scholarly journals Thrust Characteristics of Water/Liquid Nitrogen Rocket Engine

Author(s):  
Rikio WATANABE ◽  
Kohei HAYASHI ◽  
Masaki IWAO ◽  
Keita IKAWA ◽  
Nobuyuki TOMITA
Author(s):  
Hang Gi Lee ◽  
Ju Hyun Shin ◽  
Suk Hwan Yoon ◽  
Dae Jin Kim ◽  
Jun Hwan Bae ◽  
...  

This study investigates the behavior of a turbopump assembly during critical cavitation of the propellant pumps in the upper rocket engine of the Korea Space Launch Vehicle-II. Turbopumps operate under conditions involving low pressure at the pump inlet and high rotational speeds to allow for a lightweight design. This severe environment can easily cause cavitation to occur in the pump. This cavitation can then cause the pump operation to fail. As the cavitation number in the pump decreases below the critical point, the pump fails to operate. There is concern regarding the behavior of the turbopump assembly arising from pump failure due to cavitation. It is necessary to verify the problems that may occur if the turbopump assembly operates under extreme conditions, such like the critical cavitation. This study performed tests to investigate the breakdown of pumps in the turbopump assembly. Tests were conducted with liquid nitrogen, water, and high-pressure air instead of the mediums used during actual operation of liquid oxygen, kerosene, and hot gas. The turbopump was tested at the design point of 27,000 rpm, while the inlet pressure of each pump was controlled to approach the critical cavitation number. The turbine power output was maintained during the tests. The results show that the breakdown point of the oxidizer pump using liquid nitrogen, which is a cryogenic medium, occurred at a lower cavitation number than during an individual component suction performance test using water. The fuel pump using water, meanwhile, experiences breakdown at similar cavitation numbers in both tests. As the breakdown of the pump occurs, the power required by that pump decreases, and the rotational speed of the turbopump increases. Compared with individual pump suction performance tests, this breakdown test can be used to determine the limit of the propellant inlet pressure of the turbopump and to characterize the behavior of the turbopump assembly when a breakdown occurs. Vibrations were also analyzed for tests at a high cavitation number and at the critical cavitation number. The vibration increased with breakdown and notable frequencies were analyzed.


Author(s):  
Claude Lechene

Electron probe microanalysis of frozen hydrated kidneysThe goal of the method is to measure on the same preparation the chemical elemental content of the renal luminal tubular fluid and of the surrounding renal tubular cells. The following method has been developed. Rat kidneys are quenched in solid nitrogen. They are trimmed under liquid nitrogen and mounted in a copper holder using a conductive medium. Under liquid nitrogen, a flat surface is exposed by sawing with a diamond saw blade at constant speed and constant pressure using a custom-built cryosaw. Transfer into the electron probe column (Cameca, MBX) is made using a simple transfer device maintaining the sample under liquid nitrogen in an interlock chamber mounted on the electron probe column. After the liquid nitrogen is evaporated by creating a vacuum, the sample is pushed into the special stage of the instrument. The sample is maintained at close to liquid nitrogen temperature by circulation of liquid nitrogen in the special stage.


Author(s):  
Louis T. Germinario

A liquid nitrogen stage has been developed for the JEOL JEM-100B electron microscope equipped with a scanning attachment. The design is a modification of the standard JEM-100B SEM specimen holder with specimen cooling to any temperatures In the range ~ 55°K to room temperature. Since the specimen plane is maintained at the ‘high resolution’ focal position of the objective lens and ‘bumping’ and thermal drift la minimized by supercooling the liquid nitrogen, the high resolution capability of the microscope is maintained (Fig.4).


Author(s):  
O. T. Inal ◽  
L. E. Murr

When sharp metal filaments of W, Fe, Nb or Ta are observed in the field-ion microscope (FIM), their appearance is differentiated primarily by variations in regional brightness. This regional brightness, particularly prominent at liquid nitrogen temperature has been attributed in the main to chemical specificity which manifests itself in a paricular array of surface-atom electron-orbital configurations.Recently, anomalous image brightness and streaks in both fcc and bee materials observed in the FIM have been shown to be the result of surface asperities and related topographic features which arise by the unsystematic etching of the emission-tip end forms.


Author(s):  
T. G. Naymik

Three techniques were incorporated for drying clay-rich specimens: air-drying, freeze-drying and critical point drying. In air-drying, the specimens were set out for several days to dry or were placed in an oven (80°F) for several hours. The freeze-dried specimens were frozen by immersion in liquid nitrogen or in isopentane at near liquid nitrogen temperature and then were immediately placed in the freeze-dry vacuum chamber. The critical point specimens were molded in agar immediately after sampling. When the agar had set up the dehydration series, water-alcohol-amyl acetate-CO2 was carried out. The objectives were to compare the fabric plasmas (clays and precipitates), fabricskeletons (quartz grains) and the relationship between them for each drying technique. The three drying methods are not only applicable to the study of treated soils, but can be incorporated into all SEM clay soil studies.


Author(s):  
Shaul Barkan

Cooling down solid state detecors, with other different way then liquid Nitrogen, is a goal of many vendors and customers since the invention of these detectors. THe disadvantage of the common way of liquid Nitrogen is first the inavailibility of the LN in many uses (like space military and any other applications that are not done inside a well organize Laboratory). The use of LN also considers as a Labor consumer in addition to the big dewar that has to be added to any detector for storing the LN, the boiling of the LN, may cause microphonics problesm and the refiling of the dewar in many Labs is a complicated process due to inconvenience location of the microscope.In this paper I will show a spectra result of 10mm2 SiLi detector for microanalysis use, cooled by peltier cooler. The peltier cooler has the advantage of non-microphonics and non-labor needed (like adding LN to the dewar).


Sign in / Sign up

Export Citation Format

Share Document