scholarly journals Thumb Proprioception in Hypermobile and Non-Hypermobile Adults: An Observational Study

2021 ◽  
Vol 2 (2) ◽  
Author(s):  
Leon Fonseka ◽  
Nicola Massy-Westropp ◽  
Steve Milanese ◽  
Arjun Burlakoti

Aims and Background Hypermobility is a common presentation in the community and is reported related to higher rates of injury and musculoskeletal pain, however the mechanism underpinning this relationship remains unclear. Poor proprioception in hypermobile joints has been proposed as a potential mechanism. This study aims to determine if there is a difference in proprioceptive acuity, as measured by joint position reproduction, in adults with generalised joint hypermobility. Design and methods A convenience sample of 26 university students and staff (mean age 29.23 years, range 18-47) were recruited, of which 12 participants displayed generalised joint hypermobility, and 14 did not. A laser light, mounted to the dominant thumb, was used to test joint position reproduction sense by pointing to targets using a unilateral active-active position reproduction protocol. Results/Findings Test reliability across a range of targets was poor to good (intraclass correlation coefficients ranged from 0.1163 to 0.7256), indicating significant variability between participants. No significant differences was found in absolute angle of error between generalised joint hypermobility and non-generalised joint hypermobility participants. For direction of error in relation to the proprioceptive targets, only 30° thumb extension above horizontal was found to be significantly different between the hypermobile and non-hypermobile groups, with hypermobile participants tending to underestimate distance to target. Age and sex were not correlated to thumb proprioception. Application and Conclusion The difference found in direction of error and tendency to underestimate angular distance may be protective against straying into possibly injurious end-ranges; however, larger studies are recommended to confirm this.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Minjeong Kim ◽  
Ja Young Oh ◽  
Seon Ha Bae ◽  
Seung Hyeun Lee ◽  
Won Jun Lee ◽  
...  

AbstractWe evaluated the reliability and validity of the 5-scale grading system to interpret the point-of-care immunoassay for tear matrix metalloproteinase (MMP)-9. Six observers graded red bands of photographs of the readout window in MMP-9 immunoassay kit (InflammaDry) two times with 2-week interval based on the 5-scale grading system (i.e. grade 0–4). Interobserver and intraobserver reliability were evaluated using intraclass correlation coefficients. The interobserver agreements were analyzed according to the severity of tear MMP-9 expression. To validate the system, a concentration calibration curve was made using MMP-9 solutions with reference concentrations, then the distribution of MMP-9 concentrations was analyzed according to the 5-scale grading system. Both intraobserver and interobserver reliability was excellent. The readout grades were significantly correlated with the quantified colorimetric densities. The interobserver variance of readout grades had no correlation with the severity of the measured densities. The band density continued to increase up to a maximal concentration (i.e. 5000 ng/mL) according to the calibration curve. The difference of grades reflected the change of MMP-9 concentrations sensitively, especially between grade 2 and 4. Together, our data indicate that the subjective 5-scale grading system in the point-of-care MMP-9 immunoassay is an easy and reliable method with acceptable accuracy.


2020 ◽  
Vol 127 (4) ◽  
pp. 671-683
Author(s):  
João P. Nunes ◽  
Paolo M. Cunha ◽  
Jerry L. Mayhew ◽  
Alex S. Ribeiro ◽  
Paulo S. Junior ◽  
...  

The present study aimed to evaluate the influence of holding the chair handles during the assessment of older women’s knee flexion and extension isokinetic and isometric strength. Of 57 older women (≥60 years) selected from a convenience sample for this research, 23 were randomly chosen to perform the tests twice for reliability analyses. Each participant performed maximal isokinetic knee extension and flexion at 60°/s and 180°/s angular velocities and isometric tests under two conditions: (a) holding the lateral handle of the chair (HOLD) and (b) supporting the hands on the shoulders with the arms crossed (i.e., not holding the handle [NHOLD]). Participants performed significantly better in the HOLD compared with the NHOLD condition. Slightly lower intraclass correlation coefficients (ICC = 0.870–0.956) were noted for the HOLD than for the NHOLD condition (ICC = 0.900–0.981) so that the HOLD performance on Days 1 and 2 was different on some measures. Owing to the higher reliability coefficients in the NHOLD condition, results suggest that, when assessing knee strength in older women, the evaluee should place their hands over their shoulders with arms crossed in front of the chest (NHOLD) to maximize assessment reliability (reproducibility of performance).


