scholarly journals Comparative analysis of the power indices of the lower extremity muscles in the patients after total endoprosthesis of the hip joint, depending on surgical access

2019 ◽  
Vol 86 (10) ◽  
pp. 57-61
Author(s):  
G. I. Gertsen ◽  
I. A. Lazarev ◽  
D. A. Gorban

Objective. To compare the power characteristics of the lower extremity muscles after endoprosthesis of a hip joint in application of anterior-lateral and posterior-lateral surgical accesses. Materials and methods. Biomechanical investigation in accordance to electrotensodynamometry in 120 patients preoperatively, in early (in 3 weeks) and late (in 4 mo) period after endoprosthesis of a hip joint. Operative intervention was performed, using anterior-lateral operative access in 60 patients, and applying posterior-lateral - in 60 patients as well. Conclusion. There was established, that restoration of necessary muscular balance after endoprosthesis of a hip joint is guaranteed by application of anterior-lateral and posterior-lateral access, but the terms of restoration of muscles of various groups are differed.

2014 ◽  
Vol 664 ◽  
pp. 423-428
Author(s):  
Mauricio Plaza Torres ◽  
William Aperador

Hip disarticulation is an amputation through the hip joint capsule, removing the entire lower extremity, with closure of the remaining musculature over the exposed acetabulum. Tumors of the distal and proximal femur were treated by total femur resection; a hip disarticulation sometimes is performance for massive trauma with crush injuries to the lower extremity. This article discusses the design a system for rehabilitation of a patient with bilateral hip disarticulations. The prosthetics designed allowed the patient to do natural gait suspended between parallel articulate crutches with the body weight support between the crutches. The care of this patient was a challenge due to bilateral amputations at such a high level and the special needs of a patient mobility.


2020 ◽  
Vol 27 (3) ◽  
pp. 60-66
Author(s):  
Hovakim A. Aleksanyan ◽  
Hamlet A. Chragyan ◽  
Sergey V. Kagramanov ◽  
Nikolay V. Zagorodniy

The aim of the study is to demonstrate, using a clinical example, the possibility of treating a patient with a severe acetabular defect by performing a one-stage revision arthroplasty using an individual design. Materials and methods. A 45-year-old female patient was admitted with complaints of pain, limitation of movement in the right hip joint, and gait disturbance. From anamnesis at the age of 5 years, reconstructive operations of the hip joints were performed. In 1991, CITO performed primary total arthroplasty of the right hip joint with an endoprosthesis from ESKA Implants. In 1998, due to the instability of the acetabular component of the total endoprosthesis of the right hip joint, revision arthroplasty was performed, and the cup was placed with a cement fixation. In 2001, for left-sided dysplastic coxarthrosis, primary total arthroplasty of the left hip joint was performed. In 2012, due to the instability of the total endoprosthesis of the left hip joint, revision arthroplasty was performed using an ESI anti-protrusion ring (ENDOSERVICE) with a cement cup and a Zweimller-type femoral component; the femur defect was repaired using a fresh frozen cortical graft. In October 2019, instability of the total endoprosthesis of the right hip joint was revealed, for which revision endoprosthetics was performed using an individual acetabular component. Results. The HHS index before revision arthroplasty was 21 points, after 1 month after surgery 44 points, after 3 months after surgery 65, after 6 months 82. Quality of life was assessed according to the WOMAC scale: before surgery 73 points, after 1 month after surgery 54 points, after 3 months 31, after 6 months 15 points. At the time of the last consultation, the patient moves with a cane, lameness persists, associated with scar reconstruction and atrophy of the gluteal muscles. Conclusion. The use of individual structures allows to restore the support ability of the lower limb and the function of the hip joint in the case of an extensive defect of the pelvic bones of the pelvic discontinuity type.


Medicina ◽  
2019 ◽  
Vol 55 (9) ◽  
pp. 517 ◽  
Author(s):  
Katarzyna Jochymczyk-Woźniak ◽  
Katarzyna Nowakowska ◽  
Jacek Polechoński ◽  
Sandra Sładczyk ◽  
Robert Michnik

Background and objectives: Virtual reality (VR) is increasingly often finding applications in physiotherapy and health promotion. Recent years have seen the use of advanced technologies in the promotion of physical activity (PA) in society. New simulators, e.g., treadmills, enable the performance of PA (e.g., locomotive movements) in VR (artificially created virtual world). The question of how such movements are similar to natural forms of human locomotion (march, run) inspired the comparative analysis of physiological gait and gait in VR on a multidirectional Omni treadmill. Materials and Methods: The tests involved the use of the BTS Smart system for the triplanar analysis of motion. The test involved 10 healthy females aged 20–24 (weight: 52 ± 3.1 kg, height 162 ± 5.4 cm). Measurements were performed at two stages. The first stage involved the standard assessment of physiological gait, whereas the second was focused on gait forced by the Omni treadmill. The following gait parameters were analyzed: Flexion-extension in the ankle, knee joint and hip joint, rotation in the hip joint and knee joint, foot progression, adduction-abduction in the knee joint and hip joint, pelvic obliquity, pelvic tilt, pelvic rotation as well as energy expenditure and the movement of the body center of mass. Results: The analysis of the test results revealed the existence of differences in the kinematics of physical gait and gait on the treadmill. The greatest differences were recorded in relation to the dorsal-plantar flexion in the ankle, the foot progression, the rotation of the knee joint, pelvic tilt and rotation. In addition, the gait on the treadmill is characterized by the longer duration of the stance phase and reduced ranges of the following movements: Flexion-extension in the ankle, knee joint and hip joint, adduction-abduction in the hip joint as well as rotation in the ankle and hip joint. The values of potential, kinetic and total energy recorded in relation to forced gait are significantly lower than those of physiological gait. Conclusions: Because of the fact that the parameters of gait on the Omni platform vary significantly from the parameters of physical gait, the application of the Omni treadmill in the re-education of gait during rehabilitation should be treated with considerable care. Nonetheless, the treadmill has adequate potential to become a safe simulator enabling active motion in VR using locomotive movements.


2006 ◽  
Vol 49 (7) ◽  
pp. 964-969 ◽  
Author(s):  
Jill P. Ginsberg ◽  
Shesh N. Rai ◽  
Claire A. Carlson ◽  
Anna T. Meadows ◽  
Pamela S. Hinds ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document