A comparison study on Acid Red 119 dye removal using two different types of waterworks sludge

2010 ◽  
Vol 61 (7) ◽  
pp. 1673-1681 ◽  
Author(s):  
S. Sadri Moghaddam ◽  
M. R. Alavi Moghaddam ◽  
M. Arami

This study aims to compare the performance of two waterworks sludge samples, ferric chloride sludge (FCS) and polyaluminium chloride sludge (PACS), as coagulants to remove Acid Red 119 (AR119) dye from aqueous solution. A series of batch experiments were performed to investigate the effect of initial pH, coagulant dosage and initial dye concentration on coagulation/flocculation process efficiency. Results showed that the dye removal was strongly pH-dependent and followed the same trend for both coagulants, increasing steadily with decreasing initial pH in the range of 3–12. With the increase of coagulant dosage, the dye removal efficiency increased and no re-stabilization phenomenon was observed. However, the coagulant dosage needed for the maximum dye removal efficiency was much lower for FCS (150 mg dried sludge/L) in compare with PACS (5.5 g dried sludge/L). It seems that both charge neutralization and sweep flocculation mechanisms were involved in removal of AR119 using FCS and PACS. With the increase of initial dye concentration, Q (the amount of the removed dye per unit mass of coagulant) steadily increased and reached to a maximum value of 0.96 mg dye/mg sludge and 0.029 mg dye/mg sludge for FCS and PACS, respectively. FCS was more effective than PACS for AR119 dye removal due to the higher amount of dye removed per unit mass of sludge.

2013 ◽  
Vol 743-744 ◽  
pp. 665-668
Author(s):  
Ji Zhou Li ◽  
Xu Yin Yuan ◽  
Ming Tian ◽  
Hao Ran Ji ◽  
Wan Jiang

Five novel coagulants, DC-491, Fennofix K97, BWD-01, MD-03 and MD-04 were chosen to treat reactive brilliant red X-3B simulated wastewater by jar tests. The results showed that the decolorization efficiencies were all higher than 75% at initial pH 8.2 and temperature 20 after 20 minutes of reaction. Then, two typical coagulants, BWD-01 and MD-04 which had better performance were chosen to study the effect of dye removal of X-3B at different operating parameters, including coagulant dosage, pH, sedimentaion time and reaction temperature of simulated wastewater. Decolorization efficiency of MD-04 for X-3B solution was higher than 80% in pH range from 3 to 9, while for BWD-01, efficiency increased from 37.3% to 82.3% in this pH range. For both BWD-01 and MD-04, the color removal efficiency increased as the solution temperature increased and the maximum efficiency was over 94% at 40. Small changes in the color removal efficiency were observed after 1 hour sedimentation for both coagulants.


2015 ◽  
Vol 18 (1) ◽  
pp. 38-46 ◽  

<div> <p>This study was conducted to investigate the effect of praestol, as a coagulant-aid, to improve coagulation-flocculation process in the removal of disperse red 60 from aqueous solutions. The effect of various parameters including coagulants dose (10-1000 mg l<sup>-1</sup>), praestol dose (0-1000 mg l<sup>-1</sup>), solution pH (3-11), initial dye concentration (100-500 mg l<sup>-1</sup>), flocculation speed (30-60 rpm), flocculation time (15-30 min), settling time (5-60 min) and ionic strength (0-6 mg l<sup>-1</sup>) was evaluated on the dye removal. The dye removal efficiency was substantially increased by using praestol in the concentration of 80 mg l<sup>-1 </sup>and 400 mg l<sup>-1 </sup>for coagulation with alum and polyaluminum chloride (PACl), respectively. The maximum dye removal by alum coupled with praestol (Al-P) and PACl coupled with praestol (PA-P) was found to be 97.8% and 98.7%, respectively that were occurred at pH 7. The results showed that the application of PA-P or Al-P can be effectively used to remove disperse red 60 (DR 60) in aqueous solutions.</p> </div> <p>&nbsp;</p>


