scholarly journals Measurement properties of the Musculoskeletal Health Questionnaire (MSK-HQ): a between country comparison

2020 ◽  
Author(s):  
David Høyrup Christiansen ◽  
Gareth McCray ◽  
Trine Nøhr Winding ◽  
Johan Hviid Andersen ◽  
Kent Jacob Nielsen ◽  
...  

Abstract Background: The Musculoskeletal Health Questionnaire (MSK-HQ) has been developed to measure musculoskeletal health status across musculoskeletal conditions and settings. However, the MSK-HQ needs to be further evaluated across settings and different languages.Objective: The objective of the study was to evaluate and compare measurement properties of the MSK-HQ across Danish (DK) and English (UK) cohorts of patients from primary care physiotherapy services with musculoskeletal pain. Methods: MSK-HQ was translated into Danish according to international guidelines. Measurement invariance was assessed by differential item functioning (DIF) analyses. Test-retest reliability, measurement error, responsiveness and minimal clinically important change (MCIC) were evaluated and compared between DK (n=153) and UK (n=166) cohorts. Results: The Danish version demonstrated acceptable face and construct validity. Out of the 14 MSK-HQ items, three items showed DIF for language (pain/stiffness at night, understanding condition and confidence in managing symptoms) and three items showed DIF for pain location (walking, washing/dressing and physical activity levels). Intraclass Correlation Coefficients for test-retest were 0.86 (95% CI 0.81 to 0.91) for DK cohort and 0.77 (95% CI 0.49 to 0.90) for the UK cohort. The systematic measurement error was 1.6 and 3.9 points for the DK and UK cohorts respectively, with random measurement error being 8.6 and 9.9 points. Receiver operating characteristic (ROC) curves of the change scores against patients’ own judgment at 3 months exceeded 0.70 in both cohorts. Absolute and relative MCIC estimates were 8-10 points and 26% for the DK cohort and 6-8 points and 29% for the UK cohort.Conclusions: The measurement properties of MSK-HQ were acceptable across countries, but seem more suited for group than individual level evaluation. Researchers and clinicians should be aware that some discrepancy exits and should take the observed measurement error into account when evaluating change in scores over time.

2019 ◽  
Author(s):  
David Høyrup Christiansen ◽  
Gareth McCray ◽  
Trine Nøhr Winding ◽  
Johan Hviid Andersen ◽  
Kent Jacob Nielsen ◽  
...  

Abstract Background The Musculoskeletal Health Questionnaire (MSK-HQ) has been developed to measure musculoskeletal health status across musculoskeletal conditions and settings. However, the MSK-HQ needs to be further evaluated across settings and different languages. Objective The objective of the study was to evaluate and compare measurement properties of the MSK-HQ across Danish (DK) and English (UK) cohorts of patients from primary care physiotherapy services with musculoskeletal pain. Methods MSK-HQ was translated into Danish according to international guidelines. Measurement invariance was assessed by differential item functioning (DIF) analyses. Test-retest reliability, measurement error, responsiveness and minimal clinically important change (MCIC) were evaluated and compared between DK (n=153) and UK (n=166) cohorts. Results The Danish version demonstrated acceptable face and construct validity. Out of the 14 MSK-HQ items, three items showed DIF for language (pain/stiffness at night, understanding condition and confidence in managing symptoms) and three items showed DIF for pain location (walking, washing/dressing and physical activity levels). Intraclass Correlation Coefficients for test-retest were 0.86 (95% CI 0.81 to 0.91) for DK cohort and 0.77 (95% CI 0.49 to 0.90) for the UK cohort. The systematic measurement error was 1.6 and 3.9 points for the DK and UK cohorts respectively, with random measurement error being 8.6 and 9.9 points. Receiver operating characteristic (ROC) curves of the change scores against patients’ own judgment at 3 months exceeded 0.70 in both cohorts. Absolute and relative MCIC estimates were 8-10 points and 26% for the DK cohort and 6-8 points and 29% for the UK cohort. Conclusions The measurement properties of MSK-HQ were acceptable across countries, but seem more suited for group than individual level evaluation. Researchers and clinicians should be aware that some discrepancy exits and should take the observed measurement error into account when evaluating change in scores over time.


2020 ◽  
Author(s):  
David Høyrup Christiansen ◽  
Gareth McCray ◽  
Trine Nøhr Winding ◽  
Johan Hviid Andersen ◽  
Kent Jacob Nielsen ◽  
...  

