scholarly journals Stability indicating RP HPLC method for determination of levitiracetam in pharmaceutical formulation

2013 ◽  
Vol 1 (04) ◽  
pp. 45-54 ◽  
Author(s):  
M. Krishna Chaitanya Prasad ◽  
G. Vidhya Sagar ◽  
P. Sudhakar

The article reports on a development of RP-HPLC method for the quantitative determination of Levetiracetam in tablet dosage forms. The chromatographic separations were performed using Phenomenex_ C18 (250 mm x 4.6 mm i.d, 5 μm particle size) column at 40 ºC temperatures. The optimum mobile phase consisted of methanol, water and acetonitrile in the ratio of 30:10:60. Auto sampler 20 μl was used and kept at 15 ºC temperature. Analysis was done with flow rate of 1.0 ml/min at 212 nm (_ max of Levetiracetam) wavelength by using photodiode array (PDA) detector. The drug was analyzed for acid, alkaline, oxidative, hydrolytic, photolytic and thermal degradation studies. The standard calibration curve was plotted for the drug and results showed that the drug was linear (r2 = 0.999) in the concentration range between 0.01 – 1.5 μg/ml. The results of stress testing undertaken according to the International Conference on Harmonization (ICH) guidelines reveal that the selected method is selective and stability-indicating for determination of levitiracetam in pharmaceutical formualtion.

2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Shilpi Pathak ◽  
Pradeep Mishra

Abstract Background A stability-indicating RP-HPLC method was developed and validated for the estimation of empagliflozin drug and its tablet dosage form using a DAD detector. The mobile phase consisted of methanol/acetonitrile/0.1%OPA (75:20:5). The peak was observed at 2.54 min using 222.0 nm absorption maxima. Results Calibration curve plot was found within the range of 10–50 µg/mL. The coefficient of determination (R2) was found to be 0.9990. Forced degradation studies were performed for the empagliflozin in various conditions, and the results were calculated as %RSD values and were found to be within the limits. Conclusion The method was validated as per ICH guidelines with respect to all validation parameters.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (04) ◽  
pp. 42-46
Author(s):  
Madhuri Manchala ◽  
◽  
Vijaya Sri Kanagala ◽  
Ganapath Vinay Jain

A simple, precise, accurate and robust RP-HPLC-PDA method was developed and validated for the determination of rilpivirine hydrochloride in tablet dosage forms. Reverse-phase chromatography was performed on a BDS hypersil (250 mm × 4.6 mm, 6 μm) column of Waters HPLC with Empower software and with a photodiode array detector. Methanol: acetonitrile: water 80:13.5:6.5 (v/v) was used as the mobile phase at a flow rate of 1 mL min-1 with PDA detection at 306 nm. Rilpivirine hydrochloride nanosuspension was prepared by using an ultrasonic homogenization method. Linearity was observed in the concentration range of 0.1–10 μg mL-1 with regression equation y = 508856X+46908 (R2 = 0.9998). The method was validated as per ICH guidelines. The RSD for intra-day (1.31- 0.67) and inter-day (1.69-1.59) precision was found to be less than 2%. The developed method is simple, precise and robust for the determination of rilpivirine hydrochloride and is successfully applied for the nanosuspension.


Author(s):  
Deepthi R ◽  
Gowri Sankar D

Objective: The present study aimed to develop a stability-indicating reverse-phase high performance-liquid chromatography (RP-HPLC) method for the estimation of Sofosbuvir, Velpatasvir, and Voxilaprevir in tablet dosage form and validated in accordance with ICH guidelines. Methods: The optimized conditions for the developed RP-HPLC method are Agilent C18 (250 mm×4.6mm, 5μ) column maintained at 30ºC with a mobile phase consisting of Buffer(0.1%OPA) and Acetonitrile taken in the ratio 55:45%v/v on isocratic mode at flow rate 1.0ml/min. The sample was detected at 220 nm. Results: The retention time of Sofosbuvir, Velpatasvir, and Voxilaprevir was found to be 2.17, 2.731 and 3.55 min respectively. The developed method was validated for accuracy, precision, specificity, ruggedness, robustness and solution stability.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
J. Saroja ◽  
Anantha Lakshmi P.V. ◽  
Y. Rammohan ◽  
D. Divya Reddy

