scholarly journals Analysis of Carbon Dioxide Concentration Prediction Model and Diffusion Tendency of Expiratory by Simultaneous Multipoint Sensing

2020 ◽  
Vol 10 (13) ◽  
pp. 4631
Author(s):  
Motokazu Moritani ◽  
Norifumi Watanabe ◽  
Kensuke Miyamoto ◽  
Kota Itoda ◽  
Junya Imani ◽  
...  

Recent indoor air quality studies show that even 1000 parts per million (ppm) concentration of Carbon Dioxide (CO2) has an adverse effect on human intellectual activities. Therefore, it is required to keep the CO 2 concentration below a certain value in a room. In this study, in order to analyze the diffusion tendency of carbon dioxide by breathing, we constructed a simultaneous multi-point sensing system equipped with a carbon dioxide concentration sensor to measure indoor environment. Furthermore, it was evaluated whether the prediction model can be effectively used by comparing the prediction value by the model and the actually measured value from the sensor. The experimental results showed that CO 2 by exhaled breathing diffuses evenly throughout the room regardless of the sensor’s relative positions to the human test subjects. The existing model is sufficiently accurate in a room which has above at least a 0.67 cycle/h ventilation cycle. However, there is a large gap between the measured and the model’s predicted values in a room with a low ventilation cycle, and that suggests a measurement with a sensor still is necessary to precisely monitor the indoor air quality.

2019 ◽  
Vol 7 ◽  
pp. 954-959 ◽  
Author(s):  
Detelin Ganchev Markov ◽  
Sergey Mijorski ◽  
Peter Stankov ◽  
Iskra Simova ◽  
Radositna A. Angelova ◽  
...  

: People are one of the sources for deterioration of the indoor air quality. They worsen indoor air quality by their presence (respiration, bio-effluents), activities and habits. Through respiration, people decrease the oxygen concentration in the air of the occupied space and increase carbon dioxide and water vapor concentration in the indoor air as well as its temperature. The goal of the AIRMEN project is to find out if the rate of consumption of oxygen and emission of carbon dioxide (and water vapor) by people depends on the indoor air temperature as well as carbon dioxide concentration in the inhaled air. In order to achieve this goal a small climate chamber must be designed and constructed which allows for controlling and measuring both inflow and exposure parameters as well as for measuring outflow parameters. The principal goal of this paper is to present some important details, obtained by CFD simulations, from the design process of the climate chamber which precondition the air distribution in the chamber and hence the exposure parameters.


Proceedings ◽  
2018 ◽  
Vol 2 (20) ◽  
pp. 1309 ◽  
Author(s):  
Antonio Rodero ◽  
Dorota Anna Krawczyk

Carbon dioxide concentration is an important parameter to know Indoor Air Quality of a building. One of the most important sources of CO2 in poor ventilated building is human activity. This work presents a method for experimental determination of human CO2 generation rate based on measuring of time evolution of indoor CO2 concentration. The method is applied to 5 rooms of an educational building from Bialystok (Poland). Similar carbon dioxide gains were obtained in all rooms, around 0.0046 L/s, which correspond to theoretical CO2 generation rates of a sedentary activity for persons, males and females, between 21–30 years old, characteristics of occupants of analyzed rooms.


2017 ◽  
Vol 9 (2) ◽  
pp. 179-192 ◽  
Author(s):  
N. L. Sireesha

The calculation of carbon dioxide (CO2)  intensities can be employed to see the quality of indoor air and ventilation. The studies undertaken till date have been distorted. The current study summaries the association amongst carbon dioxide and building air quality and ventilation, with carbon dioxide being the marker to evaluate air quality and ventilation performance. High carbon dioxide intensities may show insufficient ventilation per occupant and high indoor contaminants intensities, resulting in the Sick Building Syndrome (SBI) Symptoms. The researcher assessed the literature related to indoor air quality (IAQ), ventilation, and building-linked health issues in schools linked to CO2 discharges and recognised general indicated building-linked well-being signs found in schools. A high rise in the ventilation rate or enhancement in ventilation efficacy and/or indoor contaminant source regulation would be anticipated to reduce the occurrence of chosen signs to its optimum.


Author(s):  
Vesna Lovec ◽  
Miroslav Premrov ◽  
Vesna Žegarac Leskovar

The experimental monitoring of carbon dioxide concentration was carried out in kindergartens in Slovenia, together with indoor air temperature and relative humidity, before and during the COVID-19 pandemic. The aim of the research was to estimate the practical impact of the pandemic on indoor air quality and thermal comfort. The case study sample included buildings with different architectural typology, which are predominantly present in the building stock of Slovenia. The monitoring process lasted for 125 days before and during the COVID-19 pandemic. The results have shown a better indoor air quality in kindergartens during the pandemic, mostly due to ventilation protocols and almost imperceptibly changed indoor air temperature. The COVID-19 pandemic affected air quality in kindergarten classrooms in Slovenia by reducing the average carbon dioxide concentration when children were present in classrooms by 30%.


