scholarly journals Development and Validation of a Stability-Indicating RP-HPLC Method for the Simultaneous Determination of Sofosbuvir, Velpatasvir, and Voxilaprevir in Tablet Formulation

Author(s):  
Deepthi R ◽  
Gowri Sankar D

Objective: The present study aimed to develop a stability-indicating reverse-phase high performance-liquid chromatography (RP-HPLC) method for the estimation of Sofosbuvir, Velpatasvir, and Voxilaprevir in tablet dosage form and validated in accordance with ICH guidelines. Methods: The optimized conditions for the developed RP-HPLC method are Agilent C18 (250 mm×4.6mm, 5μ) column maintained at 30ºC with a mobile phase consisting of Buffer(0.1%OPA) and Acetonitrile taken in the ratio 55:45%v/v on isocratic mode at flow rate 1.0ml/min. The sample was detected at 220 nm. Results: The retention time of Sofosbuvir, Velpatasvir, and Voxilaprevir was found to be 2.17, 2.731 and 3.55 min respectively. The developed method was validated for accuracy, precision, specificity, ruggedness, robustness and solution stability.

Author(s):  
Krishna Kishore Adireddy ◽  
Srinivasa Rao Baratam ◽  
Nagarjuna Hari Pratap S

A simple, rapid, accurate and precise RP-HPLC method was developed and validated for the determination of Istradefylline in table dosage form. Chromatographic analysis of the drug was achieved on Shimadzu HPLC comprising of LC- 20 AD binary gradient pump, a variable wavelength programmable SPD-20A detector and SCL system controller. C18G column (250 mm x 4.6 mm, 5 μ) as stationary phase with mobile phase consisting of 0.1 % orthophosphoric acid and acetonitrile in the ratio of 30: 70 v/v. The method showed a good linear response in the concentration range of 10-90 μg/ml with correlation coefficient of 0.9993. The flow rate was maintained at 1.0 ml/min and detection was carried out at 246 nm. The retention time was 3.125 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, solution stability, selectivity and sensitivity. The results obtained in the study were within the limits of ICH guidelines and hence this method can be used for the determination of istradefylline in tablet formulation.


Author(s):  
Sireesha D ◽  
Sai Lakshmi E ◽  
Sravya E ◽  
Vasudha Bakshi

A new simple, rapid, specific, accurate, precise and novel Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method has been developed for the estimation of Sitagliptin Phosphate in the pharmaceutical dosage form. The chromatographic separation for Sitagliptin was achieved with mobile phase containing methanol, Thermoscientific C18 column, (250x4.6 particle size of 5μ) at room temperature and UV detection at 248 nm. The compounds were eluted in the isocratic mode at a flow rate of 1ml/min. The retention time of Sitagliptin was 1.91min. The above method was validated in terms of linearity, accuracy, precision, LOD and LOQ in accordance with ICH guidelines.


2020 ◽  
Vol 10 (6) ◽  
pp. 6610-6618

A Simple, selective, accurate, precise, linear, and stability-indicating RP-HPLC method was developed and validated for the estimation of Cinacalcet hydrochloride in bulk and tablet dosage forms. Chromatographic separation was achieved on X-Terra Symmetry C18 (4.6 x 150mm; 5 m) with mobile phase containing Phosphate buffer: Acetonitrile (40:60 v/v) pH adjusted to 3.0 ±0.05 with diluted ortho-phosphoric acid. The flow rate was maintained at 0.9 mL/min. The eluent was monitored at 282 nm. Moreover, the retention time of Cinacalcet was 2.8 minutes. The method was validated for linearity, accuracy, precision, and robustness as per ICH guidelines. The developed method was found linear between 25-150 μg/ml, and the linear regression coefficient was 0.999. The % RSD values are less than 2 % indicating the accuracy and precision of the method. The percentage of recovery was obtained from 98-102%. The system suitability parameters were found to be within the limit. Forced degradation studies were conducted under various conditions. The proposed method is simple, rapid, precise, and accurate. It can be used for the quantitation of Cinacalcet hydrochloride in bulk and commercial pharmaceutical dosage forms.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Shilpi Pathak ◽  
Pradeep Mishra

