scholarly journals Modified Nanodiamonds as a New Carrier for Developing Reusable Enzymatic Test-Systems for Determination of Physiologically Important Substances

2018 ◽  
Vol 2 (2) ◽  
pp. 7-17 ◽  
Author(s):  
Nikita Ronzhin ◽  
◽  
Alexey Baron ◽  
Alexey Puzyr ◽  
Irina Baron ◽  
...  
Keyword(s):  
1969 ◽  
Vol 62 (1_Suppl) ◽  
pp. S95-S112 ◽  
Author(s):  
A. H. W. M. Schuurs

ABSTRACT Various techniques for sensitising erythrocytes and latex particles with gonadotrophins, particularly with HCG, are described. The haemagglutination inhibition reactions are generally interpreted by means of »erythrocyte settling patterns«. By a new method of evaluating these patterns a relatively precise quantitative determination is possible. Latex agglutination inhibition reactions on slides are particularly suitable as rapid qualitative tests. In cases where the maximum attainable sensitivity of the agglutination inhibition tests is insufficient, e. g. for determining LH concentrations in urine, the hormone in the test fluid has to be concentrated or extracted. An alternative method is a modified haemagglutination inhibition test for large volumes which is applicable to unconcentrated urine. Due to non-specific inhibitions the above-mentioned tests cannot be applied to unprocessed serum. Agglutination inhibition tests with HCG are already well advanced, pregnancy diagnosis being their main application. Now that highly purified HCG is available, a satisfactory specificity for these tests can be attained. If the immune system for HCG is used for estimating LH, it has to meet additional specificity requirements. Furthermore, the measure of cross-reaction and the choice of standard merit special attention. Finally, a literature survey is given of test systems in which LH and FSH were used as antigens.


1990 ◽  
Vol 10 (1) ◽  
pp. 89-92 ◽  
Author(s):  
Liliane Larpent ◽  
Christian Verger

The fate of the peritoneal membrane on continuous ambulatory peritoneal dialysis (CAPD) is usually evaluated through the modification of its permeability to various solutes as glucose, creatinine, and urea. Therefore, the accuracy of the methods used for measurements of creatinine is of great importance. A particular problem does exist for creatinine determination as it may be influenced by the presence of glucose. We studied a new enzymatic colorimetric method for creatinine determination in peritoneal dialysis solutions which contain high dextrose concentrations. Creatinine was measured in plasma, urine, and dialysate from 18 patients on CAPD and in pure dextrose solutions, with an enzymatic test (Boehringer Mannheim) and with Jaffe's reaction on two different analyzers: Astra (Beckman) and Eris (Merck). Creatinine results were similar with both assays (Jaffe's reaction and enzymatic test) when measured in blood and urine. However the Jaffe's reaction gave higher creatinine results than the enzymatic test (p < 0.001), when assays were performed in peritoneal dialysis solutions and in pure glucose solutions. In addition, it appeared that other components of dialysis solutions, mainly calcium chloride, influenced unpredictably the results of creatinine with the Jaffe's reaction. We conclude that specific enzymatic test is a more accurate and reliable method to evaluate creatinine kinetics through the peritoneal membrane when determined in CAPD solutions.


2012 ◽  
Vol 30 (8) ◽  
pp. 714-723 ◽  
Author(s):  
Hakan Ozkan ◽  
Derya Yanmis ◽  
Mehmet Karadayi ◽  
Tugba Bal ◽  
Ozlem Baris ◽  
...  
Keyword(s):  
E Coli ◽  

Author(s):  
Sh. I. Razokov ◽  
◽  
D. M. Mirzoev ◽  
G. P. Kononenko ◽  
A. A. Burkin ◽  
...  

The article presents the results of an extensive mycotoxicological examination of 11 samples of peanut beans grown in two regions of the Republic of Tajikistan. The determination of 16 mycotoxins was carried out by indirect competitive enzyme-linked immunosorbent assay using commercial and certified research test systems. It has been established that for peanut beans in this area, a combined contamination by a group of sanitary-significant mycotoxins, including diacetoxyscirpenol, alternariol, ochratoxin A, PR-toxin and cyclopiazonic acid, is characteristic. The prospects of further research and the practical significance of the results are discussed.


1980 ◽  
Vol 106 (1) ◽  
pp. 213-222 ◽  
Author(s):  
Gunter M. Rothe ◽  
Werner Maurer ◽  
Elke Bohrisch ◽  
Peter Reichert

2021 ◽  
Vol 1 (19) ◽  
pp. 219-220
Author(s):  
L. Barshevskaya ◽  
D. Sotnikov ◽  
A. Zherdev ◽  
B. Dzantiev

Methods for increasing the sensitivity of immunochromatographic test systems for the determination of low molecular weight analytes are proposed. The developed analysis schemes were tested in the determination of sulfonylamide and chloramphenicol in honey.


2011 ◽  
Vol 3 (3) ◽  
pp. 175-179 ◽  
Author(s):  
Stefanie Schoepe ◽  
Heike Schäcke ◽  
Khusru Asadullah

2020 ◽  
Author(s):  
S. Kamliuk ◽  
O. Boris ◽  
T. Gomolko ◽  
T. Lisovskaya ◽  
T. Demenkova ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document