Investigation of fluorescein stain–based tear film breakup time test reliability in dogs in a clinical setting

Author(s):  
Lindsay D. Seyer ◽  
Robert W. Wills ◽  
Caroline M. Betbeze

Abstract OBJECTIVE To determine intra- and interobserver reliability of a fluorescein stain–based tear film breakup time (TFBUT) test as performed in a clinical environment with and without administration of a topical anesthetic. ANIMALS 21 privately owned dogs. PROCEDURES A randomized study design was used. Two independent observers that commonly perform the TFBUT test in clinical practice read the same description of TFBUT. Observers performed TFBUT testing for each dog before and after topical administration of 0.5% proparacaine solution in 4 testing periods with a 1-hour interval between periods. Intraclass correlation coefficient (ICC) analysis was used to assess inter- and intraobserver test reliability. Linear mixed models were used to assess the main effects of testing period, observer, eye, and presence of ophthalmic disorders and their interactions on TFBUT. RESULTS Mean TFBUT measurements performed by observer 1 and observer 2 were 5.9 seconds and 8.6 seconds, respectively, when adjusted for other effects in the model. Intraobserver ICC was poor for one observer and moderate for the other. Interobserver ICC was poor without use of topical anesthetic and slightly lower when anesthetic was used. Observer and testing period were each significantly associated with TFBUT; the measurements decreased and were more variable after multiple applications of fluorescein stain and proparacaine. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested tear film stability is negatively affected by topical administration of 0.5% proparacaine solution and repeated applications of fluorescein stain. The TFBUT test as performed in this study had poor to moderate reliability.

1991 ◽  
Vol 34 (5) ◽  
pp. 989-999 ◽  
Author(s):  
Stephanie Shaw ◽  
Truman E. Coggins

This study examines whether observers reliably categorize selected speech production behaviors in hearing-impaired children. A group of experienced speech-language pathologists was trained to score the elicited imitations of 5 profoundly and 5 severely hearing-impaired subjects using the Phonetic Level Evaluation (Ling, 1976). Interrater reliability was calculated using intraclass correlation coefficients. Overall, the magnitude of the coefficients was found to be considerably below what would be accepted in published behavioral research. Failure to obtain acceptably high levels of reliability suggests that the Phonetic Level Evaluation may not yet be an accurate and objective speech assessment measure for hearing-impaired children.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Minjeong Kim ◽  
Ja Young Oh ◽  
Seon Ha Bae ◽  
Seung Hyeun Lee ◽  
Won Jun Lee ◽  
...  

AbstractWe evaluated the reliability and validity of the 5-scale grading system to interpret the point-of-care immunoassay for tear matrix metalloproteinase (MMP)-9. Six observers graded red bands of photographs of the readout window in MMP-9 immunoassay kit (InflammaDry) two times with 2-week interval based on the 5-scale grading system (i.e. grade 0–4). Interobserver and intraobserver reliability were evaluated using intraclass correlation coefficients. The interobserver agreements were analyzed according to the severity of tear MMP-9 expression. To validate the system, a concentration calibration curve was made using MMP-9 solutions with reference concentrations, then the distribution of MMP-9 concentrations was analyzed according to the 5-scale grading system. Both intraobserver and interobserver reliability was excellent. The readout grades were significantly correlated with the quantified colorimetric densities. The interobserver variance of readout grades had no correlation with the severity of the measured densities. The band density continued to increase up to a maximal concentration (i.e. 5000 ng/mL) according to the calibration curve. The difference of grades reflected the change of MMP-9 concentrations sensitively, especially between grade 2 and 4. Together, our data indicate that the subjective 5-scale grading system in the point-of-care MMP-9 immunoassay is an easy and reliable method with acceptable accuracy.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Aristeidis A. Villias ◽  
Stefanos G. Kourtis ◽  
Hercules C. Karkazis ◽  
Gregory L. Polyzois