Abstract Background: The Musculoskeletal Health Questionnaire (MSK-HQ) has been developed to measure musculoskeletal health status across musculoskeletal conditions and settings. However, the MSK-HQ needs to be further evaluated across settings and different languages.Objective: The objective of the study was to evaluate and compare measurement properties of the MSK-HQ across Danish (DK) and English (UK) cohorts of patients from primary care physiotherapy services with musculoskeletal pain. Methods: MSK-HQ was translated into Danish according to international guidelines. Measurement invariance was assessed by differential item functioning (DIF) analyses. Test-retest reliability, measurement error, responsiveness and minimal clinically important change (MCIC) were evaluated and compared between DK (n=153) and UK (n=166) cohorts. Results: The Danish version demonstrated acceptable face and construct validity. Out of the 14 MSK-HQ items, three items showed DIF for language (pain/stiffness at night, understanding condition and confidence in managing symptoms) and three items showed DIF for pain location (walking, washing/dressing and physical activity levels). Intraclass Correlation Coefficients for test-retest were 0.86 (95% CI 0.81 to 0.91) for DK cohort and 0.77 (95% CI 0.49 to 0.90) for the UK cohort. The systematic measurement error was 1.6 and 3.9 points for the DK and UK cohorts respectively, with random measurement error being 8.6 and 9.9 points. Receiver operating characteristic (ROC) curves of the change scores against patients’ own judgment at 3 months exceeded 0.70 in both cohorts. Absolute and relative MCIC estimates were 8-10 points and 26% for the DK cohort and 6-8 points and 29% for the UK cohort.Conclusions: The measurement properties of MSK-HQ were acceptable across countries, but seem more suited for group than individual level evaluation. Researchers and clinicians should be aware that some discrepancy exits and should take the observed measurement error into account when evaluating change in scores over time.


2019 ◽  
Author(s):  
David Høyrup Christiansen ◽  
Gareth McCray ◽  
Trine Nøhr Winding ◽  
Johan Hviid Andersen ◽  
Kent Jacob Nielsen ◽  
...  

Abstract Background The Musculoskeletal Health Questionnaire (MSK-HQ) has been developed to measure musculoskeletal health status across musculoskeletal conditions and settings. However, the MSK-HQ needs to be further evaluated across settings and different languages. Objective The objective of the study was to evaluate and compare measurement properties of the MSK-HQ across Danish (DK) and English (UK) cohorts of patients from primary care physiotherapy services with musculoskeletal pain. Methods MSK-HQ was translated into Danish according to international guidelines. Measurement invariance was assessed by differential item functioning (DIF) analyses. Test-retest reliability, measurement error, responsiveness and minimal clinically important change (MCIC) were evaluated and compared between DK (n=153) and UK (n=166) cohorts. Results The Danish version demonstrated acceptable face and construct validity. Out of the 14 MSK-HQ items, three items showed DIF for language (pain/stiffness at night, understanding condition and confidence in managing symptoms) and three items showed DIF for pain location (walking, washing/dressing and physical activity levels). Intraclass Correlation Coefficients for test-retest were 0.86 (95% CI 0.81 to 0.91) for DK cohort and 0.77 (95% CI 0.49 to 0.90) for the UK cohort. The systematic measurement error was 1.6 and 3.9 points for the DK and UK cohorts respectively, with random measurement error being 8.6 and 9.9 points. Receiver operating characteristic (ROC) curves of the change scores against patients’ own judgment at 3 months exceeded 0.70 in both cohorts. Absolute and relative MCIC estimates were 8-10 points and 26% for the DK cohort and 6-8 points and 29% for the UK cohort. Conclusions The measurement properties of MSK-HQ were acceptable across countries, but seem more suited for group than individual level evaluation. Researchers and clinicians should be aware that some discrepancy exits and should take the observed measurement error into account when evaluating change in scores over time.


Author(s):  
Jens Sörensen ◽  
Jonny Nordström ◽  
Tomasz Baron ◽  
Stellan Mörner ◽  
Sven-Olof Granstam ◽  
...  

Abstract Aim To develop a method for diagnosing left ventricular (LV) hypertrophy from cardiac perfusion 15O-water positron emission tomography (PET). Methods We retrospectively pooled data from 139 subjects in four research cohorts. LV remodeling patterns ranged from normal to severe eccentric and concentric hypertrophy. 15O-water PET scans (n = 197) were performed with three different PET devices. A low-end scanner (66 scans) was used for method development, and remaining scans with newer devices for a blinded evaluation. Dynamic data were converted into parametric images of perfusable tissue fraction for semi-automatic delineation of the LV wall and calculation of LV mass (LVM) and septal wall thickness (WT). LVM and WT from PET were compared to cardiac magnetic resonance (CMR, n = 47) and WT to 2D-echocardiography (2DE, n = 36). PET accuracy was tested using linear regression, Bland–Altman plots, and ROC curves. Observer reproducibility were evaluated using intraclass correlation coefficients. Results High correlations were found in the blinded analyses (r ≥ 0.87, P < 0.0001 for all). AUC for detecting increased LVM and WT (> 12 mm and > 15 mm) was ≥ 0.95 (P < 0.0001 for all). Reproducibility was excellent (ICC ≥ 0.93, P < 0.0001). Conclusion 15O-water PET might detect LV hypertrophy with high accuracy and precision.


