Settling Characteristics of Activated Sludge in Danish Treatment Plants with Biological Nutrient Removal

1994 ◽  
Vol 29 (7) ◽  
pp. 157-165 ◽  
Author(s):  
Gert Holm Kristensen ◽  
Per Elberg Jørgensen ◽  
Per Halkjær Nielsen

In 1989-91, a study was performed to investigate the settling characteristics of activated sludge in Danish treatment plants with biological nutrient removal. The study included three screening series on 38 treatment plants. Furthermore, the study included investigations during one year on seasonal variations in sludge settling characteristics at three treatment plants. The screening investigations were performed in November 1989 and May and September, 1990. Results showed that in the May-screening, 35-45% of the plants had a filament index of 2-2.5 or above, corresponding to a sludge volume index above 150 ml/g. When comparing data for diluted and non-diluted sludge volume indices, a SVI value of 150 ml/g seemed parallel to a DSVI of 110 ml/g. In the November- and September-screenings, some 30% of the plants had activated sludge showing a filament index in or above the critical area. Dominating filamentous microorganisms were found to be (in decreasing order): Microthrix parvicella, Type 0041, Type 021N, Type 0092, Type 0914, and Type 1851. A distinct variation over the year in sludge settling characteristics was found for the three plants. Sludge settling characteristics improved during summer, and deteriorated during winter. For activated sludge with a high content of filamentous microorganisms, the best parameter to follow the variations in sludge settling properties was the filament number. If the activated sludge concentration, the MLSS, varied significantly, the specific filament number was to be applied.

1997 ◽  
Vol 36 (4) ◽  
pp. 307-312
Author(s):  
Michael R. Rasmussen ◽  
Torben Larsen

An on-line settling column for measuring the dynamic variations of settling velocity of activated sludge has been developed. The settling column is automatic and self-cleansing insuring continuous and reliable measurements. The settling column was tested on sludge from a batch reactor where sucrose was added as an impulse to activated sludge. The continuous measurement of settling velocity revealed a highly dynamic response after the sucrose was added. The results were verified with simultaneous measurement of the initial settling rate. A 200 hour experiment showed variations in settling velocity, which was not apparent in the DSVI (Diluted Sludge Volume Index).


2000 ◽  
Vol 42 (3-4) ◽  
pp. 283-288 ◽  
Author(s):  
Z. Yun ◽  
W. Yo ◽  
Y. Yi ◽  
S. Choi ◽  
E. Choi ◽  
...  

Although the BNR system design assumes no sludge settling problems in the final settling tank, the fluctuation of daily loading and up to 40% of anaerobiosis in the BNR system would be considerable factors in determining the sludge settleability. The sludge volume index (SVI) is a classical parameter to examine the sludge settleability but it has a limited value to evaluate the overall settling characteristics. The extracellular polymer (ECP) content in sludge has long been considered as an indicator of biological flocculation in activated sludge process, but the skepticism on analytical accuracy limits the usage in settling study. This study focused on evaluating the BNR system performance related to the sludge settling characteristics under the controlled laboratory environment. A 5-stage BNR system (anaerobic-anoxic-3 stage oxic) was operated with the HRTs from 3.9 to 7.6 hours. In order to determine the sludge settling properties, both SVI and ECP content were monitored. The ECP contents in the sludge sample were measured by the slime-washing step followed by high-G centrifugation and sonication. The gel-electrophoresis was used to detect the DNA in the sonicated samples to determine the intracellular polymer contamination. It has been found that the anaerobiosis in the anaerobic and anoxic zone that consisted of 37% of reactor volume could not deteriorate the sludge settling properties even at the HRT of 3.9 hours. The SVI values of sludge taken from the reactor with the HRT of 7.2 hours averaged to less than 50 mL/gr. It was postulated that a fast settling sludge in the BNR system could not always ensure production of clear effluent. The sludge with very low SVI might not achieve a complete biological flocculation potential. In addition, the degree of denitrification in the BNR system could be related to the sludge settleability.


2010 ◽  
Vol 44 (5) ◽  
pp. 1553-1561 ◽  
Author(s):  
Hyun-su Kim ◽  
James W. Gellner ◽  
Joshua P. Boltz ◽  
Robert G. Freudenberg ◽  
Claudia K. Gunsch ◽  
...  

