scholarly journals Hearing Aid Selection: Closed- versus Open-canal Fitting Hearing Aids

2021 ◽  
Vol 17 (4) ◽  
pp. 323-330
Author(s):  
Sangyeon Lee ◽  
Soo Hee Oh ◽  
Kyoungwon Lee

To select hearing aid is an essential process for successful hearing rehabilitation. The purpose of this study is to review hearing aid selection considerations between receiver in-the-canal (RIC) and custom hearing aid (CHA) in order to guide appropriate selection of the hearing aid. This study discussed three key factors in the hearing aid selection including physical, acoustic and electroacoustic characteristics and other aspects. Advantages of RIC types are comfort to wear, reduction of the occlusion effect, presence of directional microphones, on-site fit, easy connectivity with other devices, and use of rechargeable batteries. On the other hand, the CHA types have their advantage in terms of being comfort to wear with masks, proper insertion and placement, reduction of the acoustic feedback, good approximation of frequency response curve, improvement of speech in noise perception, expanded hearing aid candidacy with varying hearing thresholds, and easy telephone use. We concluded that appropriate selection of the hearing aid would contribute to successful hearing rehabilitation, if considering physical, psycho-social, and acoustical characteristics.

2004 ◽  
Vol 15 (09) ◽  
pp. 649-659 ◽  
Author(s):  
Ruth A. Bentler ◽  
Jessica L.M. Egge ◽  
Jill L. Tubbs ◽  
Andrew B. Dittberner ◽  
Gregory A. Flamme

The purpose of this study was to assess the relationship between the directivity of a directional microphone hearing aid and listener performance. Hearing aids were fit bilaterally to 19 subjects with sensorineural hearing loss, and five microphone conditions were assessed: omnidirectional, cardioid, hypercardioid, supercardioid, and "monofit," wherein the left hearing aid was set to omnidirectional and the right hearing aid to hypercardioid. Speech perception performance was assessed using the Hearing in Noise Test (HINT) and the Connected Speech Test (CST). Subjects also assessed eight domains of sound quality for three stimuli (speech in quiet, speech in noise, and music). A diffuse soundfield system composed of eight loudspeakers forming the corners of a cube was used to output the background noise for the speech perception tasks and the three stimuli used for sound quality judgments. Results indicated that there were no significant differences in the HINT or CST performance, or sound quality judgments, across the four directional microphone conditions when tested in a diffuse field. Of particular interest was the monofit condition: Performance on speech perception tests was the same whether one or two directional microphones were used.


2020 ◽  
Author(s):  
Willy Nguyen ◽  
Miseung Koo ◽  
Seung Ha Oh ◽  
Jun Ho Lee ◽  
Moo Kyun Park

BACKGROUND Underuse of hearing aids is caused by several factors, including the stigma associated with hearing disability, affordability, and lack of awareness of rising hearing impairment associated with the growing population. Thus, there is a significant opportunity for the development of direct-to-consumer devices. For the past few years, smartphone-based hearing-aid apps have become more numerous and diverse, but few studies have investigated them. OBJECTIVE This study aimed to elucidate the electroacoustic characteristics and potential user benefits of a selection of currently available hearing-aid apps. METHODS We investigated the apps based on hearing-aid control standards (American National Standards Institute) using measurement procedures from previous studies. We categorized the apps and excluded those we considered inefficient. We investigated a selection of user-friendly, low-end apps, EarMachine and Sound Amplifier, with warble-tone audiometry, word recognition testing in unaided and aided conditions, and hearing-in-noise test in quiet and noise-front conditions in a group of users with mild hearing impairment (n = 7) as a pilot for a future long-term investigation. Results from the apps were compared with those of a conventional hearing aid. RESULTS Five of 14 apps were considered unusable based on low scores in several metrics, while the others varied across the range of electroacoustic measurements. The apps that we considered “high end” that provided lower processing latencies and audiogram-based fitting algorithms were superior overall. The clinical performance of the listeners tended to be better when using hearing aid, while the low end hearing-aid apps had limited benefits on the users. CONCLUSIONS Some apps showed the potential to benefit users with limited cases of minimal or mild hearing loss if the inconvenience of relatively poor electroacoustic performance did not outweigh the benefits of amplification.


2002 ◽  
Vol 13 (09) ◽  
pp. 503-520
Author(s):  
Francis Kuk ◽  
Andre Marcoux

Ensuring consistent audibility is an important objective when fitting hearing aids to children. This article reviews the factors that could affect the audibility of the speech signals to children. These factors range from a precise determination of the child's hearing loss to an accurate specification of gain in the chosen hearing aids. In addition, hearing aid technology and features such as multichannel processing, directional microphones, and feedback cancellation that could affect the achievement of consistent audibility are reviewed.


