scholarly journals Absorption in a three-phase fluidized bed II: Mass transfer investigations

2003 ◽  
Vol 57 (7-8) ◽  
pp. 330-334
Author(s):  
Srdjan Pejanovic ◽  
Radmila Garic-Grulovic ◽  
Predrag Bozalo

The absorption of carbon dioxide in aqueous diethanolamine solutions was carried out in a three-phase fluidized bed with inert spherical packing. The rate of absorption was calculated on the basis of measuring the concentration change in the liquid phase on-line by a conductivity probe. It was shown that the Danckwerts plot method might be successfully used to simultaneously determine the effective interfacial area and both the gas and liquid-side mass transfer coefficients. While the gas-side mass transfer coefficient is independent of the liquid flow rate, the effective interfacial area and liquid-side mass transfer coefficient increase with increasing liquid flow rate.

1986 ◽  
Vol 51 (10) ◽  
pp. 2127-2134 ◽  
Author(s):  
František Potůček ◽  
Jiří Stejskal

Absorption of oxygen into water and aqueous solutions of poly(acrylamides) was studied in an absorber with a wetted sphere. The effects of changes in the liquid flow rate and the polymer concentration on the liquid side mass transfer coefficient were examined. The results are expressed by correlations between dimensionless criteria modified for non-Newtonian liquids whose flow curve can be described by the Ostwald-de Waele model.


Konversi ◽  
2019 ◽  
Vol 7 (1) ◽  
pp. 6
Author(s):  
Erlinda Ningsih ◽  
Abas Sato ◽  
Mochammad Alfan Nafiuddin ◽  
Wisnu Setyo Putranto

Abstract- One of the most widely used processes for CO2 gas removal is Absorption. Carbon dioxide is the result of the fuel combustion process which of the hazardous gases. The aim of this research is to determine the total mass transfer coefficient and analyze the effect of the absorbent flow rate of the absorbent solution with the promoter and the gas flow rate to the total mass transfer coefficient value. The variables consisted of liquid flow rate: 1, 2, 3, 4, 5 liter/min, gas flow rate: 15, 25, 30, 40, 50 liter/min and MSG concentration: 0%, 1%, 3% and 5% by weight. The solution of Pottasium Carbonate as absorbent with MSG promoter is flowed through top column and CO2 gas flowed from bottom packed column. Liquids were analyzed by titration and the gas output was analyzed by GC. From this research, it is found that the flow rate of gas and the liquid flow rate is directly proportional to the value of KGa. The liquid flow rate variable 5 liters / minute, gas flow rate 15 l / min obtained value of KGa 11,1102 at concentration of MSG 5%. Keywords:  Absorption, CO2,  K2CO3, MSG. 


Author(s):  
Arash Arabmarkadeh ◽  
Mohsen Nosrati ◽  
Mohammad Amin Hejazi ◽  
Seyed Mohammad Mousavi

AbstractBioreactors are used in many biochemical industries to produce commercial life products such as medicines, enzymes, perfumes, paints and antibiotics. In the presented study, a specially shaped bioreactor has been designed, built and operated to increase the mass transfer coefficient. The constructed bioreactor, according to type of microorganisms, can provide high amounts of oxygen or carbon dioxide. Moreover, the manuscript was aimed at investigating the hydrodynamic properties of the bioreactor. The bioreactor was constructed from three parts including shower in upper part, middle section for mass transfer and bottom section as a reservoir. Liquid flow rate, shower holes diameter, aeration velocity and the middle part height of the bioreactor have been studied as factors influencing the hydrodynamics. The results showed that the highest mass transfer coefficient was 30.1 1/h which was achieved when the liquid flow rate, the shower holes diameter, aeration velocity and middle part height of the bioreactor were 280 mL/min, 2 mm, 0.03 vvm and 60 cm, respectively.


1994 ◽  
Vol 29 (10-11) ◽  
pp. 231-241 ◽  
Author(s):  
H. T. Chang ◽  
B. E. Rittmann

This paper presents a unified model that inter-relates gas flow rate, liquid flow rate, and hold-ups of each of the liquid, gas, and solid phases in three-phase, fluidized-bed biofilm (TPFBB) process. It describes how carrier properties, biofilm properties, and gas and liquid flow velocities control the system dynamics, which ultimately will affect the density, thickness, and distribution of the biofilm. The paper describes the development of the mathematical model to correlate the effects of gas flow rate, liquid flow rate, solid concentration, and biofilm thickness and density. This knowledge is critically needed in light of the use of TPFBB processes in treating industrial wastewater, which often has high substrate concentration. For example, the proper design of the TPFBB process requires mathematical description of the cause-effect relationship between biofilm growth and fluidization.


