scholarly journals Selection of adhesive systems in treatment of tooth root caries (literature review)

Author(s):  
I. G. Romanenko ◽  
N. I. Chepurova ◽  
A. S. Zueva

Adhesive dentistry is the foundation on the basis of which there have been global changes in the concept of adhesion of composite materials in therapeutic dentistry, protocols for fixing ceramic restorations in orthopedic dentistry. But a number of unsolved problems remained – the adhesion of composite materials to sclerosed dentin and tooth root cement, the sensitivity of the components of the adhesive systems to the wet environment of the oral cavity and spatial stability in the presence of dentinal fluid moving centrifugally in the dentinal tubules, the lack of restoration of periodontal attachment to the defect that occurs during tooth root caries. The review analyzes the results of studies on the use of self-etching adhesive systems in the treatment of root caries. The physician's ability to choose an adhesive system in a particular clinical case demonstrates his fundamental knowledge and minimizes the percentage of errors that he can make during the treatment phase. 

2004 ◽  
Vol 12 (3) ◽  
pp. 171-176 ◽  
Author(s):  
Masahiro Yoshiyama ◽  
Junichi Doi ◽  
Yoshihiro Nishitani ◽  
Toshiyuku Itota ◽  
Franklin R. Tay ◽  
...  

Hybridized dentin permits dental treatments that were previously impossible with conventional techniques, opening new frontiers in modern adhesive dentistry. We have investigated the adhesive property of current bonding systems to caries-infected dentin by a microtensile bond strength test (µTBS) and transmission electron microscopy (TEM), and suggested that bonding resin could infiltrate into caries-infected dentin partially to embed carious bacteria within hybrid layers. We have named this concept of caries control as modified sealed restoration (MSR). On the other hand, Kuraray Medical Inc. (Tokyo, Japan) has developed an antibacterial adhesive system (ABF, now marketed in USA as Protect Bond). So as to evaluate the effectiveness of ABF on root caries control, we have examine the microtensile bond strengths (µTBS) of ABF to normal versus carious root dentin and the interfacial morphology by a scanning electron microscopy (SEM). ABF could form the hybrid-like structures by infiltrating into the surfaces of the root carious dentin, and the mean value of µTBS of ABF to root carious dentin was 23.0 MPa. These results suggested that MSR combined with ABF might be an advantageous minimal invasive therapy for root caries.


2020 ◽  
Vol 9 (2) ◽  
pp. 6-9
Author(s):  
A. A. Mamedov ◽  
V. B. Loschenov ◽  
N. S. Morozova ◽  
A. V. Ryabova ◽  
K. O. Ivannikova

In this work, the authors evaluate the effectiveness of various adhesive systems (AS) in the temporary teeth restoration with composite materials. For this study, the authors used temporary teeth extracted for orthodontic reasons or lost due to a physiological change. Enamel samples with dentin were made from these teeth. Rhodamine B fluorochrome was added to each of the adhesive systems used. For the greater practical significance of research results, adhesive systems of several generations (IV, V, and VII) were chosen. In each sample, a cavity was prepared, and adhesive preparation was carried out according to the AS manufacturer instructions, followed by restoration with a composite material. Then, longitudinal slits were made so that the areas of enamel and dentin for which an adhesive protocol and restoration were performed could be observed in their entirety. The effectiveness of various generations was determined by the depth of penetration of AS components into the dentinal tubules. Fluorescent confocal microscopy was used to visualize the penetration ability of AS. Based on the results of the study, the authors concluded that IV and V generations of AS are the most effective.


2018 ◽  
Vol 69 (10) ◽  
Author(s):  
Ioana Hodisan ◽  
Cristina Prejmerean ◽  
Tinca Buruiana ◽  
Doina Prodan ◽  
Loredana Colceriu ◽  
...  

The aim of this work was to reduce microleakage in giomer restorations by using innovative materials in both adhesive systems and light-cured dental giomer. Two adhesive systems with different primers were investigated. The innovative compounds in the primers were acrylic acid (AA)/itaconic acid (IA) copolymer modified with methacrylic groups and AA/IA/N-acryloyl-L-leucine copolymer grafted with methacrylic groups. In addition, the investigated new giomer G contains a pre-reacted glass based on the latter copolymer. The commercial Beautifil II giomer and the FL-Bond II adhesive system were used for comparison. Microleakage was evaluated by determining the scores and percentages of dye penetration lengths after thermocycling of a series of light-cured dental giomer restorations performed on 42 premolars extracted for orthodontic reasons. A lower microleakage value was recorded for the adhesive system containing the AA/IA/N-acryloyl-L-leucine copolymer grafted with methacrylic groups than for the commercial adhesive, which was in substantial agreement with SEM and AFM investigations. In this case, remarkable dentin sealing and a strong adhesion at the giomer restoration�tooth interface was observed, and the innovative adhesive was proven to be promising for dental applications.