Abstract Background The replica technique with its modifications (negative replica) has been used for the assessment of marginal fit (MF). However, identification of the boundaries between prosthesis, cement, and abutment is challenging. The recently developed Digital Image Analysis Sequence (DIAS) addresses this limitation. Although DIAS is applicable, its reliability has not yet been proven. The purpose of this study was to verify the DIAS as an acceptable method for the quantitative assessment of MF at cemented crowns, by conducting statistical tests of agreement between different examiners. Methods One hundred fifty-one implant-supported experimental crowns were cemented. Equal negative replicas were produced from the assemblies. Each replica was sectioned in six parts, which were photographed under an optical microscope. From the 906 standardized digital photomicrographs (0.65 μm/pixel), 130 were randomly selected for analysis. DIAS included tracing the profile of the crown and the abutment and marking the margin definition points before cementation. Next, the traced and marked outlines were superimposed on each digital image, highlighting the components’ boundaries and enabling MF measurements. One researcher ran the analysis twice and three others once, independently. Five groups of 130 measurements were formed. Intra- and interobserver reliability was evaluated with intraclass correlation coefficient (ICC). Agreement was estimated with the standard error of measurement (SEM), the smallest detectable change at the 95% confidence level (SDC95%), and the Bland and Altman method of limits of agreement (LoA). Results Measured MF ranged between 22.83 and 286.58 pixels. Both the intra- and interobserver reliability were excellent, ICC = 1 at 95% confidence level. The intra- and interobserver SEM and SDC95% were less than 1 and 3 pixels, respectively. The Bland–Altman analysis presented graphically high level of agreement between the mean measurement of the first observer and each of the three other observers’ measurements. Differences between observers were normally distributed. In all three cases, the mean difference was less than 1 pixel and within ± 3 pixels LoA laid at least 95% of differences. T tests of the differences did not reveal any fixed bias (P > .05, not significant). Conclusion The DIAS is an objective and reliable method able to detect and quantify MF at ranges observed in clinical practice.


Author(s):  
Emma Černis ◽  
Jessica C. Bird ◽  
Andrew Molodynski ◽  
Anke Ehlers ◽  
Daniel Freeman

Abstract Background: Catastrophic cognitive appraisals, similar to those in anxiety disorders, are implicated in depersonalisation, a form of dissociation. No scales exist to measure appraisals of dissociative experiences. Dissociation is common in psychosis. Misinterpretations of dissociative experiences may maintain psychotic symptoms. Therefore, assessing appraisals in this context may be valuable. Aims: The primary aim was to develop a measure of key appraisals of dissociation in psychosis. Secondary aims were to test the relationship between appraisals and psychotic experiences (paranoia and hallucinations), and determine whether appraisals explain additional variance in psychotic symptoms above dissociative symptoms. Method: Fifty items were generated from transcripts of interviews with patients. The measure was developed and psychometrically validated via factor analysis of data from 9902 general population participants and 1026 patients with psychosis. Convergent validity, test–re-test reliability, and internal reliability were assessed. Regression analyses tested relationships with psychotic symptoms. Results: A 13-item single-factor measure was developed. Factor analysis indicated good model fit [χ2(65) = 247.173, comparative fit index (CFI) = 0.960, root mean square error of approximation (RMSEA) = 0.052]. The scale had good convergent validity with a rumination (non-clinical: r = 0.71; clinical: r = 0.73) and dissociation measure (r = 0.81; r = 0.80), high internal consistency (α = 0.93; α = 0.93), and excellent 1-week test–re-test reliability [intraclass correlation (ICC) = 0.90]. It explained variance in psychotic symptoms (paranoia: 36.4%; hallucinations: 35.0%), including additional variance compared with dissociation alone (paranoia: 5.3%; hallucinations: 2.3%). Conclusions: The Cognitive Appraisals of Dissociation in Psychosis (CAD-P) measure is a psychometrically robust scale identifying appraisals of dissociative experiences in psychosis and is associated with the presence of psychotic experiences. It is likely to prove useful for clinical assessment and research.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Daniel Kadlec ◽  
Matthew J. Jordan ◽  
Leanne Snyder ◽  
Jacqueline Alderson ◽  
Sophia Nimphius

