Discussion on Energy Conservation and Environmental Protection Measures for Building Green Power Plants

节能环保 ◽  
2019 ◽  
Vol 4 (1) ◽  
pp. 6-7
Author(s):  
Nuandong Song ◽  

With the continuous development of the national economy, the demand for power and energy has further increased. While meeting the concept of production and living electricity consumption, the implementation of energy conservation and environmental protection has become a major problem that must be considered in the development of power plants. This paper starts with the analysis of the relationship between the power plant and the environment, and gives the corresponding energy saving and environmental protection measures for the power plant, hoping to have some reference significance for the green development of the power plant.

Author(s):  
Dengji Zhou ◽  
Tingting Wei ◽  
Shixi Ma ◽  
Huisheng Zhang ◽  
Di Huang ◽  
...  

Digital power plant is the theory and method to improve the operating quality of power plant by quantifying, analyzing, controlling and deciding the physical and working objects of power plants in the whole life cycle. Signals and management information of power plants will be digitized, so as to realize information exchange reliably and accurately and large-scale distributed resource sharing based on the network technology. Then optimization decisions and scientific guidance for plant operation will be proposed by intelligent expert system based on the digital resources. Therefore, the foundation of digital power plant is system modeling and performance analysis. However, there are some problems in the process of the modeling performance analysis of digital power plant. For instance, each unit of the system model has different dimensions and different type of mathematical description, and the data or information used for modeling are defined differently and belong to different enterprises, who do not want to share their information. Metamodeling is potential to solve these problems. It defines the specification to describe a unit and the relationship between different elements. Compared with traditional modeling methodologies for thermal systems, metamodeling makes the model more standardized, and the relationship of the model elements is more explicit and better understood by the co-simulation partners. In this paper, the collaborative modeling and simulation platform for digital power plant has been established based on the metamodeling method and the performance of the target plant has been analyzed from different aspects via field data. The metamodeling method consists of three parts: syntax definition, model development and algorithm definition. The result shows that the collaborate modeling and simulation platform can be used to reduce costs, decrease equipment failure rate, and improve plant output, so as to guarantee the safety and increase economics.


2020 ◽  
Vol 13 (2) ◽  
pp. 157-168
Author(s):  
Aslan Khuseinovich Abashidze ◽  
Vladimir Mikhailovich Filippov ◽  
Alexander Mikhailovich Solntsev

Abstract States have sovereign rights that allow them to construct nuclear power plants. Moreover, engaging with nuclear power generation makes possible the achievement of the Sustainable Development Goals (2016–30) in combatting climate change, paramount to the Paris Agreement’s initiatives. In the same vein, however, constructing and operating power plants pose strict dangers to both general safety of the public and to national security. Thus, plant operations should strictly abide by the International Atomic Energy Agency (IAEA) standards and international law. As a result, it is important to consider the potential transboundary impacts of nuclear power plants and to conduct an appropriate transboundary environmental impact assessment (EIA). The article examines the construction of the Ostrovets Nuclear Power Plant by Belarus, close to the border of the Republic of Lithuania. The question in focus, however, is as follows: what international procedure can be used to coordinate issues of potentially negative transboundary impacts? Lithuania, in order to avoid the operation of the nuclear power plant, thus sought peaceful settlement of the dispute making use of the dispute resolution mechanisms based on international environmental agreements. The authors of this study show that the treaty bodies, established on the basis of international environmental agreements, provide important assistance in this matter in coordination with the IAEA. The use of these quasi-judicial means of resolving interstate disputes proves effective in pursuing a compromise between economic development and environmental protection. In the absence of such mechanisms at a universal level, one should consider utilizing such mechanisms in other regions of the world.


2020 ◽  
Author(s):  
Paolo Basile ◽  
Roberto Brogi ◽  
Favaro Lorenzo ◽  
Tiziana Mazzoni

<p><span><span>Social consensus is a </span><span>condition precedent for any intervention having an impact on the territory, such as geothermal power plants. Therefore, private investors studied and proposed innovative solution for the exploitation of the medium enthalpy geothermal resource, with “zero emissions” in atmosphere, with the target of minimizing its environmental impact. “Montenero” project, developed by GESTO Italia, complies with this precondition.</span></span></p><p><span><span>The area covered b</span><span>y the exploration and exploitation permit is located on the northern edge of the great geothermal anomaly of Mt. Amiata (Tuscany), about 10 km north of the geothermal field of Bagnore, included in the homonymous Concession of Enel Green Power.</span></span></p><p><span><span>The geological - structural setting of the area around the inactive volc</span><span>ano of Mt. Amiata has been characterized by researches for the geothermal field of Bagnore, carried out by Enel Green Power over the years. The geothermal reservoir is present in the limestone and evaporitic rocks of the “Falda Toscana”, below which stands the Metamorphic Basement, as testified by the wells of geothermal field of Bagnore. The foreseen reservoir temperature at the target depth of 1.800 m is 140 °C, with an incondensable gas content of 1,8% by weight.</span></span></p><p><span><span>The project was presented to the authorities in 2013 and it is </span><span>now undergoing exploitation authorization and features the construction of a 5 MW ORC (Organic Ranking Circle) binary power plant. The plant is fed by three production wells for a total mass flow rate of 700 t/h. The geothermal fluid is pumped by three ESPs (Electrical Submersible Pump) keeping the geothermal fluid in liquid state from the extraction through the heat exchangers to its final reinjection three wells.</span></span></p><p><span><span>The reinjection temperature is 70 °C and the circuit pressure is maintained above the </span><span>incondensable gas bubble pressure, i.e. 40 bar, condition which prevents also the formation of calcium carbonate scaling. The confinement of the geothermal fluid in a “closed loop system” is an important advantage from the environmental point of view: possible pollutants presented inside the geothermal fluid are not released into the environment and are directly reinjected in geothermal reservoir.</span></span></p><p><span><span>The </span><span>environmental authorization procedure (obtained) has taken into account all the environmental aspects concerning the natural matrices (air, water, ground, ...) potentially affected by the activities needed for the development, construction and operation of “Montenero” ORC geothermal power plant. A numerical modeling was designed and applied in order to estimate the effect of the cultivation activity and to assess the reinjection overpressure (seismic effect evaluation). The project also follows the “best practices” implemented in Italy by the “Guidelines for the usage of medium and high enthalpy geothermal resources” prepared in cooperation between the Ministry of Economic Development and the Ministry of the Environment.</span></span></p>