2016 ◽  
Vol 86 (6) ◽  
pp. 1004-1009 ◽  
Author(s):  
Asli Baysal ◽  
Ahmet Oguz Sahan ◽  
Mehmet Ali Ozturk ◽  
Tancan Uysal

ABSTRACT Objective: To evaluate the intraexaminer repeatability and interexaminer reproducibility of soft tissue landmarks on three-dimensional (3-D) stereophogrammetric images. Materials and Methods: Thirty-four stereophotogrammetric images were taken and 19 soft tissue points were identified. The images were obtained using the 3-DMD Face (3-DMD TM Ltd, Atlanta, Ga) system. Two examiners marked 34 images manually with a mouse-driven cursor 4 weeks apart. Intraexaminer marking differences were calculated and classified as <0.5 mm, 0.5–1 mm, and >1 mm. Intraclass correlation coefficients were calculated for intraexaminer reliability. A paired-samples t-test was used to evaluate the difference between the examiners. Interexaminer reproducibility was evaluated by kappa analysis. Statistical significance was set at P < .05. Results: Only one landmark (labiale superior) had an intraexaminer marking difference less than 0.5 mm. Existing landmarks had an intraexaminer difference less than 1 mm, but higher than 0.5 mm. The intraclass correlation coefficients (ICCs) indicated good intraexaminer repeatability for both observers. The ICC range for examiners 1 and 2 was 0.986–1.000 and 0.990–1.000, respectively. Kappa scores showed good interexaminer agreement, especially on the z-axis. Conclusions: Except labiale superior, the soft tissue landmarks used in this study were shown to have moderate reproducibility, but the difference between the landmarks was less than 1 mm, and they had clinically acceptable reproducibility.


2020 ◽  
Author(s):  
YU Song ◽  
Panpan Li ◽  
Yuanyuan Tu ◽  
Ying Wu ◽  
Lili Huang ◽  
...  

Abstract Purpose To assess accuracy of OPD-Scan III in measuring keratometry, astigmatism and axis in patients with cataract and moderate to high astigmatism Materials and Methods Measurements were taken with OPD-Scan III and Pentacam in cataract patients with keratometric astigmatism (KA) more than 0.75 D. Keratometry in the steepest axis (Ks) and flattest axis (Kf), KA and axis, which are power vector components of astigmatism (J0 and J45), were evaluated. Intraclass correlation coefficients (ICCs) were used to assess repeatability. The Wilcoxon test was used to assess differences, the Spearman correlation was used to assess correlations, and the Bland-Altman method was used to assess agreement. Results Seventy eyes of 63 patients were included to analyze the repeatability of the two devices. The ICCs of Ks, Kf, KA, axis, J0 and J45 were 0.991, 0.995, 0.946, 0.883, 0.946 and 0.892, respectively, with OPD-Scan III. Seven hundred and thirty-two eyes of 516 patients were included to analyze the difference, correlation and agreement of the two devices. There were significant differences between the two devices in terms of Ks, Kf, axis, J0 and J45 (all p < 0.01). There were significant correlations between the two devices in each parameter (all p < 0.01). The 95% limits of agreement (LOAs) for Ks, Kf, KA, astigmatic axis, J0 and J45 were (-0.34, 0.44) D, (-0.24, 0.38) D, (-0.46, 0.48) D, (-10.20, 12.92)°, (-0.24, 0.24) D, and (-0.27, 0.35) D respectively.The 95% LOAs for the degree of IOL caculated according to parameter measured by OPD-Scan III and Pentacam was (-0.32, 0.22) D. Conclusions OPD-Scan III has a high accuracy for measuring keratometry, but its accuracy for measuring astigmatism and axis is poor in eyes with moderate to high astigmatism.