Abstract Purpose To examine the test re-test reliability of isometric maximal voluntary contractions (MVC) of hip adduction (ADDISO), hip abduction (ABDISO), and multijoint leg extension (SQUATISO) in sub-elite female Australian footballers. Methods Data were collected from 24 sub-elite female Australian footballers (age 22.6 ± 4.5 years; height 169.4 ± 5.5 cm; body mass 66.6 ± 8.0 kg; 4.5 ± 4.4 years sport-specific training; 2.5 ± 2.0 years unstructured resistance training) from the same club on two non-consecutive days. Participants performed three isometric MVCs of ADDISO, ABDISO, and SQUATISO. The SQUATISO was performed at 140° knee flexion with a vertical trunk position and ADDISO and ABDISO measures were performed in a supine position at 60° of knee flexion and 60° hip flexion. Reliability was assessed using paired t tests and the intraclass correlation coefficient (ICC) with 95% confidence intervals (CI), typical error (TE), and coefficient of variation (CV%) with 95% CI. Results SQUATISO peak force (ICC .95; CV% 4.1), ABDISO for left, right, and sum (ICC .90–.92; CV% 5.0–5.7), and ADDISO for left, right, and sum (ICC .86–.91; CV% 6.2–6.9) were deemed acceptably reliable based on predetermined criteria (ICC ≥ .8 and CV% ≤ 10). Conclusion SQUATISO, ABDISO, and ADDISO tests demonstrated acceptable reliability for the assessment of peak force in sub-elite female Australian footballers, suggesting these assessments are suitable for muscle strength testing and monitoring adaptations to training.


Ultrasound ◽  
2021 ◽  
pp. 1742271X2110224
Author(s):  
Sonja Brennan ◽  
David Watson ◽  
Michal Schneider ◽  
Donna Rudd ◽  
Yogavijayan Kandasamy

Introduction The study objectives were to develop standard charts for fetal renal artery blood flow to define normal ranges and to assess the reliability of the measurements. Methods This prospective, longitudinal study reviewed 72 low-risk singleton pregnancies who had serial ultrasound examinations. Pulse wave Doppler was used to obtain the resistivity and pulsatility indices of the fetal renal arteries. Standard charts of the fetal renal arteries were created using mixed effects modelling and the intra- and interobserver reliability for the renal blood flow measurements was analysed. Results Standard charts of the normal ranges of the renal artery resistive index (RI) and pulsatility index (PI) of the fetal renal arteries were created. The 3rd, 5th, 10th, 50th, 90th, 95th and 97th centiles were calculated. The intraclass correlation coefficient was acceptable for intraobserver reliability (RI = 0.66, PI = 0.88) and poor for interobserver reliability (RI = 0.11, PI = −0.56). Conclusions These novel charts demonstrate the change of the fetal renal artery blood flow during pregnancy. These may be used in clinical practice to detect variations from these normal ranges and be useful in future studies of kidney function projection.


Author(s):  
Daniel Rojas-Valverde ◽  
José Pino-Ortega ◽  
Rafael Timón ◽  
Randall Gutiérrez-Vargas ◽  
Braulio Sánchez-Ureña ◽  
...  

The extensive use of wearable sensors in sport medicine, exercise medicine, and health has increased the interest in their study. That is why it is necessary to test these technologies’ efficiency, effectiveness, agreement, and reliability in different settings. Consequently, the purpose of this article was to analyze the magnetic, angular rate, and gravity (MARG) sensor’s test-retest agreement and reliability when assessing multiple body segments’ external loads during off-road running. A total of 18 off-road runners (38.78 ± 10.38 years, 73.24 ± 12.6 kg, 172.17 ± 9.48 cm) ran two laps (1st and 2nd Lap) of a 12 km circuit wearing six MARG sensors. The sensors were attached to six different body segments: left (MPLeft) and right (MPRight) malleolus peroneus, left (VLLeft) and right (VLRight) vastus lateralis, lumbar (L1-L3), and thorax (T2-T4) using a special neoprene suit. After a principal component analysis (PCA) was performed, the total data set variance of all body segments was represented by 44.08%–70.64% for the 1st PCA factor considering two variables, Player LoadRT and Impacts, on L1-L3, respectively. These two variables were chosen among three total accelerometry-based external load indicators (ABELIs) to perform the agreement and reliability tests due to their relevance based on PCAs for each body segment. There were no significant differences between laps in the Player LoadRT or Impacts ( p > 0.05, trivial). The intraclass correlation and lineal correlation showed a substantial to almost perfect over-time test consistency assessed via reliability in both Player LoadRT and Impacts. Bias and t-test assessments showed good agreement between Laps. It can be concluded that MARGs sensors offer significant test re-test reliability and good agreement when assessing off-road kinematics in the six different body segments.


