scholarly journals Impact of CO2 concentration on indoor air quality and correlation with relative humidity and indoor air temperature in school buildings in Serbia

2016 ◽  
Vol 20 (suppl. 1) ◽  
pp. 297-307 ◽  
Author(s):  
Ivan Lazovic ◽  
Zarko Stevanovic ◽  
Milena Jovasevic-Stojanovic ◽  
Marija Zivkovic ◽  
Milos Banjac

Previous studies have shown that poorly ventilated classrooms can have negative impact on the health of children and school staff. In most cases, schools in Serbia are ventilated naturally. Considering their high occupancy, classroom air quality test determines the level of air pollution, after which it is possible to implement corrective measures. The research presented in this study was conducted in four schools which are located in different areas and have different architecture designs. Measurements in these schools have been performed during the winter (heating season) and spring (non-heating season) and the following results were presented: indoor air temperature, relative humidity and carbon dioxide concentration. These results show that the classroom average concentration of carbon dioxide often exceeds the value of 1500 ppm, during its full occupancy, which indicates inadequate ventilation. Measurement campaigns show that carbon dioxide concentration increased significantly from non-heating to heating season in three of the four schools. Analysis of measurements also determined high correlation between relative humidity and carbon dioxide concentration in all schools in winter season. This fact may constitute a solid basis for the fresh air supply strategy.

Author(s):  
Vesna Lovec ◽  
Miroslav Premrov ◽  
Vesna Žegarac Leskovar

The experimental monitoring of carbon dioxide concentration was carried out in kindergartens in Slovenia, together with indoor air temperature and relative humidity, before and during the COVID-19 pandemic. The aim of the research was to estimate the practical impact of the pandemic on indoor air quality and thermal comfort. The case study sample included buildings with different architectural typology, which are predominantly present in the building stock of Slovenia. The monitoring process lasted for 125 days before and during the COVID-19 pandemic. The results have shown a better indoor air quality in kindergartens during the pandemic, mostly due to ventilation protocols and almost imperceptibly changed indoor air temperature. The COVID-19 pandemic affected air quality in kindergarten classrooms in Slovenia by reducing the average carbon dioxide concentration when children were present in classrooms by 30%.


2017 ◽  
Vol 40 (1) ◽  
pp. 83-90
Author(s):  
Mario Ostović ◽  
Sven Menčik ◽  
Ivica Ravić ◽  
Slavko Žužul ◽  
Željko Pavičić ◽  
...  

Abstract Good air quality in poultry houses is crucial for animal health and productivity. In these houses, air is generally contaminated with noxious gases and microorganisms, the concentrations of which depend on numerous factors including microclimate. In this case study, the relation between microclimate and air concentrations of noxious gases and microorganisms was investigated in extensively reared turkey house. The study was carried out at a family household in Dalmatia hinterland, Croatia, with 50.3±3.1 turkeys kept in the house during the study period. Air temperature, relative humidity, airflow rate, concentrations of ammonia, carbon dioxide, bacteria and fungi in indoor air were measured three times per month from September to December, in the morning, prior to releasing turkeys out for grazing. Air temperature ranged from 9.73 to 26.98 °C, relative humidity from 63.29% to 75.08%, and airflow rate from 0.11 to 0.17 m/s. Lowest ammonia and carbon dioxide concentrations were measured in September (2.17 ppm and 550 ppm, respectively) and highest in December (4.50 ppm and 900 ppm, respectively). Bacterial and fungal counts were lowest in December (2.51×105 CFU/m3 and 3.27×103 CFU/m3 air, respectively) and highest in September (6.85×105 CFU/m3 and 1.06x105 CFU/m3 air, respectively). Air temperature and relative humidity showed negative correlation with concentrations of noxious gases and positive correlation with air microorganisms (P<0.05 all).


Proceedings ◽  
2020 ◽  
Vol 51 (1) ◽  
pp. 2
Author(s):  
Katarzyna Gładyszewska-Fiedoruk

The work presents an attempt to understand how three basic air pollutants in a room have an influence on indoor air quality. The aim of the study is to analyze the air quality in a conference room, determining whether (and if so, which) correlations occur among air pollutants in a room where the only sources of pollution is people. The air temperature, relative humidity and carbon dioxide concentration in the air in the room were analyzed. When analyzing the correlation among the measurement results, it should be clearly stated that the impurities that come only from people are correlated with each other.


2016 ◽  
Vol 836 ◽  
pp. 121-126
Author(s):  
Pradip Aryal ◽  
Thananchai Leephakpreeda

This paper presents a CFD analysis on thermal comfort and indoor air quality affected by partitions in an air-conditioned building. CFD experiments are carried out to simulate variables of indoor air before/after installation or removal of partitions. Accordingly, the Predicted Mean Vote (PMV) is determined as an indicator of thermal comfort while the carbon dioxide concentration within an air-conditioned space is used for the assessment of indoor air quality. Some simulated results are validated by measurements with good agreement where a case study is conducted in an air-conditioned space of a library. With the proposed methodology, it can be recommended in a case study that the significant effects of partition on thermal comfort are observed where the area with neutral sensation and slightly-cool sensation reduces significantly. The occupants feel uncomfortably cold after installing partition. The carbon dioxide concentrations slightly increase in some areas but the average concentration remains acceptable according to ASHRAE standard. Without the reinforcement of the air-conditioning units, the installation of partition at the desired location is not encouraged regarding to occupant’s thermal comfort and indoor air quality.


2019 ◽  
Vol 7 ◽  
pp. 954-959 ◽  
Author(s):  
Detelin Ganchev Markov ◽  
Sergey Mijorski ◽  
Peter Stankov ◽  
Iskra Simova ◽  
Radositna A. Angelova ◽  
...  

