Impact of septic compounds and operational conditions on the microbiology of an activated sludge system

2007 ◽  
Vol 55 (6) ◽  
pp. 135-142 ◽  
Author(s):  
Carl Pelletier ◽  
Mary Ann Fitzsimmons ◽  
Sophie Deschênes ◽  
Michael Paice

In activated sludge (AS) biotreatment, septic compounds such as volatile organic acids and reduced sulphur compounds have been frequently cited as a major cause of Thiothrix and Type 021N filamentous bulking. These filaments are common in Canadian pulp and paper biotreatment systems, where they cause settling problems in secondary clarifiers. We conducted a 14-week study of a TMP/newsprint mill effluent to characterize the septic compounds entering the biotreatment, and to determine correlations with AS biomass characteristics and biotreatment operating parameters. A significant correlation was found between the sludge volume index, the abundance of Type 021N, and the propionic acid (PA) concentration in the primary clarified effluent. PA also induced a significant change in the flocculating bacteria size distribution determined by digital imaging. Consequently, the correlation observed between PA and Type 021N bulking is an indirect effect of inhibition of floc-forming microorganisms, giving a competitive advantage to filaments.

1997 ◽  
Vol 36 (4) ◽  
pp. 307-312
Author(s):  
Michael R. Rasmussen ◽  
Torben Larsen

An on-line settling column for measuring the dynamic variations of settling velocity of activated sludge has been developed. The settling column is automatic and self-cleansing insuring continuous and reliable measurements. The settling column was tested on sludge from a batch reactor where sucrose was added as an impulse to activated sludge. The continuous measurement of settling velocity revealed a highly dynamic response after the sucrose was added. The results were verified with simultaneous measurement of the initial settling rate. A 200 hour experiment showed variations in settling velocity, which was not apparent in the DSVI (Diluted Sludge Volume Index).


1994 ◽  
Vol 29 (7) ◽  
pp. 157-165 ◽  
Author(s):  
Gert Holm Kristensen ◽  
Per Elberg Jørgensen ◽  
Per Halkjær Nielsen

In 1989-91, a study was performed to investigate the settling characteristics of activated sludge in Danish treatment plants with biological nutrient removal. The study included three screening series on 38 treatment plants. Furthermore, the study included investigations during one year on seasonal variations in sludge settling characteristics at three treatment plants. The screening investigations were performed in November 1989 and May and September, 1990. Results showed that in the May-screening, 35-45% of the plants had a filament index of 2-2.5 or above, corresponding to a sludge volume index above 150 ml/g. When comparing data for diluted and non-diluted sludge volume indices, a SVI value of 150 ml/g seemed parallel to a DSVI of 110 ml/g. In the November- and September-screenings, some 30% of the plants had activated sludge showing a filament index in or above the critical area. Dominating filamentous microorganisms were found to be (in decreasing order): Microthrix parvicella, Type 0041, Type 021N, Type 0092, Type 0914, and Type 1851. A distinct variation over the year in sludge settling characteristics was found for the three plants. Sludge settling characteristics improved during summer, and deteriorated during winter. For activated sludge with a high content of filamentous microorganisms, the best parameter to follow the variations in sludge settling properties was the filament number. If the activated sludge concentration, the MLSS, varied significantly, the specific filament number was to be applied.


1997 ◽  
Vol 35 (8) ◽  
pp. 127-135 ◽  
Author(s):  
Youngchul Kim ◽  
Wesley O. Pipes ◽  
Paul-Gene Chung

This is a report of a field study based on data from an activated sludge process in a wastewater treatment plant in Chester, Pennsylvania, USA. The objective was to develop an accurate method for estimation of the average suspended solids concentration (SSB) of the layer of sludge in the settling tanks (the “sludge blanket”). Plant operators estimated SSB by averaging the mixed liquor suspended solids (Sm) and the return sludge suspended solids (Su) concentrations. Measurement of SSB showed that averaging Sm and Su frequently overestimated SSB by a large amount. A different relationship between SSB and parameters which are normally measured for operational purposes was developed. The parameters are Su, the overflow rates and data from the sludge volume index (SVI) measurement. It was found that an increasing overflow rate will result in an exponential decrease in the ratio of SSB to Su. Also, the SVI has a marked effect on the ratio of SSB to Su and thus on the amount of suspended solids which can be stored in the settling tanks. The proposed estimation equation was found to be statistically superior to estimation by averaging the Sm and Su.


2013 ◽  
Vol 11 (2) ◽  
pp. 218-222

Industrial facilities emit pollutant air that contains volatile organic compounds (VOCs) and reduced sulphur compounds (RSCs) which are nuisance, corrosive to materials and dangerous to health. In recent years, biofiltration has replaced numerous conventional processes (i.e. adsorption) due to its more effective, economical and environmental benefits. Thus, increasingly industrial facility operators are adopting biofilters for removal of air pollutants. Biofiltration takes place in bioreactors that are packed with media particles. On these media particles micro-organisms form biofilms where biological oxidation takes place. The new biofilter media developed in this study consists of a base material, hydrophobic coatings, nutrients and binding agents. In this contribution, method of development, evaluation and performance of this new bioreactor media are discussed.