Author(s):  
Ho Truong Nam Hai ◽  
Nguyen Tuyet Vy ◽  
Nguyen Thao Nguyen ◽  
To Thi Hien

Currently, microplastics (MP) in the water environment is a global issue. Microplastics enter the natural environment through various sources such as domestic wastewater and industrial wastewater. The flocculation method - one of the simple and effective methods commonly used in wastewater treatment plants was used in this study to determine the removal efficiency of MPs in the industrial wastewater. The coagulation/flocculation experiments were carried on the Jartest model with the iron coagulant under different conditions. The wastewater was taken from the industrial park Song Than 1. The volume of the wastewater in each experiment was 500 mL with the MPs concentration of 78.4 mg/L which included 3 main forms with MP bead (322 different types / 0.5 L), MP fragment (131 different types / 0.5 L) and MP fiber (125 different types / 0.5 L). The optimal condition of microplastic removal (iron coagulant (FeCl3) = 600 mg/L, pH 8.6 – 8.8, settling time = 60 minutes, fast stirring of 300 rpm, slow stirring of 25 rpm, supporting-coagulant (CPAM) = 50 mg/L) was determined, corresponding with the MPs removal efficiency of 93.11% (MPs in effluent was 7.33 mg/L). The most common MPs categories collected after treatment were MP fragments (19 different types) and MP fibers (17 different types). MPs dimensions were mostly about 0.5 to 1 mm. Our result showed that the coagulation/flocculation process was an efficient method for the removal MPs in the industrial wastewater.


Author(s):  
Reza Ali Fallahzadeh ◽  
Davoud Ghadirian ◽  
Ahmad Fattahi ◽  
Pejman Amjadian ◽  
Samaneh Mozaffary ◽  
...  

Introduction: Disposal of the wastewater produced in the paper and paperboard industry without the refining process can add substances to the environment, which are harmful to humans, environment, and other organisms. With regard to process efficiency, the current methods used in wastewater treatment of this industry are economically unjustifiable. Therefore, in this research, the electrolysis / electrocoagulation method was investigated using a graphite / iron electrode for synthetic aqueous solutions containing golden yellow X-GL. Materials and Methods: In this test, two Plexiglas reactors with a volume of 3 liters were used. The impact of the operation parameters such as voltage, initial dye concentration, and reaction time were investigated. Dye concentration in specimens was determined by visible spectrophotometry using DR-5000 at 438nm wavelength. Results: In optimal conditions of voltage 12V, dye concentration 10 mg/l, and time 60 min, the removal efficiency rates of electrolysis reactors, electric coagulation, and combined reactor were 64.17%, 75.42%, and 84.19% respectively. By increasing the dye concentration and decreasing the voltage, the dye removal efficiency decreased. Conclusion: The electric coagulation process using an iron electrode is a suitable method for removing the yellow color of colored aqueous solutions from the paper and paperboard industry.


2011 ◽  
Vol 340 ◽  
pp. 236-240
Author(s):  
Jian Feng Ma ◽  
Jian Ming Yu ◽  
Bing Ying Cui ◽  
Ding Long Li ◽  
Juan Dai

Inorganic-organic-bentonite was synthesized by modification of bentonite by Hydroxy-iron and surfactant, which could be applied in dye removal by adsorption and catalysis. The removal of acid dye Orange II was studied at various factors such as time and pH of solution. The results showed that the inorganic-organic-bentonite could efficiently remove the dye with efficiency of 96.22%. The maximum adsorption capacity is 76 mg/g. The pH of solution has significant effect on both adsorption and catalysis. When pH was 4, the maximum removal efficiency of adsorption and catalysis were 97.57% and 87.23%, respectively. After degradation, the secondary pollution was diminished and the bentonite could be reused.


