Temporary Increase in Sensorineural Hearing Loss with Hearing Aid Use

1979 ◽  
Vol 88 (1) ◽  
pp. 86-91 ◽  
Author(s):  
H. Patricia Heffernan ◽  
Marsha R. Simons

Two cases are presented exhibiting temporary increases in sensorineural hearing loss following hearing aid use. Data suggesting this correlation are shown. There were no contributing middle ear problems during the period surveyed. The most significant changes in hearing thresholds were at frequencies 1000 and 2000 Hz. The use of different hearing aids, with decreased maximum power outputs, was not found to have similar effects on hearing threshold levels. A scheduling regime is recommended for introducing any new hearing aid to a child.

2017 ◽  
Author(s):  
Joanna Nkyekyer ◽  
Denny Meyer ◽  
Peter J Blamey ◽  
Andrew Pipingas ◽  
Sunil Bhar

BACKGROUND Sensorineural hearing loss is the most common sensory deficit among older adults. Some of the psychosocial consequences of this condition include difficulty in understanding speech, depression, and social isolation. Studies have shown that older adults with hearing loss show some age-related cognitive decline. Hearing aids have been proven as successful interventions to alleviate sensorineural hearing loss. In addition to hearing aid use, the positive effects of auditory training—formal listening activities designed to optimize speech perception—are now being documented among adults with hearing loss who use hearing aids, especially new hearing aid users. Auditory training has also been shown to produce prolonged cognitive performance improvements. However, there is still little evidence to support the benefits of simultaneous hearing aid use and individualized face-to-face auditory training on cognitive performance in adults with hearing loss. OBJECTIVE This study will investigate whether using hearing aids for the first time will improve the impact of individualized face-to-face auditory training on cognition, depression, and social interaction for adults with sensorineural hearing loss. The rationale for this study is based on the hypothesis that, in adults with sensorineural hearing loss, using hearing aids for the first time in combination with individualized face-to-face auditory training will be more effective for improving cognition, depressive symptoms, and social interaction rather than auditory training on its own. METHODS This is a crossover trial targeting 40 men and women between 50 and 90 years of age with either mild or moderate symmetric sensorineural hearing loss. Consented, willing participants will be recruited from either an independent living accommodation or via a community database to undergo a 6-month intensive face-to-face auditory training program (active control). Participants will be assigned in random order to receive hearing aid (intervention) for either the first 3 or last 3 months of the 6-month auditory training program. Each participant will be tested at baseline, 3, and 6 months using a neuropsychological battery of computer-based cognitive assessments, together with a depression symptom instrument and a social interaction measure. The primary outcome will be cognitive performance with regard to spatial working memory. Secondary outcome measures include other cognition performance measures, depressive symptoms, social interaction, and hearing satisfaction. RESULTS Data analysis is currently under way and the first results are expected to be submitted for publication in June 2018. CONCLUSIONS Results from the study will inform strategies for aural rehabilitation, hearing aid delivery, and future hearing loss intervention trials. CLINICALTRIAL ClinicalTrials.gov NCT03112850; https://clinicaltrials.gov/ct2/show/NCT03112850 (Archived by WebCite at http://www.webcitation.org/6xz12fD0B).


2018 ◽  
Author(s):  
Matthew E Hughes ◽  
Joanna Nkyekyer ◽  
Hamish Innes-Brown ◽  
Susan L Rossell ◽  
David Sly ◽  
...  