Abstract Background A stability-indicating RP-HPLC method was developed and validated for the estimation of empagliflozin drug and its tablet dosage form using a DAD detector. The mobile phase consisted of methanol/acetonitrile/0.1%OPA (75:20:5). The peak was observed at 2.54 min using 222.0 nm absorption maxima. Results Calibration curve plot was found within the range of 10–50 µg/mL. The coefficient of determination (R2) was found to be 0.9990. Forced degradation studies were performed for the empagliflozin in various conditions, and the results were calculated as %RSD values and were found to be within the limits. Conclusion The method was validated as per ICH guidelines with respect to all validation parameters.


Author(s):  
Wamorkar V V ◽  
C S Ramaa ◽  
Manjunath S Y ◽  
V Malla Reddy

RP-HPLC method has been developed and validated for the determination of voricaonazole in bulk drug. The developed method is found to be specific, reproducible, and stability indicating. The Hypersil, C18 (250 X 4.6 mm) 5μ column was used and mobile phase consisting of water:acetonitrile to achieve good resolution and retention of the analyte and its impurities. The detector linearity was established from concentrations ranging from 5-100 μg/ml. The method was tested at different levels of specificity and accuracy as per requirements given in ICH guidelines. The molecule was exposed to the stress conditions such as acid, base, oxidation, heat and light as per the recommendations of ICH guidelines. The method was proved to be robust with respect to changes in flow rate, mobile phase composition and allied columns. The proposed method is found to be sensitive, precise, rapid, reproducible, and offers good column life.


INDIAN DRUGS ◽  
2020 ◽  
Vol 57 (07) ◽  
pp. 47-51
Author(s):  
B. Anupama ◽  
P. Tejaswi ◽  
KNV. Chenchu Lakshmi ◽  
A. Vishwanadh

A rapid, simple and precise reversed phase high performance liquid chromatography (RP-HPLC) method was developed for the estimation of edoxabantosylate in tablets. The quantification was carried out using a Phenomenex C-18 column (250×4.6 mm i.d., 5µm particle size) in isocratic mode with mobile phase comprising of ammonium acetate buffer andacetonitrile in the ratio of 50:50 (V/V) at a flow rate 1 mL/min. The eluent was monitored at 240 nm. The retention time of the drug was 3.486 min. The calibration curve was linear in the concentration range of 5-25 µg/mL and per cent recovery ranged from 98.25-101.6.The developed method was validated as per ICH guidelines and the results obtained were satisfactory.The method can be applied for routine quality control analysis of edoxabantosylate in tablet dosage forms.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (04) ◽  
pp. 42-46
Author(s):  
Madhuri Manchala ◽  
◽  
Vijaya Sri Kanagala ◽  
Ganapath Vinay Jain

A simple, precise, accurate and robust RP-HPLC-PDA method was developed and validated for the determination of rilpivirine hydrochloride in tablet dosage forms. Reverse-phase chromatography was performed on a BDS hypersil (250 mm × 4.6 mm, 6 μm) column of Waters HPLC with Empower software and with a photodiode array detector. Methanol: acetonitrile: water 80:13.5:6.5 (v/v) was used as the mobile phase at a flow rate of 1 mL min-1 with PDA detection at 306 nm. Rilpivirine hydrochloride nanosuspension was prepared by using an ultrasonic homogenization method. Linearity was observed in the concentration range of 0.1–10 μg mL-1 with regression equation y = 508856X+46908 (R2 = 0.9998). The method was validated as per ICH guidelines. The RSD for intra-day (1.31- 0.67) and inter-day (1.69-1.59) precision was found to be less than 2%. The developed method is simple, precise and robust for the determination of rilpivirine hydrochloride and is successfully applied for the nanosuspension.


