Critical Mass Flow Rate and Pressure Distribution through Horizontal Adiabatic Capillary Tubes for the Flow of R-134A

Author(s):  
Puya Javidmand ◽  
Klaus Hoffmann
Author(s):  
A. Nouri-Borujerdi ◽  
P. Javidmand

This paper presented a numerical study that predicts critical mass flow rate, pressure, vapor quality, and void fraction along a very long tube with small diameter or capillary tub under critical condition by the drift flux model. Capillary tubes are simple expansion devices and are necessary to design and optimization of refrigeration systems. Using dimensional analysis by Buckingham’s π theory, some generalized correlations are proposed for prediction of flow parameters as functions of flow properties and tube sizes under various critical conditions. This study is performed under the inlet pressure in the range of 0.8 ≤ pin ≤ 1.5Mpa, subcooling temperature between 0 ≤ ΔTsub ≤ 10 °C. The tube diameter is in the range of 0.5 ≤ D ≤ 1.5mm and tube length between 1 ≤ L ≤ 2m for water, ammonia, refrigerants R-12, R-22 and R-134 as working fluids. Comparison between the results of the present work and some experimental data indicates a good agreement. Cluster of data close to the fitted curves also shows satisfactory results.


2014 ◽  
Vol 960-961 ◽  
pp. 643-647
Author(s):  
Yan Sheng Xu

A stepped capillary tube consisting of two serially connected capillary tubes with different diameters is invented to replace the conventional expansion device. The mass flow rate of refrigerant R410A in stepped capillary tubes with different size were tested. The model of stepped capillary tube is proposed, and its numerical algorithm for tube length and mass flow rate is developed. The experimental results show that the performance comparing between stepped capillary tube system and capillary tube assembly system, the cooling capacity is reduced by 0.3%, the energy efficiency ratio (EER) is equal to each other, the heating capacity is increased by 0.3%, the coefficient of performance (COP) is decreased by 0.3%. That is to say, the performance index of the two kinds of throttle mechanism is almost identical. It indicates that the stepped capillary tube can replace the capillary tube assembly in the R410A heat pump type air conditioner absolutely. The model is validated with experimental data, and the results show that the model can be used for sizing and rating stepped capillary tube.


Author(s):  
M. K. Mittal ◽  
R. Kumar ◽  
A. Gupta

The objective of this study is to investigate the effect of coiling on the flow characteristics of R-407C in an adiabatic spiral capillary tube. The characteristic coiling parameter for a spiral capillary tube is the coil pitch; hence, the effect of the coil pitch on the mass flow rate of R-407C was studied on several capillary tube test sections. It was observed that the coiling of the capillary tube significantly reduced the mass flow rate of R-407C in the adiabatic spiral capillary tube. In order to quantify the effect of coiling, the experiments were also conducted for straight a capillary tube, and it was observed that the coiling of the capillary tube reduced the mass flow rate in the spiral tube in the range of 9–18% as compared with that in the straight capillary tube. A generalized nondimensional correlation for the prediction of the mass flow rates of various refrigerants was developed for the straight capillary tube on the basis of the experimental data of R-407C of the present study, and the data of R-134a, R-22, and R-410A measured by other researchers. Additionally, a refrigerant-specific correlation for the spiral capillary was also proposed on the basis of the experimental data of R-407C of the present study.