BACKGROUND Older adults with postlingual sensorineural hearing loss (SNHL) exhibit a poor prognosis that not only includes impaired auditory function but also rapid cognitive decline, especially speech-related cognition, in addition to psychosocial dysfunction and an increased risk of dementia. Consistent with this prognosis, individuals with SNHL exhibit global atrophic brain alteration as well as altered neural function and regional brain organization within the cortical substrates that underlie auditory and speech processing. Recent evidence suggests that the use of hearing aids might ameliorate this prognosis. OBJECTIVE The objective was to study the effects of a hearing aid use intervention on neurocognitive and psychosocial functioning in individuals with SNHL aged ≥55 years. METHODS All aspects of this study will be conducted at Swinburne University of Technology (Hawthorn, Victoria, Australia). We will recruit 2 groups (n=30 per group) of individuals with mild to moderate SNHL from both the community and audiology health clinics (Alison Hennessy Audiology, Chelsea Hearing Pty Ltd). These groups will include individuals who have worn a hearing aid for, at least, 12 months or never worn a hearing aid. All participants would be asked to complete, at 2 time points (t) including baseline (t=0) and follow-up (t=6 months), tests of hearing and psychosocial and cognitive function and attend a magnetic resonance imaging (MRI) session. The MRI session will include both structural and functional MRI (sMRI and fMRI) scans, the latter involving the performance of a novel speech processing task. RESULTS This research is funded by the Barbara Dicker Brain Sciences Foundation Grants, the Australian Research Council, Alison Hennessy Audiology, and Chelsea Hearing Pty Ltd under the Industry Transformation Training Centre Scheme (ARC Project #IC140100023). We obtained the ethics approval on November 18, 2017 (Swinburne University Human Research Ethics Committee protocol number SHR Project 2017/266). The recruitment began in December 2017 and will be completed by December 2020. CONCLUSIONS This is the first study to assess the effect hearing aid use has on neural, cognitive, and psychosocial factors in individuals with SNHL who have never used hearing aids. Furthermore, this study is expected to clarify the relationships among altered brain structure and function, psychosocial factors, and cognition in response to the hearing aid use. CLINICALTRIAL Australian New Zealand Clinical Trials Registry: ACTRN12617001616369; https://anzctr.org.au/Trial/Registration/TrialReview.aspx?ACTRN=12617001616369 (Accessed by WebCite at http://www.webcitation.org/70yatZ9ze) INTERNATIONAL REGISTERED REPOR RR1-10.2196/9916


2015 ◽  
Vol 26 (01) ◽  
pp. 068-079 ◽  
Author(s):  
Jürgen Kiessling ◽  
Melanie Leifholz ◽  
Steffen Unkel ◽  
Jörn Pons-Kühnemann ◽  
Charlotte Thunberg Jespersen ◽  
...  

Background: In-situ audiometry is a hearing aid feature that enables the measurement of hearing threshold levels through the hearing instrument using the built-in sound generator and the hearing aid receiver. This feature can be used in hearing aid fittings instead of conventional pure-tone audiometry (PTA), particularly in places where no standard audiometric equipment is available. Differences between conventional and in-situ thresholds are described and discussed for some particular hearing aids. No previous investigation has measured and compared these differences for a number of current hearing aid models by various manufacturers across a wide range of hearing losses. Purpose: The purpose of this study was to perform a model-based comparison of conventionally and in-situ measured hearing thresholds. Data were collected for a range of hearing aid devices to study and generalize the effects that may occur under clinical conditions. Research Design: Research design was an experimental and regression study. Study Sample: A total of 30 adults with sensorineural hearing loss served as test persons. They were assigned to three subgroups of 10 subjects with mild (M), moderate to severe (MS), and severe (S) sensorineural hearing loss. Intervention: All 30 test persons underwent both conventional PTA and in-situ audiometry with four hearing aid models by various manufacturers. Data Collection and Analysis: The differences between conventionally and in-situ measured hearing threshold levels were calculated and evaluated by an exploratory data analysis followed by a sophisticated statistical modeling process. Results: At 500 and 1500 Hz, almost all threshold differences (conventional PTA minus in-situ data) were negative, i.e., in the low to mid frequencies, hearing loss was overestimated by most devices relative to PTA. At 4000 Hz, the majority of differences (7 of 12) were positive, i.e., in the frequency range above 1500 Hz, hearing loss was frequently underestimated. As hearing loss increased (M→MS→S), the effect of the underestimation decreased. At 500 and 1500 Hz, Resound devices showed the smallest threshold deviations, followed by Phonak, Starkey, and Oticon instruments. At 4000 Hz, this observed pattern partly disappeared and Starkey and Oticon devices showed a reversed effect with increasing hearing loss (M→MS→S). Because of high standard errors for the estimates, only a few explicit rankings of the devices could be established based on significant threshold differences (5% level). Conclusions: Differences between conventional PTA and in-situ threshold levels may be attributed to (1) frequency, (2) device/hearing loss, and (3) calibration/manufacturer effects. Frequency effects primarily resulting in an overestimation of hearing loss by in-situ audiometry in the low and mid frequencies are mainly due to sound drain-off through vents and leaks. Device/hearing loss effects may be due to leakage as well as boundary effects because in-situ audiometry is confined to a limited measurement range. Finally, different calibration approaches may result in different offset levels between PTA and in-situ audiometry calibration. In some cases, the observed threshold differences of up to 10–15 dB may translate to varied hearing aid fittings for the same user depending on how hearing threshold levels were measured.


