scholarly journals Solar thermal and wind energy applications: Case study of a small Spanish village

2018 ◽  
Vol 22 (5) ◽  
pp. 2163-2176 ◽  
Author(s):  
Christos Ioakimidis ◽  
Sesil Koutra ◽  
Ali Bagheri ◽  
Konstantinos Genikomsakis

The present work examines the supply of heating and electricity to the Spanish village of Uruena, using biomass and other local renewable sources as a result of the growing interest worldwide towards the development of sustainable and energy independent small communities. Specifically, this case study considers the design of a district heating system consisting of a solar heating plant, a biomass plant using straw as a sustainable fuel for the base load and an oil boiler for the peak load, coupled with a hot water tank as a thermal energy storage option. Two alternative scenarios are analyzed for electricity generation purposes, namely a system consisting of three small wind turbines and a system with a single large wind turbine. The results show that the cost of large-scale electricity storage depends on the application and often involves significant capital investments.

Author(s):  
Anna Volkova ◽  
Vladislav Mashatin ◽  
Aleksander Hlebnikov ◽  
Andres Siirde

Abstract The purpose of this paper is to offer a methodology for the evaluation of large district heating networks. The methodology includes an analysis of heat generation and distribution based on the models created in the TERMIS and EnergyPro software Data from the large-scale Tallinn district heating system was used for the approbation of the proposed methodology as a basis of the case study. The effective operation of the district heating system, both at the stage of heat generation and heat distribution, can reduce the cost of heat supplied to the consumers. It can become an important factor for increasing the number of district heating consumers and demand for the heat load, which in turn will allow installing new cogeneration plants, using renewable energy sources and heat pump technologies


2021 ◽  
Vol 246 ◽  
pp. 09003
Author(s):  
Haoran Li ◽  
Juan Hou ◽  
Yuemin Ding ◽  
Natasa Nord

Peak load has significant impacts on the economic and environmental performance of district heating systems. Future sustainable district heating systems will integrate thermal storages and renewables to shave their peak heat demand from traditional heat sources. This article analysed the techno-economic potential of implementing thermal storage for peak load shaving, especially for the district heating systems with waste heat recovery. A campus district heating system in Norway was chosen as the case study. The system takes advantage of the waste heat from the campus data centre. Currently, about 20% of the heating bill is paid for the peak load, and a mismatch between the available waste heat and heat demand was detected. The results showed that introducing water tank thermal storage brought significant effects on peak load shaving and waste heat recovery. Those effects saved up to 112 000 EUR heating bills annually, and the heating bill paid for the peak load could be reduced by 15%. Meanwhile, with the optimal sizing and operation, the payback period of the water tank could be decreased to 13 years. Findings from this study might help the heat users to evaluate the economic feasibility of introducing thermal storage.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3350
Author(s):  
Theofanis Benakopoulos ◽  
William Vergo ◽  
Michele Tunzi ◽  
Robbe Salenbien ◽  
Svend Svendsen

The operation of typical domestic hot water (DHW) systems with a storage tank and circulation loop, according to the regulations for hygiene and comfort, results in a significant heat demand at high operating temperatures that leads to high return temperatures to the district heating system. This article presents the potential for the low-temperature operation of new DHW solutions based on energy balance calculations and some tests in real buildings. The main results are three recommended solutions depending on combinations of the following three criteria: district heating supply temperature, relative circulation heat loss due to the use of hot water, and the existence of a low-temperature space heating system. The first solution, based on a heating power limitation in DHW tanks, with a safety functionality, may secure the required DHW temperature at all times, resulting in the limited heating power of the tank, extended reheating periods, and a DH return temperature of below 30 °C. The second solution, based on the redirection of the return flow from the DHW system to the low-temperature space heating system, can cool the return temperature to the level of the space heating system return temperature below 35 °C. The third solution, based on the use of a micro-booster heat pump system, can deliver circulation heat loss and result in a low return temperature below 35 °C. These solutions can help in the transition to low-temperature district heating.


Energies ◽  
2020 ◽  
Vol 13 (15) ◽  
pp. 3782 ◽  
Author(s):  
Antti Teräsvirta ◽  
Sanna Syri ◽  
Pauli Hiltunen

Small Modular Reactors (SMRs) have been recognized to have potential in decarbonizing district heating, which is currently an urgent sustainability challenge in many European countries. In this paper, the financial impacts of replacing peat and biomass-powered Combined Heat and Power (CHP) plants with heat-only reactors of 24–200 MW power range and maximum output temperatures of 120 °C are studied. A district heating system of a medium-sized Nordic city in Eastern Finland is modeled with EnergyPRO computer software (EMD International A/S, Aalborg, Denmark), which is used to optimize plant units’ production for cost effectiveness. A future scenario is used to predict electricity prices, expenditures from CO2 emission allowances, and fuel prices for the studied case. Results show that the low operating expenditures of CO2 free heat-only reactors would compensate for the revenue losses from electricity sales and that a small number of micro reactors, with power output in the tens of megawatts range each, would be optimal for the studied case. Since investment cost estimates for SMRs still bear significant uncertainties, the subject should be followed in further studies, as heat-only SMRs could provide a profitable alternative for current CHP production in the future.


