scholarly journals A simple isocratic RP-HPLC method for quality control of oseltamivir capsules

2012 ◽  
Vol 31 (2) ◽  
pp. 205
Author(s):  
Agim Ameti ◽  
Jasmina Slavkovska ◽  
Katerina Starkoska ◽  
Zorica Arsova-Sarafinovska

A simple isocratic reversed-phase high performance liquid chromatographic (RP-HPLC) method was developed for determination of oseltamivir active pharmaceutical ingredient (API) in bulk drug and pharmaceuticals. The separation was achieved on a Purospher STAR® RP – 18e column with a mobile phase consisting of methanol- 0.02 mol l-1 phosphate buffer, pH 5, 50:50 (v/v). Chromatographic results demonstrated the specificity of the method for determination of oseltamivir in presence of degradation products generated in studies of forced decomposition. The limit of detection (LOD) and limit of quantification (LOQ) for oseltamivir phosphate were 0,0162 μg ml-1 and 0,0491 μg ml-1, respectively. The advantages of this method include simple sample treatment and short elution time (less than 6 min). Furthermore, using methanol instead of acetonitrile in a mobile phase composition considerably reduces the laboratory expenses, still retaining adequate sensitivity for routine analysis as well as for evaluation of potentially counterfeit Tamiflu® products. 

2021 ◽  
Vol 10 (1) ◽  
pp. 20-28
Author(s):  
Ivana Savić-Gajić ◽  
Ivan Savić ◽  
Predrag Sibinović ◽  
Valentina Marinković

In this study, the modified stability-indicating RP-HPLC method was validated for quantitative analysis of amlodipine besylate in the presence of its impurity D (3-ethyl 5-methyl 2-[(2-aminoethoxy)methyl]-4-(2-chlorophenyl)-6-methylpyridine-3,5-dicarboxylate). The method was applied for the determination of an analyte in the tablets and irradiated samples packed in the primary packaging (Alu/PVC/PVDC blister packaging). The efficient chromatographic separation was achieved using a ZORBAX Eclipse XDB-C18 column (4.6×250 mm, 5 mm) with isocratic elution of mobile phase which consisted of acetonitrile:methanol:triethylamine solution (15:35:50, v/v/v) (pH 3.0). The flow rate of the mobile phase was 1 mL min-1, while the detection of amlodipine besylate was carried out at 273 nm. Amlodipine besylate and its impurity D were identified at the retention times of 16.529 min and 2.575 min, respectively. The linearity of the method with the coefficient of determination of 0.999 was confirmed in the concentration range of 10 - 75 µg mL-1 for amlodipine besylate. The limit of detection was 0.2 µg mL-1, while the limit of quantification was 0.66 µg mL-1. After UV and Vis radiation of the tablets packed in the primary packaging, the content of amlodipine besylate was reduced by 22.38% and 19.89%, respectively. The presence of new degradation products was not detected under the given chromatographic conditions. The photodegradation of amlodipine besylate followed pseudo-first-order kinetics. Based on the half-life of amlodipine besylate (38.4 days for UV radiation and 43.3 days for Vis radiation), it was concluded that amlodipine besylate in the tablets has satisfactory photostability after its packing in the Alu/PVC/PVDC blister packaging.


2020 ◽  
Vol 11 (1) ◽  
pp. 781-789
Author(s):  
Sriram Valavala ◽  
Nareshvarma Seelam ◽  
Subbaiah Tondepu ◽  
Suresh Kandagatla

