scholarly journals A novel spectrophotometric method development and validation of Tenagliptin in its Tablet dosages form

2019 ◽  
Vol 9 (5) ◽  
pp. 95-98
Author(s):  
Poulami Patra ◽  
Somsubhra Ghosh ◽  
Tathagata Roy ◽  
B. V. V. Ravi kumar

The aim of present work was to develop a new, economical & simple analytical method of Teneligliptin & its validation as per International Conference on Harmonization (ICH) guideline, which is a new antidiabetic drug that is used to treat Non-Insulin Dependent Diabetis Melitus (NIDDM) patients. A sensitive and specific Ultra Violet (UV) Visible method was developed & the analysis was carried out by using Shimazdu 1800 Spectrophotometer, 0.1(N) NaOH was used as a solvent. The UV- Visible Spectrophotometric estimation was carried out at a λ max of 242 nm using 1cm thick quartz cell. Validation of the newly developed method was performed as per International Conference on Harmonization (ICH) Q2R1 guideline in the following parameters: Calibration curve, Accuracy, Precision etc.  Newly developed method obeys Beer’s-Lambert’s law in the concentration range of 5 - 25 μg / ml, whereas correlation coefficient value is less than 1. The percent amount of drug estimated by this developed method was 100.91 %, which is very close to 100 %. The validation parameters like Accuracy, Precision, Linearity, Range, Limit of detection (LOD) & Limit of Quantification (LOQ) were studied for the developed method and was found to be within the limits. Keywords: Teneligliptin, Validation, Method, Spectroscopy etc.

2020 ◽  
Vol 10 (6) ◽  
pp. 49-56
Author(s):  
Sneha Jagnade ◽  
Pushpendra Soni ◽  
Lavakesh Kumar Omray

The aim of present study was to investigate the development and validation of a green analytical method for the determination of aspirin and domperidone. Method Development and Validation for Estimation of Domperidone and Aspirin in bulk or formulation by using RP-HPLC. The RP-HPLC method was developed for estimation of Aspirin and Domperidone in synthetic mixture by isocratically using 10 mM KH2PO4: Acetonitrile (20:80) as mobile phase, Prontosil C-18 column (4.6 x 250 mm, 5μparticle size) column as stationary phase and chromatogram was recorded at 231 nm. Then developed method was validated by using various parameters such as, linearity, Range accuracy, precision repeatability, intermediate precision, robustness, limit of detection, limit of quantification. The proposed methods were found to be linear with correlation coefficient close to one. Precision was determined by repeatability, Intermediate precision and reproducibility of the drugs. The robustness of developed method was checked by changing in the deliberate variation in solvent. The result obtained shows the developed methods to be Cost effective, Rapid (Short retention time), Simple, Accurate (the value of SD and % RSD less than 2), Precise and can be successfully employed in the routine analysis of these drugs in bulk drug as well as in tablet dosage form. The Simplicity, Rapidly and Reproducibility of the proposed method completely fulfill the objective of this research work. Keywords: Asprin; Domperidone; HPLC; Ultra Violet; Validation


Drug Research ◽  
2020 ◽  
Vol 70 (09) ◽  
pp. 417-423
Author(s):  
Beena Kumari ◽  
Aparna Khansili

