Applications and limitations of ADM 1 in municipal wastewater solids treatment

2006 ◽  
Vol 54 (4) ◽  
pp. 77-82 ◽  
Author(s):  
B.R. Johnson ◽  
Y. Shang

The ADM 1 model has been implemented in a steady-state whole wastewater plant simulator. The ADM 1 model has been in use with good success for approximately 2 years on a wide range of wastewater treatment facilities. However, a number of modifications were necessary to allow it to be used in the context of municipal wastewater treatment. It was found that the model's use was greatly simplified if used in conjunction with a larger plant simulator to assist in the feed fractionation. It was also found that a better fit to actual operating data was achieved if some of the slowly biodegradable particulate fraction was partitioned into ADM particulate fractions other than the composite fraction. Another significant limitation of the model is in the absence of phosphorus modeling. The ADM model needs to have phosphorus handling for all the relevant fractions, and needs to include the handling of inorganic reactions such as struvite precipitation and metal phosphate/metal hydroxide precipitation. Activity effects on chemical equilibria are significant when considering phosphorus. Also of importance in wastewater treatment is the fate of sulfur compounds. This includes the generation of H2S in the digester gas and the fate of the sulfur species in the digested sludge (as a predictor of odour-generating potential).

2003 ◽  
Vol 3 (5-6) ◽  
pp. 321-327 ◽  
Author(s):  
M. Gallenkemper ◽  
T. Wintgens ◽  
T. Melin

Endocrine disrupting compounds can affect the hormone system in organisms. A wide range of endocrine disrupters were found in sewage and effluents of municipal wastewater treatment plants. Toxicological evaluations indicate that conventional wastewater treatment plants are not able to remove these substances sufficiently before disposing effluent into the environment. Membrane technology, which is proving to be an effective barrier to these substances, is the subject of this research. Nanofiltration provides high quality permeates in water and wastewater treatment. Eleven different nanofiltration membranes were tested in the laboratory set-up. The observed retention for nonylphenol (NP) and bisphenol A (BPA) ranged between 70% and 100%. The contact angle is an indicator for the hydrophobicity of a membrane, whose influence on the permeability and retention of NP was evident. The retention of BPA was found to be inversely proportional to the membrane permeability.


2011 ◽  
Vol 2011 (3) ◽  
pp. 328-349
Author(s):  
Ernest R. Blatchley ◽  
ShihChi Weng ◽  
Mehrnaz Zare Afifi ◽  
Hsiao-Han Chiu ◽  
Douglas B. Reichlin ◽  
...  

Author(s):  
Ю.А. Егорова ◽  
В.И. Кичигин ◽  
О.И. Нестеренко ◽  
А.А. Юдин

Осадки городских очистных канализационных сооружений являются самым массовым технологическим отходом, создающим проблемы утилизации для любого города. Рассмотрены возможные методы обработки осадков сточных вод на городских очистных канализационных сооружениях городского округа Самара с целью их последующей утилизации. Обозначены причины и приведены документальные подтверждениянекорректности возложения ответственности за обращение с такими отходами только на организации водопроводно-канализационного хозяйства. Рассмотрен способ захоронения обезвоженного осадка сточных вод в обвалованном полигоне. Установлено, что обработанные на очистных сооружениях осадки относятся к V классу опасности для окружающей среды. Обработанные, стабилизированные, подсушенные, обезвреженные отходы осадков сточных вод (малоопасный осадок с песколовок при очистке хозяйственно-бытовых и смешанных сточных вод, практически не опасный осадок с песколовок при очистке хозяйственно-бытовых и смешанных сточных вод и избыточный ил биологических очистных сооружений в смеси с сырым осадком) могут быть использованы в качестве наполнителей бетонно-цементных смесей и органоминеральных удобрений или переданы для утилизации сторонним организациям. Sludge from the municipal wastewater treatment facilities is the most massive technological waste that causes trouble for any city. Possible methods of wastewater sludge treatment at the municipal wastewater treatment facilities of the Samara Urban District with the purpose of its further utilization are considered. The reasons are indicated and documentary evidence of the incorrectness of assigning the responsibility for processing such wastes only to the water and wastewater utilities is provided. The method of landfilling dewatered wastewater sludge in a ridged landfill is considered. It has been established that the sludge processed at the wastewater treatment facilities is referred to the V class of environmental hazard. Sludge subjected to the treatment, stabilization, drying and neutralization (low hazardous sludge from grit chambers for domestic and mixed wastewater treatment; almost non-hazardous sludge from grit chambers for domestic and mixed wastewater treatment and excess sludge from biological treatment facilities mixed with raw sludge) can be used as fillers for concrete-cement mixtures and organo-mineral fertilizers or transferred for disposal to outside companies.


2019 ◽  
Vol 11 (3) ◽  
pp. 622 ◽  
Author(s):  
Isabella Pecorini ◽  
Francesco Baldi ◽  
Renato Iannelli

Four inocula collected from different operating facilities were tested in their hydrogenic performances by means of two biochemical hydrogen potential test set-ups using sucrose and food waste as substrates, with the aim of evaluating the influence of inoculum media in batch fermentative assays. The selected inocula were: activated sludge collected from the aerobic unit of a municipal wastewater treatment plant, digested sludge from an anaerobic reactor treating organic waste and cattle manure, digested sludge from an anaerobic reactor treating agroindustrial residues, and digested sludge from an anaerobic reactor of a municipal wastewater treatment plant. Test results, in terms of specific hydrogen production, hydrogen conversion efficiency, and volatile solids removal efficiency, were significantly dependent on the type of inoculum. Statistical analysis showed different results, indicating that findings were due to the different inocula used in the tests. In particular, assays performed with activated sludge showed the highest performances for both substrates and both experimental set-ups.


2006 ◽  
Vol 53 (8) ◽  
pp. 81-90 ◽  
Author(s):  
V. Parravicini ◽  
E. Smidt ◽  
K. Svardal ◽  
H. Kroiss

Further reduction of volatile suspended solids (VSS) during a post-stabilisation step was applied to evaluate the stabilisation degree of digested sewage sludge. For this purpose digested sludge was collected at four municipal wastewater treatment plants (WWTPs) and further stabilised in lab-scale chemostat reactors either under anaerobic or aerobic conditions. Experimental results showed that even in adequately digested sludge a consistent amount of VSS was degraded during aerobic post-stabilisation. It seems that aerobic conditions play a significant role during degradation of residual VSS. Additionally, specific VSS production (gVSS/peCOD110.d) as well as specific oxygen uptake rate were shown to be suitable parameters to assess the degree of sludge stabilisation at WWTPs. Fourier transform infrared spectroscopy was used to reveal changes in the sludge composition. Spectra of treated and untreated sludge samples indicated that the major component of residual VSS in stabilised sludge for instance consisted of biomass, while cellulose was absent.


Sign in / Sign up

Export Citation Format

Share Document