scholarly journals Influence of whitening dentifrices and mechanical brushing on color change and surface roughness of bulk fill resins

2018 ◽  
Vol 17 ◽  
pp. 1-9
Author(s):  
Mayara Zaghi Dal Picolo ◽  
Lúcia Trazzi Pietro ◽  
Josué Junior Araujo Pierote ◽  
Suelem Chasse Barreto ◽  
Carlos Tadeu dos Santos Dias ◽  
...  

Abstract: The use of whitening dentifrices during oral hygiene may cause surface modifications such as color change (ΔE) and increase surface roughness (Ra) of composite resin. Aim: This study aimed to evaluate the effect of whitening dentifrices and mechanical brushing on color change and surface roughness of Bulk Fill (Filtek Bulk Fill - F) and (Aura Bulk Fill - A) composite resins. Materials and methods: Sixty cylindrical specimens were fabricated of each composite resin. After initial color evaluations (Konica Minolta CM-700d), with D65 standard illuminant, and the surface roughness (Surfcorder SE 1700, Kosalab), the specimens were assigned (n=10) according to the whitening dentifrice used: True White (T), Colgate Total 12 Professional Whitening (D), Luminous White Advanced (L). Specimens were submitted to mechanical brushing (10,000 cycles); new color and surface roughness evaluations were taken. Data were analyzed by ANOVA, Duncan test and Dunnet test were used to identify differences between groups (α=5%). Results: The results showed that the tooth brushing time promoted a significant increase in ΔE of the FT group. The FD group exhibited intermediate values of ΔE and was similar to all groups tested. There was a significant increase in the surface roughness of the AD and AT groups after the mechanical tooth brushing. Conclusion: The results showed no significant changes were observed in surface roughness for F groups after toothbrushing. It be concluded that the color change and surface roughness of the composite resins after toothbrushing are dependent on the interaction between the composition of the composite resin and the characteristics of the dentifrice.

2021 ◽  
Vol 23 (2) ◽  
pp. 85-91
Author(s):  
Guilherme Ortiz Pinto Cruz ◽  
Larissa Martins Costa ◽  
Cesar Penazzo Lepri ◽  
Ruchele Dias Nogueira ◽  
Regina Guenka Palma-Dibb ◽  
...  

AbstractThe aim of this study was to evaluate the color stability and the surface roughness of different composites brushed with toothpastes presenting different levels of abrasivity. Thirty discs of each material were obtained using michohybrid composites (Brilliant NG and Charisma Diamond) and a nanocomposite (Filtek Z350XT). The initial color (CIELab) and surface roughness (confocal laser scanning microscopy) of resin discs were evaluated. Afterwards, 10 specimens per group were brushed with the following dentifrices: Maximum Cavity Protection, Sensodyne Repair & Protect and Colgate Sensitive Pro-Relief. Brushing was performed with an electric toothbrush equipped with soft bristle head, with standard power and weight, for 30 minutes. Every 30 seconds, 1.0 ml of the slurry was injected between the bristles of the brush and the specimen. After abrasive challenge, the samples had their color and roughness reevaluated. Data were submitted to the Kruskal-Wallis test (color change) or the t-test (surface roughness). The level of significance was 5%. Results: Brushing did not significantly change the color of the composites tested in the study herein . On the other hand, the surface roughness of the composites was significantly affected by the abrasive challenge, regardless of the toothpaste used. The surface roughness change was similar for all the composites. The abrasive challenge with the toothpastes Maximum Cavity protection, Sensodyne Repair & Protect and Colgate Sensitive Pro-Relief was not able to significantly change the color of the composite resins. Nevertheless, the abrasive challenges significantly altered the surface roughness of all the evaluated composites. However, the changes in surface roughness were statistically similar in the microhybrid and nanofilled composites. Keywords: Composites Resins. Dentifrices. Color. ResumoO objetivo deste estudo foi avaliar a estabilidade de cor e a rugosidade superficial de diferentes resinas compostas escovadas com dentifrícios de diferentes níveis de abrasividade. Trinta discos de cada material foram obtidos utilizando compósitos micro-híbridos (Brilliant NG e Charisma Diamond) e um nanocompósito (Filtek Z350XT). A cor inicial (CIELab) e a rugosidade superficial (microscopia confocal de varredura a laser) dos discos de resina foram avaliadas. Em seguida, 10 amostras por grupo foram escovadas com os dentifrícios Máxima Proteção Anticáries, Sensodyne Repair & Protect e Colgate Sensitive Pro-Alívio. A escovação foi realizada com uma escova elétrica com cabeça de cerdas macias, com potência e peso padronizados, durante 30 minutos. A cada 30 segundos, 1,0 ml da pasta era injetada entre as cerdas da escova e a amostra. Após o desafio abrasivo, as amostras tiveram sua cor e rugosidade reavaliadas. Os dados foram submetidos ao teste de Kruskal-Wallis (alteração de cor) ou ao teste t (rugosidade da superfície) (α=5%). A escovação não alterou significativamente a cor dos compósitos. Por outro lado, a rugosidade superficial dos compósitos foi significativamente afetada pelo desafio abrasivo, independentemente do dentifrício utilizado. A alteração da rugosidade superficial foi semelhante para todos os compósitos. O desafio abrasivo com a Máxima Proteção Anticáries, o Sensodyne Repair & Protect e o Colgate Sensitive Pro-Alívio não foi capaz de alterar significativamente a cor das resinas. Diferentemente, os desafios abrasivos alteraram significativamente a rugosidade superficial de todos os compósitos avaliados. No entanto, as mudanças na rugosidade foram estatisticamente semelhantes nos compósitos micro-híbridos e nanoparticulado. Palavras-chave: Resinas Compostas. Dentifrícios. Cor.