Abstract Background We describe a “stability-indicating liquid chromatography” technique for the estimation of dimethicone (DEC) and dicyclomine hydrochloride (DEH) in the established tablet formulations. Individual quantification of DEH and DEC was reported. But simultaneous quantification of DEH and DEC was lacking. DEH and DEC were analysed on an “XTerra C18 column (250 mm × 4.6 mm, 5 μm)” with the mobile phase solvent run isocratically with 0.1M K2HPO4-acetonitrile (55:45, v/v) on a flow speed of 1.0 mL/min. Results The chromatographic run period for the DEC and DEH assay was 6.0 min with retention times of 2.134 and 2.865 min, respectively. The method was validated for accuracy (99.453 to 100.417% and 99.703 to 100.303% recovery values for DEH and DEC, respectively), precision (RSV value 0.135% for DEC and 0.171% for DEH), linearity (5–15 μg/mL for DEH and 20–60 μg/mL for DEC), selectivity (no hinderance from excipients) and specificity (no hinderance from degradants) recovery. Conclusion The developed stability-indicating liquid chromatography process was well applied to established tablet formulations.


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (03) ◽  
pp. 32-42
Author(s):  
G. P Wani ◽  
◽  
S. B Jadhav

Simple, rapid, precise, accurate RP-HPLC and HPTLC methods have been developed and validated for ivermectin in bulk and its marketed formulation. RP-HPLC method for drug was achieved on Grace C18 (250 mm X 4.6 ID, Particle size; 5 μ) column using mobile phase acetonitrile: 10 mM phosphate buffer (95:05 v/v) pH adjusted to 3 with o-phosphoric acid. Detection of drug was done at 245 nm. The retention time was found to be 5.83 min. HPTLC method for ivermectin was accomplished on a precoated silica gel aluminium plate 60F-254 (CAMAG Linomat 5), using toluene: methanol: glacial acetic acid (8:2:0.1 v/v/v) as a mobile phase. The densitometric scanning was performed at 245 nm which showed Rf 0.46 for ivermectin. The stress testing of the drug individually was carried out under acidic, alkaline, oxidation, photo-stability and thermal degradation conditions. The proposed methods were successfully applied for the determination of drug in bulk and its marketed formulation.


2010 ◽  
Vol 93 (2) ◽  
pp. 523-530 ◽  
Author(s):  
Sérgio Luiz Dalmora ◽  
Maximiliano da Silva Sangoi ◽  
Daniele Rubert Nogueira ◽  
Lucélia Magalhães da Silva

Abstract An RP-HPLC method was validated for the determination of entecavir in tablet dosage form. The HPLC method was carried out on a Gemini C18 column (150 4.6 mm id) maintained at 30C. The mobile phase consisted of acetonitrilewater (95 + 5, v/v)/potassium phosphate buffer (0.01 M, pH 4; 9 + 91, v/v) pumped at a flow rate of 1.0 mL/min. Photodiode array detection was at 253 nm. The chromatographic separation was obtained with a retention time of 4.18 min, and the method was linear in the range of 0.5200 g/mL (r2 0.9998). The specificity and stability-indicating capability of the method was proven through forced degradation studies, which also showed that there was no interference of the excipients and an increase of the cytotoxicity only by the basic condition. The accuracy was 101.19, with bias lower than 1.81. The LOD and LOQ were 0.39 and 0.5 g/mL, respectively. Method validation demonstrated acceptable results for precision and robustness. The proposed method was applied for the analysis of tablet formulations, to improve QC and assure therapeutic efficacy.


2020 ◽  
Vol 10 (6) ◽  
pp. 6610-6618

A Simple, selective, accurate, precise, linear, and stability-indicating RP-HPLC method was developed and validated for the estimation of Cinacalcet hydrochloride in bulk and tablet dosage forms. Chromatographic separation was achieved on X-Terra Symmetry C18 (4.6 x 150mm; 5 m) with mobile phase containing Phosphate buffer: Acetonitrile (40:60 v/v) pH adjusted to 3.0 ±0.05 with diluted ortho-phosphoric acid. The flow rate was maintained at 0.9 mL/min. The eluent was monitored at 282 nm. Moreover, the retention time of Cinacalcet was 2.8 minutes. The method was validated for linearity, accuracy, precision, and robustness as per ICH guidelines. The developed method was found linear between 25-150 μg/ml, and the linear regression coefficient was 0.999. The % RSD values are less than 2 % indicating the accuracy and precision of the method. The percentage of recovery was obtained from 98-102%. The system suitability parameters were found to be within the limit. Forced degradation studies were conducted under various conditions. The proposed method is simple, rapid, precise, and accurate. It can be used for the quantitation of Cinacalcet hydrochloride in bulk and commercial pharmaceutical dosage forms.


