scholarly journals Evaluating Electrocoagulation Process for Water Treatment Efficiency Using Response Surface Methodology

2020 ◽  
Vol 26 (9) ◽  
pp. 11-23
Author(s):  
Rand Shakir Mahmood ◽  
Nawar O.A. Al-Musawi

The electrocoagulation process became one of the most important technologies used for water treatment processes in the last few years. It’s the preferred method to remove suspended solids and heavy metals from water for treating drinking water and wastewater from textile, diary, and electroplating factories. This research aims to study the effect of using the electrocoagulation process with aluminum electrodes on the removal efficiency of suspended solids and turbidity presented in raw water and optimizing by the response surface methodology (RSM). The most important variables studied in this research included electrode spacing, the applied voltage, and the operating time of the electrocoagulation process. The samples were taken from the Al Qadisiyiah water treatment plant. The treatment set up was in a batch mode; two parallel plates of aluminum were used as electrodes. Experimental results showed that the maximum removal efficiency of 96% for turbidity and 97% for TSS were obtained at operating time 60 minutes, voltage 30 V, and electrode spacing 1.7cm. Two models for predicting removal efficiency obtained, the first model was for turbidity with a correction factor of 94.7%, and the second one was for the TSS with a correction factor of 94.85%.

2017 ◽  
Vol 9 (1) ◽  
Author(s):  
Taty Hernaningsih

Waste water treatment by industry usually uses chemicals that may lead to additional environmental pollution load. On the other hand, water demand increases and environmental regulations regarding waste water disposal requirements that apply more stringent. It is necessary for waste treatment technique that accommodate this requirement. Electrocoagulation process is a technique of wastewater treatment that has been chosen because the technique is environmentally friendly. This paper will review some of the research or application electrocoagulation process which is conducted on industrial waste water. Types of industrial waste water that is to be reviewed include: industries batik, sarongs, textiles, palm oil, slaughterhouses, food, leather tanning, laundry, pulp and paper. Overview reviewed in this research include the waste water treatment process in several processing variations such as: change in time, electricity and kind of electrodes. The results of the research with electrocoagulation process in the industry are the removal efficiency of TSS, COD, BOD5, Chrome, phosphate, surfactants, color turbidity influenced by several factors including time, strong current, voltage, distance and type of electrode and pH. The results of the study with electrocoagulation process in the industry is the removal efficiency of TSS, COD, BOD5, chromium, phosphate, surfactant, turbidity color that are influenced by several factors including time, strong current, voltage, distance and type of electrode and pH. It is hoped the information presented in this article can be a reference for similar research for the improvement of research on the process ektrokoagulasi.Key words: elektrocoagulation, removal eficiency, environmental friendly


2017 ◽  
Vol 76 (4) ◽  
pp. 776-784 ◽  
Author(s):  
Mijia Zhu ◽  
Jun Yao ◽  
Zhonghai Qin ◽  
Luning Lian ◽  
Chi Zhang

Wastewater produced from polymer flooding in oil production features high viscosity and chemical oxygen demand because of the residue of high-concentration polymer hydrolysed polyacrylamide (HPAM). In this study, steel slag, a waste from steel manufacturing, was studied as a low-cost adsorbent for HPAM in wastewater. Optimisation of HPAM adsorption by steel slag was performed with a central composite design under response surface methodology (RSM). Results showed that the maximum removal efficiency of 89.31% was obtained at an adsorbent dosage of 105.2 g/L, contact time of 95.4 min and pH of 5.6. These data were strongly correlated with the experimental values of the RSM model. Single and interactive effect analysis showed that HPAM removal efficiency increased with increasing adsorbent dosage and contact time. Efficiency increased when pH was increased from 2.6 to 5.6 and subsequently decreased from 5.6 to 9.3. It was observed that removal efficiency significantly increased (from 0% to 86.1%) at the initial stage (from 0 min to 60 min) and increased gradually after 60 min with an adsorbent dosage of 105.2 g/L, pH of 5.6. The adsorption kinetics was well correlated with the pseudo-second-order equation. Removal of HPAM from the studied water samples indicated that steel slag can be utilised for the pre-treatment of polymer-flooding wastewater.