2015 ◽  
Vol 31 (4) ◽  
Author(s):  
Reza Afshar Ghotli ◽  
Abdul Raman Abdul Aziz ◽  
Shaliza Ibrahim

AbstractA general review on correlations to evaluate mass transfer coefficients in liquid-liquid was conducted in this work. The mass transfer models can be classified into continuous and dispersed phase coefficients. The effects of drop size and interfacial area on mass transfer coefficient were investigated briefly. Published experimental results for both continuous and dispersed phase mass transfer coefficients through different hydrodynamic conditions were considered and the results were compared. The suitability and drawbacks of these correlations depend on the operating conditions and hydrodynamics. Although the results of these models are reasonably acceptable, they could not properly predict the experimental results over a wide range of designs and operating conditions. Therefore, proper understanding of various factors affecting mass transfer coefficient needs to be further extended.


Enhancement of mass transfer coefficient is highly desirable for economic design of process equipment. The present study is essentially carried out to know the effect of flow variables such as gas and liquid velocities and geometric parameters of the internal on mass transfer coefficients in a three phase fluidized bed. The mass transfer coefficient data were obtained using a string of cones internal in a three-phase fluidized bed electrochemical reactor. The flow system investigated was nitrogen, a fluid electrolyte and spherical glass beads as gas, liquid and solid phases respectively. Limiting current technique was employed to obtain mass transfer data. The internal comprises of a string of cones arranged concentrically on a central rod which is placed coaxially in a three phase fluidized bed. The presence of internal in three phase fluidized beds augmented the mass transfer coefficient significantly. In the present investigation it was found that the effect of gas velocity, liquid velocity, rod diameter and cone diameter was only marginal. However, the influence of pitch, half apex angle of cone and particle diameter was found to be significant. Correlations were developed based on least squares regression analysis for the prediction of mass transfer coefficient in terms of pertinent variables


1980 ◽  
Vol 45 (11) ◽  
pp. 3089-3100 ◽  
Author(s):  
Zdeněk Brož ◽  
Mirko Endršt

Prediction of the liquid side mass transfer coefficient k1 at vertical liquid flow on the expanded metal packing is based on the penetration model according to Higbie. The experimental value of mass transfer coefficient k1 at absorption of sparingly soluble gases with differing diffusivities in water (propane, carbon dioxide and helium) are in a good agreement with the predicted values in a wide range of linear wetting densities. Interfacial area is determined by the chemical method and is correlated by an empirical relation.


Author(s):  
K.V. Shetty ◽  
G. Srinikethan

Volumetric oxygen mass transfer coefficient is a decisive parameter for the selection of any contactor as an aerobic bioreactor. A pulsed plate column with fixed bed of solids in interplate spaces is a recent innovation in the field of immobilized cell bioreactors. Volumetric oxygen mass transfer coefficients are determined in a three-phase pulsed plate column involving air and water phases and with a fixed bed of glass particles, which can serve as a surface for cell immobilization packed in the interplate spaces. The volumetric mass transfer coefficients obtained in this column range from 0.067 to 0.1495 s-1 in the range of air superficial velocities from 0.011 to 0.047m/s and vibrational velocities from 0.825 to 6cm/s. Volumetric oxygen mass transfer coefficient has increased with the increase in superficial air velocity and vibrational velocity. Empirical correlation relating kLa with these variables was developed. The volumetric oxygen mass transfer coefficient values in the three-phase pulsed plate column are found to be similar or higher than the literature reported values for conventional two-phase pulsed plate columns. The values of volumetric oxygen mass transfer coefficients in the three-phase pulsed plate column are of higher order of magnitude than the literature reported values of volumetric oxygen mass transfer coefficient for many other three-phase gas-liquid-solid reactors. The pulsed plate column with fixed bed of solids is proven to have all the potential to be used as an aerobic bioreactor with immobilized cells due to its better gas-liquid mass transfer characteristics.


Sign in / Sign up

Export Citation Format

Share Document