in 163 (62.2%) ears in the acoustic trauma group, while in 78 (29.8%) ears we established moderate hearing loss with the maximum threshold shift at frequencies ranging from 4 kHz to 8 kHz. The least frequent was profound hearing loss, obtained in 21 (8%) audiograms in the acoustic trauma group. Characteristic audiogram configurations in the acoustic trauma patient group were: type 1 (N=66; 25.2%), type 2 (N=71; 27.1%), and type 3 (N=68; 25.9%). Audiogram configurations were significanly different in the acoustic trauma group in comparison to the cochlear ischaemia group of patients (p=0.0005). CONCLUSION Cochlear damage concomitant to acoustic trauma could be assessed by the audiogram configuration. Preserved hearing acuity at low and mild frequency range indicates the limited damage to the hearing cells in Korti's organ in the apical cochlear turn.


2017 ◽  
Author(s):  
Joanna Nkyekyer ◽  
Denny Meyer ◽  
Peter J Blamey ◽  
Andrew Pipingas ◽  
Sunil Bhar

BACKGROUND Sensorineural hearing loss is the most common sensory deficit among older adults. Some of the psychosocial consequences of this condition include difficulty in understanding speech, depression, and social isolation. Studies have shown that older adults with hearing loss show some age-related cognitive decline. Hearing aids have been proven as successful interventions to alleviate sensorineural hearing loss. In addition to hearing aid use, the positive effects of auditory training—formal listening activities designed to optimize speech perception—are now being documented among adults with hearing loss who use hearing aids, especially new hearing aid users. Auditory training has also been shown to produce prolonged cognitive performance improvements. However, there is still little evidence to support the benefits of simultaneous hearing aid use and individualized face-to-face auditory training on cognitive performance in adults with hearing loss. OBJECTIVE This study will investigate whether using hearing aids for the first time will improve the impact of individualized face-to-face auditory training on cognition, depression, and social interaction for adults with sensorineural hearing loss. The rationale for this study is based on the hypothesis that, in adults with sensorineural hearing loss, using hearing aids for the first time in combination with individualized face-to-face auditory training will be more effective for improving cognition, depressive symptoms, and social interaction rather than auditory training on its own. METHODS This is a crossover trial targeting 40 men and women between 50 and 90 years of age with either mild or moderate symmetric sensorineural hearing loss. Consented, willing participants will be recruited from either an independent living accommodation or via a community database to undergo a 6-month intensive face-to-face auditory training program (active control). Participants will be assigned in random order to receive hearing aid (intervention) for either the first 3 or last 3 months of the 6-month auditory training program. Each participant will be tested at baseline, 3, and 6 months using a neuropsychological battery of computer-based cognitive assessments, together with a depression symptom instrument and a social interaction measure. The primary outcome will be cognitive performance with regard to spatial working memory. Secondary outcome measures include other cognition performance measures, depressive symptoms, social interaction, and hearing satisfaction. RESULTS Data analysis is currently under way and the first results are expected to be submitted for publication in June 2018. CONCLUSIONS Results from the study will inform strategies for aural rehabilitation, hearing aid delivery, and future hearing loss intervention trials. CLINICALTRIAL ClinicalTrials.gov NCT03112850; https://clinicaltrials.gov/ct2/show/NCT03112850 (Archived by WebCite at http://www.webcitation.org/6xz12fD0B).


Author(s):  
Raphella Khan ◽  
Anirudh Kasliwal

<p class="abstract"><strong>Background:</strong> Chronic squamosal otitis media can occur due to many conditions affecting the middle ear. Most common sign of developing a chronic squamosal otitis media is formation of a retraction pocket in the tympanic membrane leading to further development of a cholesteatoma and if not treated properly, may lead to development of dangerous complication in the affected ear. These etiological factors may also affect the other ear. It is therefore very necessary to assess and diagnose the contralateral ear, so that the disease can be intervened and treated at the right time, to prevent any deterioration in hearing of the contralateral ear.</p><p class="abstract"><strong>Methods:</strong> The prospective study was done in 100 patients with unilateral chronic squamosal otitis media, where the contra lateral ear was examined and assessed for any hearing loss.  </p><p class="abstract"><strong>Results:</strong> We found hearing loss in the contra lateral ear ranging from mild conductive hearing loss to sensorineural hearing loss with the maximum patients with mild conductive hearing loss (42%) and lowest in sensorineural hearing loss (1%).  </p><p class="abstract"><strong>Conclusions:</strong> In our study, 76 patients were seen with conductive hearing loss. Out of that, 42% patients were seen with mild conductive hearing loss, 30% with moderate conductive hearing loss and 4% with severe conductive hearing loss. 20% patients were seen with normal hearing. 3% patients were seen with mixed hearing loss and only 1% patient was seen with sensorineural hearing loss in contralateral ear.</p>


Sign in / Sign up

Export Citation Format

Share Document