1995 ◽  
Vol 38 (4) ◽  
pp. 949-959 ◽  
Author(s):  
John H. Macrae

Excessive amplification by hearing aids causes temporary threshold shift (TTS) and permanent threshold shift (PTS). This investigation addressed the question whether it might be possible to predict the eventual amount of PTS caused by excessive amplification from the amount of TTS it causes after a day of hearing aid use. Asymptotic TTS (ATS) to be expected as a result of hearing aid use was predicted for 8 children with sensorineural hearing loss and the predicted ATS was compared with observed permanent deterioration of their thresholds attributed to hearing aid use. There was good agreement between the predicted ATS and observed PTS at 500 to 2000 Hz. It follows that, for prediction of PTS caused by hearing aid use, the mean of the sound levels produced in the ear by the hearing aid is the correct equivalent continuous level (ECL) to use and that the Modified Power Law (MPL) is the appropriate method of adjusting the predictions for sensorineural hearing loss, because these have been shown to be appropriate for prediction of TTS caused by hearing aid use. Predictions of the PTS to be expected for the children that were carried out using the MPL and the mean level as the ECL were in good agreement with the observed PTS at 500 to 2000 Hz, whereas predictions of PTS based on an alternative method of correction for sensorineural hearing loss (the Continuation Hypothesis) were significantly less than the observed amounts. The results of the PTS predictions therefore confirmed the conclusions drawn from the results of the ATS predictions.


2017 ◽  
Vol 28 (10) ◽  
pp. 941-949 ◽  
Author(s):  
Charles E. Bishop ◽  
Elgenaid Hamadain ◽  
Jason A. Galster ◽  
Mary Frances Johnson ◽  
Christopher Spankovich ◽  
...  

Background: Unilateral sensorineural hearing loss (USNHL) can have a negative impact on functions associated with the advantages of balanced, binaural hearing. Although single-sided deafness, which is a complete loss of audibility in one ear, has gained increased interest in the published research, there is a gap in the literature concerning hearing aid outcomes for individuals with residual, or otherwise “aidable,” hearing in the affected ear. Purpose: To assess hearing aid outcomes for a group of individuals with USNHL with residual, aidable function. Research Design: A quasi-experimental study of hearing aid outcomes with paired comparisons made between unaided and aided test conditions. Study Sample: A convenience sample of twenty-two individuals with USNHL, with sufficient residual hearing in the affected ear as to receive audibility from use of a hearing aid, were recruited into the study from September 2011 to August 2012. Intervention: Each participant was fit with a digital behind-the-ear hearing aid coupled to a custom ear mold. Data Collection and Analysis: Assessments were performed at baseline (unaided) and after a three-month field trial (aided) with primary outcomes involving objective measures in sound field yielding signal-to-noise ratio loss (SNR Loss) via the Quick Speech-in-Noise Test and word recognition scores (WRS) via the Northwestern University Auditory Test, No. 6. Outcomes also involved the administration of two well-established subjective benefit questionnaires: The Abbreviated Profile of Hearing Aid Benefit (APHAB) and the 49-item Speech, Spatial, and Qualities of Hearing Scale (SSQ49). Results: As a group, participants showed significantly improved median SNR Loss thresholds when aided in a test condition that included spatial separation of speech and noise, with speech stimuli directed toward the worse ear and noise stimuli directed toward the better ear (diff. = −4.5; p < 0.001). Hearing aid use had a small, though statistically significant, negative impact on median SNR Loss thresholds, when speech and noise stimuli originated from the same 0° azimuth (diff. = 1.0; p = 0.018). This was also evidenced by the median WRS in sound field (diff. = −6.0; p = 0.006), which was lowered from 98% in the unaided state to 92% in the aided state. Results from the SSQ49 showed statistically significant improvement on all subsection means when participants were aided (p < 0.05), whereas results from the APHAB were generally found to be unremarkable between unaided and aided conditions as benefit was essentially equal to the 50th percentile of the normative data. At the close of the study, it was observed that only slightly more than half of all participants chose to continue use of a hearing aid after their participation. Conclusions: We observed that hearing aid use by individuals with USNHL can improve the SNR Loss associated with the interference of background noise, especially in situations when there is spatial separation of the stimuli and speech is directed toward the affected ear. In addition, hearing aid use by these individuals can provide subjective benefit, as evidenced by the APHAB and SSQ49 subjective benefit questionnaires.