2019 ◽  
Vol 14 (4) ◽  
pp. 472-477 ◽  
Author(s):  
Kathryn E. Phillips ◽  
Will G. Hopkins

Purpose: To further the understanding of elite athlete performance in complex race environments by examining the changes in cyclists’ performance between solo time trials and head-to-head racing in match-sprint tournaments. Methods: Analyses were derived from official results of cyclists in 61 elite international sprint tournaments (2000–2016), incorporating the results of 2060 male and 1969 female head-to-head match races. Linear mixed modeling of log-transformed qualification and finish ranks was used to determine estimates of performance predictability as intraclass correlation coefficients. Correlations between qualifying performance and final tournament rank were also calculated. Chances of winning head-to-head races were estimated adjusting for the difference in the cyclists’ qualifying times. All effects were evaluated using magnitude-based inference. Results: Minor differences in predictability between qualification time trial and final tournament rank were suggestive of more competitiveness among men in the overall tournament. Performance in the qualification time trial was strongly correlated with, but not fully indicative of, performance in the overall tournament. Correspondingly, being the faster qualifier had a large positive effect on the chances of winning a head-to-head race, but small substantial differences between riders remained after adjustment for time-trial differentials. Conclusions: The present study provides further insight into how real-world competition data can be used to investigate elite athlete performance in sports where athletes must directly interact with their opponents. For elite match-sprint cyclists, qualifying time-trial performance largely determines success in the overall tournament, but there is evidence of a consistent match-race ability that modifies the chances of winning head-to-head races.


Author(s):  
Munenori Murata ◽  
Hiroo Takahashi

TrackMan, a device used to measure the kinematics of a ball in flight, has recently been used for research and coaching purposes in tennis, and the number of studies on this device is expected to increase. This study is focused on verifying the accuracy of TrackMan; three participants performed services with various velocities and angular velocity combinations. TrackMan and a proven method based on computer vision were used to measure the speed, spin rate, and spin axis of the ball. The results obtained using each method were compared using regression analysis, intraclass correlation coefficients, and Bland–Altman analysis. The speed and spin rate of the two methods agreed well; the degree of error would not be problematic in practical applications. However, TrackMan underestimated the speed if it was unable to detect the hitting position. The spin axis measured by TrackMan was unstable under low spin rate conditions (<3000 rpm). Furthermore, the standard deviation of the spin axis measurement error exceeded the difference between the average slice and kick service spin axes reported in the previous study, so the spin axis measurement accuracy was very low for research purposes, even when the spin rate was above 3000 rpm. For those who are aware of the existence of outliers, TrackMan can be useful for coaching because it provides instant feedback. Similarly, the measured rotational speed and spin rate could be used in the study.


2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Alireza Zandifar ◽  
Samaneh Sadat Masjedi ◽  
Faraidoon Haghdoost ◽  
Fatemeh Asgari ◽  
Navid Manouchehri ◽  
...  

Background. Migraine-specific quality of life (MSQ) is a valid and reliable questionnaire. Linguistic validation of Persian MSQ questionnaire, analysis of psychometric properties between chronic and episodic migraine patients, and capability of MSQ to differentiate between chronic and episodic migraines were the aims of this study.Method. Participants were selected from four different neurology clinics that were diagnosed as chronic or episodic migraine patients. Baseline data included information from MSQ v. 2.1, MIGSEV, SF-36, and symptoms questionnaire. At the third week from the baseline, participants filled out MSQ and MIGSEV. Internal consistency (Cronbach alpha) and test-retest reproducibility (intraclass correlation coefficients) were used to assess reliability. Convergent and discriminant validities were also assessed.Results. A total of 106 participants were enrolled. Internal consistencies of MSQ among all patients, chronic and episodic migraines, were 0.92, 0.91, and 0.92, respectively. Test-retest correlation of MSQ dimensions between visits 1 and 2 varied from 0.41 to 0.50. Convergent, item discriminant, and discriminant validities were approved. In all visits MSQ scores were lower in chronic migraine than episodic migraine; however, the difference was not statistically significant.Conclusion. Persian translation of MSQ is consistent with original version of MSQ in terms of psychometric properties in both chronic and episodic migraine patients.