Atmosphere ◽  
2020 ◽  
Vol 11 (10) ◽  
pp. 1024
Author(s):  
Trieu-Vuong Dinh ◽  
Joo-Yeon Lee ◽  
Ji-Won Ahn ◽  
Jo-Chun Kim

Carbon dioxide (CO2) is an indicator of indoor air quality. Ventilation based on the use of a CO2 indicator helps to prevent people from acquiring many diseases, especially respiratory viral infections. Therefore, the monitoring of CO2 is a pivotal issue in the control of indoor air quality. A nondispersive infrared (NDIR) analyzer with a wide range of measurements (i.e., ppmv to percentage levels) was developed for measuring carbon dioxide (CO2) in an indoor environment. The effects of optical pathlength and interfering gases were investigated. The pathlengths of the analyzer were varied at 4.8, 8, 10.4 and 16 m, and the interference gases were CO; NO2; SO2; H2O; BTEX (i.e., benzene, toluene, ethylbenzene and m-/p-xylene) and formaldehyde. The lower detection limit, selectivity and sensitivity were determined to evaluate the performance of the analyzer. It was found that different pathlengths should be used to produce linear calibration curves for CO2 from ppmv to percentage levels. As a result, a wide-range NDIR analyzer, coupled with flexible pathlengths from 4.8 to 10.4 m, was developed. In terms of interference, only H2O should be taken into account due to its high concentration in indoor air. CO should be considered in some special locations at the ppmv level. The measurement errors for ppmv and the percentage levels were 0.4 and 0.9%, respectively.


2019 ◽  
Author(s):  
Widya Nilandita ◽  
Ida Munfarida ◽  
M Ratodi ◽  
Dyah Ratri Nurmaningsih ◽  
Dedy Suprayogi

Indoor Air Quality (IAQ) is one of the critical issues in sustainable development related to human health as the primary goal. Sustainable development should address potential human exposure to pollutants and health impacts. The laboratory, as educational support in the university, has specific contaminants, but studies on IAQ and thermal comfort in the laboratory have not been studied. IAQ and thermal comfort in a laboratory are essential as they can affect the work and health of the researchers and staffs. The purpose of this study is to analyze indoor air quality in an integrated laboratory of UIN Sunan Ampel Surabaya. This research is a cross-sectional study. Data analysis was done by a quantitative descriptive method. The air quality parameters in the laboratory were temperature, relative humidity, and carbon dioxide (CO2) concentration. All settings compared to the air quality standard. The analysis on carbon dioxide (CO2) concentration, relative humidity (%RH), temperature (∘C) has shown that the indoor air does not exceed the standard according to ASHRAE standard and Health Ministry Regulation with the maximum concentration was 444,3 ppm. The fan installation and increased air filter to controlled humidity are the option to improve the indoor air quality.


Proceedings ◽  
2020 ◽  
Vol 51 (1) ◽  
pp. 2
Author(s):  
Katarzyna Gładyszewska-Fiedoruk

The work presents an attempt to understand how three basic air pollutants in a room have an influence on indoor air quality. The aim of the study is to analyze the air quality in a conference room, determining whether (and if so, which) correlations occur among air pollutants in a room where the only sources of pollution is people. The air temperature, relative humidity and carbon dioxide concentration in the air in the room were analyzed. When analyzing the correlation among the measurement results, it should be clearly stated that the impurities that come only from people are correlated with each other.


2016 ◽  
Vol 836 ◽  
pp. 121-126
Author(s):  
Pradip Aryal ◽  
Thananchai Leephakpreeda

This paper presents a CFD analysis on thermal comfort and indoor air quality affected by partitions in an air-conditioned building. CFD experiments are carried out to simulate variables of indoor air before/after installation or removal of partitions. Accordingly, the Predicted Mean Vote (PMV) is determined as an indicator of thermal comfort while the carbon dioxide concentration within an air-conditioned space is used for the assessment of indoor air quality. Some simulated results are validated by measurements with good agreement where a case study is conducted in an air-conditioned space of a library. With the proposed methodology, it can be recommended in a case study that the significant effects of partition on thermal comfort are observed where the area with neutral sensation and slightly-cool sensation reduces significantly. The occupants feel uncomfortably cold after installing partition. The carbon dioxide concentrations slightly increase in some areas but the average concentration remains acceptable according to ASHRAE standard. Without the reinforcement of the air-conditioning units, the installation of partition at the desired location is not encouraged regarding to occupant’s thermal comfort and indoor air quality.