2020 ◽  
Vol 33 (2) ◽  
pp. 59-68
Author(s):  
Bruna Tavares ◽  
Fabiana França ◽  
Roberta Basting ◽  
Basting Turssi ◽  
Turssi Amaral

The aim of this in vitro study was to evaluate the effect of bleaching protocols on the surface roughness (Ra), color change and surface micromorphology of a low-viscosity bulk-fill composite (Filtek Bulk Fill Flow, 3M ESPE), a highviscosity bulk-fill composite (Filtek Bulk Fill, 3M ESPE) and a conventional nanoparticulate composite resin (control) (Filtek Z350 XT, 3M ESPE). Forty samples of each composite (disks 5 mm in diameter and 2 mm thick) were randomly divided into four groups (n=10), according to bleaching protocol: a) 10% carbamide peroxide gel (Opalescence, Ultradent Products) (2 h/ day, for 14 days); b) 40% hydrogen peroxide gel (Opalescence Boost, Ultradent Products) (three bleaching sessions, once a week, 45 min/session); c) whitening rinse (Listerine Whitening Extreme, Johnson & Johnson) (2 min/day, for 14 days); and d) distilled water (control). The samples were submitted to triplicate readings (Ra and color [CIELAB parameters]) before and after contact with bleaching protocols. Micromorphology was analyzed in a scanning electron microscope (SEM). Ra and color parameters (ΔL, Δa, Δb and ΔE) were analyzed by generalized linear models (α=0.05). The Ra of the high-viscosity bulk-fill was significantly higher than that of the other composites (p<0.05). Ra increased significantly (p<0.05) and surface became more irregular (SEM analysis) in all the composite resins, regardless of the bleaching protocol (p<0.05). The high-viscosity bulk-fill composite resin group had significantly lower ΔE (p<0.05) than the nanoparticulate composite resin group immersed in distilled water. It was concluded that the characteristics of each resin significantly influenced the Ra more than the bleaching protocol. The high-viscosity bulk-fill resin presented minor color change.


2012 ◽  
Vol 37 (5) ◽  
pp. 526-531 ◽  
Author(s):  
CRG Torres ◽  
CF Ribeiro ◽  
E Bresciani ◽  
AB Borges

SUMMARY The aim of the present study was to evaluate the effect of 20% and 35% hydrogen peroxide bleaching gels on the color, opacity, and fluorescence of composite resins. Seven composite resin brands were tested and 30 specimens, 3-mm in diameter and 2-mm thick, of each material were fabricated, for a total of 210 specimens. The specimens of each tested material were divided into three subgroups (n=10) according to the bleaching therapy tested: 20% hydrogen peroxide gel, 35% hydroxide peroxide gel, and the control group. The baseline color, opacity, and fluorescence were assessed by spectrophotometry. Four 30-minute bleaching gel applications, two hours in total, were performed. The control group did not receive bleaching treatment and was stored in deionized water. Final assessments were performed, and data were analyzed by two-way analysis of variance and Tukey tests (p&lt;0.05). Color changes were significant for different tested bleaching therapies (p&lt;0.0001), with the greatest color change observed for 35% hydrogen peroxide gel. No difference in opacity was detected for all analyzed parameters. Fluorescence changes were influenced by composite resin brand (p&lt;0.0001) and bleaching therapy (p=0.0016) used. No significant differences in fluorescence between different bleaching gel concentrations were detected by Tukey test. The greatest fluorescence alteration was detected on the brand Z350. It was concluded that 35% hydrogen peroxide bleaching gel generated the greatest color change among all evaluated materials. No statistical opacity changes were detected for all tested variables, and significant fluorescence changes were dependent on the material and bleaching therapy, regardless of the gel concentration.