1991 ◽  
Vol 34 (5) ◽  
pp. 989-999 ◽  
Author(s):  
Stephanie Shaw ◽  
Truman E. Coggins

This study examines whether observers reliably categorize selected speech production behaviors in hearing-impaired children. A group of experienced speech-language pathologists was trained to score the elicited imitations of 5 profoundly and 5 severely hearing-impaired subjects using the Phonetic Level Evaluation (Ling, 1976). Interrater reliability was calculated using intraclass correlation coefficients. Overall, the magnitude of the coefficients was found to be considerably below what would be accepted in published behavioral research. Failure to obtain acceptably high levels of reliability suggests that the Phonetic Level Evaluation may not yet be an accurate and objective speech assessment measure for hearing-impaired children.


Author(s):  
Marcos A Soriano ◽  
G Gregory Haff ◽  
Paul Comfort ◽  
Francisco J Amaro-Gahete ◽  
Antonio Torres-González ◽  
...  

The aims of this study were to (I) determine the differences and relationship between the overhead press and split jerk performance in athletes involved in weightlifting training, and (II) explore the magnitude of these differences in one-repetition maximum (1RM) performances between sexes. Sixty-one men (age: 30.4 ± 6.7 years; height: 1.8 ± 0.5 m; body mass 82.5 ± 8.5 kg; weightlifting training experience: 3.7 ± 3.5 yrs) and 21 women (age: 29.5 ± 5.2 yrs; height: 1.7 ± 0.5 m; body mass: 62.6 ± 5.7 kg; weightlifting training experience: 3.0 ± 1.5 yrs) participated. The 1RM performance of the overhead press and split jerk were assessed for all participants, with the overhead press assessed on two occasions to determine between-session reliability. The intraclass correlation coefficients (ICC) and 95% confidence intervals showed a high reliability for the overhead press ICC = 0.98 (0.97 – 0.99). A very strong correlation and significant differences were found between the overhead press and split jerk 1RM performances for all participants (r = 0.90 [0.93 – 0.85], 60.2 ± 18.3 kg, 95.7 ± 29.3 kg, p ≤ 0.001). Men demonstrated stronger correlations between the overhead press and split jerk 1RM performances (r = 0.83 [0.73-0.90], p ≤ 0.001) compared with women (r = 0.56 [0.17-0.80], p = 0.008). These results provide evidence that 1RM performance of the overhead press and split jerk performance are highly related, highlighting the importance of upper-limb strength in the split jerk maximum performance.


Dysphagia ◽  
2021 ◽  
Author(s):  
Sofie Albinsson ◽  
Lisa Tuomi ◽  
Christine Wennerås ◽  
Helen Larsson

AbstractThe lack of a Swedish patient-reported outcome instrument for eosinophilic esophagitis (EoE) has limited the assessment of the disease. The aims of the study were to translate and validate the Eosinophilic Esophagitis Activity Index (EEsAI) to Swedish and to assess the symptom severity of patients with EoE compared to a nondysphagia control group. The EEsAI was translated and adapted to a Swedish cultural context (S-EEsAI) based on international guidelines. The S-EEsAI was validated using adult Swedish patients with EoE (n = 97) and an age- and sex-matched nondysphagia control group (n = 97). All participants completed the S-EEsAI, the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire-Oesophageal Module 18 (EORTC QLQ-OES18), and supplementary questions regarding feasibility and demographics. Reliability and validity of the S-EEsAI were evaluated by Cronbach’s alpha and Spearman correlation coefficients between the domains of the S-EEsAI and the EORTC QLQ-OES18. A test–retest analysis of 29 patients was evaluated through intraclass correlation coefficients. The S-EEsAI had sufficient reliability with Cronbach’s alpha values of 0.83 and 0.85 for the “visual dysphagia question” and the “avoidance, modification and slow eating score” domains, respectively. The test–retest reliability was sufficient, with good to excellent intraclass correlation coefficients (0.60–0.89). The S-EEsAI domains showed moderate correlation to 6/10 EORTC QLQ-OES18 domains, indicating adequate validity. The patient S-EEsAI results differed significantly from those of the nondysphagia controls (p < 0.001). The S-EEsAI appears to be a valid and reliable instrument for monitoring adult patients with EoE in Sweden.


Sign in / Sign up

Export Citation Format

Share Document