Abstract Background Vildagliptin is an antidiabetic agent, belongs to the dipeptidyl peptidase IV (DPP-4) inhibitors. Objective The aim of investigation was to develop a simple UV-visible Spectrophotometric method for the determination of vildagliptin in its pure form and pharmaceutical formulations, further to validate the developed method. Material and Methods Vildagliptin was estimated using UV-Visible double beam spectrophotometer at the wavelength of maximum absorption (210 nm) in acidic medium containing 0.1N HCl. The drug was characterized by melting point, Differential Scanning Calorimetry (DSC), and Fourier Transform Infra-Red (FTIR) techniques. The analysis of the drug was carried out by novel UV-Visible method which was validated analytical parameters like linearity, precision, and accuracy as per guidelines laid down by International Conference on Harmonization (ICH). Result Melting point of drug was found 154°C which is corresponds to its actual melting range. Similarly by the interpretation of spectra the drug was confirmed. The linear response for concentration range of 5–60 µg/ml of vildagliptin was recorded with regression coefficient 0.999. The accuracy was found between 98–101%. Precision for intraday and interday was found to be 1.263 and 1.162 respectively, which are within the limits. To establish the sensitivity of the method, limit of detection (LOD) and limit of quantification (LOQ) were determined which were found to be 0.951 µg/ml and 2.513 µg/ml respectively. Conclusion The UV method developed and validated for vildagliptin drug was found to be linear, accurate, precise and economical which can be used for the testing of its pharmaceutical formulations.


Author(s):  
Ayya Rajendra Prasad ◽  
Jayanthi Vijaya Ratna

 Objective: The objective of this study was developed and validated a novel, specific, precise, and simple ultraviolet (UV)-spectrophotometric method for the estimation of norfloxacin present in taste masked drug-resin complex.Methods: UV-spectrophotometric determination was performed with ELICO SL 1500 UV-visible spectrophotometer using 0.1 N HCl as a medium. The spectrum of the standard solution was run from 200 to 400 nm range for the determination of absorption maximum (λ max). λ max of norfloxacin was found at 278 nm. The absorbance of standard solutions of 1, 2, 3, 4, and 5 μg/ml of drug solution was measured at an absorption maximum at 278 nm against the blank. Then, a graph was plotted by taking concentration on X-axis and absorbance on Y-axis which gave a straight line. Validation parameters such as linearity and range, selectivity and specificity, limit of detection (LOD) and limit of quantification (LOQ), accuracy, precision, and robustness were evaluated as per the International Conference on Harmonization (ICH) guidelines.Results: Linearity for the UV-spectrophotometric method was noted over a concentration range of 1–5 μg/ml with a correlation coefficient of 0.9995. The LOD and LOQ for norfloxacin were found at 0.39 μg/ml and 1.19 μg/ml, respectively. Accuracy was in between 99.00% and 99.17%. % relative standard deviation for repeatability, intraday precision, and interday precision was found to be 0.600, in between 0.291 and 0.410, and in between 0.682 and 1.439, respectively. The proposed UV spectrophotometric method is found to be robust.Conclusion: The proposed UV-spectrophotometric method was validated according to the ICH guidelines, and results and statistical parameters demonstrated that the developed method is sensitive, precise, reliable, and simple for the estimation of norfloxacin present in taste masked drug-resin complex.


2019 ◽  
Vol 31 (1) ◽  
pp. 32-39
Author(s):  
Suman Shrivastava ◽  
Pooja Deshpande ◽  
S. J. Daharwal

Development of a method is crucial for discovery, development, and analysis of medicines in the pharmaceutical formulation. Method validation could also be thought to be one in all the foremost well-known areas in analytical chemistry as is reproduced within the substantial variety of articles submitted and presented in peer review journals every year. Validation of an analytical procedure is to demonstrate that it's appropriate for its intended purpose. Results from method validation are often wont to decide the quality, reliability and consistency of analytical results. Analytical methods need to be validated or revalidated. This review describes general approach towards validation process and validation parameters to be considered during validation of an analytical method. It also refers to various regulatory requirements like WHO, USFDA, EMEA, ICH, ISO/IEC. The parameters described here are according to ICH guidelines which include accuracy, precision, specificity, limit of detection, limit of quantification, linearity range and robustness.


Author(s):  
Alok Pratap Singh ◽  
Iti Chauhan ◽  
Snigdha Bhardwaj ◽  
Praveen Gaur ◽  
S Sadish Kumar ◽  
...  