2021 ◽  
pp. 105566562110403
Author(s):  
Todd C. Edwards ◽  
Carrie L. Heike ◽  
Kathleen A. Kapp-Simon ◽  
Salene M. Jones ◽  
Brian G. Leroux ◽  
...  

Objective We evaluated the measurement properties for item and domain scores of the Infant with Clefts Observation Outcomes Instrument (iCOO). Design Cross-sectional (before lip surgery) and longitudinal study (preoperative baseline and 2 days and 2 months after lip surgery). Setting Three academic craniofacial centers and national online advertisements. Participants Primary caregivers with an infant with cleft lip with or without cleft palate (CL  ±  P) scheduled to undergo primary lip repair. There were 133 primary caregivers at baseline, 115 at 2 days postsurgery, and 112 at 2 months postsurgery. Main Outcome Measure(s) Caregiver observation items ( n = 61) and global impression of health and function items ( n = 8) across eight health domains. Results Mean age at surgery was 6.0 months (range 2.7-11.8 months). Five of eight iCOO domains have scale scores, with Cronbach’s alphas ranging from 0.67 to 0.87. Except for the Facial Skin and Mouth domain, iCOO scales had acceptable intraclass correlation coefficients (ICCs) ranging from 0.76 to 0.84. The internal consistency of the Global Impression items across all domains was 0.90 and had acceptable ICCs (range 0.76-0.91). Sixteen out of 20 (nonscale) items had acceptable ICCs (range 0.66-0.96). As anticipated, iCOO scores 2 days postoperatively were generally lower than baseline and scores 2 months postsurgery were consistent with baseline or higher. The iCOO took approximately 10 min to complete. Conclusions The iCOO meets measurement standards and may be used for assessing the impact of cleft-related treatments in clinical research and care. More research is needed on its use in various treatment contexts.


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Hannah M. L. Young ◽  
Mark W. Orme ◽  
Yan Song ◽  
Maurice Dungey ◽  
James O. Burton ◽  
...  

Abstract Background Physical activity (PA) is exceptionally low amongst the haemodialysis (HD) population, and physical inactivity is a powerful predictor of mortality, making it a prime focus for intervention. Objective measurement of PA using accelerometers is increasing, but standard reporting guidelines essential to effectively evaluate, compare and synthesise the effects of PA interventions are lacking. This study aims to (i) determine the measurement and processing guidance required to ensure representative PA data amongst a diverse HD population, and; (ii) to assess adherence to PA monitor wear amongst HD patients. Methods Clinically stable HD patients from the UK and China wore a SenseWear Armband accelerometer for 7 days. Step count between days (HD, Weekday, Weekend) were compared using repeated measures ANCOVA. Intraclass correlation coefficients (ICCs) determined reliability (≥0.80 acceptable). Spearman-Brown prophecy formula, in conjunction with a priori ≥  80% sample size retention, identified the minimum number of days required for representative PA data. Results Seventy-seven patients (64% men, mean ± SD age 56 ± 14 years, median (interquartile range) time on HD 40 (19–72) months, 40% Chinese, 60% British) participated. Participants took fewer steps on HD days compared with non-HD weekdays and weekend days (3402 [95% CI 2665–4140], 4914 [95% CI 3940–5887], 4633 [95% CI 3558–5707] steps/day, respectively, p < 0.001). PA on HD days were less variable than non-HD days, (ICC 0.723–0.839 versus 0.559–0.611) with ≥ 1 HD day and ≥  3 non-HD days required to provide representative data. Using these criteria, the most stringent wear-time retaining ≥ 80% of the sample was ≥7 h. Conclusions At group level, a wear-time of ≥7 h on ≥1HD day and ≥ 3 non-HD days is required to provide reliable PA data whilst retaining an acceptable sample size. PA is low across both HD and non- HD days and future research should focus on interventions designed to increase physical activity in both the intra and interdialytic period.


2020 ◽  
Vol 18 (1) ◽  
Author(s):  
David Høyrup Christiansen ◽  
Gareth McCray ◽  
Trine Nøhr Winding ◽  
Johan Hviid Andersen ◽  
Kent Jacob Nielsen ◽  
...  

2020 ◽  
Vol 23 (18) ◽  
pp. 3295-3303
Author(s):  
Yiyang Yue ◽  
Joshua Petimar ◽  
Walter C Willett ◽  
Stephanie A Smith-Warner ◽  
Changzheng Yuan ◽  
...  

