Design of Diagnostic Tools Heavy Equipment Valve Air Conditioning (HVAC) Based Microcontroller for Troubleshooting Air Conditioner on Machine Heavy Equipment

2021 ◽  
Author(s):  
ABD. HALIM ◽  
DARMA AVIVA ◽  
FAISAL BACKRIE ◽  
MANGKONA MANGKONA
2015 ◽  
Vol 9 (1) ◽  
pp. 135-140
Author(s):  
Dong Zhi-Ming ◽  
Guo Li-Xia ◽  
Chang Ji-Bin ◽  
Zhou Xue-Bin

Aiming to compare the cooling effect, two types of solar-powered semiconductor air-conditioning devices were designed in different structures. According to the cooling load in an experimental room, the solar panels and battery capacity were determined for the development of a test system. In the same working condition, a comparison test was carried out to examine the cooling performance. Experimental results showed that the design of dual water-cooled cooling unit presented a higher ratio of energy efficiency, with its maximum value of 1.08. By observing the experimental data of the prototype, its comparative economic evaluation results indicated that the annualized cost of solar semiconductor airconditioning was app. 2.7 times that of air-conditioning made from an ordinary compressor.


2021 ◽  
pp. 102585
Author(s):  
Kasni Sumeru ◽  
Mohamad Firdaus Sukri ◽  
Triaji Pangripto Pramudantoro ◽  
Eddy Erham ◽  
Rizki Muliawan

Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4663
Author(s):  
Tatsuhiro Yamamoto ◽  
Akihito Ozaki ◽  
Myonghyang Lee

The number of houses with large, continuous spaces has increased recently. With improvements in insulation performance, it has become possible to efficiently air condition such spaces using a single air conditioner. However, the air conditioning efficiency depends on the placement of the air conditioner. The only way to determine the optimal placement of such air conditioners is to conduct an experiment or use computational fluid dynamic analysis. However, because the analysis is performed over a limited period, it is difficult to consider non-stationarity effects without using an energy simulation. Therefore, in this study, energy simulations and computational fluid dynamics analyses were coupled to develop a thermal environment analysis method that considers non-stationarity effects, and various air conditioner arrangements were investigated to demonstrate the applicability of the proposed method. The accuracy verification results generally followed the experimental results. A case study was conducted using the calculated boundary conditions, and the results showed that the placement of two air conditioners in the target experimental house could provide sufficient air conditioning during both winter and summer. Our results suggest that this method can be used to conduct preliminary studies if the necessary data are available during design or if an experimental house is used.


2017 ◽  
Vol 140 (1) ◽  
Author(s):  
Carlos R. de Nardin ◽  
Felipe T. Fernandes ◽  
Adriano J. Longo ◽  
Luciano P. Lima ◽  
Felix A. Farret ◽  
...  

This paper presents a comparison of air conditioners using the conventional heating, ventilation, and air conditioning heat pumps and the one using solar heat stored underground, also known as shallow geothermal air conditioning. The proposed air conditioner with solar heat stored underground reunites practical data from an implementation of the heuristic perturb-and-observe (P&O) control and a heat management technique. The aim is to find out the best possible heat exchange between the room ambient and the underground soil heat to reduce its overall consumption without any heat pump. Comparative tests were conducted in two similar rooms, each one equipped with one of the two types of air conditioning. The room temperature with the conventional air conditioning was maintained as close as possible to the temperature of the test room with shallow geothermal conditioning to allow an acceptable data validation. The experiments made both in the winter of 2014 and in the summer of 2015 in Santa Maria, South Brazil, demonstrated that the conventional air conditioner consumed 19.08 kWh and the shallow geothermal conditioner (SGC) consumed only 4.65 kWh, therefore, representing a reduction of energy consumption of approximately 75%.


Author(s):  
I Nengah Ardita ◽  
◽  
I Gusti Agung Bagus Wirajati ◽  
I Dewa Made Susila ◽  
Sudirman Sudirman ◽  
...  

Split air conditioning (AC) is the most widely used in the community for both commercial and domestic utilities. At the present refrigerant which used in Split AC is mostly common group of HFCs, such as R410a. R410a is a zeotropic refrigerant and if there is a leak in the system, it cannot be added this refrigerant. This will increase the cost of maintenance. The aims of this research is to investigate the retrofit of R410a with R32 on the Split AC system. The R32 is chosen because it has higher latent evaporation heat at the same temperature and has less effect on global warming. The refrigeration effect, the power consumption and the system performance are the main three quantities that want to be examined in this research which are observed before and after retrofit. Experimental investigation conducted during this research, including design and manufacture of experimental equipment, calibration and tools installment, collecting the experimental data and analysis by quantitative description method before and after retrofit. The results informed that cooling effect increased during the research, but the COP system has a slight decrease about 4%. R32 refrigerant is quite feasible as a retrofit refrigerant to R410a refrigerant.