2021 ◽  
Vol 20 (5) ◽  
pp. 8-12
Author(s):  
T. Yu. Vladimirova ◽  
◽  
A. B. Martynova ◽  

The significance of asymmetric sensorineural hearing loss (ASNHL) is due to a special approach to diagnosis, followed by the process of hearing aids and auditory rehabilitation. Currently, there is no standard audiometric criterion for determining the forms of asymmetry, which significantly affects the assessment of the prevalence of ASNHL. The study aimed to assess the prevalence and classification of ASNHL forms in the older age group using two methods of calculation: 1) the difference in the average hearing threshold at speech frequencies (in the range of 0,5–4 kHz) ≥15 dB was detected in 14,14% of cases; 2) the different degree of hearing loss, according to the International classification, in the right and left ear was 35,98%. In most cases, asymmetry was manifested by bilateral sensorineural hearing loss of varying severity, prevailing in the group of long-livers – 82,6%. Given the potentially high prevalence of asymmetry depending on the audiological criterion, the results of the work are a reason for further research in the development of a unified method for verifying a clinically significant form of ASNHL.


1994 ◽  
Vol 3 (2) ◽  
pp. 71-77 ◽  
Author(s):  
James J. Dempsey ◽  
Mark Ross

A large number of personal amplifiers have recently become available commercially. These devices have not been classified as hearing aids by the FDA and are therefore not subject to the FDA rules and regulations governing the sales of hearing aid devices. In this investigation, several of these personal amplifiers were evaluated to determine potential benefits and problems for each device. The devices were evaluated electroacoustically and, also, subjectively by a group of adults with sensorineural hearing loss. The results of the electroacoustic evaluation revealed very sharply peaked frequency responses. The subjective evaluations revealed tremendous variability, with some preferences for power and low-frequency amplification. Clinical implications of these results and suggestions for further research are provided.


2014 ◽  
Vol 2014 ◽  
pp. 1-4 ◽  
Author(s):  
Nandini Vijaya Singham ◽  
Mimiwati Zahari ◽  
Mohammadreza Peyman ◽  
Narayanan Prepageran ◽  
Visvaraja Subrayan

Background. Our study aimed to investigate an association between ocular pseudoexfoliation (PXF) and sensorineural hearing loss (SNHL) and to compare them with age and sex matched controls without pseudoexfoliation.Method. This was a case-control study of 123 patients which included 68 cases with PXF (at least one eye) and 55 controls without pseudoexfoliation. Pure-tone audiometry (PTA) was done for these patients at sound frequencies taken as important for speech comprehension, that is, 250 Hertz (Hz), 500 Hz, 1000 Hz, and 2000 Hz.Results. There were 41 patients with pseudoexfoliation syndrome (PXE) and 27 with pseudoexfoliative glaucoma (PXEG). The majority of patients with hearing loss (60%;n=51) were PXF patients and the remaining 40%(n=34)were controls. Below average hearing thresholds were significantly higher in the pseudoexfoliation group compared to the control group (P=0.01; odds ratio (OR), 3.00; 95% confidence interval (CI), 1.25–7.19). However, there was no significant difference in the mean hearing threshold levels between the three groups (PXE, PXEG, and controls) in either ear (ANOVA, right ear:P=0.46and left earP=0.36).Conclusion. Our study found an association between PXF and SNHL, confirming that PXF can involve organs in the body other than the eye.


2015 ◽  
Vol 129 (4) ◽  
pp. 321-325 ◽  
Author(s):  
D Siau ◽  
B Dhillon ◽  
R Andrews ◽  
K M J Green

AbstractObjectives:This study aimed to report the bone-anchored hearing aid uptake and the reasons for their rejection by unilateral sensorineural deafness patients.Methods:A retrospective review of 90 consecutive unilateral sensorineural deafness patients referred to the Greater Manchester Bone-Anchored Hearing Aid Programme between September 2008 and August 2011 was performed.Results:In all, 79 (87.8 per cent) were deemed audiologically suitable: 24 (30.3 per cent) eventually had a bone-anchored hearing aid implanted and 55 (69.6 per cent) patients declined. Of those who declined, 26 (47.3 per cent) cited perceived limited benefits, 18 (32.7 per cent) cited reservations regarding surgery, 13 (23.6 per cent) preferred a wireless contralateral routing of sound device and 12 (21.8 per cent) cited cosmetic reasons. In all, 32 (40.5 per cent) suitable patients eventually chose the wireless contralateral routing of sound device.Conclusion:The uptake rate was 30 per cent for audiologically suitable patients. Almost half of suitable patients did not perceive a sufficient benefit to proceed to device implantation and a significant proportion rejected it. It is therefore important that clinicians do not to rush to implant all unilateral sensorineural hearing loss patients with a bone-anchored hearing aid.


Author(s):  
L. E. Golooanooa ◽  
E. V. Zhiunskaya ◽  
M. . Yu

164 patients with moderate to severe ehronie bilateral sensorineural hearing loss were asked to fill in the Glasgow hearing aid benefit profile. Its usefulness was showed in eases of diffieult hearing aid fitting.


Sign in / Sign up

Export Citation Format

Share Document