2005 ◽  
Vol 16 (09) ◽  
pp. 653-661
Author(s):  
Francis Kuk ◽  
Denise Keenan ◽  
Chi-Chuen Lau ◽  
Nick Dinulescu ◽  
Richard Cortez ◽  
...  

The present study compared differences in subjective and objective performance in completely-in-the-canal (CIC) hearing aids with conventional uniform 1.5 mm parallel vents and another with a reverse horn vent where the diameter increased from 1.5 mm on the lateral faceplate to 3 mm on the medial opening of the hearing aid. Nine hearing-impaired persons with a high-frequency hearing loss participated. The test battery included unaided in situ thresholds, amount of available gain before feedback, speech in quiet, speech in noise (HINT), subjective ratings of hollowness and tolerance, objective measures of the occlusion effect, and real-ear aided response. Results showed less available gain before feedback but less occlusion effect for subjective ratings and objective measures with the reverse horn vent. This type of vent design may be useful to increase the effective vent diameter of custom (including CIC) hearing aids.


1980 ◽  
Vol 89 (5_suppl) ◽  
pp. 79-83
Author(s):  
Richard Lippmann

Following the Harvard master hearing aid study in 1947 there was little research on linear amplification. Recently, however, there have been a number of studies designed to determine the relationship between the frequency-gain characteristic of a hearing aid and speech intelligibility for persons with sensorineural hearing loss. These studies have demonstrated that a frequency-gain characteristic that rises at a rate of 6 dB/octave, as suggested by the Harvard study, is not optimal. They have also demonstrated that high-frequency emphasis of 10–40 dB above 500–1000 Hz is beneficial. Most importantly, they have demonstrated that hearing aids as they are presently being fit do not provide maximum speech intelligibility. Percent word correct scores obtained with the best frequency-gain characteristics tested in various studies have been found to be 9 to 19 percentage points higher than scores obtained with commercial aids owned by subjects. This increase in scores is equivalent to an increase in signal-to-noise ratio of 10 to 20 dB. This is a significant increase which could allow impaired listeners to communicate in many situations where they presently cannot. These results demonstrate the need for further research on linear amplification aimed at developing practical suggestions for fitting hearing aids.


2013 ◽  
Vol 24 (10) ◽  
pp. 980-991 ◽  
Author(s):  
Kristi Oeding ◽  
Michael Valente

Background: In the past, bilateral contralateral routing of signals (BICROS) amplification incorporated omnidirectional microphones on the transmitter and receiver sides and some models utilized noise reduction (NR) on the receiver side. Little research has examined the performance of BICROS amplification in background noise. However, previous studies examining contralateral routing of signals (CROS) amplification have reported that the presence of background noise on the transmitter side negatively affected speech recognition. Recently, NR was introduced as a feature on the receiver and transmitter sides of BICROS amplification, which has the potential to decrease the impact of noise on the wanted speech signal by decreasing unwanted noise directed to the transmitter side. Purpose: The primary goal of this study was to examine differences in the reception threshold for sentences (RTS in dB) using the Hearing in Noise Test (HINT) in a diffuse listening environment between unaided and three aided BICROS conditions (no NR, mild NR, and maximum NR) in the Tandem 16 BICROS. A secondary goal was to examine real-world subjective impressions of the Tandem 16 BICROS compared to unaided. Research Design: A randomized block repeated measures single blind design was used to assess differences between no NR, mild NR, and maximum NR listening conditions. Study Sample: Twenty-one adult participants with asymmetric sensorineural hearing loss (ASNHL) and experience with BICROS amplification were recruited from Washington University in St. Louis School of Medicine. Data Collection and Analysis: Participants were fit with the National Acoustic Laboratories’ Nonlinear version 1 prescriptive target (NAL-NL1) with the Tandem 16 BICROS at the initial visit and then verified using real-ear insertion gain (REIG) measures. Participants acclimatized to the Tandem 16 BICROS for 4 wk before returning for final testing. Participants were tested utilizing HINT sentences examining differences in RTS between unaided and three aided listening conditions. Subjective benefit was determined via the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire between the Tandem 16 BICROS and unaided. A repeated measures analysis of variance (ANOVA) was utilized to analyze the results of the HINT and APHAB. Results: Results revealed no significant differences in the RTS between unaided, no NR, mild NR, and maximum NR. Subjective impressions using the APHAB revealed statistically and clinically significant benefit with the Tandem 16 BICROS compared to unaided for the Ease of Communication (EC), Background Noise (BN), and Reverberation (RV) subscales. Conclusions: The RTS was not significantly different between unaided, no NR, mild NR, and maximum NR. None of the three aided listening conditions were significantly different from unaided performance as has been reported for previous studies examining CROS hearing aids. Further, based on comments from participants and previous research studies with conventional hearing aids, manufacturers of BICROS amplification should consider incorporating directional microphones and independent volume controls on the receiver and transmitter sides to potentially provide further improvement in signal-to-noise ratio (SNR) for patients with ASNHL.


