scholarly journals Influence of Sagittal Root Positions on the Stress Distribution Around Custom-made Root-analogue Implants: A Three-dimensional Finite Element Analysis

Author(s):  
Chunping Lin ◽  
Hongcheng Hu ◽  
Junxin Zhu ◽  
Yuwei Wu ◽  
Qiguo Rong ◽  
...  

Abstract Background: Stress concentration may cause bone resorption even lead to the failure of implantation. This study was designed to investigate whether a certain sagittal root position could cause stress concentration around maxillary anterior custom-made root-analogue implants via three-dimensional finite element analysis.Methods: Six models were constructed and divided into two groups. The smooth group included models of unthreaded custom-made implants in Class I, II or III sagittal root positions. The threaded group included models of reverse buttress-threaded implants in the three positions. Stress distributions under vertical and oblique loads of 100 N were analyzed.Results: Stress concentrations around the labial lamella area were more prominent in the Class I position than in the Class II and Class III positions under oblique loading. Under vertical loading, the most obvious stress concentration areas were the labial lamella and palatal apical areas in the Class I and Class III positions, respectively. Stress was relatively distributed in the labial and palatal lamellae in the Class II position. The maximum von Mises stress in the bone around the custom-made root-analogue implants in this study was lower than around traditional implants reported in the literature. Additionally, compared to the smooth group, the threaded group showed lower von Mises stress in the bone around the implants.Conclusions: The sagittal root position affected the von Mises stress distribution around custom-made root-analogue implants. There was no certain sagittal root position that could cause excessive stress concentration around the custom-made root-analogue implants. Among the three sagittal root positions, the Class II position would be the most appropriate site for custom-made root-analogue implants.

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Chunping Lin ◽  
Hongcheng Hu ◽  
Junxin Zhu ◽  
Yuwei Wu ◽  
Qiguo Rong ◽  
...  

Abstract Background Stress concentration may cause bone resorption even lead to the failure of implantation. This study was designed to investigate whether a certain sagittal root position could cause stress concentration around maxillary anterior custom-made root-analogue implants via three-dimensional finite element analysis. Methods The von Mises stresses in the bone around implants in different groups were compared by finite element analysis. Six models were constructed and divided into two groups through Geomagic Studio 2012 software. The smooth group included models of unthreaded custom-made implants in Class I, II or III sagittal root positions. The threaded group included models of reverse buttress-threaded implants in the three positions. The von Mises stress distributions and the range of the stresses under vertical and oblique loads of 100 N were analyzed through ANSYS 16.0 software. Results Stress concentrations around the labial lamella area were more prominent in the Class I position than in the Class II and Class III positions under oblique loading. Under vertical loading, the most obvious stress concentration areas were the labial lamella and palatal apical areas in the Class I and Class III positions, respectively. Stress was relatively distributed in the labial and palatal lamellae in the Class II position. The maximum von Mises stresses in the bone around the custom-made root-analogue implants in this study were lower than around traditional implants reported in the literature. The maximum von Mises stresses in this study were all less than 25 MPa in cortical bone and less than 6 MPa in cancellous bone. Additionally, compared to the smooth group, the threaded group showed lower von Mises stress concentration in the bone around the implants. Conclusions The sagittal root position affected the von Mises stress distribution around custom-made root-analogue implants. There was no certain sagittal root position that could cause excessive stress concentration around the custom-made root-analogue implants. Among the three sagittal root positions, the Class II position would be the most appropriate site for custom-made root-analogue implants.


Author(s):  
Nurullah Türker ◽  
Hümeyra Tercanlı Alkış ◽  
Steven J Sadowsky ◽  
Ulviye Şebnem Büyükkaplan

An ideal occlusal scheme plays an important role in a good prognosis of All-on-Four applications, as it does for other implant therapies, due to the potential impact of occlusal loads on implant prosthetic components. The aim of the present three-dimensional (3D) finite element analysis (FEA) study was to investigate the stresses on abutments, screws and prostheses that are generated by occlusal loads via different occlusal schemes in the All-on-Four concept. Three-dimensional models of the maxilla, mandible, implants, implant substructures and prostheses were designed according to the All-on-Four concept. Forces were applied from the occlusal contact points formed in maximum intercuspation and eccentric movements in canine guidance occlusion (CGO), group function occlusion (GFO) and lingualized occlusion (LO). The von Mises stress values for abutment and screws and deformation values for prostheses were obtained and results were evaluated comparatively. It was observed that the stresses on screws and abutments were more evenly distributed in GFO. Maximum deformation values for prosthesis were observed in the CFO model for lateral movement both in the maxilla and mandible. Within the limits of the present study, GFO may be suggested to reduce stresses on screws, abutments and prostheses in the All-on-Four concept.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Charles Savoldelli ◽  
Elodie Ehrmann ◽  
Yannick Tillier