1997 ◽  
Vol 35 (8) ◽  
pp. 127-135 ◽  
Author(s):  
Youngchul Kim ◽  
Wesley O. Pipes ◽  
Paul-Gene Chung

This is a report of a field study based on data from an activated sludge process in a wastewater treatment plant in Chester, Pennsylvania, USA. The objective was to develop an accurate method for estimation of the average suspended solids concentration (SSB) of the layer of sludge in the settling tanks (the “sludge blanket”). Plant operators estimated SSB by averaging the mixed liquor suspended solids (Sm) and the return sludge suspended solids (Su) concentrations. Measurement of SSB showed that averaging Sm and Su frequently overestimated SSB by a large amount. A different relationship between SSB and parameters which are normally measured for operational purposes was developed. The parameters are Su, the overflow rates and data from the sludge volume index (SVI) measurement. It was found that an increasing overflow rate will result in an exponential decrease in the ratio of SSB to Su. Also, the SVI has a marked effect on the ratio of SSB to Su and thus on the amount of suspended solids which can be stored in the settling tanks. The proposed estimation equation was found to be statistically superior to estimation by averaging the Sm and Su.


REAKTOR ◽  
2015 ◽  
Vol 15 (3) ◽  
pp. 182
Author(s):  
Dian Fatikha Aristiami ◽  
I Nyoman Widiasa

The increase of population leads to an increase of the quantity of domestic wastewater. Activated sludge system is the most cost-efective to treat the domestic wastewater treatment. This study is aimed to evaluate the co-precipitation coagulant effect of FeCl3 on the growth of activated sludge, settling characteristics of the activated sludge, and effluent quality. sludge sedimentation characteristics (settling) as well as on the effluent quality. The activated sludge systems were operated in batch mode and synthetic domestic wastewaters with C:N:P ratio of 100:5:1 were used as feed wastewater. The growth of activated sludge was based on concentration of Mixed Liquor Suspended Solid (MLSS), settling characteristics of activated sludge was based on value of Sludge Volume Index (SVI), and effluent quality was based on turbidity, colour, N-ammonia concentration, and Chemical Oxygen Demand content. Results indicate that inhibition effect of FeCl3 to activated sludge activity was not significant at dosage ≤ 30 mg/L. Good settling characterisic (SVI 70-150 mg/L) was achieved at dosage of 20-30 mg/L. Finally, the best effluent quality, i.e. turbidity (9.4), colour (96), amonia removal (83.6%), and COD removal (72.97%), at dosage of 30 mg/L. Keywords: activated sludge; co-precipitation; domestic wastewater; wastewater treatment Abstrak Peningkatan jumlah penduduk mengakibatkan kenaikan jumlah air limbah domestik. Sistem lumpur aktif merupakan proses yang paling efektif untuk mengolah air limbah domestik. Penelitian ini bertujuan untuk mengevaluasi pengaruh co-precipitation koagulan FeCl3 terhadap pertumbuhan lumpur aktif, karakteristik pengendapan lumpur aktif, dan kualitas efluen. Sistem lumpur aktif dioperasikan secara curah dan umpan air limbah yang digunakan adalah air limbah domestik sintesis dengan rasio C:N:P = 100:5:1. Pertumbuhan lumpur aktif  berdasarkan konsentrasi Mixed Liquor Suspended Solid (MLSS), karakteristik pengendapan lumpur berdasarkan  nilai Sludge Volume Index (SVI), dan kualitas efluen berdasarkan tingkat kekeruhan, warna, kadar N-amonia dan kadar Chemical Oxygen Demand (COD). Hasil penelitian menunjukkan bahwa inhibisi FeCl3 terhadap aktivitas lumpur aktif tidak signifikan pada dosis ≤ 30 mg/L. Karakteristik pengendapan yang baik (SVI 70-150 mg/L) tercapai pada dosis 20-30 mg/L. Kualitas efluen terbaik, yaitu  kekeruhan (9,4),  warna (96), penyisihan amonia (83,6%) dan penyisihan COD (72,97%), pada dosis 30 mg/L. Kata kunci: lumpur aktif; co-precipitation; air limbah domestik; pengolahan air limbah  


2002 ◽  
Vol 46 (1-2) ◽  
pp. 471-478 ◽  
Author(s):  
O. Krhutková ◽  
I. Ruzicková ◽  
J. Wanner

The long-term project on the survey of filamentous microorganisms, which started in 1996, was finished in 2000 by the survey of eight Czech activated sludge plants with biological nutrient removal (BNR) systems. At all plants with enhanced biological nutrient removal, specific microbial population (mostly from the point of view of filaments occurrence), operational problems (presence of biological foaming, bulking) and plant operation were observed periodically and longer than 1 year. In our paper the relationship between the composition of activated sludge (especially filaments) consortia and modification of the process with nutrient removal is discussed. At the surveyed plants Type 0092 and Microthrix parvicella were identified as dominant Eikelboom filamentous types.