Author(s):  
Joseph Sekyi-Ansah ◽  
James Kwasi Quaisie ◽  
Isaac Eduyah ◽  
Mohammed Okoe Alhassan ◽  
Eric Quansah ◽  
...  

Air conditioning has become a key component in the automobile industry now, and almost every vehicle manufactured in the 21st century has air conditioning integrated. Most drivers drive with their air conditioning on while some of their windows are not fully closed; this affects the operation of the air conditioning. In addition, if the driver wants to turn on the air conditioning while driving, he or she has to move up the power windows manually after or before he or she turns on the air conditioning, which may affect his or her concentration on the road. The concept of this power window circuit system is to automatically close the windows after a few seconds when the air conditioner is turned on.


2020 ◽  
Vol 5 (1) ◽  
pp. 14
Author(s):  
Ghodbane Mokhtar

Air conditioning is one of the indispensable conditions of well-being in human life, so the face of this research to provide this basic necessity in remote areas and in desert places far from power grids. To achieve this goal, solar air conditioning has been adopted, where the compressor was replaced by an ejector, a parabolic trough solar collector and a small pump; this means that the solar air conditioner does not need a huge amount of electrical energy to operate. This paper is studding the thermodynamic cycles of this air conditioner as a function of changing the climatic conditions of Bouzaréah region in Algeria under several practical conditions of heat exchangers (Condenser, Evaporator and Generator). This study will allow the determination of the optical and thermal efficiency of the solar collector used as a solar thermal generator, refrigeration subsystem performance (COPEje) and system thermal ratio of the air conditioner, where the cooling load is estimated at 18 kW.


Author(s):  
S. N. Osipov ◽  
A. V. Zakharenko ◽  
E. M. Shirokova

The increase of average outdoor temperatures and their fluctuations over the past 20 years (as evidenced by the records of summer temperatures in our country) has significantly increased the need for air conditioning premises where people are present for a long time, especially when they are crowded (shops, entertainment halls, classrooms, etc.). The air conditioning process is quite energy-intensive, but the growth of well-being in many republics of the former USSR, as well as the increasing complexity of the physiological adaptation of the human body to rising outdoor temperatures make it possible (and at the same time necessary) to implement these systems on a large scale. It is important to take into account that electricity prices are currently maintained at a high level for homeowners, and in the coming years the prices will only grow. Therefore, the development of new ways of significant increase of the energy efficiency of the indoor air conditioning process is of a great interest. One of these methods is the use of laminar (or close to them) moving layers of conditioned air in a limited area of work or rest of people. Such a zone, about 1.0‒1.2 m height from a floor in each apartment is, e.g., living rooms (bedroom) in which standard temperature conditions are created by means of simple air supplying and air intake devices. In the case of sedentary work of people, the height of such a zone of conditioned air should be increased to 1.3‒1.5 m. It has already been established that the use of laminar (or close to them) air flows allows to reduce the power consumption by two or more times due to significantly reduced heat exchange with the surrounding heated surfaces. Besides, the simplicity of such systems ought to be noted. In particular, in conditions of modern systems of control and management of air conditioning, the "duties" of consumers include only the installation on the control device of the initial data relating directly to the required parameters of the microclimate. At the same time, it should be noted that there is currently no complete scientific and technical description of aerodynamic and heat exchange processes in the air conditioning zone. Even in modern conditions for countries with a sharply continental climate (Russia, Kazakhstan, etc.), the problem is the choice of the type of air conditioner for its effective use in hot periods of summer. In general, it can be noted that all the problems of energy-efficient use of air conditioners must find a comprehensive solution.


2021 ◽  
Vol 1021 ◽  
pp. 97-106
Author(s):  
Mustafa W. Hamdallah ◽  
Omar M. Jumaah ◽  
Zaid A. Shaalan ◽  
Adnan M. Hussein

The aims of this study are to improve thermal characteristics and decrease electrical consumption of air-conditioning as well as, to increase the performance (COP) of cooling cycle. CuO nanoparticles (0.003 mass fraction) have been added to compressor oil of air conditioning (1 ton capacity, split-unit) used Freon gas (R22), and then compared with pure oil compressor of air conditioning under same environmental conditions. The results showed that the increasing of density ratio, COP and viscosity ratio are 3%, 50% and 1.8% respectively while the decreasing of electrical consumption is 51.2%. The experimental data are compared with previous data in the literature to be validated. It can be recommended that the nano-oil is significant utilizing in air conditioner compressors for energy consumption applications.


Sign in / Sign up

Export Citation Format