2021 ◽  
Vol 7 (7) ◽  
pp. 67267-67276
Author(s):  
Emillyn Jones Greijal Dias Holanda ◽  
José Guilherme Neves ◽  
Milton Santamaria-Jr ◽  
Silvia Amélia Scudeler Vedovello ◽  
Ana Rosa Costa ◽  
...  

The aim of this study was to evaluate the surface properties of orthodontic resins with and without fluoride. Forty disks, measuring 2 mm thick by 6 mm in diameter, were made of 4 bracket-bonding composite resins (n=10): Transbond Plus Color Change-3M/Unitek (TPCC); Transbond XT- 3M/Unitek (TXT), Orthocem -FGM (OC); Orthocem UV Trace-FGM (OCUV). The discs were photoactivated for 40 seconds with irradiance of 450 mW/cm2 and manually polished in sequence by silicon carbide sandpapers with 1200 and 2000 grain size and finished with diamond paste and felt disc. The surface microhardness analysis was performed using a Shimadzu Micro Hardness Tester HMV-2,000 (Shimadzu Corporation, Kyoto, Japan) with a load of 50 gF and a 5 second penetration time. Surface roughness readings were taken using a Surf Corder Roughness Meter (SE 1700- Kosaka, Lisboa-Portugal). For data analysis, ANOVA (one-way) was used, followed by Tukey's post-test (?=0.05). The microhardness results showed a difference (p?0.05) in the means of the orthodontic resins between TPCC and TXT with the other groups. After the surface roughness analysis, the averages showed that TPCC resin showed higher roughness compared to OC and OCUV (p?0.05), and there was no statistical difference with TXT. It was concluded that statistically the composite resins with fluoride showed significant difference regarding hardness and roughness.


2017 ◽  
Vol 18 (4) ◽  
pp. 283-288 ◽  
Author(s):  
Cleidiel AA Lemos ◽  
Silvio J Mauro ◽  
Paulo H dos Santos ◽  
André LF Briso ◽  
Ticiane C Fagundes

ABSTRACT Aim The aim of this study was to investigate the association of different degradations on the roughness, gloss, and color changes of microhybrid composites. Materials and methods Ten specimens were prepared for Charisma, Amelogen Plus, Point 4, and Opallis resins. Surfaces were polished and baseline measurements of roughness, gloss, and color were recorded. Specimens were then submitted to chemical and mechanical challenges, and the specimens were reevaluated. Roughness and gloss were analyzed by Kruskal – Wallis and Dunn's test (p < 0.05). Color change (ΔE) was analyzed by one-way analysis of variance and Tukey's tests (p < 0.05). The initial and final data were compared using the Wilcoxon test (p < 0.05). Spearman test checked the correlation between the roughness and gloss (p < 0.05). Results Regarding surface roughness and gloss, there was no difference between composites before challenges. However, all composites showed a significant increase of roughness after challenges, with highest values for Charisma. The gloss was influenced by challenges, evidencing the best gloss for Point 4. Charisma showed the highest value of color change. There was no correlation between surface roughness and gloss for the initial analysis, and after the challenges. Conclusion Composites were influenced by association of challenges, and Charisma showed the highest changes for roughness, gloss, and color. Clinical significance The type of composite resin influenced the properties of materials, which are surface roughness, gloss, and color change. The dentist should be aware of the performance of different brands, to choose the correct required composite resin for each type of patient or region to be restored. How to cite this article Lemos CAA, Mauro SJ, dos Santos PH, Briso ALF, Fagundes TC. Influence of Mechanical and Chemical Degradation in the Surface Roughness, Gloss, and Color of Microhybrid Composites. J Contemp Dent Pract 2017;18(4):283-288.