2016 ◽  
Vol 74 (3) ◽  
pp. 564-579 ◽  
Author(s):  
Ceyhun Akarsu ◽  
Yasin Ozay ◽  
Nadir Dizge ◽  
H. Elif Gulsen ◽  
Hasan Ates ◽  
...  

Marine pollution has been considered an increasing problem because of the increase in sea transportation day by day. Therefore, a large volume of bilge water which contains petroleum, oil and hydrocarbons in high concentrations is generated from all types of ships. In this study, treatment of bilge water by electrocoagulation/electroflotation and nanofiltration integrated process is investigated as a function of voltage, time, and initial pH with aluminum electrode as both anode and cathode. Moreover, a commercial NF270 flat-sheet membrane was also used for further purification. Box–Behnken design combined with response surface methodology was used to study the response pattern and determine the optimum conditions for maximum chemical oxygen demand (COD) removal and minimum metal ion contents of bilge water. Three independent variables, namely voltage (5–15 V), initial pH (4.5–8.0) and time (30–90 min) were transformed to coded values. The COD removal percent, UV absorbance at 254 nm, pH value (after treatment), and concentration of metal ions (Ti, As, Cu, Cr, Zn, Sr, Mo) were obtained as responses. Analysis of variance results showed that all the models were significant except for Zn (P > 0.05), because the calculated F values for these models were less than the critical F value for the considered probability (P = 0.05). The obtained R2 and Radj2 values signified the correlation between the experimental data and predicted responses: except for the model of Zn concentration after treatment, the high R2 values showed the goodness of fit of the model. While the increase in the applied voltage showed negative effects, the increases in time and pH showed a positive effect on COD removal efficiency; also the most effective linear term was found as time. A positive sign of the interactive coefficients of the voltage–time and pH–time systems indicated synergistic effect on COD removal efficiency, whereas interaction between voltage and pH showed an antagonistic effect.


2014 ◽  
Vol 69 (9) ◽  
pp. 1805-1812 ◽  
Author(s):  
Jian Zhou ◽  
Guangxu Qin ◽  
Jianbing Zhang ◽  
Yancheng Li ◽  
Qiang He ◽  
...  

The coping strategy of a CANON (completely autotrophic nitrogen removal over nitrite) reactor working at room temperature was investigated using response surface methodology. The total nitrogen (TN) removal efficiency was taken as a dependent variable. The temperature (X), dissolved oxygen (DO) concentration (Y), and influent nitrogen loading rate (Z) were taken as independent variables. Results showed that the relation of these three independent variables can be described by the TN removal efficiency expressed as −5.03 + 1.51X + 45.16Y + 30.13Z + 0.26XY + 1.84XZ − 0.04X2 − 9.06Y2 − 99.00Z2. The analysis of variance proved that the equation is applicable. The response surface demonstrated that the temperature significantly interacts with the DO concentration and influent N loading rate. A coping strategy for the CANON reactor working at room temperature is thus proposed: altering the DO concentration and the N loading rate to counterbalance the impact of low temperature. The verification test proved the strategy is viable. The TN removal efficiency was 91.3% when the reactor was operated under a temperature of 35.0 °C, a DO of 3.0 mg/L, and a N loading rate of 0.70 kgN/(m³ d). When the temperature dropped from 35.0 to 19.2 °C, the TN removal efficiency was kept at 88.7% by regulating the influent N loading rate from 0.7 kgN/(m³ d) to 0.35 kgN/(m³ d) and the DO concentration from 3.0 to 2.6 mg/L.


Author(s):  
Negar Jafari ◽  
Afshin Ebrahimi ◽  
Karim Ebrahimpour ◽  
Ali Abdolahnejad