Author(s):  
Haiyan Song ◽  
Wei Liu ◽  
Fansheng Meng ◽  
Qi Yang ◽  
Niandong Guo

Nanoscale zero-valent iron (nZVI) has attracted considerable attention for its potential to sequestrate and immobilize heavy metals such as Cr(VI) from an aqueous solution. However, nZVI can be easily oxidized and agglomerate, which strongly affects the removal efficiency. In this study, graphene-based nZVI (nZVI/rGO) composites coupled with ultrasonic (US) pretreatment were studied to solve the above problems and conduct the experiments of Cr(VI) removal from an aqueous solution. SEM-EDS, BET, XRD, and XPS were performed to analyze the morphology and structures of the composites. The findings showed that the removal efficiency of Cr(VI) in 30 min was increased from 45.84% on nZVI to 78.01% on nZVI/rGO and the removal process performed coupled with ultrasonic pretreatment could greatly shorten the reaction time to 15 min. Influencing factors such as the initial pH, temperature, initial Cr(VI) concentration, and co-existing anions were studied. The results showed that the initial pH was a principal factor. The presence of HPO42−, NO3−, and Cl− had a strong inhibitory effect on this process, while the presence of SO42− promoted the reactivity of nZVI/rGO. Combined with the above results, the process of Cr(VI) removal in US-nZVI/rGO system consisted of two phases: (1) The initial stage is dominated by solution reaction. Cr(VI) was reduced in the solution by Fe2+ caused by ultrasonic cavitation. (2) In the following processes, adsorption, reduction, and coprecipitation coexisted. The addition of rGO enhanced electron transportability weakened the influence of passivation layers and improved the dispersion of nZVI particles. Ultrasonic cavitation caused pores and corrosion at the passivation layers and fresh Fe0 core was exposed, which improved the reactivity of the composites.


Plants ◽  
2021 ◽  
Vol 10 (2) ◽  
pp. 384
Author(s):  
Ahmed Labena ◽  
Ahmed E. Abdelhamid ◽  
Abeer S. Amin ◽  
Shimaa Husien ◽  
Liqaa Hamid ◽  
...  

Biosorption is a bioremediation approach for the removal of harmful dyes from industrial effluents using biological materials. This study investigated Methylene blue (M. blue) and Congo red (C. red) biosorption from model aqueous solutions by two marine macro-algae, Ulva fasciata and Sargassum dentifolium, incorporated within acrylic fiber waste to form composite membranes, Acrylic fiber-U. fasciata (AF-U) and Acrylic fiber-S. dentifolium (AF-S), respectively. The adsorption process was designed to more easily achieve the 3R process, i.e., removal, recovery, and reuse. The process of optimization was implemented through one factor at a time (OFAT) experiments, followed by a factorial design experiment to achieve the highest dye removal efficiency. Furthermore, isotherm and kinetics studies were undertaken to determine the reaction nature. FT-IR and SEM analyses were performed to investigate the properties of the membrane. The AF-U membrane showed a significant dye removal efficiency, of 88.9% for 100 ppm M. blue conc. and 79.6% for 50 ppm C. red conc. after 240 min sorption time. AF-S recorded a sorption capacity of 82.1% for 100 ppm M. blue conc. after 30 min sorption time and 85% for 100 ppm C. red conc. after 240 min contact time. The membranes were successfully applied in the 3Rs process, in which it was found that the membranes could be used for five cycles of the removal process with stable efficiency.


2021 ◽  
Vol 11 (5) ◽  
pp. 2344
Author(s):  
Srikanth Vuppala ◽  
Riyaaz Uddien Shaik ◽  
Marco Stoller