Author(s):  
S. F. Goh ◽  
S. Kusadomi ◽  
S. R. Gollahalli

The main purpose of this study was to comprehend the effects of burner diameter and fuel type on smoke point characteristics of a hydrocarbon diffusion flame and its radiation emission. The critical mass flow rate of pure fuel at this smoke point was measured. At nine different fractions of the critical mass flow rate, nitrogen gas was supplied along with the fuel to achieve smoke point. At each condition, flame radiation and flame height were measured. The axial radiation profile at the critical fuel mass flow rate for one burner was also measured. Three fuels of differing sooting propensities were used: ethylene (C2H4), propylene (C3H6), and propane (C3H8). Three different burners with inner diameters of 1.2 mm, 3.2 mm and 6.4 mm were used. Results showed that propylene had the highest critical fuel flow rate and the highest nitrogen dilution required to suppress smoking and total flame radiation, followed by ethylene and propane. For all fuels, the curves of nitrogen flow rate required for smoke suppression versus fuel flow rate exhibited a skewed bell shape. The variation of Reynolds number at the critical fuel mass flow rate with the burner diameter showed a linear relation. On the other hand, the variation of total flame radiation with burner diameter was nonlinear.


Author(s):  
Saad A. Ahmed

Centrifugal compressors or blowers are widely used in many industrial applications. However, the operation of such systems is limited at low-mass flow rates by self-excited flow instabilities which could result in rotating stall or surge of the compressor. These instabilities will limit the flow range in which the compressor or the blower can operate, and will also lower their performance and efficiency. Experimental techniques were used to investigate a model of radial vaneless diffuser at stall and stall-free operating conditions. The speed of the impeller was kept constant, while the mass flow rate was reduced gradually to study the steady and unsteady operating conditions of the compressor. Additional experiments were made to investigate the effects of reducing the exit flow area on the inception of stall. The results indicate that the instability in the diffuser was successfully delayed to a lower flow coefficient when throttle rings were attached to either one or both of the diffuser walls (i.e., to reduce the diffuser exit flow area). The results also showed that an increase of the blockage ratio improves the stability of the system (i.e., the critical mass flow rate could be reduced to 50% of its value without blockage). The results indicate that the throttle rings could be an effective method to control stall in radial diffusers.


2020 ◽  
Vol 118 ◽  
pp. 269-278 ◽  
Author(s):  
Thiago Torres Martins Rocha ◽  
Cleison Henrique de Paula ◽  
Vinícius Melo Cangussu ◽  
Antônio Augusto Torres Maia ◽  
Raphael Nunes de Oliveira

2017 ◽  
Vol 25 (04) ◽  
pp. 1730004 ◽  
Author(s):  
Mehdi Rasti ◽  
Ji Hwan Jeong

Capillary tubes are widely used as expansion devices in small-capacity refrigeration systems. Since the refrigerant flow through the capillary tubes is complex, many researchers presented empirical dimensionless correlations to predict the refrigerant mass flow rate. A comprehensive review of the dimensionless correlations for the prediction of refrigerants mass flow rate through straight and coiled capillary tubes depending on their geometry and adiabatic or diabatic capillary tubes depending on the flow configurations has been discussed. A comprehensive review shows that most of previous dimensionless correlations have problems such as discontinuity at the saturated lines or ability to predict the refrigerant mass flow rate only for the capillary tube subcooled inlet condition. The correlations suggested by Rasti et al. and Rasti and Jeong appeared to be general and continuous and these correlations can be used to predict the refrigerant mass flow rate through all the types of capillary tubes with wide range of capillary tube inlet conditions including subcooled liquid, two-phase mixture, and superheated vapor conditions.


Author(s):  
Kitti Nilpueng ◽  
Somchai Wongwises

In this study, the flow mechanisms of HFC-134a and HFC-410A, including flow pattern, pressure distribution, temperature distribution, and mass flow rate inside short-tube orifice are presented and compared under the same working temperature. The test runs are performed at condenser temperature ranging between 35 and 45°C, evaporator temperature ranging between 2 and 12°C, and degree of subcooling ranging between 1 and 12 °C. The results show that the temperature distribution along the short-tube orifice obtained from HFC-410A is slightly higher than that obtained from HFC-134a. On the other hand, the pressure distribution between both refrigerants shows the large difference. It is also found that the tendency of mass flow rate obtained from HFC-134a almost coincides with those obtained HFC-410A as the operating conditions and short-tube orifice size are varied. However, the average mass flow rate of HFC-134a is slightly lower than that of HFC-410A.