The present study aims to develop a simple, accurate and specific stability-indicating RP-HPLC technique for the analysis of metoclopramide in the presence of its stress degradation products and characterization of degradation compounds by LC-MS/MS analysis. As per ICH Q1A-R2 guidelines, the drug was exposed to acid hydrolytic stress condition. Three degradation products were formed for MCP in acid hydrolysis. The liquid chromatography was processed on a Luna C18-(2) 100A,250×4.6mm 5micron column using an isocratic mobile phase consisting of 0.1% formic acid in water-acetonitrile (20:80, v/v) by adjusting the mobile phase at 1 ml/min flow rate with wavelength detection at 273 nm. The developed procedure was applied to LC-MS/MS (liquid chromatography-tandem mass spectrometry) for the characterization of all the degradant components. Total new three degradation compounds were recognized and identified by LC-MS/MS. The developed RP-HPLC technique was validated as per the ICH Q2-R1 guidelines. Limit of detection and limit of quantification values of MCP were evaluated from the linearity graph and were found to be 5.23 µg/ml and 17.44 µg/ml. Accuracy study was established at 80.0, 100.0 and 120.0 µg/ml concentration levels and the findings were found in the range of 98.4% - 101.8%. The linearity of the technique was assessed over the drug concentration range of 50.0 µg/ml to 250.0 µg/ml and the regression equation, slope and correlation coefficient values were found to be y = 10618x + 1623.2, 10618 and 0.9996 respectively. The developed technique was uninterruptedly applied for the quantification of metoclopramide inactive pharmaceuticals.


2017 ◽  
Vol 60 (4) ◽  
Author(s):  
Guadalupe Pérez-Caballero ◽  
Nancy Muro-Hidalgo ◽  
Elvia Adriana Morales-Hipólito ◽  
Alma Villaseñor ◽  
Raquel López-Arellano

A reversed phase high-performance liquid chromatography (RP-HPLC) method for determination of Thimerosal (TMS) in topical creams was optimized and validated according to the ICH guidelines which include accuracy, precision, selectivity, robustness, limit of detection (LOD), limit of quantification (LOQ), linearity and range. For topical creams, sample treatment is often an overwhelming step essentially due to its oily nature. For the first time a simple and robust extraction procedure for TMS using phosphate buffer (pH 5.5, 0.2M) was successfully developed. This method describes the TMS quantitation by HPLC in a topical product containing 0.01% fluocinolone acetonide (FLA) as the active molecule. The HPLC separation was achieved on a Column Symmetry® and a methanol: phosphate buffer (pH 2.5, 0.05M) 70:30 v/v mobile phase and wavelength 218 nm. Results from both standards and samples showed adequate validation parameters. Noteworthy, linearity was within the range 1.2 - 2.8 μg/mL. Additionally, robustness and TMS stability were established after sample extraction. The method provides an efficient and safe quality control tool for determination of TMS in topical creams.


Author(s):  
SYED IBRAHIM BAJE ◽  
B. JYOTHI ◽  
N. MADHAVI

Objective: The objective of the present study was to develop and validate a novel reverse phase high performance liquid chromatographic (RP-HPLC) method, for simultaneous determination of ritonavir (RIT), ombitasvir (OMB) and paritaprevir (PAR) in bulk mixtures, and in tablets. Methods: Determination of the drugs ritonavir (RIT), ombitasvir (OMB), and paritaprevir (PAR), was carried out applying Hypersil BDS C18 column (250 mm X 4.6 mm i.e., 5 µm particle size), with photodiode array detector at λmax of 254 nm. The mobile phase applied for the current study composed of two solvents, i.e. A (0.01N % w/v potassium di-hydrogen orthophosphate buffer, pH 3.0 adjusted with dilute orthophosphoric acid) and B (acetonitrile). The mobile phase was pumped at a flow rate of 1.0 ml/min in the isocratic mode. The validation study with respect to specificity, linearity, precision, accuracy, and robustness, limit of detection (LOD) and limit of quantification (LOQ) was carried out employing the ICH guidelines. Results: Ritonavir, ombitasvir, and paritaprevir showed linearity of response between 12.5-75 μg/ml for ritonavir, 3.125-18.75 µg/ml for ombitasvir and 18.75–112.5 µg/ml for paritaprevir, with a correlation coefficient (R2) 0.999, 0.999,0.999 for RIT, OMB, and PAR respectively. The % recovery obtained was 99.82±0.14 % RIT, OMB 100.03±0.96 % and for 99.96±0.26 % PAR. The LOD and LOQ values for RIT, OMB, PAR were obtained to be 0.02, 0.019and0.02, µg/ml and 0.07, 0.06 and 0.07 µg/ml, respectively. The method also exhibits good robustness for different chromatographic conditions like wavelength, flow rate, mobile phase, and injection volume. Conclusion: The method was successfully employed, for the quantification of RIT, OMB, and PAR, in the quality control of in-house developed tablets, and can be applied for the industrial use.


