Pollutant removal efficiency of a retrofitted stormwater detention pond

2013 ◽  
Vol 49 (2) ◽  
pp. 124-134 ◽  
Author(s):  
Jason Faber Carpenter ◽  
Bertrand Vallet ◽  
Geneviève Pelletier ◽  
Paul Lessard ◽  
Peter A. Vanrolleghem

The objectives of this study were to characterize the stormwater runoff for a residential catchment, evaluate the present detention pond removal efficiency for different pollutants, and evaluate how its efficiency can be increased by controlling the pond stormwater retention time. The analysed pollutants were total suspended solids (TSS), total metals and ammonia. Runoff pollutant concentrations were generally found to agree with literature for the small residential catchment. The design of the original pond was such that low retention times of most analysed pollutants occurred, causing a lower than expected removal efficiency when compared to similar types of ponds. The retrofitting of the pond consisted of adding a sluice gate at the outlet in order to retain stormwater for longer periods of time. The retrofit allowed drastic improvement of the removal efficiency for TSS, NH3-N and zinc, from 39 to 90%, 10 to 84%, and 20 to 42%, respectively.

2018 ◽  
Vol 1 (3) ◽  
Author(s):  
Nusa Idaman Said ◽  
Firly Firly

An experiment of anaerobic biofilter using honeycomb plastic media was conducted in semi-pilot scale. This paper describes the pilot plan study of chicken’s slaughterhouse wastewater treatment using anaerobic and aerobic submerged biofilter using honeycomb plastic media. The main research was conducting by continuous operation under condition 4 days, 2 days and 1 day retention time. The result of experiment shows that within the anaerobic process under conditions 1- 4 days retention time, the removal efficiency of COD were 78 – 87 %, BOD  were 78 – 89   %, 73 – 83 % , and Total Suspended Solids (TSS) were 83 – 96 %  respectively.  Using combined anaerobic and aerobic process under same conditions 1 - 4 days retention time shows increasing of removal efficiency.  The removal efficiency of COD were 86 – 90 %, BOD were 85 – 90 %, Organics (KMnO4) were 81 – 88 % and Total Suspended Solids (TSS) were 94 – 96 % respectively.  The longer retention time has resulted in higher removal efficiency. Kata Kunci : Biofilter anaerobik, media sarang tawon, air limbah, rumah potong ayam.


2019 ◽  
Vol 6 (1) ◽  
pp. 45-54 ◽  
Author(s):  
Veymar G. Tacias-Pascacio ◽  
Abumalé Cruz-Salomón ◽  
José H. Castañón-González ◽  
Beatriz Torrestiana-Sanchez

Background: Wet coffee processing consists of the removal of the pulp and mucilage of the coffee cherry. This process generates a large amount of acidic wastewater which is very aggressive to the environment because of its high content of recalcitrant organic matter. Therefore, treatment is necessary before discharge to water bodies. Because of this reason, this study aimed to evaluate the organic matter removal efficiency in an Anaerobic Baffled Bioreactor (ABR) coupled to a Microfiltration Membrane (MF) system as a new eco-friendly option in the treatment of wet Coffee Processing Wastewater (CPWW). Methods: Two systems (S1 and S2) were evaluated at Hydraulic Retention Times (HRT) of 59 h and 83 h, respectively. Both systems were operated at mesophilic conditions, at a Transmembrane Pressure (TMP) of 50 kPa during 1800 h. Results: The S2 generated higher organic matter removal efficiency, reaching removal values of turbidity of 98.7%, Chemical Oxygen Demand (COD) of 81%, Total Solids (TS) of 72.6%, Total Suspended Solids (TSS) of 100%, and Total Dissolved Solids (TDS) of 61%, compared with the S1. Conclusion: The S2 represents a new eco-friendly alternative to treat CPWW and reduce its pollutant effect.


Water ◽  
2018 ◽  
Vol 10 (10) ◽  
pp. 1445 ◽  
Author(s):  
Michał Marzec ◽  
Krzysztof Jóźwiakowski ◽  
Anna Dębska ◽  
Magdalena Gizińska-Górna ◽  
Aneta Pytka-Woszczyło ◽  
...  