Author(s):  
M. F. R. Powell-Bowns ◽  
E. Oag ◽  
D. Martin ◽  
N. D. Clement ◽  
C. E. H. Scott

Abstract Introduction The aim of this study was to identify factors associated with the level of periprosthetic fracture involving a cemented polished tapered stem: Vancouver B or Vancouver C. Methods A retrospective cohort study of 181 unilateral periprosthetic fractures involving Exeter stems was assessed by three observers (mean age 78.5, range 39–103; mean BMI 27.1, 17–39; 97 (54%) male). Patient demographics, deprivation scores, BMI and time since primary prosthesis were recorded. Femoral diameter, femoral cortical thickness, Dorr classification and distal cement mantle length were measured from calibrated radiographs. Interobserver reliability was calculated using intraclass correlation coefficients (ICCs). Univariate and multivariate analysis was performed to identify associations with Vancouver B or C fractures. Results 160/181 (88%) Vancouver B and 21/181 (12%) Vancouver C-level fractures occurred at a mean of 5.9 ± 5.4 years (0.2–26.5) following primary surgery. Radiographic measurements demonstrated excellent agreement (ICC > 0.8, p < 0.001). Mortality was significantly higher following Vancouver C compared to B fractures: 90 day 14/160 Vs 5/21 (p = 0.05); 1 year 29/160 Vs 8/21 (p = 0.03). Univariate analysis demonstrated that Vancouver C fractures were associated with female sex, bisphosphonate use, cortical bone thickness, and distal cement mantle length (p < 0.05). On multivariate analysis, only female sex was an independent predictor of Vancouver C-level fractures (R2 =0.354, p = 0.005). Conclusion Most PFFs involving the Exeter stem design are Vancouver B-type fractures and appear to be independent of osteoporosis. In contrast, Vancouver C periprosthetic fractures display typical fragility fracture characteristics and are associated with female sex, thinner femoral cortices, longer distal cement mantles and high mortality.


1997 ◽  
Vol 64 (5) ◽  
pp. 270-276 ◽  
Author(s):  
Johanne Desrosiers ◽  
Annie Rochette ◽  
Réjean Hébert ◽  
Gina Bravo

Several dexterity tests have been developed, including the Minnesota Rate of Manipulation Test (MRMT) and a new version, the Minnesota Manual Dexterity Test (MMDT). The objectives of the study were: a) to verify the test-retest reliability of the MMDT; b) to compare the MRMT and the MMDT; c) to study the concurrent validity of the MMDT; and d) to establish reference values for elderly people with the MMDT. Two hundred and forty-seven community-living healthy elderly were evaluated with the MMDT, and two other dexterity tests, the Box and Block Test (BBT) and the Purdue Pegboard (PP). Thirty-five of them were evaluated twice with the MMDT and 44 were evaluated with both the MMDT and MRMT. The results show that the test-retest reliability of the MMDT is acceptable to high (intraclass correlation coefficients of 0.79 to 0.87, depending on the subtest) and the validity of the test is demonstrated by significant correlations between the MMDT, the BBT and the PP (0.63 to 0.67). There is a high correlation (0.85 to 0.95) between the MMDT and the MMRT in spite of different results. The reference values will help occupational therapists to differentiate better between real dexterity difficulties and those that may be attributed to normal aging.


2011 ◽  
Vol 8 (8) ◽  
pp. 1117-1123 ◽  
Author(s):  
Deborah A. Cohen ◽  
Claude Setodji ◽  
Kelly R. Evenson ◽  
Phillip Ward ◽  
Sandra Lapham ◽  
...  

Background:The Systematic Observation of Play and Recreation in Communities (SOPARC) was designed to estimate the number and characteristics of people using neighborhood parks by assessing them 4 times/day, 7 days/week. We tested whether this schedule was adequate and determined the minimum number of observations necessary to provide a robust estimate of park user characteristics and their physical activity levels.Methods:We conducted observations every hour for 14 hours per day during 1 summer and 1 autumn week in 10 urban neighborhood parks: 2 each in Los Angeles, CA; Albuquerque, NM; Columbus, OH; Durham, NC; and Philadelphia, PA. We counted park users by gender, age group, apparent race/ethnicity, and activity level. We used a standardized Cronbach’s alpha and intraclass correlation coefficients to test the reliability of using fewer observations.Results:We observed 76,632 individuals, an average of 547/park/day (range 155−786). Interobserver reliability ranged from 0.80 to 0.99. Obtaining a robust estimate of park user characteristics and their physical activity required a schedule of 4 days/week, 4 times/day.Conclusion:An abbreviated schedule of SOPARC was sufficient for estimating park use, park user characteristics, and physical activity. Applying these observation methods can augment physical activity surveillance.


Sign in / Sign up

Export Citation Format

Share Document