: People are one of the sources for deterioration of the indoor air quality. They worsen indoor air quality by their presence (respiration, bio-effluents), activities and habits. Through respiration, people decrease the oxygen concentration in the air of the occupied space and increase carbon dioxide and water vapor concentration in the indoor air as well as its temperature. The goal of the AIRMEN project is to find out if the rate of consumption of oxygen and emission of carbon dioxide (and water vapor) by people depends on the indoor air temperature as well as carbon dioxide concentration in the inhaled air. In order to achieve this goal a small climate chamber must be designed and constructed which allows for controlling and measuring both inflow and exposure parameters as well as for measuring outflow parameters. The principal goal of this paper is to present some important details, obtained by CFD simulations, from the design process of the climate chamber which precondition the air distribution in the chamber and hence the exposure parameters.


Buildings ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. 124 ◽  
Author(s):  
Claire Tam ◽  
Yuqing Zhao ◽  
Zaiyi Liao ◽  
Lian Zhao

Indoor air quality and thermal conditions are important considerations when designing indoor spaces to ensure occupant health, satisfaction, and productivity. Carbon dioxide (CO2) concentration and indoor air temperature are two measurable parameters to assess air quality and thermal conditions within a space. Occupants are progressively affected by the indoor environment as the time spent indoors prolongs. Specifically, there is an interest in carrying out investigations on the indoor environment through surveying existing Heating, Ventilation, Air Conditioning (HVAC) system operations in classrooms. Indoor air temperature and CO2 concentration in multiple lecture halls in Toronto, Canada were monitored; observations consistently show high indoor air temperature (overheating) and high CO2 concentration. One classroom is chosen as a representative case study for this paper. The results verify a strong correlation between the number of occupants and the increase in air temperature and CO2 concentration. Building Energy Simulation (BES) is used to investigate the causes of discomfort in the classroom, and to identify methods for regulating the temperature and CO2 concentration. This paper proposes retro-commissioning strategies that could be implemented in institutional buildings; specifically, the increase of outdoor airflow rate and the addition of occupancy-based pre-active HVAC system control. The proposed retrofit cases reduce the measured overheating in the classrooms by 2-3 °C (indoor temperature should be below 23 °C) and maintain CO2 concentration under 900 ppm (the CO2 threshold is 1000 ppm), showing promising improvements to a classroom’s thermal condition and indoor air quality.


2020 ◽  
Vol 10 (13) ◽  
pp. 4631
Author(s):  
Motokazu Moritani ◽  
Norifumi Watanabe ◽  
Kensuke Miyamoto ◽  
Kota Itoda ◽  
Junya Imani ◽  
...  

Recent indoor air quality studies show that even 1000 parts per million (ppm) concentration of Carbon Dioxide (CO2) has an adverse effect on human intellectual activities. Therefore, it is required to keep the CO 2 concentration below a certain value in a room. In this study, in order to analyze the diffusion tendency of carbon dioxide by breathing, we constructed a simultaneous multi-point sensing system equipped with a carbon dioxide concentration sensor to measure indoor environment. Furthermore, it was evaluated whether the prediction model can be effectively used by comparing the prediction value by the model and the actually measured value from the sensor. The experimental results showed that CO 2 by exhaled breathing diffuses evenly throughout the room regardless of the sensor’s relative positions to the human test subjects. The existing model is sufficiently accurate in a room which has above at least a 0.67 cycle/h ventilation cycle. However, there is a large gap between the measured and the model’s predicted values in a room with a low ventilation cycle, and that suggests a measurement with a sensor still is necessary to precisely monitor the indoor air quality.


Proceedings ◽  
2018 ◽  
Vol 2 (20) ◽  
pp. 1309 ◽  
Author(s):  
Antonio Rodero ◽  
Dorota Anna Krawczyk

Carbon dioxide concentration is an important parameter to know Indoor Air Quality of a building. One of the most important sources of CO2 in poor ventilated building is human activity. This work presents a method for experimental determination of human CO2 generation rate based on measuring of time evolution of indoor CO2 concentration. The method is applied to 5 rooms of an educational building from Bialystok (Poland). Similar carbon dioxide gains were obtained in all rooms, around 0.0046 L/s, which correspond to theoretical CO2 generation rates of a sedentary activity for persons, males and females, between 21–30 years old, characteristics of occupants of analyzed rooms.


2018 ◽  
Vol 28 (4) ◽  
pp. 506-519 ◽  
Author(s):  
Josefin Persson ◽  
Thanh Wang ◽  
Jessika Hagberg

The use of an airtight frame in low-energy buildings could increase the risk of health-related problems, such as allergies and sick building syndromes (SBS), associated with chemical emissions from building materials, especially if the ventilation system is not functioning properly. In this study, the indoor air quality (IAQ) was investigated in newly built low-energy and conventional preschools by monitoring the indoor air temperature, relative humidity, particle-size distribution and levels of carbon dioxide (CO2), nitrogen dioxide (NO2), formaldehyde and total volatile organic compounds (TVOC). The thermal comfort was satisfactory in all preschools, with average indoor air temperature and a relative humidity at 21.4°C and 36%, respectively. The highest levels of TVOC (range: 130–1650 µg/m3 toluene equivalents) and formaldehyde (range: 1.9–28.8 µg/m3) occurred during the first sampling period associated with strong emissions from building materials. However, those preschools constructed with environmental friendly building materials (such as Swan Eco-label) had lower initial TVOC levels compared to those preschools constructed with conventional building materials. The IAQ and indoor chemical emissions were also strongly dependent on the functioning of the ventilation system. Preliminary risk assessment indicated that exposure to acrolein and crotonaldehyde might lead to respiratory-tract irritation among occupants.


Sign in / Sign up

Export Citation Format

Share Document