Seismic Analysis of Connection Joint of Earthquake Resilient Coupled Shear Wall to Floor Slab

Author(s):  
Chen Cong ◽  
Wen Xianmin
2012 ◽  
Vol 39 (8) ◽  
pp. 867-877 ◽  
Author(s):  
Damien Gilles ◽  
Ghyslaine McClure

Structural engineers routinely use rational dynamic analysis methods for the seismic analysis of buildings. In linear analysis based on modal superposition or response spectrum approaches, the overall response of a structure (for instance, base shear or inter-storey drift) is obtained by combining the responses in several vibration modes. These modal responses depend on the input load, but also on the dynamic characteristics of the building, such as its natural periods, mode shapes, and damping. At the design stage, engineers can only predict the natural periods using eigenvalue analysis of structural models or empirical equations provided in building codes. However, once a building is constructed, it is possible to measure more precisely its dynamic properties using a variety of in situ dynamic tests. In this paper, we use ambient motions recorded in 27 reinforced concrete shear wall (RCSW) buildings in Montréal to examine how various empirical models to predict the natural periods of RCSW buildings compare to the periods measured in actual buildings under ambient loading conditions. We show that a model in which the fundamental period of RCSW buildings varies linearly with building height would be a significant improvement over the period equation proposed in the 2010 National Building Code of Canada. Models to predict the natural periods of the first two torsion modes and second sway modes are also presented, along with their uncertainty.


Structures ◽  
2021 ◽  
Vol 34 ◽  
pp. 20-41
Author(s):  
Molham Salameh ◽  
Mohsenali Shayanfar ◽  
Mohammad Ali Barkhordari

Author(s):  
Prashant Sunagar ◽  
Manish S Dharek ◽  
K Nruthya ◽  
K S Sreekeshava ◽  
B Nagashree ◽  
...  

1976 ◽  
Vol 102 (10) ◽  
pp. 2092-2092
Author(s):  
Kyle L. Peyton ◽  
Ralph M. Richard ◽  
Ronald J. Mazar

2017 ◽  
Vol 21 (9) ◽  
pp. 1327-1348
Author(s):  
Cong Chen ◽  
Renjie Xiao ◽  
Xilin Lu ◽  
Yun Chen

Structure with replaceable devices is a type of earthquake resilient structure developed to restore the structure immediately after strong earthquakes. Current researches focus on one type of the replaceable device located in the structural part that is most likely to be damaged; however, plastic deformation would not be limited in a specific part but expand to other parts. To concentrate possible damage in shear wall structures, combined form of replaceable devices was introduced in this article. Based on previous studies, combined form of replaceable coupling beam and replaceable wall foot was used in a coupled shear wall. Influences of the dimension and location of the replaceable devices to the strength and stiffness of the shear wall were investigated through numerical modeling, which was verified by experimental data. Performance comparison between the shear walls with one type and combined form of replaceable devices and the conventional coupled shear wall was performed. In general, the shear wall with combined form of replaceable devices is shown to be better energy dissipated, and proper dimensions and locations of the replaceable devices should be determined.


Author(s):  
Guoqiang LI ◽  
Mengde PANG ◽  
Feifei Sun ◽  
Liulian LI ◽  
Jianyun SUN

Coupled shear walls are widely used in high rise buildings, since they can not only provide efficient lateral stiffness but also behave outstanding energy dissipation ability especially for earthquake-resistance. Traditionally, the coupling beams are made of reinforced concrete, which are prone to shear failure due to low aspect ratio and greatly reduce the efficiency and ability of energy dissipation.  For overcoming the shortcoming of concrete reinforced coupling beams (RCB), an innovative steel coupling beams called two-level-yielding steel coupling beam (TYSCB) is invented to balance the demand of stiffness and energy dissipation for coupled shear walls. TYSCBs are made of two parallel steel beams with yielding at two different levels.  To verify and investigate the aseismic behaviour improvement of TYSCB-coupled shear walls, two 1/3 scale, 10-storey coupled shear wall specimens with TYSCB and RCB were tested under both gravity and lateral displacement reversals. These two specimens were designed with the same bearing capacity, thus to be easier to compare. The experimental TYSCB specimen demonstrated more robust cyclic performance. Both specimens reached 1% lateral drift, however, the TYSCB-coupled shear wall showed minimal strength degradation. Additionally, a larger amount of energy was dissipated during each test of the TYSCB specimen, compared with the RCB specimen. Based on the experimental results, design recommendations are provided.


Sign in / Sign up

Export Citation Format

Share Document