2013 ◽  
Vol 07 (02) ◽  
pp. 165-171 ◽  
Author(s):  
Duygu Tuncer ◽  
Emel Karaman ◽  
Esra Firat

ABSTRACT Objective: To investigate the effect of beverages′ temperature on the surface roughness, hardness, and color stability of a composite resin. Materials and Methods: Fifty specimens of the Filtek Z250 composite (3M ESPE, Dental Products, St.Paul, MN, USA) were prepared and initial roughness, microhardness, and color were measured. Then the specimens were randomly divided into five groups of 10 specimens each: Coffee at 70°C, coffee at 37°C, cola at 10°C, cola at 37°C, and artificial saliva (control). After the samples were subjected to 15 min × 3 cycles per day of exposure to the solutions for 30 days, the final measurements were recorded. Results: After immersion in beverages, the artificial saliva group showed hardness values higher than those of the other groups (P < 0.001) and the microhardness values were significantly different from the initial values in all groups except for the control group. Both cola groups showed roughness values higher than the baseline values (P < 0.05), while the other groups showed values similar to the baseline measurements. When ΔE measurements were examined, the 70°C coffee group showed the highest color change among all the groups (P < 0.05). Conclusion: High-temperature solutions caused alterations in certain properties of composites, such as increased color change, although they did not affect the hardness or roughness of the composite resin material tested.


2006 ◽  
Vol 17 (1) ◽  
pp. 29-33 ◽  
Author(s):  
Janisse Martinelli ◽  
Fernanda de Carvalho Panzeri Pires-de-Souza ◽  
Luciana Assirati Casemiro ◽  
Camila Tirapelli ◽  
Heitor Panzer

This study compared the abrasion resistance of direct composite resins cured by light-emitting diodes (LED) and halogen light-curing units. Twenty specimens (12 mm in diameter; 1.0 mm thick) of each composite resin [TPH (Dentsply); Definite (Degussa); Charisma (Heraus Kulzer)] were prepared using a polytetrafluoroethylene matrix. Ten specimens per material were cured with the LED source and 10 with the halogen lamp for 40 s. The resin discs were polished, submitted to initial surface roughness reading (Ra initial - mum) in a roughness tester and stored in water at 37°C for 15 days. The specimens were weighed (M1) and submitted to simulated toothbrushing using slurry of water and dentifrice with high abrasiveness. After 100 minutes in the toothbrushing simulator, the specimens were cleaned, submitted to a new surface roughness reading (Ra final - mum) and reweighed (M2). Mass loss was determined as the difference between M1 and M2. Data were recorded and analyzed statistically by one-way ANOVA and Tukey Test at 5% significance level. The composite resin with greater size of inorganic fillers (TPH) showed the lowest mass loss and surface roughness means, indicating a higher resistance to toothbrush abrasion (p<0.05). Definite cured with LED presented the least resistance to toothbrush abrasion, showing the highest means of surface roughness and mass loss (p<0.05). The LED source did not show the same effectiveness as the halogen lamp for polymerizing this specific composite resin. When the composite resins were cured a halogen LCU, no statistically significant difference was observed among the materials (p>0.05). It may be concluded that the type of light-curing unit and the resin composition seemed to interfere with the materials' resistance to abrasion.


2005 ◽  
Vol 16 (1) ◽  
pp. 39-44 ◽  
Author(s):  
Silvia Helena Barbosa ◽  
Régia Luzia Zanata ◽  
Maria Fidela de Lima Navarro ◽  
Osvaldo Benoni Nunes

This study examined the average surface roughness (Ra, µm) of 2 microfilled (Durafill and Perfection), 1 hybrid (Filtek Z250) and 2 packable composite resins (Surefil and Fill Magic), before (baseline) and after eight different finishing and polishing treatments. The surface roughness was assessed using a profilometer. Ten specimens of each composite resin were randomly subjected to one of the following finishing/polishing techniques: A - carbide burs; B - fine/extrafine diamond burs; C - Sof-Lex aluminum oxide discs; D - Super-Snap aluminum oxide discs; E - rubber polishing points + fine/extrafine polishing pastes; F - diamond burs + rubber polishing points + fine/extrafine polishing pastes; G - diamond burs + Sof-Lex system; H - diamond burs + Super-Snap system. Data were analyzed using two-way ANOVA and Tukey's HSD test. Significant differences (p<0.05) were detected among both the resins and the finishing/polishing techniques. For all resins, the use of diamond burs resulted in the greatest surface roughness (Ra: 0.69 to 1.44 µm). The lowest Ra means were obtained for the specimens treated with Sof-Lex discs (Ra: 0.11 to 0.25 µm). The Ra values of Durafill were lower than those of Perfection and Filtek Z250, and these in turn had lower Ra than the packable composite resins. Overall, the smoothest surfaces were obtained with the use the complete sequence of Sof-Lex discs. In areas that could not be reached by the aluminum oxide discs, the carbide burs and the association between rubber points and polishing pastes produced satisfactory surface smoothness for the packable and hybrid composite resins, respectively.