2004 ◽  
Vol 50 (7) ◽  
pp. 281-285 ◽  
Author(s):  
R. Jenné ◽  
E.N. Banadda ◽  
I.Y. Smets ◽  
J.F. Van Impe

The goal of this study is to develop a monitoring system for activated sludge properties, as this is an essential tool in the battle against filamentous bulking. A fully automatic image analysis procedure for recognising and characterising flocs and filaments in activated sludge images has been optimised and subsequently used to monitor activated sludge properties in a lab-scale installation. The results of two experiments indicate that the image information correlates well with the Sludge Volume Index. It is shown that, at the onset of filamentous bulking, there is an increase in total filament length on the one hand, and a change in floc shape on the other hand.


1984 ◽  
Vol 16 (10-11) ◽  
pp. 55-67 ◽  
Author(s):  
L Eriksson ◽  
A.-M Härdin

When characterizing sludge settling by means of sludge volume index and stirred sludge volume index it has been found that the former is normally higher, but that the difference varies greatly for different sludges. It was found to depend on difference in shape of the flocs. Spherical flocs give small differences and elongated flocs give large ones. Although both indices were positively correlated to the total length of filamentous organisms the differences were not. A general floc model is proposed on the basis of these findings together with colloid chemical considerations and measurements of floc strength, filtration resistance and amount of extracellular polymers. According to this model young flocs are of the elongated type, while flocs from a stable system are round. Sludge bulking is a consequence of stiff noncompressible flocs which may be due to high amounts of dissolved polymers, but most likely to filamentous organisms fixed in a network by binding polymers within the flocs. The amount of filaments inside the flocs is probably proportional to the amount outside which for that reason is correlated to the settling indices.


2001 ◽  
Vol 43 (6) ◽  
pp. 193-196 ◽  
Author(s):  
H.-S. Shin ◽  
S.-T. Kang ◽  
S.-Y. Nam

EPSs have been believed to play a bonding role in microbial floc formation. However, the precise role is not well known. In this study, sludge settling characteristics and the carbohydrate to protein ratio in the EPS were tested at various airflow rates. Sludge was collected from three modified sequencing batch reactors (MSBRs), which were operated with airflow rates of 0.8 L/min, 2 L/min and 4 L/min, respectively. During the operation periods, the reactor operated at an airflow rate of 0.8 L/min showed a sludge volume index (SVI) of 80 to 90 mL/g and a constant ratio of carbohydrate to protein in the EPS, while a significant increase of this ratio and the SVI occurred in the other reactors. High airflow rate increased the amount of carbohydrate in the EPS, but the protein level was almost constant for reactors with airflow rates of 2 L/min and 4 L/min. The higher ratio of carbohydrate to protein caused the bulking of the sludge; hence it was not favourable for sludge settling. The ratio of carbohydrate and protein in the EPS is inferred to be essential for solid floc formation.


1996 ◽  
Vol 33 (12) ◽  
pp. 137-146 ◽  
Author(s):  
Kjær Andreasen ◽  
Lars Sigvardsen

SVI and DSVI were measured three times at almost 100 Danish nutrient removal plants and the filamentous microorganisms were subsequently characterized in the laboratory. Information about the plant layout and the operation was collected by means of a questionnaire. In general, the sludge settleability index becomes worse by the introduction of nutrient removal. Among nutrient removal plants the best settling characteristics are found among plants with biological P removal and the poorest among the plants that perform simultaneous denitrification. When compared to iron products, aluminium products in some cases seem to reduce the filament number and improve the settling characteristics in plants that apply simultaneous precipitation for P removal. Selectors may have a positive effect on the filament number but the effect may not be enough to prevent bulking.


Sign in / Sign up

Export Citation Format

Share Document