Introduction: Microcystin-leucine arginine (MC-LR) is a toxin with harmful effects on the liver, kidney, heart, and gastrointestinal tract. So, effective removal of MC-LR from water resources is of great importance. The aim of this study was to remove microcystin-LR (MC-LR) from aqueous solution by Titanium Dioxide (TiO2). Materials and Methods: In the present study, TiO2, as a semiconductor, was used for photodegradation of MC-LR under ultraviolet light (UV). The Response Surface Methodology was applied to investigate the effects of operating variables such as pH (A), contact time (B), and catalyst dose (B) on the removal of MC-LR. The MC-LR concentration was measured by high-performance liquid chromatography (HPLC). Results: The results showed that single variables such as A, B, and C had significant effects on MC-LR removal (pvalue < 0.05). In other words, increase of the contact time and catalyst dose had a positive effect on enhancing the removal efficiency of MC-LR, but the effect of pH was negative. The analysis of variance showed that BC, A2, and C2 variables had a significant effect on the MC-LR removal (pvalue < 0.05). Finally, the maximum removal efficiency of MC-LR was 95.1%, which occurred at pH = 5, contact time = 30 minutes, and catalyst dose = 1 g/l. Conclusion: According to the findings, TiO2, as a photocatalyst, had an appropriate effect on degradation of the MC-LR.


2019 ◽  
Vol 6 (1) ◽  
pp. 41-48 ◽  
Author(s):  
Abdul Aziz Hamidi ◽  
Syed Zainal Sharifah Farah Fariza ◽  
Alazaiza Motasem Y.D

Landfill leachate is highly polluted and generated as a result of water infiltration through solid waste produced domestically and industrially. This study investigated the applicability of the response surface methodology (RSM) to optimize the removal performances of chemical oxygen demand (COD), color, and suspended solids (SS) from landfill leachate by coagulation process using Tin tetrachloride pentahydrate. The leachate samples were collected from Alor Pongsu Landfill (APLS) in Perak, Malaysia. Before starting the experiments, general characterization was carried out for raw leachate samples to investigate their physical and chemical properties. The effects of the dosage and pH of SnCl4 on the removal performances were evaluated as well. An ideal experimental design was performed based on the central composite design (CCD) by RSM. In addition, this RSM was used to evaluate the effects of process variables and their interaction toward the attainment of their optimum conditions. The statistical design of the experiments and data analysis was resolved using the Design-Expert software. Further, the range of coagulant dosage and pH was selected based on a batch study which was conducted at 13000 mg/L to 17000 mg/L of SnCl4 and pH ranged from 6 to 10. The results showed that the optimum pH and dosage of SnCl4 were 7.17 and 15 g/L, respectively, where the maximum removal efficiency was 67.7% for COD and 100% for color and SS. The results were in agreement with the experimental data with a maximum removal efficiency of 67.84 %, 98.6 %, and 99.3%, for COD, color, and SS, respectively. Overall, this study verified that the RSM method was viable for optimizing the operational condition of the coagulation-flocculation process.


2018 ◽  
Vol 77 (6) ◽  
pp. 1765-1776 ◽  
Author(s):  
Gagik Badalians Gholikandi ◽  
Khashayar Kazemirad

Abstract In this study, the performance of the electrochemical peroxidation (ECP) process for removing the volatile suspended solids (VSS) content of waste-activated sludge was evaluated. The Fe2+ ions required by the process were obtained directly from iron electrodes in the system. The performance of the ECP process was investigated in various operational conditions employing a laboratory-scale pilot setup and optimized by response surface methodology (RSM). According to the results, the ECP process showed its best performance when the pH value, current density, H2O2 concentration and the retention time were 3, 3.2 mA/cm2, 1,535 mg/L and 240 min, respectively. In these conditions, the introduced Fe2+ concentration was approximately 500 (mg/L) and the VSS removal efficiency about 74%. Moreover, the results of the microbial characteristics of the raw and the stabilized sludge demonstrated that the ECP process is able to remove close to 99.9% of the coliforms in the raw sludge during the stabilization process. The energy consumption evaluation showed that the required energy of the ECP reactor (about 1.8–2.5 kWh (kg VSS removed)−1) is considerably lower than for aerobic digestion, the conventional waste-activated sludge stabilization method (about 2–3 kWh (kg VSS removed)−1). The RSM optimization process showed that the best operational conditions of the ECP process comply with the experimental results, and the actual and the predicted results are in good conformity with each other. This feature makes it possible to predict the introduced Fe2+ concentrations into the system and the VSS removal efficiency of the process precisely.


Sign in / Sign up

Export Citation Format

Share Document