Author(s):  
Ibrahim M. Abdulbaqi ◽  
Yusrida Darwis ◽  
Nurzalina Abdul Karim Khan ◽  
Reem Abou Assi ◽  
Gabriel Onn Kit Loh

Objective: To develop and validate a stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method for the determination of colchicine in bulk and ethosomal gel nano-formulation.Methods: The chromatographic conditions were optimized using stainless steel Hypersil Gold C-18 analytical column with the dimensions of 250 mm x 4.6 mm ID x 5 µm. The mobile phase consisted of acetonitrile and ammonium acetate buffer (20 mmol/l, pH=4.85) in the ratio of 32:68 v/v. The flow rate was set at 1 ml/min and the detection wavelength was 353 nm. The column was maintained at 30 °C and the injection volume was 10 µl. The stability of colchicine in different conditions was investigated by exposing the drug to stress degradation using acid, base, oxidation, heat and light.Results: There was no interference from excipients, impurities, dissolution media or degradation products at the retention time of colchicine 5.9 min indicating the specificity of the method. The limit of detection (LOD) and the limit of quantification (LOQ) were 8.64 ng/ml and 26.17 ng/ml respectively. The drug showed good stability under heat, acid, oxidation and light, but substantial degradation was observed under alkali condition. The procedure was validated for specificity, linearity, accuracy and precision.Conclusion: A simple, rapid, specific and stability-indicating HPLC–UV method for the determination of colchicine in the pure and ethosomal gel was successfully developed. The developed method was statistically confirmed to be accurate, precise, and reproducible.


Author(s):  
Murlidhar V. Zope ◽  
Rahul M. Patel ◽  
Ashwinikumari Patel ◽  
Samir G. Patel

Objective: The objective of the current study was to develop and validate a simple, robust, precise and accurate RP-HPLC (reverse phase-high performance liquid chromatography) method for the quantitative determination of potential degradation products of Difluprednate (DIFL) in the ophthalmic emulsion.Methods: Chromatographic separation was achieved on the YMC pack ODS-AQ (150× 4.6) mm, 3μm column with a mobile phase containing a gradient mixture of mobile phase A (0.02M Ammonium formate buffer pH 4.5 adjusted with formic acid) and Acetonitrile as mobile phase B, at flow rate of 1.5 ml/min and with UV detection at 240 nm.Results: The peak retention time of DIFL was found at about 17.2 min, the RRT of degradation product-1 (DP-1), degradation product-2 (DP-2), and degradation product-3 (DP-3), were found to be about 0.49, 0.65 and 0.79 respectively (calculated with respect to Difluprednate). Stress testing was performed in accordance with an ICH (international council for harmonisation) guideline Q1A (R2) [1]. The method was validated as per ICH guideline Q2 (R1)[2]. The calibration curve was found to be linear in the concentration range of 0.1 to 0.75 µg/ml for Difluprednate, DP-1, DP-2 and DP-3. The LOD (Limit of detection) was found to be 0.1µg/ml and LOQ (Limit of quantification) of 0.15µg/ml for Difluprednate, DP-1, DP-2 and DP-3 respectively. The recovery from LOQ to 150% was within 90-110%. The forced degradation data confirms the stability indicating the nature of the method.Conclusion: A simple, robust, precise and accurate RP-HPLC method for the quantitative determination of potential degradation products of Difluprednate in the ophthalmic emulsion was developed and validated. 


2018 ◽  
Vol 17 (1) ◽  
pp. 43-50
Author(s):  
Sherejad Sanam ◽  
Sharmin Nahar ◽  
Nazmus Saqueeb ◽  
SM Abdur Rahman

A stability indicating HPLC method was developed and validated for the quantitative determination of fexofenadine hydrochloride. An isocratic separation was achieved using phenomenex (C18) column (250×4.6 mm, 5 μm) with flow rate of 1.0 ml/min and UV detection at 254 nm. The mobile phase consists of 5Mm acetate buffer: acetonitrile (50:50; v/v) with pH 9.4 adjusted with acetic acid. The drug was subjected to oxidative, acidic, basic, neutral, photolytic and thermal degradation. All degradation products were eluted in an overall analytical run time of approximately 40 min with the parent compound fexofenadine hydrochloride at a flow rate of approximately 3.3±0.3 min. The method was linear over the concentration range of 31.5-500 μg/ml (r2 = 0.999) with limit of detection and quantification of 3.5 μg/ml and 10.1 μg/ml, respectively. The method has the requisite accuracy, selective, precision and robustness to assay fexofenadine HCl in tablets.Dhaka Univ. J. Pharm. Sci. 17(1): 43-50, 2018 (June)


