scholarly journals Detecting spatio-temporal urban surface changes using identified temporary coherent scatterers

2021 ◽  
Vol 32 (6) ◽  
pp. 1304-1317
Author(s):  
Hu Fengming ◽  
Wu Jicang
Entropy ◽  
2021 ◽  
Vol 23 (10) ◽  
pp. 1332
Author(s):  
Fan Yi ◽  
Peihua Qiu

To monitor the Earth’s surface, the satellite of the NASA Landsat program provides us image sequences of any region on the Earth constantly over time. These image sequences give us a unique resource to study the Earth’s surface, changes of the Earth resource over time, and their implications in agriculture, geology, forestry, and more. Besides natural sciences, image sequences are also commonly used in functional magnetic resonance imaging (fMRI) of medical studies for understanding the functioning of brains and other organs. In practice, observed images almost always contain noise and other contaminations. For a reliable subsequent image analysis, it is important to remove such contaminations in advance. This paper focuses on image sequence denoising, which has not been well-discussed in the literature yet. To this end, an edge-preserving image denoising procedure is suggested. The suggested method is based on a jump-preserving local smoothing procedure, in which the bandwidths are chosen such that the possible spatio-temporal correlations in the observed image intensities are accommodated properly. Both theoretical arguments and numerical studies show that this method works well in the various cases considered.


Author(s):  
R.F. Sognnaes

Sufficient experience has been gained during the past five years to suggest an extended application of microreplication and scanning electron microscopy to problems of forensic science. The author's research was originally initiated with a view to develop a non-destructive method for identification of materials that went into objects of art, notably ivory and ivories. This was followed by a very specific application to the identification and duplication of the kinds of materials from animal teeth and tusks which two centuries ago went into the fabrication of the ivory dentures of George Washington. Subsequently it became apparent that a similar method of microreplication and SEM examination offered promise for a whole series of problems pertinent to art, technology and science. Furthermore, what began primarily as an application to solid substances has turned out to be similarly applicable to soft tissue surfaces such as mucous membranes and skin, even in cases of acute, chronic and precancerous epithelial surface changes, and to post-mortem identification of specific structures pertinent to forensic science.


Author(s):  
J. Jacob ◽  
M.F.M. Ismail

Ultrastructural changes have been shown to occur in the urinary bladder epithelium (urothelium) during the life span of humans. With increasing age, the luminal surface becomes more flexible and develops simple microvilli-like processes. Furthermore, the specialised asymmetric structure of the luminal plasma membrane is relatively more prominent in the young than in the elderly. The nature of the changes at the luminal surface is now explored by lectin-mediated adsorption visualised by scanning electron microscopy (SEM).Samples of young adult (21-31 y old) and elderly (58-82 y old) urothelia were fixed in buffered 2% glutaraldehyde for 10 m and washed with phosphate buffered saline (PBS) containing Ca++ and Mg++ at room temperature. They were incubated overnight at 4°C in 0.1 M ammonium chloride in PBS to block any remaining aldehyde groups. The samples were then allowed to stand in PBS at 37°C for 2 h before incubation at 37°C for 30 m with lectins. The lectins used were concanavalin A (Con A), wheat germ agglutinin (WGA), phytohaemagglutinin (PHA) and pokeweed mitogen (PWM) at a concentration of 500 mg/ml in PBS at pH 7.A.


2005 ◽  
Vol 41 ◽  
pp. 15-30 ◽  
Author(s):  
Helen C. Ardley ◽  
Philip A. Robinson

The selectivity of the ubiquitin–26 S proteasome system (UPS) for a particular substrate protein relies on the interaction between a ubiquitin-conjugating enzyme (E2, of which a cell contains relatively few) and a ubiquitin–protein ligase (E3, of which there are possibly hundreds). Post-translational modifications of the protein substrate, such as phosphorylation or hydroxylation, are often required prior to its selection. In this way, the precise spatio-temporal targeting and degradation of a given substrate can be achieved. The E3s are a large, diverse group of proteins, characterized by one of several defining motifs. These include a HECT (homologous to E6-associated protein C-terminus), RING (really interesting new gene) or U-box (a modified RING motif without the full complement of Zn2+-binding ligands) domain. Whereas HECT E3s have a direct role in catalysis during ubiquitination, RING and U-box E3s facilitate protein ubiquitination. These latter two E3 types act as adaptor-like molecules. They bring an E2 and a substrate into sufficiently close proximity to promote the substrate's ubiquitination. Although many RING-type E3s, such as MDM2 (murine double minute clone 2 oncoprotein) and c-Cbl, can apparently act alone, others are found as components of much larger multi-protein complexes, such as the anaphase-promoting complex. Taken together, these multifaceted properties and interactions enable E3s to provide a powerful, and specific, mechanism for protein clearance within all cells of eukaryotic organisms. The importance of E3s is highlighted by the number of normal cellular processes they regulate, and the number of diseases associated with their loss of function or inappropriate targeting.


2019 ◽  
Vol 47 (6) ◽  
pp. 1733-1747 ◽  
Author(s):  
Christina Klausen ◽  
Fabian Kaiser ◽  
Birthe Stüven ◽  
Jan N. Hansen ◽  
Dagmar Wachten

The second messenger 3′,5′-cyclic nucleoside adenosine monophosphate (cAMP) plays a key role in signal transduction across prokaryotes and eukaryotes. Cyclic AMP signaling is compartmentalized into microdomains to fulfil specific functions. To define the function of cAMP within these microdomains, signaling needs to be analyzed with spatio-temporal precision. To this end, optogenetic approaches and genetically encoded fluorescent biosensors are particularly well suited. Synthesis and hydrolysis of cAMP can be directly manipulated by photoactivated adenylyl cyclases (PACs) and light-regulated phosphodiesterases (PDEs), respectively. In addition, many biosensors have been designed to spatially and temporarily resolve cAMP dynamics in the cell. This review provides an overview about optogenetic tools and biosensors to shed light on the subcellular organization of cAMP signaling.


Sign in / Sign up

Export Citation Format

Share Document