2020 ◽  
Vol 160 ◽  
pp. 01004 ◽  
Author(s):  
Stanislav Chicherin ◽  
Lyazzat Junussova ◽  
Timur Junussov

Proper adjustment of domestic hot water (DHW) load structure can balance energy demand with the supply. Inefficiency in primary energy use prompted Omsk DH company to be a strong proponent of a flow controller at each substation. Here the return temperature is fixed to the lowest possible value and the supply temperature is solved. Thirty-five design scenarios are defined for each load deviation index with equally distributed outdoor temperature ranging from +8 for the start of a heating season towards extreme load at temperature of -26°C. All the calculation results are listed. If a flow controller is installed, the customers might find it suitable to switch to this type of DHW supply. Considering an option with direct hot water extraction as usual and a flow controller installed, the result indicates that the annual heat consumption will be lower once network temperatures during the fall or spring months are higher. The heat load profiles obtained here may be used as input for a simulation of a DH substation, including a heat pump and a tank for thermal energy storage. This design approach offers a quantitative way of sizing temperature levels in each DH system according to the listed methodology and the designer's preference.


2020 ◽  
Vol 24 (6 Part A) ◽  
pp. 3673-3684
Author(s):  
Borna Doracic ◽  
Marino Grozdek ◽  
Tomislav Puksec ◽  
Neven Duic

District heating systems already play an important role in increasing the sustainability of the heating sector and decreasing its environmental impact. However, a high share of these systems is old and inefficient and therefore needs to change towards the 4th generation district heating, which will incorporate various energy sources, including renewables and excess heat of different origins. Especially excess heat from industrial and service sector facilities is an interesting source since its potential has already been proven to be highly significant, with some researches showing that it could cover the heat demand of the entire residential and service sector in Europe. However, most analyses of its utilisation in district heating are not done on the hourly level, therefore not taking into account the variability of its availability. For that reason, the main goal of this work was to analyse the integration of industrial excess heat into the district heating system consisting of different configurations, including the zero fuel cost technologies like solar thermal. Furthermore, cogeneration units were a part of every simulated configuration, providing the link to the power sector. Excess heat was shown to decrease the operation of peak load boiler and cogeneration, that way decreasing the costs and environmental effect of the system. However, since its hourly availability differs from the heat demand, thermal storage needs to be implemented in order to increase the utilisation of this source. The analysis was performed on the hourly level in the energyPRO software


Vestnik MGSU ◽  
2019 ◽  
pp. 748-755 ◽  
Author(s):  
Saule K. Abildinova ◽  
Stanislav V. Chicherin

Introduction. The purpose of this investigation is to show what changes introduced in the mathematical model of a district heating system are capable of considerable improving the convergence of simulation results and actual data. The study evaluates the work of heating supply establishments with their customers as well as analysis of the ways of enhancing pump equipment efficiency that allows saving electric energy or increasing output at the same energy consumption. Materials and methods. Engineering acceptance of newly introduced and reconstructed facilities is conducted, heat loads are corrected, disconnections and recurrent connections of indebted consumers are carried out. Studying data submitted by a local heat supply establishment shows that pump seals made from iron and steel are subject accelerated wear in the course of operation. Results. Three variants of the problem solution are suggested: making seals from bronze or stainless steel, prevention of unjustified increase of seal clearances as well as using labyrinth pump seals. This will allow increasing pump equipment efficiency by 5 to 7 % and save about 2 × 105 kW∙h of electrical energy for every pump or increase of output at the same energy consumption. Taking into account that a pump station is a part of the district heating system and unmachined inner surfaces of the pumps have a significant roughness, grinding of these surfaces can improve their hydraulic characteristics of the pumps. In the scope of the suggested method, the entire district heating system is considered not in the situation when actual load is equal to the sum of all the design loads and the pump equipment has manufacturer’s parameters, but accounting actual loads and characteristics. Conclusions. Mathematical model of district heating system heating and hydraulic mode that takes issues mentioned above into consideration would allow simulating joint operation of the heating and hot water supply systems at transient operation modes with higher accuracy.


2019 ◽  
Vol 112 ◽  
pp. 02006
Author(s):  
Viacheslav Antonenko ◽  
Sofiia Levinska

Residential sector plays a decisive role in the bioenergy sector growth in Ukraine. Larger half of biomass used by households comes from so-called self-production, which is problematic for the statistical monitoring. State Statistics do not publish detailed fuel mix reports on regional level. In this article we are providing a detailed data on fuel mix used by the households at regional level during 2007– 2016 and determine the biofuel self-production amount. The facilities that are direct emission sources and are the final fuel consumers, including individual heating/hot water boilers/stoves out of district heating system and individual cookers are considered in detail.