Olive oil production is one of the important industrial sectors within the agro-food framework of the Mediterranean region, economically important to the people working in this sector, although there is also a threat to the environment due to residues. The main wastes of the olive oil extraction process are olive mill wastewater (OMW) and olive husks which also require proper treatment before dismissal. In this research work, the main goal is to introduce grey relational analysis, a technique for multi-response optimization, to the coagulation and flocculation process of OMW to select the optimum coagulant dosage. The coagulation and flocculation process was carried out by adding aluminum sulfate (Alum) to the waste stream in different dosages, starting from 100 to 2000 mg/L. In previous research work, optimization of this process on OMW was briefly discussed, but there is no literature available that reports the optimal coagulant dosage verified through the grey relational analysis method; therefore, this method was applied for selecting the best operating conditions for lowering a combination of multi-responses such as chemical oxygen demand (COD), total organic carbon (TOC), total phenols and turbidity. From the analysis, the 600 mg/L coagulant dosage appears to be top ranked, which obtained a higher grey relational grade. The implementation of statistical techniques in OMW treatment can enhance the efficiency of this process, which in turn supports the preparation of waste streams for further purification processes in a sustainable way.


2011 ◽  
Vol 6 (1) ◽  
Author(s):  
M. Behbahani ◽  
M.R. Alavi Moghaddam ◽  
M. Arami

The aim of this study is to examine the effect of operational parameters on fluoride removal using electrocoagulation method. For this purpose, various operational parameters including initial pH, initial fluoride concentration, applied current, reaction time, electrode connection mode, anode material, electrolyte salt, electrolyte concentration, number of electrodes and interelectrode distance were investigated. The highest defluoridation efficiency achieved at initial pH 6. In the case of initial fluoride concentration, maximum removal efficiency (98.5%) obtained at concentration of 25mg/l. The increase of applied current and reaction time improved defluoridation efficiency up to 99%. The difference of fluoride removal efficiencies between monopolar and bipolar series and monopolar parallel were significant, especially at reaction time of 5 min. When aluminum used as anode material, higher removal efficiency (98.5%) achieved compared to that of iron anode (67.7%). The best electrolyte salt was NaCl with the maximum defluoridation efficiency of 98.5% compared to KNO3 and Na2SO4. The increase of NaCl had no effect on defluoridation efficiency. Number of electrodes had little effect on the amounts of Al3+ ions released in the solution and as a result defluoridation efficiency. Almost the same fluoride removal efficiency obtained for different interelectrode distances.


2016 ◽  
Vol 74 (3) ◽  
pp. 564-579 ◽  
Author(s):  
Ceyhun Akarsu ◽  
Yasin Ozay ◽  
Nadir Dizge ◽  
H. Elif Gulsen ◽  
Hasan Ates ◽  
...  

Marine pollution has been considered an increasing problem because of the increase in sea transportation day by day. Therefore, a large volume of bilge water which contains petroleum, oil and hydrocarbons in high concentrations is generated from all types of ships. In this study, treatment of bilge water by electrocoagulation/electroflotation and nanofiltration integrated process is investigated as a function of voltage, time, and initial pH with aluminum electrode as both anode and cathode. Moreover, a commercial NF270 flat-sheet membrane was also used for further purification. Box–Behnken design combined with response surface methodology was used to study the response pattern and determine the optimum conditions for maximum chemical oxygen demand (COD) removal and minimum metal ion contents of bilge water. Three independent variables, namely voltage (5–15 V), initial pH (4.5–8.0) and time (30–90 min) were transformed to coded values. The COD removal percent, UV absorbance at 254 nm, pH value (after treatment), and concentration of metal ions (Ti, As, Cu, Cr, Zn, Sr, Mo) were obtained as responses. Analysis of variance results showed that all the models were significant except for Zn (P &gt; 0.05), because the calculated F values for these models were less than the critical F value for the considered probability (P = 0.05). The obtained R2 and Radj2 values signified the correlation between the experimental data and predicted responses: except for the model of Zn concentration after treatment, the high R2 values showed the goodness of fit of the model. While the increase in the applied voltage showed negative effects, the increases in time and pH showed a positive effect on COD removal efficiency; also the most effective linear term was found as time. A positive sign of the interactive coefficients of the voltage–time and pH–time systems indicated synergistic effect on COD removal efficiency, whereas interaction between voltage and pH showed an antagonistic effect.


Sign in / Sign up

Export Citation Format

Share Document