Author(s):  
Sonalika Patro ◽  
S. Harshith Kumar ◽  
M. Barath kumar ◽  
E. Masthaniah ◽  
K. Sairam ◽  
...  

A Simple, accurate and precise method was developed and validated for the determination of flucloxacillin sodium in its tablet dosage form. The separation was eluted on xterra c18 column (4.6x150mm, 5micron) using a mixture of octane buffer and methanol as mobile phase in a ratio of (30:70) which was pumped through column at a flow rate of  1ml/min. Optimised wavelength for flucloxacillin was 237nm, the retention time was 2.305minutes and the percentage purity was found to be 98.14%. System suitability parameters such as theoretical plate and tailing factor for flucloxacillin sodium was found to be 2991.64 and 1.90 respectively, the proposed method was validated as per ICH guidelines (ICH, Q2 AND (R1)) the method was found to be linear at the concentration range of 20-100µg/ml and the correlation coefficient (r2) value was found to be 0.9994 percentage RSD for precision was 0.9% and percentage RSD for ruggedness was 0.5%. The precision study was precise, robust and repeatable. The LOD and LOQ values are 2.98 and 9.98 respectively. Hence the suggested RP-HPLC method can be used for routine analysis for flucloxacillin sodium in tablet dosage form.


2020 ◽  
Vol 26 (1) ◽  
pp. 75-81
Author(s):  
Kadali Jagadeesh ◽  
Nowduri Annapurna

Background : The combination of chlorthalidone and benidipine was used to manage hypertension. The mixture of chlorthalidone and benidipine in tablet dosage form has not been previously determined by any method. A stability indicating HPLC method was developed for the simultaneous determination of benidipine and chlorthalidone in bulk and tablets. Methods: Chromatographic separation was accomplished in a reverse phase system using an isocratic elution with a mobile phase composed of methanol-0.1M dipotassium hydrogen phosphate buffer (40:60, v/v), at 1 ml/min flow rate. The photodiode array (PDA) detector set at 260 nm was used to detect and quantify benidipine and chlorthalidone. Benidipine and chlorthalidone tablet samples were subjected to degradation under acid, neutral, alkali, thermal, photo and oxidative. The proposed method was effectively adapted to quantify benidipine and chlorthalidone in the combined tablet formulation. Results: The elution times for benidipine and chlorthalidone were approximately 4.573 min and 6.422 min, respectively. The method was validated within a concentration range of 2 - 6 μg/ml (R2 = 0.9997) for benidipine and 6.25 - 18.75 μg/ml (R2 = 0.9998) for chlorthalidone. Adequate results were obtained for precision (RSD% = 0.106% for benidipine and RSD% = 0.031% for chlorthalidone) and accuracy (99.95 - 100.25 % mean recovery for benidipine and 99.60 - 99.63% mean recovery for chlorthalidone). Robustness has also been found to be acceptable. During the degradation study, interference was not noticed in the analysis of studied drugs. Conclusion: The findings demonstrated that the method could be useful for determination of the selected drug combination in routine analysis.


Author(s):  
Wamorkar V V ◽  
C S Ramaa ◽  
Manjunath S Y ◽  
V Malla Reddy

RP-HPLC method has been developed and validated for the determination of voricaonazole in bulk drug. The developed method is found to be specific, reproducible, and stability indicating. The Hypersil, C18 (250 X 4.6 mm) 5μ column was used and mobile phase consisting of water:acetonitrile to achieve good resolution and retention of the analyte and its impurities. The detector linearity was established from concentrations ranging from 5-100 μg/ml. The method was tested at different levels of specificity and accuracy as per requirements given in ICH guidelines. The molecule was exposed to the stress conditions such as acid, base, oxidation, heat and light as per the recommendations of ICH guidelines. The method was proved to be robust with respect to changes in flow rate, mobile phase composition and allied columns. The proposed method is found to be sensitive, precise, rapid, reproducible, and offers good column life.