2015 ◽  
Vol 57 (37) ◽  
pp. 17195-17205 ◽  
Author(s):  
Halime Boztoprak ◽  
Yüksel Özbay ◽  
Dünyamin Güçlü ◽  
Murat Küçükhemek

Author(s):  
Anna Gnida ◽  
Dagmara Witecy

A sludge from municipal wastewater plant operated for biological contaminant removal was exposed to three different negative pressures (-200, -500 and -800 hPa) for three different duration times (30 second, 1 and 2 minutes). Sludge volume index, shear sensitivity of the sludge and activated sludge floc characteristic was the object of the study before and after negative pressure treatment. After the treatment the sludge settled better independently on the pressure value and duration time. The shear sensitivity changed the most when the pressure exposure of -800 hPa was 1 minute and longer. The flocs structure was more open after negative pressur and larger part of activated sludge was comprised by large flocs.


REAKTOR ◽  
2015 ◽  
Vol 15 (3) ◽  
pp. 182
Author(s):  
Dian Fatikha Aristiami ◽  
I Nyoman Widiasa

The increase of population leads to an increase of the quantity of domestic wastewater. Activated sludge system is the most cost-efective to treat the domestic wastewater treatment. This study is aimed to evaluate the co-precipitation coagulant effect of FeCl3 on the growth of activated sludge, settling characteristics of the activated sludge, and effluent quality. sludge sedimentation characteristics (settling) as well as on the effluent quality. The activated sludge systems were operated in batch mode and synthetic domestic wastewaters with C:N:P ratio of 100:5:1 were used as feed wastewater. The growth of activated sludge was based on concentration of Mixed Liquor Suspended Solid (MLSS), settling characteristics of activated sludge was based on value of Sludge Volume Index (SVI), and effluent quality was based on turbidity, colour, N-ammonia concentration, and Chemical Oxygen Demand content. Results indicate that inhibition effect of FeCl3 to activated sludge activity was not significant at dosage ≤ 30 mg/L. Good settling characterisic (SVI 70-150 mg/L) was achieved at dosage of 20-30 mg/L. Finally, the best effluent quality, i.e. turbidity (9.4), colour (96), amonia removal (83.6%), and COD removal (72.97%), at dosage of 30 mg/L. Keywords: activated sludge; co-precipitation; domestic wastewater; wastewater treatment Abstrak Peningkatan jumlah penduduk mengakibatkan kenaikan jumlah air limbah domestik. Sistem lumpur aktif merupakan proses yang paling efektif untuk mengolah air limbah domestik. Penelitian ini bertujuan untuk mengevaluasi pengaruh co-precipitation koagulan FeCl3 terhadap pertumbuhan lumpur aktif, karakteristik pengendapan lumpur aktif, dan kualitas efluen. Sistem lumpur aktif dioperasikan secara curah dan umpan air limbah yang digunakan adalah air limbah domestik sintesis dengan rasio C:N:P = 100:5:1. Pertumbuhan lumpur aktif  berdasarkan konsentrasi Mixed Liquor Suspended Solid (MLSS), karakteristik pengendapan lumpur berdasarkan  nilai Sludge Volume Index (SVI), dan kualitas efluen berdasarkan tingkat kekeruhan, warna, kadar N-amonia dan kadar Chemical Oxygen Demand (COD). Hasil penelitian menunjukkan bahwa inhibisi FeCl3 terhadap aktivitas lumpur aktif tidak signifikan pada dosis ≤ 30 mg/L. Karakteristik pengendapan yang baik (SVI 70-150 mg/L) tercapai pada dosis 20-30 mg/L. Kualitas efluen terbaik, yaitu  kekeruhan (9,4),  warna (96), penyisihan amonia (83,6%) dan penyisihan COD (72,97%), pada dosis 30 mg/L. Kata kunci: lumpur aktif; co-precipitation; air limbah domestik; pengolahan air limbah  


1994 ◽  
Vol 29 (5-6) ◽  
pp. 303-311
Author(s):  
J. Wessberg ◽  
T. Welander ◽  
M. Jönsson

Laboratory activated sludge reactors were operated on effluent wastewater from a kraft mill. Two of the three reactors were initially preceded with a “normal” size aerated selector, 2% of the total aerated volume, with unsatisfactory sludge volume index development. When the selectors were replaced by larger ones, 13% of the aerated volume, the sludge volume index could be kept below 50 ml/g for the selector processes while continuing to be higher and more unstable in the reference process. A pilot plant, operated in situ on the same wastewater, showed a comparable improvement in sludge volume index when its selector, 7% of the total volume, was replaced by one that constituted 13% of the total volume, corresponding to a selector load of 3 g BOD / g VSS * d. According to studies of the COD balance around one bench scale selector, the COD removal mechanism in the selector was respiration/assimilation rather than uptake/storage.