In this paper, the pollutant removal efficiency and the reliability of a vertical and horizontal flow hybrid constructed wetland (CW) planted with common reed, manna grass, and Virginia mallow were analyzed. The wastewater treatment plant, located in south-eastern Poland, treated domestic sewage at an average flow rate of 2.5 m3/d. The tests were carried out during five years of its operation (2014–2018). The following parameters were measured: biochemical oxygen demand (BOD5), chemical oxygen demand (COD), total suspended solids, total nitrogen, and total phosphorus. The results showed that more than 95% of BOD5, COD, and total phosphorus was removed in the tested CW system. The average effectiveness of removal of total suspended solids and total nitrogen exceeded 86%. A reliability analysis performed using the Weibull probability model showed that the removal reliability in the tested CW was very high for BOD5, COD, total suspended solids, and total phosphorus (100%). The probability that the total nitrogen concentration in the treated effluents would reach the limit value (30 mg/L) established for effluents discharged from a treatment plant of less than 2000 PE (population equivalent) to standing waters was 94%. The values of all the pollution indicators in wastewater discharged to the receiver were significantly lower than the limit values required in Poland. The investigated hybrid CW system with common reed, manna grass, and Virginia mallow guaranteed stable low values of BOD5, COD, total suspended solids, and total phosphorus in the treated wastewater, which meant it was highly likely to be positively evaluated in case of an inspection.


2018 ◽  
Vol 78 (9) ◽  
pp. 1879-1892 ◽  
Author(s):  
Md Khalekuzzaman ◽  
Muhammed Alamgir ◽  
Mehedi Hasan ◽  
Md Nahid Hasan

Abstract In this research, a hybrid anaerobic baffled reactor (HABR) configuration was proposed consisting of a front sedimentation chamber and four regular baffled chambers followed by two floated filter media chambers for the treatment of domestic wastewater. Performance comparison of uninsulated and insulated HABRs was carried out operating at warm temperature (18.6–37.6 °C) under variable HRTs (30 h and 20 h). The study suggests that almost similar chemical oxygen demand (91% vs 88%), total suspended solids (90% vs 95%), turbidity (98% vs 97%), and volatile suspended solids (90% vs 93%) removal efficiencies were obtained for uninsulated and insulated HABRs. Higher removal of total nitrogen (TN) of 41%, NH4+-N of 44%, and NO3−-N of 91% were achieved by the insulated HABR compared to TN of 37%, NH4+-N of 36%, and NO3−-N of 84% by the uninsulated HABR, whereas lower PO43− removal efficiency of 17% was found in the insulated HABR compared to 24% in the uninsulated HABR. This indicated insulation increased nitrogen removal efficiencies by 4% for TN, 8% for NH4+-N and 7% for NO3−-N, but decreased PO43−removal efficiency by 7%.


2007 ◽  
Vol 55 (4) ◽  
pp. 165-173
Author(s):  
T. Mietzel ◽  
K. Klepiszewski ◽  
G. Weiss

The water framework directive (CEC, 2000) asks for cost-effective measures for achieving good ecological conditions in receiving waters. Because of low operation costs and good pollutant removal efficiency, vortex separators (VS) are an attractive alternative to traditional stormwater tanks. The German design standard for CSO structures, ATV-A 128 (1992), demands long-term pollution load simulations. Today's simulation software, however, considers the removal processes in CSO structures either very rudimentarily or not at all. The higher pollutant removal efficiency of a structure like a VS cannot be taken into account. This might be one reason why VS are used still comparatively scarcely. A mathematical model describing the removal efficiency could increase the acceptance of VS. Several functions describing the removal efficiency have been derived from model tests or large-scale studies within the last few years. Within this paper, the data from three large-scale studies are used to verify the general applicability of one steady-state and one dynamic approach. The results show that the complex processes involved with CSO facilities and the large error related to monitoring make the validation of models a difficult task. Anyhow, especially the dynamic approach was applicable at all considered facilities.


2017 ◽  
Vol 314 ◽  
pp. 311-319 ◽  
Author(s):  
Ana Gómez-Ramírez ◽  
Antonio M. Montoro-Damas ◽  
Miguel A. Rodríguez ◽  
Agustín R. González-Elipe ◽  
José Cotrino

Sign in / Sign up

Export Citation Format

Share Document