2004 ◽  
Vol 18 (3) ◽  
pp. 253-259 ◽  
Author(s):  
Fabiana Mantovani Gomes França ◽  
Flávio Henrique Baggio Aguiar ◽  
Alex José Souza dos Santos ◽  
José Roberto Lovadino

The aim of this in vitro study was to evaluate quantitatively the microleakage in class V cavities restored with one-bottle and self-etching adhesive systems with and without previous acid etching. Two one-bottle adhesive systems (Single Bond and Prime & Bond 2.1) and one self-etching adhesive system (Clearfil Mega Bond) were used in this study. One hundred and twenty sound human premolar teeth were randomly divided into 6 groups, and 20 class V restorations were prepared in the root dentin to test each bonding system. Each bonding system was used with and without acid etching. Specimens were prepared, dyed with 2% methylene blue, sectioned, triturated, and evaluated with an absorbance spectrophotometer test in order to quantify the infiltrated dye. Results were statistically evaluated by ANOVA and Tukey-Kramer test. No statistically significant differences were found among the adhesive systems when no etching agent was used. However, the Single Bond adhesive system showed statistically significant lower microleakage means than Clearfil Mega Bond and Prime & Bond 2.1 when 37% phosphoric acid was used. Single Bond and Clearfil Mega Bond adhesive systems presented similar behavior when the manufacturers' instructions were followed.


2002 ◽  
Vol 16 (2) ◽  
pp. 115-120 ◽  
Author(s):  
César Augusto Galvão Arrais ◽  
Marcelo Giannini

The formation of a hybrid layer is the main bonding mechanism of current dentin-bonding systems. This study evaluated the morphology and thickness of the resin-infiltrated dentinal layer after the application of adhesive systems. The dentin-bonding agents were evaluated on flat dentinal preparations confected on the occlusal surfaces of human teeth. The test specimens were prepared and inspected under scanning electron microscopy at a magnification of X 2,000. The adhesive systems were responsible for different hybrid layer thicknesses (p < 0.05), and the mean values were: for Scotchbond MP Plus (SM), 7.41 ± 1.24mum; for Single Bond (SB), 5.55 ± 0.82mum; for Etch & Prime 3.0 (EP), 3.86 ± 1.17mum; and for Clearfil SE Bond (CB), 1.22 ± 0.45mum. The results suggest that the conventional three-step adhesive system (SM) was responsible for the thickest hybrid layer, followed by the one-bottle adhesive (SB). The self-etching adhesives, EP and CB, produced the formation of the thinnest hybrid layers.


2007 ◽  
Vol 31 (1) ◽  
pp. 35-40 ◽  
Author(s):  
Carla Miranda ◽  
Luiz Henrique Maykot Prates ◽  
Ricardo de Souza Vieira ◽  
Maria Cristina Marino Calvo

The aims of this study were to evaluate the shear bond strength (SBS) of four adhesive systems applied to primary dentin and enamel and verify, after SBS testing, the failure mode of the adhesive interface. Sixty extracted sound primary molars were selected and crowns were sectioned in a mesial-distal direction. Specimens were randomly assigned into two groups (adhesion to enamel and adhesion to dentin) and then subdivided into four subgroups according to the adhesive system (n=15): Scotchbond Multi-Purpose (SMP) – Single Bond (SB) – Clearfil SE Bond (and Adper Prompt LPop (APL) – SBS tests were performed and the obtained values were statistically analyzed using ANOVA and Tukey tests (p&lt;0.05). The failure mode analysis was performed with a Scanning Electron Microscope (XL-30, Philips). SBS mean values on enamel were [MPa (SD)]: SMP – 27.89 (7.49); SB – 23.92 (8.8); CSB – 24.36 (6.69); APL – 25.96 (4.08); and on dentin: SMP – 17.29 (4.25); SB – 18.2 (8.74); CSB – 16.13 (7.14); APL – 6.04 (3.35). The predominant failure mode was cohesive (primarily of the bonding agent). On enamel SBS was statistically similar for all four adhesives. On dentin SBS of APL was lower than the other tested adhesives.


2014 ◽  
Vol 62 (4) ◽  
pp. 365-370 ◽  
Author(s):  
Ricardo Alves dos SANTOS ◽  
Eliane Alves de LIMA ◽  
Mônica Maria de Albuquerque PONTES ◽  
Alexandre Batista Lopes do NASCIMENTO ◽  
Marcos Antônio Japiassú Resende MONTES ◽  
...  