2021 ◽  
Author(s):  
Athanassios A. Argiriou ◽  
Constaninos Kolokythas ◽  
Vassiliki Kotroni

Wind energy power plants are vulnerable, among others, to abrupt weather changes caused especially by thunderstorms associated with lightning activity and the accompanying severe wind gusts and rapid wind direction changes. Due to a range of damages such phenomena may cause, the knowledge of the relationship between the storm systems and the produced wind field is essential to establish a wind power plant during the construction and operation phase as well. In first part of this study, the relationship of severe wind gusts in regard to lightning activity in a wind farm in a hilly region of western Greece is investigated. Wind data come from wind turbines covering a period of three years (2012-2014), while the corresponding lightning data from the ZEUS lighting detection network. The analysis shows that wind gusts are well correlated to lightning strikes. Furthermore, correlation maximizes during winter when well organized weather systems affect the area and minimum in summer as a result of local storms due to thermal instability. In the second part the study focuses on the development of an ANN model in order to forecast these two parameters in a horizon of 1-h ahead by using except for the wind data, four variables namely CAPE, TTI, wind speed at the 500 hPa isobaric level and the 0-6 km vertical wind shear. The results revealed that proposed model could be considered as a promising tool in simulating the occurrence both of wind gusts and lightning flashes providing a relatively good evidence of the possibility of occurrence of such events.


2021 ◽  
Author(s):  
Mohammad Amin Ghannadi ◽  
Matin Shahri ◽  
Amir Reza Moradi

Abstract Nowadays, air pollution and its negative effects on human health is regarded as one of the most fundamental problems in the world. Iran as a developing country also deals with the issue of air pollution. Nitrogen dioxide (NO2) as one of the air pollutants leads to serious damage to the human respiratory system. The power plants are recognized as one of the main sources of producing NO2. In this research, the effect of NO2 produced in Shazand power plant on the air pollution in Arak metropolitan area, as one of the most polluted cities in Iran will be investigated using a third-order rational mathematical model. Sentinel-5 satellite images have been applied to monitor NO2 in the study area during the two years 2020-2019. The results indicate that the proposed model has been successful to model the relationship between the amount of NO2 produced in Shazand power plant and its propagation in Arak city using a set of control points with the values of RMSE, MAE and R2 equal to 6-10×2.1, 6-10×1.3 and 0.99 respectively. The results of model validation using check points with the values of RMSE, MAE and R2 equal to6-10×1.7 , 6-10×1.1 and 0.99 respectively indicate that the model can also be applied to any data location in the study area.


Eos ◽  
2015 ◽  
Vol 96 ◽  
Author(s):  
Randy Showstack

In a case about power plant emissions, arguments focused on whether the Environmental Protection Agency properly interpreted a regulation and on dramatically different cost-benefit analyses.


2012 ◽  
Vol 155-156 ◽  
pp. 912-916
Author(s):  
Ai Juan Hu

The state council about speeding up the development of tourism opinion clearly put to greatly promote the tourism industry of energy saving and emission reduction, five years to star hotel, A level scenic area water electricity consumption by 20%. This has long been called is low carbon industry for tourism, facing a great challenge. This paper by analyzing think though tourism is low carbon industry, still has certain reduction space, can from the government and industry management department, tourism management department, tourists in such aspects as take effective measures to achieve a low carbon tourism, promote energy conservation and environmental protection.


Author(s):  
MARC BOUISSOU ◽  
YANNICK LEFEBVRE

Electricité de France produces about 75% of its electricity with nuclear power plants. Some hydraulic plants and most fossil fuel power plants are used to pass electricity consumption peaks. Therefore these facilities are required only intermittently. For such systems, a breakdown does not result in a production loss during a standby period. This particular feature is not taken into account by conventional availability evaluation methods. The objective of this paper is to introduce a definition of availability which holds in such a context, and to describe a mathematical method suited to the calculation of this new definition of availability.


Sign in / Sign up

Export Citation Format

Share Document