AbstractWith modern-day technical advances, high sagittal oblique osteotomy (HSOO) of the mandible was recently described as an alternative to bilateral sagittal split osteotomy for the correction of mandibular skeletal deformities. However, neither in vitro nor numerical biomechanical assessments have evaluated the performance of fixation methods in HSOO. The aim of this study was to compare the biomechanical characteristics and stress distribution in bone and osteosynthesis fixations when using different designs and placing configurations, in order to determine a favourable plating method. We established two finite element models of HSOO with advancement (T1) and set-back (T2) movements of the mandible. Six different configurations of fixation of the ramus, progressively loaded by a constant force, were assessed for each model. The von Mises stress distribution in fixations and in bone, and bony segment displacement, were analysed. The lowest mechanical stresses and minimal gradient of displacement between the proximal and distal bony segments were detected in the combined one-third anterior- and posterior-positioned double mini-plate T1 and T2 models. This suggests that the appropriate method to correct mandibular deformities in HSOO surgery is with use of double mini-plates positioned in the anterior one-third and posterior one-third between the bony segments of the ramus.


Author(s):  
Les Kalman ◽  
Amanda Maria de Oliveira Dal Piva ◽  
Talita Suelen de Queiroz ◽  
João Paulo Mendes Tribst

Orofacial injuries are common occurrences during contact sports activities; however, there is an absence of data regarding the performance of hybrid occlusal splint mouthguards, especially during compressive loading. To evaluate the total deformation and stress concentration, a skull model was selected and duplicated to receive two different designs of mouthguard devices: one model received a conventional custom-made mouthguard (MG) with 4-mm thickness and the other received a novel hybrid occlusal splint-mouthguard (HMG) with the same thickness. Both models were subdivided into finite elements. The frictionless contacts were used, and a nonlinear analysis was performed simulating the compressive loading in occlusion. The results were presented in von-Mises stress maps (MPa) and Total Deformation (mm). A higher stress concentration in teeth was observed for the model with the conventional MG, while the HMG design displayed a promising mechanical response with lower stress magnitude. The HMG de-sign displayed a higher magnitude of stress on its occlusal portion than the MG design. The hybrid mouthguard (HMG) reduced (1) jaw displacement during chewing and (2) the generated stresses in maxil-lary and mandibular teeth.


2018 ◽  
Vol 141 (3) ◽  
Author(s):  
Huaidong Yang ◽  
Itzhak Green

This work employs a three-dimensional (3D) finite element analysis (FEA) to investigate the fretting metallic contact between a deformable hemisphere and a deformable flat block. Fretting is governed by displacement-controlled action where the materials of the two contacting bodies are set to have identical properties; studied first is steel-on-steel and then copper-on-copper. At contact onset, a normal interference (indentation) is applied, which is then followed by transverse cyclic oscillations. A large range of coefficients of friction (COFs) is imposed at the interface. The results show that the maximum von Mises stress is confined under the contacting surface for small COFs; however, that maximum reaches the contacting surface when the COFs are sufficiently large. It is also shown that fretting under sufficiently large COFs forms large plastic strains in “ring” like patterns at the contacting surfaces. Junction growth is found where the contacting region is being stretched in the direction of the fretting motion. At large COFs, pileups show up at the edges of the contact. The fretting loops of the initial cycles are found along with the total work invested into the system. At certain interference, there exists a certain COF, which results in the largest work consumption. The magnitude of the COF is found to produce either partial slip (prone for fretting fatigue) or gross slip (prone for fretting wear). A scheme of normalization is proposed, and it is shown to be effective for the two said materials that have vastly different material properties. Hence, the normalized results may well characterize a range of contact scales (from micro to macro) of various ductile material pairs that behave in an elastic–plastic manner with strain hardening.


2020 ◽  
Vol 28 (6) ◽  
pp. 603-613 ◽  
Author(s):  
Efe Can Sivrikaya ◽  
Mehmet Sami Guler ◽  
Muhammed Latif Bekci

BACKGROUND: Zirconia has become a popular biomaterial in dental implant systems because of its biocompatible and aesthetic properties. However, this material is more fragile than titanium so its use is limited. OBJECTIVES: The aim of this study was to compare the stresses on morse taper implant systems under parafunctional loading in different abutment materials using three-dimensional finite element analysis (3D FEA). METHODS: Four different variations were modelled. The models were created according to abutment materials (zirconia or titanium) and loading (1000 MPa vertical or oblique on abutments). The placement of the implants (diameter, 5.0 × 15 mm) were mandibular right first molar. RESULTS: In zirconia abutment models, von Mises stress (VMS) values of implants and abutments were decreased. Maximum and minimum principal stresses and VMS values increased in oblique loading. VMS values were highest in the connection level of the conical abutments in all models. CONCLUSIONS: Using conical zirconia abutments decreases von Mises stress values in abutments and implants. However, these values may exceed the pathological limits in bruxism patients. Therefore, microfractures may be related to the level of the abutment.


