Effect of the Ion Size Ratio of Components and Electrical Transfer on Transfer Phenomena during Contact Melting

2021 ◽  
Vol 85 (9) ◽  
pp. 1016-1018
Author(s):  
A. A. Akhkubekov ◽  
S. N. Akhkubekova ◽  
A. R. Manukyants ◽  
V. A. Sozaev
Author(s):  
Yury Rubanov ◽  
Yury Rubanov ◽  
Yulia Tokach ◽  
Yulia Tokach ◽  
Marina Vasilenko ◽  
...  

There was suggested a method of obtaining a complex adsorbent with magnetic properties for the oil spill clean-up from the water surface by means of controlled magnetic field. As magnetic filler a finely-dispersed iron-ore concentrate in the form of magnetite, obtained by wet magnetic separation of crushed iron ore, was suggested. As an adsorbing component the disintegrating electric-furnace steelmaking slag, obtained by dry air-cooling method, was selected. The mass ratio of components slag:magnetite is 1(1,5÷2,0). For cleaning up emergency oil spills with the suggested magnetic adsorbent a facility, which is installed on a twin-hulled oil recovery vessel, was designed. The vessel contains a rectangular case between the vessel hulls with inlet and outlet for the treated water, the bottom of which is a permanently moving belt. Above the belt, at the end point of it there is an oil-gathering drum with magnetic system. The adsorbent is poured to oil-products layer from a hopper, provided with drum feeder. Due to the increased bulk weight the adsorbent sinks rapidly into the oil layer on the water surface. If the large non-floating flocculi are formed, they sink and sedimentate on the moving belt and are moved to the oil-gathering drum. The saturated adsorbent is removed from the drum surface with a scraper, connected with a gutter, with contains a rotating auger.


2010 ◽  
Vol 156-157 ◽  
pp. 1702-1707
Author(s):  
Xiang Wen Cheng ◽  
Jinchao Liu ◽  
Qi Zhi Ding ◽  
Li Ming Song ◽  
Zhan Lin Wang

How to predict the relationship among particle size and among product size, to establish the relationship between the granularity and working parameters in the process of grinding and to determine the optimum operating parameters. With proposing BS squeeze crush model by L. Bass and the idea of roll surface division as the material uneven extrusion force are adopted. Based on field experiments the experimental data is analyzed, the select function and the breakage functions are fitted with MATLAB software, and obtaining their model. The comminution model is determined by the roller division. We obtain the model parameter through the experimental data. Through model analysis shows: the relationship between particle breakage and energy absorption, namely the smaller size of the same power, the lower broken; the breakage diminishes with the decrease of particle size ratio and it will be tending to a small constant when the smaller particle size ratio. The breakage functions rapidly decrease within ratio of between 0.2-0.7. This shows: the energy consumption will rapidly increase when the particle size of less than 0.2 in broken; the selection diminish with the decrease of particle size. Pressure (8-9MPa) should be the most appropriate value.


1994 ◽  
Vol 29 (9) ◽  
pp. 213-223 ◽  
Author(s):  
Sandra K. Kaiser ◽  
Richard R. Dague

The “temperature-phased anaerobic biofilter” or TPAB process (U.S. Patent pending), is a new high-rate anaerobic treatment system that includes a thermophilic (56°C) biofilter connected in series with a mesophilic (35°C) biofilter providing for two-temperature, two-phase treatment. Three TPAB systems of different thermophilic:mesophilic reactor size ratios were operated at system HRTs of 24 hrs, 36 hrs, and 48 hrs to characterize performance and to determine if an optimum size ratio exists between the thermophilic and mesophilic phases. The three TPAB systems achieved SCOD reductions in excess of 97% and TCOD reductions in excess of 90% for a synthetic milk substrate over a range of system COD loadings from 2 g COD/L/day to 16 g COD/L/day. There was little difference in performance between the three TPAB systems based on COD reduction and methane production. The 1:7 ratio of thermophilic:mesophilic phase TPAB system performed as well as the 1:3 and 1:1 size ratio TPAB systems. In applications of the process, a relatively small thermophilic first-phase can be used without sacrificing overall two-phase system performance. The TPAB process is a promising new anaerobic treatment technology with the ability to achieve higher efficiencies of organic removals than is generally possible for single-stage anaerobic filter systems operated at equivalent HRTs and organic loadings.


RSC Advances ◽  
2021 ◽  
Vol 11 (26) ◽  
pp. 15701-15709
Author(s):  
Siyu Hu ◽  
Anchi Yu ◽  
Rong Lu

The ion size effect on graphitic carbon nitride is responsible for variations in its structure, optical and electronic properties, and hence the enhancement in photocatalytic hydrogen evolution.


Author(s):  
Hiroyuki Katsuto ◽  
Ryuichi Okamoto ◽  
Tomonari Sumi ◽  
Kenichiro Koga

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jian Zhang ◽  
Anil Can ◽  
Pui Man Rosalind Lai ◽  
Srinivasan Mukundan ◽  
Victor M. Castro ◽  
...  

AbstractMorphological factors of intracranial aneurysms and the surrounding vasculature could affect aneurysm rupture risk in a location specific manner. Our goal was to identify image-based morphological parameters that correlated with ruptured basilar tip aneurysms. Three-dimensional morphological parameters obtained from CT-angiography (CTA) or digital subtraction angiography (DSA) from 200 patients with basilar tip aneurysms diagnosed at the Brigham and Women’s Hospital and Massachusetts General Hospital between 1990 and 2016 were evaluated. We examined aneurysm wall irregularity, the presence of daughter domes, hypoplastic, aplastic or fetal PCoAs, vertebral dominance, maximum height, perpendicular height, width, neck diameter, aspect and size ratio, height/width ratio, and diameters and angles of surrounding parent and daughter vessels. Univariable and multivariable statistical analyses were performed to determine statistical significance. In multivariable analysis, presence of a daughter dome, aspect ratio, and larger flow angle were significantly associated with rupture status. We also introduced two new variables, diameter size ratio and parent-daughter angle ratio, which were both significantly inversely associated with ruptured basilar tip aneurysms. Notably, multivariable analyses also showed that larger diameter size ratio was associated with higher Hunt-Hess score while smaller flow angle was associated with higher Fisher grade. These easily measurable parameters, including a new parameter that is unlikely to be affected by the formation of the aneurysm, could aid in screening strategies in high-risk patients with basilar tip aneurysms. One should note, however, that the changes in parameters related to aneurysm morphology may be secondary to aneurysm rupture rather than causal.


2019 ◽  
Vol 351 ◽  
pp. 92-101 ◽  
Author(s):  
Zhang-Rong Liu ◽  
Wei-Min Ye ◽  
Zhao Zhang ◽  
Qiong Wang ◽  
Yong-Gui Chen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document