An Improved Electrical Submersible Pump Performance Testing System

Author(s):  
Ariful I. Bhuiyan ◽  
Stewart Reed ◽  
Barnabas Nemec ◽  
Dale Henson
Author(s):  
Thuy Chu ◽  
Tan C. Nguyen ◽  
Jihoon Wang ◽  
Duc Vuong

AbstractElectrical Submersible Pump (ESP) is one of the major Artificial Lift methods that is reliable and effective for pumping high volume of fluids from wellbores. However, ESP is not recommended for applications with high gas liquid ratio. The presence of free gas inside the pump causes pump performance degradation which may lead to problems or even failure during operations. Thus, it is important to investigate effect of free gas on ESP performance under downhole conditions. At present, existing models or correlations are based on/verified with experimental data. This study is one of the first attempts to develop correlations for predicting two-phase gas–liquid pump performance under downhole conditions by using field data and laboratory data. Field data from three oil producing wells provided by Strata Production Company and Perdure Petroleum LLC. as well as experimental data obtained from experimental facility at Production and Drilling Research Project—New Mexico Tech were used in this study. Actual two-phase pump differential pressure per stage is obtained from experiments or estimated from field data and was normalized using pump performance curve. The values are compared to pump performance curve to study the relationships between pump performance and free gas percentage at pump intake. Correlations to predict ESP performance in two-phase flow under downhole and experimental conditions was derived from the results using regression technique. The correlation developed from field data presented in this study can be used to predict two-phase ESP performance under downhole conditions and under high gas fraction. The results from the experimental data confirm the reliability of the developed correlation using field data to predict two-phase ESP performance under downhole conditions. The developed correlation using the laboratory data predicts quite well the two-phase pump performance at the gas fraction of less than 15% while it is no longer reliable when free gas fraction is more than 15%. The findings from this study will help operating companies as well as ESP manufacturers to operate ESPs within the recommended range under downhole conditions. However, it is recommended to use the proposed correlation on reservoirs with conditions similar to those of the three presented wells.


Author(s):  
Yang Yang ◽  
Ling Zhou ◽  
Weidong Shi ◽  
Chuan Wang ◽  
Wei Li ◽  
...  

Abstract High speed rotating pump is the current trend in pump’s development and application, which has the advantages of compact size and energy-saving features. The electrical submersible pump, typically called an ESP, is an efficient and reliable artificial-lift method for lifting moderate to high volumes of fluids from wellbores, which have been wildly used for oil or groundwater extraction. To verify the similarity of pump performance under different rotating speeds, a typical ESP is selected as the model pump. By employing the numerical simulation and performance testing methods, the external performance characteristics and internal flow fields under different rotating speeds of the pump are studied. The entire computational domain is established by two stages ESP, and then meshed with the high-quality structured grid based on the Q-type and Y-type block topology. Grid sensitivity analysis is carried out to determine the appropriate mesh density for mesh independent solution. SST k-ω turbulence model with standard wall function in conjunction with Reynolds-Averaged Navier-Stokes (RANS) equations is used to solve the steady flow field. The results show that the increase in the rotating speed could increase the ESP’s head significantly. ESP’s external characteristics under different speeds meet the similar conversion rule quite well. In addition, the flow field distributions in the main flow components of the pump have great similarity at different rotating speeds. The experimental test results for a prototype show good agreement with the simulation results, including the pump’s head, efficiency and axial force. This paper provides a data set for further understanding of the effects of rotating speeds on ESP’s performance and inner flow fields.


Author(s):  
Gerald Morrison ◽  
Wenjie Yin ◽  
Rahul Agarwal ◽  
Abhay Patil

Understanding and predicting the effect of viscosity change on an Electrical Submersible Pump (ESP) performance is of great significance to the oil and gas operators. The purpose of this research is to investigate the flow behavior inside a mixed flow type pump operating with fluids of different viscosities using Computational Fluid Dynamics (CFD) with the goal to establish additional terms for the pump affinity laws to scale pump performance including the effects of viscosity. Several sets of fluids of different viscosities and densities are simulated under various operating conditions. The effect of viscosity on the performance of the impeller and diffuser is discussed. Changes in the pump performance due to fluid viscosity are characterized using the dimensionless flow coefficient, head coefficient and rotational Reynolds number. The result, which can be regarded as the modified pump affinity laws for viscosity flows, was obtained based on the relationships between dimensionless coefficients. The modified affinity laws agreed well with the CFD results. Further study was conducted to validate the relationships using previously published test data for a semi axial pump design (Specific Speed, Ns: 3869) tested with fluid viscosity ranging from 1 cp to 1020 cp and in-house testing of a split vane impeller pump (Ns: 3027) and a helicoaxial pump (Ns: 5281) using 1cp and 5 cp viscosity fluid. The modified affinity laws accurately models the performance dependence upon viscosity. As with the standard affinity laws, a pump’s functional relationship varies with each pump design. Yet the modified affinity laws produce a single common curve for all operating conditions and viscosities for a specific pump.


2011 ◽  
Vol 317-319 ◽  
pp. 1478-1481
Author(s):  
Li Sun ◽  
Zhao Qin Yin ◽  
Xiao Yang Yu ◽  
Guang Wen Zou

Multi-circuit gear pump working performance cannot be affected by load, and it outputs the same amount of oil in every port, which can provide static pressure supporting for the guide ways of machine tool. The test schematic is designed with the destination of testing multi-circuit gear pump hydraulic performance. Test equipment and hydraulic oil are selected scientifically and reasonably based on multi-circuit gear pump performance parameters which have been designed, and then hydraulic system is installed in order to execute performance testing.


2019 ◽  
Vol 10 ◽  
pp. 82-86
Author(s):  
A.N. Ivanov ◽  
◽  
V.A. Bondarenko ◽  
M.M. Veliev ◽  
E.V. Kudin ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document