OBJECTIVE: To assess the bond strength to dentin of the Single Bond (3M ESPE) and XP Bond (Dentsply) total-etch and Adper SE Plus (3M ESPE) self-etch adhesive systems. METHODS: Fifteen healthy human third molars were randomly allocated across three different groups of five teeth each according to the adhesive system. The occlusal portion of each tooth was removed under refrigeration using a flexible diamond disc (EXTEC, Enfield, CT, USA) down to an area of dentin that did not reveal enamel, as confirmed under a 40X stereo microscope (Ramsor, São Paulo, Brazil). A standardized smear layer was created with #600 grit silicon-carbide paper. The adhesive systems were applied as per manufacturer recommendations, with the exception of the Adper SE Plus system, which was triple-polymerized. Composite resin blocks (5 mm) were placed on the dentin surface. The specimens were stored in distilled water for 24 hours at 37ºC. Using a flexible diamond disc (EXTEC, Enfield, CT, USA), toothpick-like specimens with an adhesive area of less than 1 mm² were obtained. A microtensile bond test was then carried out using a universal testing machine (KRATOS) with a crosshead speed of 0.5 mm/min. Analysis of variance (ANOVA) and Tukey's test were used for comparisons. RESULTS: The bond strength values obtained with each adhesive system were as follows: XP Bond, 96.24 MPa; Adper Single Bond, 72.39 MPa; Adper SE Plus, 49.91 MPa. CONCLUSION: In terms of bond strength to dentin, conventional adhesives outperform self-etching systems.


2004 ◽  
Vol 12 (1) ◽  
pp. 12-17 ◽  
Author(s):  
Linda Wang ◽  
Marília Afonso Rabelo Buzalaf ◽  
Maria Teresa Atta

A dhesive systems associated to resin-modified glass ionomer cements are employed for the achievement of a higher bond strength to dentin. Despite this benefit, other properties should not be damaged. This study aimed at evaluating the short-time fluoride release of a resin-modified glass ionomer cement coated with two one-bottle adhesive systems in a pH cycling system. Four combinations were investigated: G1: Vitremer (V); G2: Vitremer + Primer (VP); G3: Vitremer + Single Bond (VSB) and G4: Vitremer + Prime & Bond 2.1 (VPB). SB is a fluoride-free and PB is a fluoride-containing system. After preparation of the Vitremer specimens, two coats of the selected adhesive system were carefully applied and light-cured. Specimens were immersed in demineralizing solution for 6 hours followed by immersion in remineralizing solution for 18 hours, totalizing the 15-day cycle. All groups released fluoride in a similar pattern, with a greater release in the beginning and decreasing with time. VP showed the greatest fluoride release, followed by V, with no statistical difference. VSB and VPB released less fluoride compared to V and VP, with statistical difference. Regardless the one-bottle adhesive system, application of coating decreased the fluoride release from the resin-modified glass ionomer cements. This suggests that this combination would reduce the beneficial effect of the restorative material to the walls around the restoration.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Mariana Almeida Mello Proença ◽  
Karime Tavares Lima da Silva ◽  
Alisson Costa e Silva ◽  
Edilausson Moreno Carvalho ◽  
José Bauer ◽  
...  

Objectives. The aim of this study was to evaluate the shear bond strength of metal brackets bonded with different universal adhesive systems containing 10-MDP and Transbond Plus Self Etching Primer after 20,000 thermal cycles. Materials and Methods. A total of 130 sound bovine teeth were used, which are divided into 5 groups (n = 26) according to the adhesive system used: All-Bond Universal (Bisco), Ambar Universal (FGM), Clearfil Universal Bond (Kuraray), Single Bond Universal (3M/ESPE), and Transbond Plus SEP (3M/ESPE) as control. The adhesives were applied for 20 seconds and bonded with a resin Transbond XT (3M/ESPE). After this, the teeth were submitted to 20,000 cycles at 5°C and 55°C. Afterwards, the shear bond strength test was performed in a universal test machine (Instron 3342). The adhesive remnant index (ARI) was evaluated under a stereomicroscope at 10x magnification and scanning electronic microscopy (SEM, Hitachi 3030). The shear bond strength data were submitted to One-Way ANOVA (α = 0.05) and the ARI to the Kruskal–Wallis test (α = 0.05). Results. Statistical analysis showed that the universal adhesive systems presented mean shear bond strength values similar to Transbond Plus SEP (p<0.05). The universal adhesive presented similar ARI values among them but differed from those of Transbond Plus SEP (p<0.001). Transbond Plus SEP presented a high ARI value when compared with the universal adhesive systems and high demineralization of enamel. Conclusions. The results show that universal adhesive systems may be used for bonding metal brackets if the orthodontist wants to maintain dental enamel health.


10.2341/05-20 ◽  
2006 ◽  
Vol 31 (2) ◽  
pp. 240-247 ◽  
Author(s):  
F. H. O. Mitsui ◽  
A. R. Peris ◽  
A. N. Cavalcanti ◽  
G. M. Marchi ◽  
L. A. F. Pimenta

Clinical Relevance Bond strength is affected by the combination of thermal and mechanical load cycling. However, results vary greatly with the number of mechanical cycles and adhesive system type (total or self-etching).


Sign in / Sign up

Export Citation Format

Share Document