2013 ◽  
Vol 07 (04) ◽  
pp. 484-491 ◽  
Author(s):  
Wagner Moreira ◽  
Caio Hermann ◽  
Jucélio Tomás Pereira ◽  
Jean Anacleto Balbinoti ◽  
Rodrigo Tiossi

ABSTRACT Objective: The purpose of this study was to evaluate the mechanical behavior of two different straight prosthetic abutments (one- and two-piece) for external hex butt-joint connection implants using three-dimensional finite element analysis (3D-FEA). Materials and Methods: Two 3D-FEA models were designed, one for the two-piece prosthetic abutment (2 mm in height, two-piece mini-conical abutment, Neodent) and another one for the one-piece abutment (2 mm in height, Slim Fit one-piece mini-conical abutment, Neodent), with their corresponding screws and implants (Titamax Ti, 3.75 diameter by 13 mm in length, Neodent). The model simulated the single restoration of a lower premolar using data from a computerized tomography of a mandible. The preload (20 N) after torque application for installation of the abutment and an occlusal loading were simulated. The occlusal load was simulated using average physiological bite force and direction (114.6 N in the axial direction, 17.1 N in the lingual direction and 23.4 N toward the mesial at an angle of 75° to the occlusal plan). Results: The regions with the highest von Mises stress results were at the bottom of the initial two threads of both prosthetic abutments that were tested. The one-piece prosthetic abutment presented a more homogeneous behavior of stress distribution when compared with the two-piece abutment. Conclusions: Under the simulated chewing loads, the von Mises stresses for both tested prosthetic-abutments were within the tensile strength values of the materials analyzed which thus supports the clinical use of both prosthetic abutments.


2014 ◽  
Vol 607 ◽  
pp. 713-716
Author(s):  
Wen Liang Tang ◽  
Chun Yue Huang ◽  
Tian Ming Li ◽  
Ying Liang ◽  
Guo Ji Xiong ◽  
...  

In this paper, ANSYS-LSDYNA simulation software is used to build the three-dimensional finite element model of the ball bond and to get the Von Mises stress. The change of stress about the bump is researched which base on the model in different bonding pressure, bonding power and bonding time. The result show that: The stress increase with bonding pressure increase within a certain bonding pressure range, and then the stress will maintain a table number, however, the stress will continue to increase when the bonding pressure reach a certain value; increasing the bonding power, the area of lager stress will grow; prolonging the bonding time, the stress of the pad will increase with time, but when time increase to a certain value, the stress of the pad will not increase over time.


2020 ◽  
Vol 8 (1) ◽  
pp. 29-46
Author(s):  
S. Rakshe ◽  
S. V. Nimje ◽  
S. K. Panigrahi

A review on optimization of adhesively bonded spar-wingskin joint (SWJ) of laminated fiber reinforced polymer (FRP) composites subjected to pull-off load is presented in this article using three-dimensional finite element analysis. Von Mises stress components have been computed across the width of joint at different interfaces viz. load coupler-spar, and load coupler-wingskin interfaces. Further, the weight of SWJ structure is considered as the objective function which needs to be minimized for optimization. In the first step, the material and lamination scheme of the FRP composite materials used for SWJ are optimized, and, in the second step, the geometrical parameters have been optimized on the basis of minimum von Mises stress and weight. Further, the effects of the material, lamination scheme, and geometrical parameters on the von Mises stress and weight have been validated using the Analysis of Variance (ANOVA) approach as prescribed by the Taguchi method. The results show that the material and spar thickness are the most significant factors influencing von Mises stress. The weight analysis reveals that there is a significant effect of change in material and wingskin thickness on SWJ performance. Suitable design recommendations have been made for SWJ in terms of material, lamination scheme and geometrical parameters.


2005 ◽  
Vol 9 ◽  
pp. 109-116 ◽  
Author(s):  
J.B. Kim

The paper describes the combined influences of the forward sabot diameter, sabot modulus, and L/D on the stress of the projectile rod traveling in the gun tube. Three types of gun tube profile were simulated. The first profile is perfectly straight. The second profile is monotonously curved tube only by gravity loads (Type A). The third is a changeful curved tube by gravity loads with imagined as-manufactures (Type B). Three-dimensional dynamic finite element analysis method was used for the sabot/rod system transiting in a gun tube. Numerical simulation results showed that the maximum von Mises stress due to in-bore behavior of the sabot/rod system could be decreased by changing the forward sabot diameter in a type B tube. The effect of tube centerline profile on the stress of the rod was analyzed for the conditions mentioned above. The von Mises stress of the rod in the changeful curved tube is as much as 10% higher than that in the straight or monotonously curved tube.


Sign in / Sign up

Export Citation Format

Share Document