Separations ◽  
2021 ◽  
Vol 8 (1) ◽  
pp. 5
Author(s):  
Mohd Afzal ◽  
Mohd. Muddassir ◽  
Abdullah Alarifi ◽  
Mohammed Tahir Ansari

A highly specific, accurate, and simple RP-HPLC technique was developed for the real-time quantification of domperidone (DOMP) and lansoprazole (LANS) in commercial formulations. Chromatographic studies were performed using a Luna C8(2), 5 μm, 100Å, column (250 × 4.6 mm, Phenomenex) with a mobile phase composed of acetonitrile/2 mM ammonium acetate (51:49 v/v), pH 6.7. The flow rate was 1 mL·min−1 with UV detection at 289 nm. Linearity was observed within the range of 4–36 µg·mL−1 for domperidone and 2–18 µg·mL−1 for lansoprazole. Method optimization was achieved using Box-Behnken design software, in which three key variables were examined, namely, the flow rate (A), the composition of the mobile phase (B), and the pH (C). The retention time (Y1 and Y3) and the peak area (Y2 and Y4) were taken as the response parameters. We observed that slight alterations in the mobile phase and the flow rate influenced the outcome, whereas the pH exerted no effect. Method validation featured various ICH parameters including linearity, limit of detection (LOD), accuracy, precision, ruggedness, robustness, stability, and system suitability. This method is potentially useful for the analysis of commercial formulations and laboratory preparations.


2010 ◽  
Vol 7 (3) ◽  
pp. 807-812 ◽  
Author(s):  
Vanita Somasekhar ◽  
D. Gowri Sankar

A reverse phase HPLC method is described for the determination of esmolol hydrochloride in bulk and injections. Chromatography was carried on a C18column using a mixture of acetonitrile, 0.05 M sodium acetate buffer and glacial acetic acid (35:65:3 v/v/v) as the mobile phase at a flow rate of 1 mL/min with detection at 275 nm. The retention time of the drug was 4.76 min. The detector response was linear in the concentration of 1-50 μg/mL. The limit of detection and limit of quantification was 0.614 and 1.86 μg/mL respectively. The method was validated by determining its sensitivity, linearity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of esmolol hydrochloride in bulk and injections.


Author(s):  
Muhammad Fawad Rasool ◽  
Umbreen Fatima Qureshi ◽  
Nazar Muhammad Ranjha ◽  
Imran Imran ◽  
Mouqadus Un Nisa ◽  
...  

AbstractTh accurate rapid, simple and selective reversed phase high performance liquid chromatography (RP-HPLC) has been established and validated for the determination of captopril (CAP). Chromatographic separation was accomplished using prepacked ODSI C18 column (250 mm × 4.6 mm with 5 μm particle size) in isocratic mode, with mobile phase consisting of water: acetonitrile (60:40 v/v), pH adjusted to 2.5 by using 85% orthophosphoric acid at a flow rate of 1 mL/min and UV detection was performed at 203 nm. RP-HPLC method used for the analysis of CAP in mobile phase and rabbit plasma was established and validated as per ICH-guidelines. It was carried out on a well-defined chromatographic peak of CAP was established with a retention time of 4.9 min and tailing factor of 1.871. The liquid–liquid extraction method was used for extraction of CAP from the plasma. Excellent linearity (R2 = 0.999) was shown over range 3.125–100 µg/mL with mean percentage recoveries ranges from 97 to 100.6%. Parameters of precision and accuracy of the developed method meet the established criteria. Intra and inter-day precision (% relative standard deviation) study was also performed which was less than 2% which indicate good reproducibility of the method. The limit of detection (LOD) and quantification for the CAP in plasma were 3.10 and 9.13 ng/mL respectively. The method was suitably validated and successfully applied to the determination of CAP in rabbit plasma samples.