2019 ◽  
Vol 44 (1) ◽  
pp. 65-75 ◽  
Author(s):  
JW Reinhardt ◽  
MM Balbierz ◽  
CM Schultz ◽  
B Simetich ◽  
MW Beatty

SUMMARY In this laboratory study, a composite resin was stained to a visibly discernible level using both coffee and red wine over 14 days (change was considered clinically noticeable and significant when ΔEab*≥2.7). Color change was measured at one, three, seven, and 14 days of staining. Although the nature of color change was different for the two staining solutions, the overall degree of staining (ΔEab*) rendered by either coffee or wine at each time interval was not significantly different (p≥0.05). Four whitening protocols were applied to stained composites. Treatment included applications of distilled water (control), Crest Pro-Health [HD] toothpaste, Crest Whitestrips, Opalescence PF bleach (15%), and application of a fine pumice polishing (Preppies). HD toothpaste and Whitestrips were applied daily for 21 days, Opalescence was applied daily for 10 days, and polishing was applied once. Each of the whitening products, applied in a manner simulating at-home or in-office treatment, was effective in producing color improvements (lightening) over controls (p&lt;0.05), but none of the four treatments produced lightening that was significantly different from the other treatments (p≥0.05). A comparison of final composite color with that measured at baseline showed that Opalescence returned composite color to an acceptable level following exposure to both staining solutions (ΔEab*&lt;2.7), Whitestrips returned color close to baseline for wine-stained composites, and HD paste and polishing permitted residual stain to remain (ΔEab*≥2.7).


2015 ◽  
Vol 26 (5) ◽  
pp. 507-513 ◽  
Author(s):  
Lourenço de Moraes Rego Roselino ◽  
Michelle Alexandra Chinelatti ◽  
Carla Cecilia Alandia-Román ◽  
Fernanda de Carvalho Panzeri Pires-de-Souza

Abstract: Dentifrice abrasiveness and brushing time may increase color change (∆E) and surface roughness (∆Ra) of resin composites. This study aimed to evaluate the effect of mechanical brushing time of dentifrices with different abrasiveness on ∆E and ∆Ra of nanofilled (Z350, 3M ESPE) and nanohybrid (Tetric N-Ceram, Ivoclar Vivadent) resin composites. Sixteen specimens (12 mm diameter x 2 mm thick) were fabricated using a white Teflon matrix of each resin composite and a ceramic (IPS e.max Ceram, Ivoclar Vivadent), used as control. After initial color readouts on white backgrounds (Spectrophotometer PCB 6807, Byk Gardner), with D65 standard illuminant, and surface roughness (Rugosimeter Surfcorder SE 1700, Kosalab) with cut-off=0.8 mm and speed=0.25 mm/s, specimens were assigned (n=8) according to the abrasiveness of the dentifrices: RDA* 68 (Colgate) and RDA* 180 (Colgate Total Plus Whitening). Specimens were submitted to mechanical brushing (58,400 cycles) and after every 14,600 cycles (1 year of brushing by a healthy individual), new color and surface roughness readouts were taken. Color stability was calculated by CIEDE2000. Data were analyzed by 3-way repeated measures ANOVA and Bonferroni test (p<0.05), and demonstrated that the dentifrice abrasiveness (p=0.02) and brushing time (p<0.0001) affected the ∆E of nanofilled resin composite. There was no difference on surface roughness of materials (p=0.6752) or brushing time (p=0.7997). In conclusion, the longer the brushing time and dentifrice abrasiveness, the greater the color change of the nanofilled resin composite. The surface roughness was not influenced by dentifrice abrasiveness.


Sign in / Sign up

Export Citation Format

Share Document