2018 ◽  
Vol 27 (1) ◽  
pp. 95-103
Author(s):  
Adriana Goyette ◽  
Jeff Crukley ◽  
Jason Galster

Purpose Directional microphone systems are typically used to improve hearing aid users' understanding of speech in noise. However, directional microphones also increase internal hearing aid noise. The purpose of this study was to investigate how varying directional microphone bandwidth affected listening preference and speech-in-noise performance. Method Ten participants with normal hearing and 10 participants with hearing impairment compared internal noise levels between hearing aid memories with 4 different microphone modes: omnidirectional, full directional, high-frequency directionality with directional processing above 900 Hz, and high-frequency directionality with directional processing above 2000 Hz. Speech-in-noise performance was measured with each memory for the participants with hearing impairment. Results Participants with normal hearing preferred memories with less directional bandwidth. Participants with hearing impairment also tended to prefer the memories with less directional bandwidth. However, the majority of participants with hearing impairment did not indicate a preference between omnidirectional and directional above 2000 Hz memories. Average hearing-in-noise performance improved with increasing directional bandwidth. Conclusions Most participants preferred memories with less directional bandwidth in quiet. Participants with hearing impairment indicated no difference in preference between directional above 2000 Hz and the omnidirectional memories. Speech recognition in noise performance improved with increasing directional bandwidth.


2002 ◽  
Vol 116 (S28) ◽  
pp. 29-36 ◽  
Author(s):  
Ann-Louise McDermott ◽  
Sunil N. Dutt ◽  
Elia Tziambazis ◽  
Andrew P. Reid ◽  
David W. Proops

The Birmingham bone-anchored hearing aid programme began in 1988 and by autumn 2000 a total of 351 patients had been fitted with such an aid. The aim of this study was to assess the effectiveness of hearing rehabilitation with the bone-anchored hearing aid. This was a prospective interview-based questionnaire study carried out in the autumn 2000. A total of 84 adult patients were interviewed. Each patient had worn their BAHA for more than one year.The questionnaire used during these interviews was the Glasgow hearing aid benefit profile (GHABP) and the Glasgow hearing aid difference profile (GHADP). This was first derived and validated by Gatehouse in 1999. The use of bone-anchored hearing aids was found to reduce the level of disability and handicap and provided the most patient benefit and satisfaction.


2019 ◽  
Vol 62 (11) ◽  
pp. 4150-4164 ◽  
Author(s):  
Inge de Ronde-Brons ◽  
Wim Soede ◽  
Wouter Dreschler

Purpose The aim of the study was to evaluate the application of a modified version of the Amsterdam Inventory for Auditory Disabilities and Handicap to inventory self-reported hearing difficulties pre and post hearing aid fitting in 6 dimensions: detection, speech in silence, speech in noise, localization, discrimination, and noise tolerance. Method Questionnaires pre and post hearing aid fitting were collected during regular practice of hearing aid provision. Data of 740 subjects are presented; 337 already used hearing aids, and 403 were new users. Results Group-averaged scores improved due to hearing aid fitting for all 6 dimensions. Based on a criterion previously defined for the Amsterdam Inventory for Auditory Disabilities and Handicap questionnaire, 66% of subjects had a significant individual improvement in sum score. Experienced users showed lower improvement in scores, whereas their aided prescores were, on average, not better than the (unaided) score of 1st users. Conclusions The questionnaire can be applied as a structured approach to inventory hearing problems in 6 dimensions prior to hearing aid fitting and to systematically evaluate the effects of hearing aid fitting after a trial period. The data presented here can serve as normative data for comparison of individual subjects in clinical practice.


2021 ◽  
Vol 13 (1) ◽  
pp. 5-8
Author(s):  
Douglas L Beck

Hearing aids have undergone vast changes in the last 30 years from basic analog sound processing techniques, to advanced digital technology, to Deep Neural Networks (DNNs) “on-the-chip” providing real-time sound processing. In addition to making sounds audible, advanced hearing aids with DNN on-the-chip are better able to provide clearer understanding of speech in noise, improve recall, maintain interaural loudness and timing differences, and improve the wearer’s ability to selectively attend to the speaker of choice in challenging listening situations. These improvements are delivered without acoustic feedback and with very high sound quality.


Sign in / Sign up

Export Citation Format

Share Document