Introduction: Azithro-mycin a semi-synthetic, azalide congener of erythro-mycin indicated in the treatment of respiratory tract infections. Various methods available for determination of Azithro-mycin, but HPLC are most versatile one. Objective: The present study is based on the development and validation of a rapid, simple high performance liquid chromatography (HPLC) method equipped with UV detector for quantitative analysis of Azithro-mycin (AZN) in suspension. Material and methods: The Method was performed by using Hypersil BDS-C18 (250 mm × 4.6 mm i.d.) column MS-II, with an isocratic mobile phase of methanol, acetonitrile and phosphate buffer pH 8 (60:30:10; v/v) with run time 15 minutes. The determinations were performed at a flow rate of 1.0ml/min, and UV detector set at 212 nm. Result and Discussion: The method was found to be specific with relative standard deviation (RSD) less than 2.09%. The method showed accuracy with RSD less than 1.34% and precision in repeatability with RSD less than 1.42%. The method was found to be linear over a wide range of concentration from 1.0 to 50.0 μg/mL (R2 = .995). Limit of detection and limit of quantification were found to be 14.40 ng/mL and 43.66 ng/mL respectively. Conclusion: It was advantageous to use UV detector over other methods employing electrochemical, photodiode array etc. as the detector, because of cheap and easy availability. The developed method fulfilled all validation parameters as per ICH and can be successfully applied to quantify percent drug content in marketed oral Azithro-mycin suspension.


2018 ◽  
Vol 10 (1) ◽  
pp. 74 ◽  
Author(s):  
Ayya Rajendra Prasad ◽  
Bannaravuri Thireesha

Objective: To develop and validate a novel, specific, precise and simple UV-spectrophotometric method for the estimation of lornoxicam present in microsponges.Methods: UV-spectrophotometric determination was performed with Thermo Scientific Evolution 201 UV-Vis spectrophotometer using methanol as a medium. The spectrum of the standard solution was run from 200-400 nm range for the determination of absorption maximum (λ max). λ max of lornoxicam was found at 353 nm. The absorbance of standard solutions of 3, 6, 9, 12 and 15, µg/ml of drug solution was measured at an absorption maximum at 353 nm against the blank. Then a graph was plotted by taking concentration on X-axis and absorbance on Y-axis which gave a straight line. Validation parameters such as linearity and range, selectivity and specificity, LOD and LOQ, accuracy, precision and robustness were evaluated as per ICH guidelines.Results: Linearity for the UV-spectrophotometric method was noted over a concentration range of 3.0-15.0 µg/ml with a correlation coefficient of 0.9995. The limit of detection (LOD) and limit of quantification (LOQ) for lornoxicam was found at 1.26 μg/ml and 3.82 μg/ml respectively. Accuracy was in between 99.21 and 99.60%. % RSD for repeatability, intraday precision and interday precision were found to be 0.473, in between 0.478 and 0.619 and in between 0.855 and 1.818 respectively. The proposed UV method is found to be robust.Conclusion: The proposed UV-Visible spectrophotometric method was validated according to the ICH guidelines and results and statistical parameters demonstrated that the developed method is sensitive, precise, reliable and simple for the estimation of lornoxicam present in microsponges.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Indhu Priya Mabbu ◽  
G. Sumathi ◽  
N. Devanna

Abstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl sulfone was achieved by the Symmetry C18 (50 × 4.6 mm, 3.5 μm) column and a mobile phase composition of 0.1%v/v ammonia buffer to methanol (5:95 v/v), using 0.45 ml/min flow rate and 20 μl of injection volume, with methanol used as diluent. The phenyl vinyl sulfone was monitored on atomic pressure chemical ionization mode mass spectrometer with positive polarity mode. Results The retention time of phenyl vinyl sulfone was found at 2.13 min. The limit of detection (LOD) and limit of quantification (LOQ) were observed at 1.43 ppm and 4.77 ppm concentration respectively; the linear range was found in the concentration ranges from 4.77 to 27.00 ppm with regression coefficient of 0.9990 and accuracy in the range of 97.50–102.10%. The percentage relative standard deviation (% RSD) for six replicates said to be injections were less than 10%. Conclusion The proposed method was validated successfully as per ICH guidelines. Hence, this is employed for the determination of phenyl vinyl sulfone in the eletriptan hydrobromide.