AbstractObjective:To evaluate the validity and reproducibility of a 152-item semi-quantitative FFQ (SFFQ) for estimating flavonoid intakes.Design:Over a 1-year period, participants completed two SFFQ and two weighed 7-d dietary records (7DDR). Flavonoid intakes from the SFFQ were estimated separately using Harvard (SFFQHarvard) and Phenol-Explorer (SFFQPE) food composition databases. 7DDR flavonoid intakes were derived using the Phenol-Explorer database (7DDRPE). Validity was assessed using Spearman’s rank correlation coefficients deattenuated for random measurement error (rs), and reproducibility was assessed using rank intraclass correlation coefficients.Setting:This validation study included primarily participants from two large observational cohort studies.Participants:Six hundred forty-one men and 724 women.Results:When compared with two 7DDRPE, the validity of total flavonoid intake assessed by SFFQPE was high for both men and women (rs = 0·77 and rs = 0·74, respectively). The rs for flavonoid subclasses ranged from 0·47 for flavones to 0·78 for anthocyanins in men and from 0·46 for flavonols to 0·77 for anthocyanins in women. We observed similarly moderate (0·4–0·7) to high (≥0·7) validity when using SFFQHarvard estimates, except for flavonesHarvard (rs = 0·25 for men and rs = 0·19 for women). The SFFQ demonstrated high reproducibility for total flavonoid and flavonoid subclass intake estimates when using either food composition database. The intraclass correlation coefficients ranged from 0·69 (flavonolsPE) to 0·80 (proanthocyanidinsPE) in men and from 0·67 (flavonolsPE) to 0·77 (flavan-3-ol monomersHarvard) in women.Conclusions:SFFQ-derived intakes of total flavonoids and flavonoid subclasses (except for flavones) are valid and reproducible for both men and women.


2010 ◽  
Vol 7 (6) ◽  
pp. 697-705 ◽  
Author(s):  
Dori E. Rosenberg ◽  
Gregory J. Norman ◽  
Nicole Wagner ◽  
Kevin Patrick ◽  
Karen J. Calfas ◽  
...  

Background:Sedentary behavior is related to obesity, but measures of sedentary behaviors are lacking for adults. The purpose of this study was to examine the reliability and validity of the Sedentary Behavior Questionnaire (SBQ) among overweight adults.Methods:Participants were 49 adults for the 2 week test-retest reliability study (67% female, 53% white, mean age = 20) and 401 overweight women (mean age = 41, 61% white) and 441 overweight men (mean age = 44, 81% white) for the validity study. The SBQ consisted of reports of time spent in 9 sedentary behaviors. Outcomes for validity included accelerometer measured inactivity, sitting time (International Physical Activity Questionnaire), and BMI. Intraclass correlation coefficients (ICCs) assessed reliability and partial correlations assessed validity.Results:ICCs were acceptable for all items and the total scale (range = .51–.93). For men, there were significant relationships of SBQ items with IPAQ sitting time and BMI. For women, there were relationships between the SBQ and accelerometer inactivity minutes, IPAQ sitting time, and BMI.Conclusions:The SBQ has acceptable measurement properties for use among overweight adults. Specific measures of sedentary behavior should be included in studies and population surveillance.


Author(s):  
Jin Luo ◽  
Raymond Y. W. Lee

AbstractPhysical activity brings significant health benefits to middle-aged adults, although the research to date has been focused on late adulthood. This study aims to examine how ageing affects the self-reported and accelerometer-derived measures of physical activity levels in middle-aged adults. We employed the data recorded in the UK Biobank and analysed the physical activity levels of 2,998 participants (1381 men and 1617 women), based on self-completion questionnaire and accelerometry measurement of physical activity. We also assessed the musculoskeletal health of the participants using the dual-energy X-ray absorptiometry (DXA) measurements provided by the UK Biobank. Participants were categorised into three groups according to their age: group I younger middle-aged (40 to 49 years), group II older middle-aged (50 to 59 years), and group III oldest middle-aged (60 to 69 years). Self-reported physical activity level increased with age and was the highest in group III, followed by group II and I (P < 0.05). On the contrary, physical activity measured by accelerometry decreased significantly with age from group I to III (P < 0.05), and the same pertained to the measurements of musculoskeletal health (P < 0.05). It was also shown that middle-aged adults mostly engaged in low and moderate intensity activities. The opposing trends of the self-reported and measured physical activity levels may suggest that middle-aged adults over-report their activity level as they age. They should be aware of the difference between their perceived and actual physical activity levels, and objective measures would be useful to prevent the decline in musculoskeletal health.


Sign in / Sign up

Export Citation Format

Share Document