2020 ◽  
Vol 10 (6) ◽  
pp. 31-36
Author(s):  
P Nagamani ◽  
SY Manjunath ◽  
T Hemant Kumar

A simple, precise, accurate, and rapid reverse phase-high performance liquid chromatography (RP-HPLC) method with UV-Visible detector has been developed and subsequently validated for the simultaneous determination of amlodipine besylate(AML) and celecoxib(CEL) in their combined tablet dosage form. The separation was based on the use of a Flowrosil C18   analytical column (250 × 4.6 mm, i.d., 5 µm). The mobile phase consisted of a mixture of 80 volumes of acetonitrile and 20 volumes of water. The chromatography was performed by isocratic elution at a flow rate of 1 mL/min. Analytes were detected at 250 nm, with linear calibration curves at concentration ranges of 2-12 µg/ml and 50-300 µg/ml for AML and CEL respectively. The retention time of AML and CEL were 1.98 and 3.15 min respectively. The recoveries obtained were 99.46‒101.36% for AML, 99.57‒101.42% and 99.96–100.87 % for CEL. The method was validated according to International conference of harmonisation guidelines in terms of accuracy, precision, specificity, robustness, limits of detection and quantitation, and other aspects of analytical validation. The developed method was applied successfully for HPLC analysis of commercial pharmaceutical products including AML and CEL. Keywords: Amlodipine besylate; Celecoxib; RP-HPLC.


INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (05) ◽  
pp. 61-64
Author(s):  
A. L Rao ◽  
◽  
R. V Bhaskara

A reverse phase high performance liquid chromatographic method was developed and validated asper ICH guidelines for estimation of trandolapril and verapamil in combined tablet dosage form. Theseparation was obtained using a mobile phase consisting of acetonitrile and phosphate buffer adjustingpH to 3.0 in the ratio of 70:30 v/v and using Waters C18 (250 x 4.6 mm, 5 mcm) column maintained atambient temperature. The flow rate was 1.2 mL min-1 and UV detection was monitored at 215 nm. Theretention time (min) and linearity range (mcg mL-1) for trandolapril and verapamil were (5.12, 2.70) and(20-60, 20-60), respectively. The method validation results are within the acceptance criteria for precision,accuracy and linearity. The proposed method was found to be suitable for routine quality control ofmarketed formulation containing these APIs.


2017 ◽  
Vol 9 (6) ◽  
pp. 54 ◽  
Author(s):  
Yuliya Kondratova ◽  
Liliya Logoyda ◽  
Yuliia Voloshko ◽  
Ahmed Abdel Megied ◽  
Dmytro Korobko ◽  
...  

Objective: A rapid, simple and sensitive RP-HPLC method was developed and validated for the determination of bisoprolol fumarate in bulk and pharmaceutical dosage form.Methods: Chromatographic separation was achieved within 2.5 min on ACQUITY Arc System, Waters Symmetry C18 column (3.9 mm i.d. X 150 mm, 5 μm particle sizes) using a mobile phase consisted of acetonitrile: phosphate buffer (25:75 v/v) in an isocratic mode at a flow rate of 1.4 ml/min. The pH of the mobile phase was adjusted to 7.0 with orthophosphoric acid and UV detection was set at 226 nm.Results: The retention time for bisoprolol fumarate was found to be 2.09 min. The proposed method was validated according to ICH guidelines with respect to linearity, specificity precision, accuracy and robustness. The limit of detection and limit of quantification are calculated and found to be 0.4825 and 1.4621 μg/ml; respectively.Conclusion: The proposed method can help research studies, quality control and routine analysis with lesser resources available. The results of the assay of pharmaceutical formulation of the developed method are highly reliable and reproducible and is in good agreement with the label claim of the medicines.Keywords: Bisoprolol, High-Performance Liquid Chromatography, Validation, ICH guidelines