Author(s):  
Pushpa Latha E. ◽  
Sailaja B.

Analytical UV derivative spectrophotometric method was developed and validated to quantify Rizatriptan Benzoate in pure drug and tablet dosage form. Based on the spectrophotometric characteristics of Rizatriptan Benzoate, a signal of zero (225nm), first (216nm), second (237nm), third (233nm), fourth (231nm) order derivative spectra were found to be adequate for quantification. The methods obeyed Beer's law in the concentration range of (0.1-360µg/ml) with square correlation coefficient (r2) of 0.999. The mean percentage recovery was found to be 100.01 ± 0.075. As per ICH guidelines the results of the analysis were validated in terms of linearity, precision, accuracy, limit of detection and limit of quantification, and were found to be satisfactory.


2021 ◽  
pp. 1-11
Author(s):  
Sultan M. Alshahrani ◽  
John Mark Christensen

This study was designed to develop and validate a simple and efficient high performance liquid chromatography (HPLC) method to determine flunixin concentrations in Asian elephant’s (Elephas maximus) plasma. Flunixin was administered orally at a dose of 0.8 mg/kg, and blood samples were collected. Flunixin extraction was performed by adding an equal amount of acetonitrile to plasma and centrifuging at 4500 rpm for 25 minutes. The supernatant was removed, and flunixin was analyzed using HPLC-UV detection. Two methods were developed and tested utilizing two different mobile phases either with or without adding methanol (ACN: H2O vs. ACN: H2O: MeOH). Both methods showed excellent linearity and reproducibility. The limit of detection was 0.05 ug/ml and limit of quantification was 0.1 ug/ml. the efficiency of flunixin recovery was maximized by the addition of methanol to mobile phase (ACN: H2O: MeOH as 50:30:20) at 95% in comparison to 23% without methanol. In conclusion, adding methanol to HPLC methods for extraction of flunixin from elephants’ plasma yielded higher recovery rate than without methanol.


2017 ◽  
Vol 9 (5) ◽  
pp. 102
Author(s):  
Sukhjinder Kaur ◽  
Taranjit Kaur ◽  
Gurdeep Kaur ◽  
Shivani Verma

Objective: The aim of the present work was to develop a simple, rapid, accurate and economical UV-visible spectrophotometric method for the determination of hydroquinone (HQ) in its pure form, marketed formulation as well as in the prepared nanostructured lipid carrier (NLC) systems and to validate the developed method.Methods: HQ was estimated at UV maxima of 289.6 nm in pH 5.5 phosphate buffer using UV-Visible double beam spectrophotometer. Following the guidelines of the International Conference on Harmonization (ICH), the method was validated for various analytical parameters like linearity, precision, and accuracy robustness, ruggedness, limit of detection, quantification limit, and formulation analysis.Results: The obtained results of the analysis were validated statistically. Recovery studies were performed to confirm the accuracy of the proposed method. In the developed method, linearity over the concentration range of 5-40 μg/ml of HQ was observed with the correlation coefficient of 0.998 and found in good agreement with Beer Lambert’s law. The precision (intra-day and inter-day) of the method was found within official RCD limits (RSD<2%).Conclusion: The sensitivity of the method was assessed by determining the limit of detection and limit of quantification. It could be concluded from the results obtained that the purposed method for estimation of HQ in pure form, in the marketed ointment and in the prepared NLC-formulation was simple, rapid, accurate, precise and economical. It can be used successfully in the quality control of pharmaceutical formulations and for the routine laboratory analysis.